Gaurav Jindal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gaurav Jindal has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Dheeraj Gandhi
Division of Interventional Neuroradiology, Department of Radiology, University of Maryland Medical Center, Baltimore MD, USA; Department of Neurology, University of Maryland Medical Center, Baltimore MD, USA; Department of Neurosurgery, University of Maryland Medical Center, Baltimore MD, USA
10 shared publicationsTimothy Miller
Department of Radiology, Division of Interventional Neuroradiology, University of Maryland Medical Center, Baltimore, Maryland
7 shared publications- Dheeraj Gandhi
Division of Neurointerventional Surgery, Department of Neurosurgery, University of Maryland Medical Center, Baltimore (H.C., D.G.).
6 shared publications - Timothy Ryan Miller
Radiology, University of Maryland, Baltimore, Maryland, USA
5 shared publications Ajit Puri
Department of Radiology, University of Massachusetts Memorial Medical Center, Worcester, USA
3 shared publications- Huanwen Chen
Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA
3 shared publications
Latest Publications
- 6 January 2025
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 249, 108722
The PANDA score: External validation and modification of a simple upfront prediction tool for poor outcomes despite successful stroke thrombectomy
- 6 January 2025
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 249, 108722
The PANDA score: External validation and modification of a simple upfront prediction tool for poor outcomes despite successful stroke thrombectomy
- 28 March 2024
- Published by Elsevier in World Neurosurgery
- Vol. 186, e283-e289
Optimal Angiographic Goal and Number of Passes for Octogenarians Undergoing Endovascular Stroke Thrombectomy
- 28 March 2024
- Published by Elsevier in World Neurosurgery
- Vol. 186, e283-e289
Optimal Angiographic Goal and Number of Passes for Octogenarians Undergoing Endovascular Stroke Thrombectomy
- 28 January 2024
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 33 (5) , 107608
The BAND score: A simple model for upfront prediction of poor outcomes despite successful stroke thrombectomy
- 28 January 2024
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 33 (5) , 107608
The BAND score: A simple model for upfront prediction of poor outcomes despite successful stroke thrombectomy
- Open Access
- 1 January 2023
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 138 (1) , 233-240
Target Ultra and Nano coils in the endovascular treatment of small intracranial aneurysms (ULTRA Registry)
OBJECTIVE: The ULTRA Registry is a national multicenter prospective study designed to assess aneurysm occlusion rates and safety profiles of the Target Ultra and Nano coils in the treatment of small intracranial aneurysms (IAs). METHODS: Patients with small (≤ 5 mm) ruptured and unruptured IAs were treated exclusively with Target Ultra and Nano coils. The primary endpoints were the initial rate of complete or near-complete aneurysm occlusion, aneurysm recurrence, and need for retreatment. Secondary endpoints were device- and procedure-related adverse events, hemorrhage from the coiled aneurysm at any time during follow-up, and clinical outcomes. RESULTS: The ULTRA Registry included 100 patients with a mean ± SD age of 56 ± 11.6 years, of whom 75 were women and 48 presented after aneurysm rupture. The mean aneurysm size was (3.5 ± 0.9) × (2.8 ± 0.9) × (3.0 ± 1.0) mm, and the mean packing density was 34.4% ± 16.7%. Posttreatment complete or near-complete occlusion reported by an independent imaging core laboratory was seen in 92% of patients at baseline and in 87%, 87%, and 83% of patients at first, second, and final follow-up, respectively. At first, second, and final follow-up, 10%, 11%, and 15%, respectively, of patients were deemed to require retreatment. There were three procedural-related ischemic strokes and one intracranial hemorrhage from wire perforation of a parent artery not involved by the aneurysm. There were no coil-related adverse events, including no intraoperative aneurysm ruptures and no known aneurysm ruptures after coiling. CONCLUSIONS: This assessment of aneurysm occlusion rates and safety profiles in ULTRA Registry study participants demonstrates excellent safety and efficacy profiles for Target Ultra and Nano coils in the treatment of small IAs.
- 1 January 2023
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 138 (1) , 233-240
Open AccessTarget Ultra and Nano coils in the endovascular treatment of small intracranial aneurysms (ULTRA Registry)
OBJECTIVE: The ULTRA Registry is a national multicenter prospective study designed to assess aneurysm occlusion rates and safety profiles of the Target Ultra and Nano coils in the treatment of small intracranial aneurysms (IAs). METHODS: Patients with small (≤ 5 mm) ruptured and unruptured IAs were treated exclusively with Target Ultra and Nano coils. The primary endpoints were the initial rate of complete or near-complete aneurysm occlusion, aneurysm recurrence, and need for retreatment. Secondary endpoints were device- and procedure-related adverse events, hemorrhage from the coiled aneurysm at any time during follow-up, and clinical outcomes. RESULTS: The ULTRA Registry included 100 patients with a mean ± SD age of 56 ± 11.6 years, of whom 75 were women and 48 presented after aneurysm rupture. The mean aneurysm size was (3.5 ± 0.9) × (2.8 ± 0.9) × (3.0 ± 1.0) mm, and the mean packing density was 34.4% ± 16.7%. Posttreatment complete or near-complete occlusion reported by an independent imaging core laboratory was seen in 92% of patients at baseline and in 87%, 87%, and 83% of patients at first, second, and final follow-up, respectively. At first, second, and final follow-up, 10%, 11%, and 15%, respectively, of patients were deemed to require retreatment. There were three procedural-related ischemic strokes and one intracranial hemorrhage from wire perforation of a parent artery not involved by the aneurysm. There were no coil-related adverse events, including no intraoperative aneurysm ruptures and no known aneurysm ruptures after coiling. CONCLUSIONS: This assessment of aneurysm occlusion rates and safety profiles in ULTRA Registry study participants demonstrates excellent safety and efficacy profiles for Target Ultra and Nano coils in the treatment of small IAs.
- Open Access
- 4 August 2020
- Published by BMJ
- Vol. 12 (Suppl 1) , A17.1-A17
O-024 Four or more thrombectomy passes, tPA use, and high initial stress glucose ratio are independently associated with malignant cerebral edema after mechanical thrombectomy: a single-center, retrospective study
Background The development of malignant cerebral edema (MCE) after large-vessel occlusion mechanical thrombectomy (MT) with the ensuing requirement for decompressive craniectomy is a dreaded outcome of stroke. We analyzed factors associated with the development of malignant cerebral edema following mechanical thrombectomy. Methods We performed a retrospective analysis of anterior cerebral circulation large vessel occlusion cases that underwent MT from April 2012 to November 2019 at single comprehensive stroke center. Data included patient demographics, presenting NIHSS score, vessel occlusion site, onset-to-revascularization timing, presenting blood glucose, 90 day modified Rankin Scale (mRS), post-procedural intracerebral hemorrhage (PH1 or PH2), and post-procedural development of MCE (midline shift greater than 5 mm associated with neurological deterioration after greater than 50% infarction of the MCA territory). Multi-variate logistic regression analyses were performed to determine significant predictors of malignant „cerebral edema and poor functional outcome (mRS 3–6) at 90 days. Results 400 patients were included in the analysis. 42 (10.5%) patients developed MCE following mechanical thrombectomy with 26 (6.5%) patients undergoing decompressive craniectomy. Significant independent predictors of MCE following MT included: NIHSS (OR 1.10, 95% CI: 1.03–1.18; p=0.008), tPA administration (OR 2.38 95% CI: 1.04–5.46; p=0.041), 4 or more thrombectomy passes (OR 5.25, 95% CI: 1.53–17.94; p=0.008), and initial stress glucose ratio (OR 14.92 95% CI: 3.95–56.43; pConclusion Our data demonstrate an association of malignant cerebral edema with ICA occlusion, higher presenting NIHSS scores, tPA administration, 4 or more thrombectomy passes, and a high initial stress glucose ratio. Malignant cerebral edema is associated with poor functional outcome at 90 days. Further investigation of causes of malignant cerebral edema after MT are warranted. Disclosures G. Cannarsa: None. A. Wessell: None. T. Chryssikos: None. K. Kim: None. J. Stokum: None. H. Carvalho: None. T. Miller: None. D. Gandhi: None. G. Jindal: None.
- 4 August 2020
- Published by BMJ
- Vol. 12 (Suppl 1) , A17.1-A17
Open AccessO-024 Four or more thrombectomy passes, tPA use, and high initial stress glucose ratio are independently associated with malignant cerebral edema after mechanical thrombectomy: a single-center, retrospective study
Background The development of malignant cerebral edema (MCE) after large-vessel occlusion mechanical thrombectomy (MT) with the ensuing requirement for decompressive craniectomy is a dreaded outcome of stroke. We analyzed factors associated with the development of malignant cerebral edema following mechanical thrombectomy. Methods We performed a retrospective analysis of anterior cerebral circulation large vessel occlusion cases that underwent MT from April 2012 to November 2019 at single comprehensive stroke center. Data included patient demographics, presenting NIHSS score, vessel occlusion site, onset-to-revascularization timing, presenting blood glucose, 90 day modified Rankin Scale (mRS), post-procedural intracerebral hemorrhage (PH1 or PH2), and post-procedural development of MCE (midline shift greater than 5 mm associated with neurological deterioration after greater than 50% infarction of the MCA territory). Multi-variate logistic regression analyses were performed to determine significant predictors of malignant „cerebral edema and poor functional outcome (mRS 3–6) at 90 days. Results 400 patients were included in the analysis. 42 (10.5%) patients developed MCE following mechanical thrombectomy with 26 (6.5%) patients undergoing decompressive craniectomy. Significant independent predictors of MCE following MT included: NIHSS (OR 1.10, 95% CI: 1.03–1.18; p=0.008), tPA administration (OR 2.38 95% CI: 1.04–5.46; p=0.041), 4 or more thrombectomy passes (OR 5.25, 95% CI: 1.53–17.94; p=0.008), and initial stress glucose ratio (OR 14.92 95% CI: 3.95–56.43; pConclusion Our data demonstrate an association of malignant cerebral edema with ICA occlusion, higher presenting NIHSS scores, tPA administration, 4 or more thrombectomy passes, and a high initial stress glucose ratio. Malignant cerebral edema is associated with poor functional outcome at 90 days. Further investigation of causes of malignant cerebral edema after MT are warranted. Disclosures G. Cannarsa: None. A. Wessell: None. T. Chryssikos: None. K. Kim: None. J. Stokum: None. H. Carvalho: None. T. Miller: None. D. Gandhi: None. G. Jindal: None.
- 15 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (5) , 822-827
A Critical Assessment of the Golden Hour and the Impact of Procedural Timing in Stroke Thrombectomy
BACKGROUND AND PURPOSE: Previous studies in acute ischemic stroke have demonstrated the importance of minimizing delays to endovascular treatment and keeping thrombectomy procedural times at 6 hours). Clinical characteristics of patients with postprocedural intracranial hemorrhage were also assessed. Logistic regression was used to determine independent predictors of poor outcome at 90 days (mRS ≥3). RESULTS: Greater age (OR, 1.03; 95% CI, 1.01–1.06; P = .016), higher admission NIHSS score (OR, 1.10; 95% CI, 1.04–1.16; P = .001), history of diabetes mellitus (OR, 1.96; 95% CI, 1.05–3.65; P = .034), and postprocedural intracranial hemorrhage were independently associated with greater odds of poor outcome. Modified TICI scale scores of 2c (OR, 0.11; 95% CI, 0.04–0.28; P < .001) and 3 (OR, 0.15; 95% CI, 0.06–0.38; P < .001) were associated with reduced odds of poor outcome. Although not statistically significant on univariate analysis, onset to endovascular therapy of >6 hours was independently associated with increased odds of poor outcome (OR, 2.20; 95% CI, 1.11–4.36; P = .024) in the final multivariate model (area under the curve = 0.820). Procedural time was not independently associated with clinical outcome in the final multivariate model (P > .05). CONCLUSIONS: Thrombectomy procedural times beyond 60 minutes are associated with lower revascularization rates and worse 90-day outcomes. Procedural time itself was not an independent predictor of outcome. While stroke thrombectomy procedures should be performed rapidly, our study emphasizes the significance of achieving revascularization despite the requisite procedural time. However, the potential for revascularization must be weighed against the risks associated with multiple thrombectomy attempts.
- 15 May 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (5) , 822-827
A Critical Assessment of the Golden Hour and the Impact of Procedural Timing in Stroke Thrombectomy
BACKGROUND AND PURPOSE: Previous studies in acute ischemic stroke have demonstrated the importance of minimizing delays to endovascular treatment and keeping thrombectomy procedural times at 6 hours). Clinical characteristics of patients with postprocedural intracranial hemorrhage were also assessed. Logistic regression was used to determine independent predictors of poor outcome at 90 days (mRS ≥3). RESULTS: Greater age (OR, 1.03; 95% CI, 1.01–1.06; P = .016), higher admission NIHSS score (OR, 1.10; 95% CI, 1.04–1.16; P = .001), history of diabetes mellitus (OR, 1.96; 95% CI, 1.05–3.65; P = .034), and postprocedural intracranial hemorrhage were independently associated with greater odds of poor outcome. Modified TICI scale scores of 2c (OR, 0.11; 95% CI, 0.04–0.28; P < .001) and 3 (OR, 0.15; 95% CI, 0.06–0.38; P < .001) were associated with reduced odds of poor outcome. Although not statistically significant on univariate analysis, onset to endovascular therapy of >6 hours was independently associated with increased odds of poor outcome (OR, 2.20; 95% CI, 1.11–4.36; P = .024) in the final multivariate model (area under the curve = 0.820). Procedural time was not independently associated with clinical outcome in the final multivariate model (P > .05). CONCLUSIONS: Thrombectomy procedural times beyond 60 minutes are associated with lower revascularization rates and worse 90-day outcomes. Procedural time itself was not an independent predictor of outcome. While stroke thrombectomy procedures should be performed rapidly, our study emphasizes the significance of achieving revascularization despite the requisite procedural time. However, the potential for revascularization must be weighed against the risks associated with multiple thrombectomy attempts.
- Open Access
- 1 November 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (12) , 2270-2277
Pipeline Diameter Significantly Impacts the Long-Term Fate of Jailed Side Branches during Treatment of Intracranial Aneurysms
BACKGROUND AND PURPOSE: Although covered side branches typically remain patent acutely following Pipeline Embolization Device embolization of intracranial aneurysms, the long-term fate of these vessels remains uncertain. We therefore elected to investigate factors that may influence the long-term patency of these covered side branches. MATERIALS AND METHODS: We retrospectively evaluated the long-term patency of side branches covered by the Pipeline Embolization Device at our institution during treatment of intracranial aneurysms with at least 6 months of conventional angiography follow-up. Procedural and anatomic factors that might influence the fate of covered side branches were explored. RESULTS: One hundred forty-eight Pipeline Embolization Device treatments in 137 patients met the inclusion criteria. In 217 covered side branches, 29 (13.4%) were occluded on follow-up, and 40 (18.4%) were stenotic. All stenoses and occlusions were asymptomatic. In the entire cohort and in the largest subset of ophthalmic arteries, a smaller Pipeline Embolization Device diameter was associated with branch vessel occlusion (P = .001, P = .013). When we considered stenotic and occluded side branches together, smaller Pipeline Embolization Device size (P = .029) and administration of intraprocedural abciximab (P = .03) predicted side branch stenosis/occlusion, while anterior choroidal branch type (P = .003) was a predictor of gross side branch patency. CONCLUSIONS: A smaller Pipeline Embolization Device diameter is associated with delayed side branch stenosis/occlusion following Pipeline Embolization Device treatment, likely due to the higher metal density of smaller caliber devices. Although hemodynamic factors, including the potential for collateral flow, are still paramount in determining the fate of covered side branches, the amount of metal coverage at the side branch orifice also plays an important role.
- 1 November 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (12) , 2270-2277
Open AccessPipeline Diameter Significantly Impacts the Long-Term Fate of Jailed Side Branches during Treatment of Intracranial Aneurysms
BACKGROUND AND PURPOSE: Although covered side branches typically remain patent acutely following Pipeline Embolization Device embolization of intracranial aneurysms, the long-term fate of these vessels remains uncertain. We therefore elected to investigate factors that may influence the long-term patency of these covered side branches. MATERIALS AND METHODS: We retrospectively evaluated the long-term patency of side branches covered by the Pipeline Embolization Device at our institution during treatment of intracranial aneurysms with at least 6 months of conventional angiography follow-up. Procedural and anatomic factors that might influence the fate of covered side branches were explored. RESULTS: One hundred forty-eight Pipeline Embolization Device treatments in 137 patients met the inclusion criteria. In 217 covered side branches, 29 (13.4%) were occluded on follow-up, and 40 (18.4%) were stenotic. All stenoses and occlusions were asymptomatic. In the entire cohort and in the largest subset of ophthalmic arteries, a smaller Pipeline Embolization Device diameter was associated with branch vessel occlusion (P = .001, P = .013). When we considered stenotic and occluded side branches together, smaller Pipeline Embolization Device size (P = .029) and administration of intraprocedural abciximab (P = .03) predicted side branch stenosis/occlusion, while anterior choroidal branch type (P = .003) was a predictor of gross side branch patency. CONCLUSIONS: A smaller Pipeline Embolization Device diameter is associated with delayed side branch stenosis/occlusion following Pipeline Embolization Device treatment, likely due to the higher metal density of smaller caliber devices. Although hemodynamic factors, including the potential for collateral flow, are still paramount in determining the fate of covered side branches, the amount of metal coverage at the side branch orifice also plays an important role.
- 1 November 2018
- Published by Elsevier in World Neurosurgery
- Vol. 119, e928-e933
Functional Independence After Stroke Thrombectomy Using Thrombolysis In Cerebral Infarction Grade 2c: A New Aim of Successful Revascularization
- 1 November 2018
- Published by Elsevier in World Neurosurgery
- Vol. 119, e928-e933
Functional Independence After Stroke Thrombectomy Using Thrombolysis In Cerebral Infarction Grade 2c: A New Aim of Successful Revascularization
- 1 January 2017
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 55 (1) , 151-166
Imaging Evaluation and Treatment of Vascular Lesions at the Skull Base
- 1 January 2017
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 55 (1) , 151-166
Imaging Evaluation and Treatment of Vascular Lesions at the Skull Base
- Open Access
- 22 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 450-454
The Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study
BACKGROUND AND PURPOSE: Neurointerventional surgery may expose patients and physician operators to substantial amounts of ionizing radiation. Although strategies for reducing patient exposure have been explored in the medical literature, there has been relatively little published in regards to decreasing operator exposure. The purpose of this study was to evaluate the efficacy of shielding systems in reducing physician exposure in a modern neurointerventional practice. MATERIALS AND METHODS: Informed consent was obtained from operators for this Health Insurance Portability and Accountability Act–compliant, institutional review board–approved study. Operator radiation exposure was prospectively measured during 60 consecutive neurointerventional procedures from October to November 2013 using a 3-part lead shielding system. Exposure was then evaluated without lead shielding in a second 60-procedure block from April to May 2014. A radiation protection drape was randomly selected for use in half of the cases in each block. Two-way analysis of covariance was performed to test the effect of shielding systems on operator exposure while controlling for other covariates, including procedure dose-area product. RESULTS: Mean operator procedure dose was 20.6 μSv for the entire cohort and 17.7 μSv when using some type of shielding. Operator exposure significantly correlated with procedure dose-area product, but not with other covariates. After we adjusted for procedure dose-area product, the use of lead shielding or a radiation protection drape significantly reduced operator exposure by 45% (F = 12.54, P < .0001) and 29% (F = 7.02, P = .009), respectively. The difference in protection afforded by these systems was not statistically significant (P = .46), and their adjunctive use did not provide additional protection. CONCLUSIONS: Extensive lead shielding should be used as much as possible in neurointerventional surgery to reduce operator radiation exposure to acceptable levels. A radiation protection drape is a reasonable alternative when standard lead shielding is unavailable or impractical to use without neglecting strategies to minimize the dose.
- 22 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (3) , 450-454
Open AccessThe Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study
BACKGROUND AND PURPOSE: Neurointerventional surgery may expose patients and physician operators to substantial amounts of ionizing radiation. Although strategies for reducing patient exposure have been explored in the medical literature, there has been relatively little published in regards to decreasing operator exposure. The purpose of this study was to evaluate the efficacy of shielding systems in reducing physician exposure in a modern neurointerventional practice. MATERIALS AND METHODS: Informed consent was obtained from operators for this Health Insurance Portability and Accountability Act–compliant, institutional review board–approved study. Operator radiation exposure was prospectively measured during 60 consecutive neurointerventional procedures from October to November 2013 using a 3-part lead shielding system. Exposure was then evaluated without lead shielding in a second 60-procedure block from April to May 2014. A radiation protection drape was randomly selected for use in half of the cases in each block. Two-way analysis of covariance was performed to test the effect of shielding systems on operator exposure while controlling for other covariates, including procedure dose-area product. RESULTS: Mean operator procedure dose was 20.6 μSv for the entire cohort and 17.7 μSv when using some type of shielding. Operator exposure significantly correlated with procedure dose-area product, but not with other covariates. After we adjusted for procedure dose-area product, the use of lead shielding or a radiation protection drape significantly reduced operator exposure by 45% (F = 12.54, P < .0001) and 29% (F = 7.02, P = .009), respectively. The difference in protection afforded by these systems was not statistically significant (P = .46), and their adjunctive use did not provide additional protection. CONCLUSIONS: Extensive lead shielding should be used as much as possible in neurointerventional surgery to reduce operator radiation exposure to acceptable levels. A radiation protection drape is a reasonable alternative when standard lead shielding is unavailable or impractical to use without neglecting strategies to minimize the dose.