Yunbyeong Chae
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yunbyeong Chae has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Minseok Park
4 shared publicationsRamin Rabiee
Department of Civil and Environmental Engineering, Ohio Northern University, Ada, OH, USA
4 shared publicationsChul‐Young Kim
Department of Civil and Environmental Engineering Myongji University Yongin South Korea
3 shared publications- James Michael Ricles
Department of Civil and Environmental Engineering Lehigh University Bethlehem Pennsylvania USA
3 shared publications - Baiping Dong
Lehigh University
2 shared publications Chul-Young Kim
2 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-17
A new similitude law for testing scaled RC structures
In a scaled model test for reinforced concrete (RC) structures, the stress-strain relationship of the concrete of the scaled model is often quite different from that of ordinary concrete which is used for the prototype, while that of the reinforcement is typically the same for both the prototype and scaled model. The difference in the material properties of the reinforcement and concrete affects the behavior of the scaled model, which needs to be properly considered in order to accurately predict the prototype’s response from the scaled model’s response. In this study, a new similitude law that can effectively consider the difference in material properties between the prototype and scaled model is proposed and verified through numerical simulations with RC columns. The simulation results clearly show that the new similitude law can predict the prototype’s response better than other similitude laws proposed in previous studies.
- 1 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-17
Open AccessA new similitude law for testing scaled RC structures
In a scaled model test for reinforced concrete (RC) structures, the stress-strain relationship of the concrete of the scaled model is often quite different from that of ordinary concrete which is used for the prototype, while that of the reinforcement is typically the same for both the prototype and scaled model. The difference in the material properties of the reinforcement and concrete affects the behavior of the scaled model, which needs to be properly considered in order to accurately predict the prototype’s response from the scaled model’s response. In this study, a new similitude law that can effectively consider the difference in material properties between the prototype and scaled model is proposed and verified through numerical simulations with RC columns. The simulation results clearly show that the new similitude law can predict the prototype’s response better than other similitude laws proposed in previous studies.
- 30 May 2025
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 29 (3) , 181-188
Enhanced System Identification and Finite Element Model Updating for Concrete Random Fields
- 30 May 2025
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 29 (3) , 181-188
Enhanced System Identification and Finite Element Model Updating for Concrete Random Fields
- 30 January 2025
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 29 (1) , 85-89
Seismic Performance Evaluation of Lead Rubber Bearings Using Real-Time Hybrid Simulation
- 30 January 2025
- Published by Earthquake Engineering Society of Korea in Journal of the Earthquake Engineering Society of Korea
- Vol. 29 (1) , 85-89
Seismic Performance Evaluation of Lead Rubber Bearings Using Real-Time Hybrid Simulation
- 11 January 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (4) , 1537-1551
Dynamic cyclic loading tests for investigating the influence of loading rate and axial force on the lateral response of RC columns
The material properties of steel and concrete vary depending on the loading rate to which they are subjected. To realistically evaluate the seismic performance of reinforced concrete (RC) columns, it is necessary to simulate the loading rate that structures will experience during seismic events as accurately as possible. Real‐time dynamic testing is preferred over quasi‐static testing for this purpose. On the other hand, the seismic performance of RC columns also depends on the axial force applied to the column. However, due to the large axial stiffness of RC columns, accurately controlling the axial force during the test, particularly in real‐time testing, is challenging. Consequently, only a few component‐level dynamic tests have been conducted for RC columns. This study aims to explore the influence of axial force and loading rate on the seismic performance of RC columns. To this end, both slow and fast cyclic loading tests were conducted on square cross‐section RC columns subjected to four different axial forces. By utilizing a robust actuator control method along with a specially designed load transfer element, the axial force was successfully controlled, while the lateral displacements were imposed on the columns in real‐time. The results include lateral strengths, postyield responses, damage patterns, rebar strains, and their rates, all of which constitute unique experimental data that can contribute to a deeper understanding of the actual seismic response of RC columns.
- 11 January 2024
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (4) , 1537-1551
Dynamic cyclic loading tests for investigating the influence of loading rate and axial force on the lateral response of RC columns
The material properties of steel and concrete vary depending on the loading rate to which they are subjected. To realistically evaluate the seismic performance of reinforced concrete (RC) columns, it is necessary to simulate the loading rate that structures will experience during seismic events as accurately as possible. Real‐time dynamic testing is preferred over quasi‐static testing for this purpose. On the other hand, the seismic performance of RC columns also depends on the axial force applied to the column. However, due to the large axial stiffness of RC columns, accurately controlling the axial force during the test, particularly in real‐time testing, is challenging. Consequently, only a few component‐level dynamic tests have been conducted for RC columns. This study aims to explore the influence of axial force and loading rate on the seismic performance of RC columns. To this end, both slow and fast cyclic loading tests were conducted on square cross‐section RC columns subjected to four different axial forces. By utilizing a robust actuator control method along with a specially designed load transfer element, the axial force was successfully controlled, while the lateral displacements were imposed on the columns in real‐time. The results include lateral strengths, postyield responses, damage patterns, rebar strains, and their rates, all of which constitute unique experimental data that can contribute to a deeper understanding of the actual seismic response of RC columns.
- 27 April 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (10) , 2928-2944
Real‐time hybrid simulation for investigating the influence of vertical ground motions on the lateral response of RC piers
The vertical component of ground motions can affect the seismic performance of reinforced concrete (RC) piers as significant as its horizontal counterpart. However, real‐time testing for RC piers subjected to both horizontal and vertical ground motions has been scarcely conducted due to the difficulty in multi‐axial control of actuators. In this study, the seismic response of a bridge RC pier was investigated by conducting real‐time hybrid simulation (RTHS), where the RC pier was physically tested in the laboratory and the bridge superstructure was numerically modeled. The test setup that can synchronously apply both horizontal and vertical ground motions was constructed by using three dynamic actuators and a flexible loading beam (FLB). The lateral response of the RC pier was investigated by varying the intensities for vertical ground motions, while the same intensity for horizontal ground motion is used. It was found that the axial force from the dead load of superstructure can significantly affect the initial stiffness, strength, and post‐yield response of the RC pier. For the selected earthquake ground motions, however, the intensity of vertical ground motion did not make a substantial difference in the lateral response, although there was a notable difference in the fracture pattern.
- 27 April 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 52 (10) , 2928-2944
Real‐time hybrid simulation for investigating the influence of vertical ground motions on the lateral response of RC piers
The vertical component of ground motions can affect the seismic performance of reinforced concrete (RC) piers as significant as its horizontal counterpart. However, real‐time testing for RC piers subjected to both horizontal and vertical ground motions has been scarcely conducted due to the difficulty in multi‐axial control of actuators. In this study, the seismic response of a bridge RC pier was investigated by conducting real‐time hybrid simulation (RTHS), where the RC pier was physically tested in the laboratory and the bridge superstructure was numerically modeled. The test setup that can synchronously apply both horizontal and vertical ground motions was constructed by using three dynamic actuators and a flexible loading beam (FLB). The lateral response of the RC pier was investigated by varying the intensities for vertical ground motions, while the same intensity for horizontal ground motion is used. It was found that the axial force from the dead load of superstructure can significantly affect the initial stiffness, strength, and post‐yield response of the RC pier. For the selected earthquake ground motions, however, the intensity of vertical ground motion did not make a substantial difference in the lateral response, although there was a notable difference in the fracture pattern.
- 8 February 2022
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 33 (17) , 2228-2240
Real-time hybrid simulation for a base-isolated building with the transmissibility-based semi-active controller
The transmissibility-based semi-active (TSA) controller was developed in the existing study by the authors, which can effectively enhance the performance of base-isolated buildings under both strong long- and short-period earthquake ground motions. Since the performance of the TSA controller was only evaluated with numerical simulation in the existing study, this paper further validates its performance experimentally by conducting real-time hybrid simulation (RTHS). A three-story base isolated building was designed based on a simplified design procedure, where the base isolation system of the building consisted of three different devices, that is, a magneto-rheological (MR) damper, rubber bearing, and linear bearings. The base isolation system was experimentally tested with the MR damper controlled by the TSA controller, and the building superstructure was analytically modeled. It was shown that the TSA controller makes the system damping high under long-period ground motions and low under short-period ground motions, which performed uniquely as intended. As a result, the isolator displacement was effectively reduced under long-period ground motions, while the story drift and acceleration responses were also reduced under short-period ground motions, all of which are difficult to achieve at the same time using passive damping only.
- 8 February 2022
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 33 (17) , 2228-2240
Real-time hybrid simulation for a base-isolated building with the transmissibility-based semi-active controller
The transmissibility-based semi-active (TSA) controller was developed in the existing study by the authors, which can effectively enhance the performance of base-isolated buildings under both strong long- and short-period earthquake ground motions. Since the performance of the TSA controller was only evaluated with numerical simulation in the existing study, this paper further validates its performance experimentally by conducting real-time hybrid simulation (RTHS). A three-story base isolated building was designed based on a simplified design procedure, where the base isolation system of the building consisted of three different devices, that is, a magneto-rheological (MR) damper, rubber bearing, and linear bearings. The base isolation system was experimentally tested with the MR damper controlled by the TSA controller, and the building superstructure was analytically modeled. It was shown that the TSA controller makes the system damping high under long-period ground motions and low under short-period ground motions, which performed uniquely as intended. As a result, the isolator displacement was effectively reduced under long-period ground motions, while the story drift and acceleration responses were also reduced under short-period ground motions, all of which are difficult to achieve at the same time using passive damping only.
- Open Access
- 1 July 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (7) , 07020002
Closure to “Fast and Slow Cyclic Tests for Reinforced Concrete Columns with an Improved Axial Force Control” by Yunbyeong Chae, Jinhaeng Lee, Minseok Park, and Chul-Young Kim
- 1 July 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 146 (7) , 07020002
Open AccessClosure to “Fast and Slow Cyclic Tests for Reinforced Concrete Columns with an Improved Axial Force Control” by Yunbyeong Chae, Jinhaeng Lee, Minseok Park, and Chul-Young Kim
- Open Access
- 3 November 2018
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 30 (1) , 16-31
Adaptive base isolation system to achieve structural resiliency under both short- and long-period earthquake ground motions
Base isolation system is widely used to protect important and essential buildings from seismic hazards. The use of high damping is effective in reducing the resonance effect under long-period earthquake ground motions. However, high damping increases the acceleration demand under short-period ground motions, leading to a higher risk of damage of nonstructural components. Actually, low damping is beneficial to reduce the acceleration demand under short-period ground motions, suggesting the use of adaptive damping control, that is, high damping under long-period motions and low damping under short-period motions. In order to implement this concept, a semi-actively controlled base isolation system is provided in this article along with a new control law based on the transmissibility theory. Unlike existing studies, the proposed method enables a systematic design procedure for base isolated structures with semi-active dampers, which is called the simplified design procedure in this article. The performance of the proposed system is evaluated with numerical simulations for a base isolated three-story building with magneto-rheological dampers. It was shown that the proposed system achieves a high level of performance under long-period ground motions, while maintaining the exceptional performance of a conventional base isolation system with low damping under short-period ground motions.
- 3 November 2018
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 30 (1) , 16-31
Open AccessAdaptive base isolation system to achieve structural resiliency under both short- and long-period earthquake ground motions
Base isolation system is widely used to protect important and essential buildings from seismic hazards. The use of high damping is effective in reducing the resonance effect under long-period earthquake ground motions. However, high damping increases the acceleration demand under short-period ground motions, leading to a higher risk of damage of nonstructural components. Actually, low damping is beneficial to reduce the acceleration demand under short-period ground motions, suggesting the use of adaptive damping control, that is, high damping under long-period motions and low damping under short-period motions. In order to implement this concept, a semi-actively controlled base isolation system is provided in this article along with a new control law based on the transmissibility theory. Unlike existing studies, the proposed method enables a systematic design procedure for base isolated structures with semi-active dampers, which is called the simplified design procedure in this article. The performance of the proposed system is evaluated with numerical simulations for a base isolated three-story building with magneto-rheological dampers. It was shown that the proposed system achieves a high level of performance under long-period ground motions, while maintaining the exceptional performance of a conventional base isolation system with low damping under short-period ground motions.