Ann Sofia Skou Thomsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ann Sofia Skou Thomsen has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Lars Konge
Copenhagen Academy for Medical Education and Simulation Denmark Denmark
19 shared publicationsMorten la Cour
Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark
8 shared publications- Morten la Cour
Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark
8 shared publications - Mads Forslund Jacobsen
Department of Ophthalmology Rigshospitalet – Glostrup Glostrup Denmark
7 shared publications - Yousif Subhi
Department of Ophthalmology University Hospital of Southern Denmark Sønderborg Denmark
7 shared publications - Asbjørn Hróbjartsson
The Nordic Cochrane Centre, Rigshospitalet, Copenhagen, Denmark
4 shared publications
Latest Publications
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1202-1207
Phacoemulsification to manual small-incision cataract surgery: transfer of skills study in a simulated environment
Purpose: To investigate whether phacoemulsification (PE) experience impacts and transfers to the skill acquisition of novices in manual small-incision cataract surgery (MSICS) within a simulation environment. Setting: Copenhagen Academy for Medical Education and Simulation, Copenhagen, Denmark. Design: Prospective controlled experimental study. Methods: The study included 29 residents or specialist in ophthalmology with no prior MSICS experience. Participants were required to have either (1) proficiency on the EyeSi surgical simulator (PE group [PG]) or (2) no prior extensive exposure to the EyeSi simulator or any PE surgery experience as a primary surgeon (control group [CG]). Possible skill transfer was assessed using a test on the HelpMeSee virtual-reality simulator, including 9 modules and 30 steps (points). A pass/fail score was determined at 20 points (of 30 points). Performance scores were analyzed using independent samples t tests, pass rates using the Fisher exact test, and individual modules using Fisher-Freeman-Halton analysis. Results: The PG performed significantly better in overall performance score (mean ± SD, PG; 21.8 points ± 2.3 vs CG; 18.9 points ± 2.2, P = .002, t-value = −3.39) and pass rates (PG; 72% vs CG; 22%, P = .018). The subanalysis for individual modules demonstrated significant differences exclusively in the capsulorhexis and cortex removal modules. Conclusions: The results suggest a positive interprocedural transfer of skills between PE and MSICS. Pretraining and experience in PE demonstrated a significant effect on the performance of MSICS within a simulation environment. These findings suggest that PE experience provides an advantage before MSICS training in surgical residency programs.
- 1 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (12) , 1202-1207
Phacoemulsification to manual small-incision cataract surgery: transfer of skills study in a simulated environment
Purpose: To investigate whether phacoemulsification (PE) experience impacts and transfers to the skill acquisition of novices in manual small-incision cataract surgery (MSICS) within a simulation environment. Setting: Copenhagen Academy for Medical Education and Simulation, Copenhagen, Denmark. Design: Prospective controlled experimental study. Methods: The study included 29 residents or specialist in ophthalmology with no prior MSICS experience. Participants were required to have either (1) proficiency on the EyeSi surgical simulator (PE group [PG]) or (2) no prior extensive exposure to the EyeSi simulator or any PE surgery experience as a primary surgeon (control group [CG]). Possible skill transfer was assessed using a test on the HelpMeSee virtual-reality simulator, including 9 modules and 30 steps (points). A pass/fail score was determined at 20 points (of 30 points). Performance scores were analyzed using independent samples t tests, pass rates using the Fisher exact test, and individual modules using Fisher-Freeman-Halton analysis. Results: The PG performed significantly better in overall performance score (mean ± SD, PG; 21.8 points ± 2.3 vs CG; 18.9 points ± 2.2, P = .002, t-value = −3.39) and pass rates (PG; 72% vs CG; 22%, P = .018). The subanalysis for individual modules demonstrated significant differences exclusively in the capsulorhexis and cortex removal modules. Conclusions: The results suggest a positive interprocedural transfer of skills between PE and MSICS. Pretraining and experience in PE demonstrated a significant effect on the performance of MSICS within a simulation environment. These findings suggest that PE experience provides an advantage before MSICS training in surgical residency programs.
- Open Access
- 31 May 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 102 (8) , 906-913
Comparing the impact of surgical expert versus non‐ophthalmologist instructors on virtual‐reality surgical performance: A randomized controlled trial
Purpose: To compare Manual Small Incision Cataract Surgery (MSICS) microsurgical performance in course participants who received virtual reality simulation‐based training by either a surgical expert or a non‐ophthalmologist instructor.Setting: Copenhagen Academy for Medical Education and Simulation, Copenhagen, Denmark.Design: Randomized controlled trial.Methods: Residents and specialists in ophthalmology with no prior MSICS experience were included to receive virtual reality simulation training in MSICS using the HelpMeSee simulator. The participants were randomly allocated to receive training from either an experienced MSICS surgeon or a non‐ophthalmologist, also known as near‐peer teaching. The performances of the participants were evaluated at baseline and post‐training using a MSICS proficiency‐based test with evidence of validity.Results: Thirty participants were included in the study and 29 completed the course. There was no significant difference in final test score between the two groups (p = 0.13). The performance score of both groups of participants increased significantly after receiving the training (p < 0.001). All participants passed the proficiency‐based test after receiving the training.Conclusion: We found no significant difference in surgical proficiency‐level whether the participants were trained by a surgical expert or a non‐ophthalmologist instructor for MSICS in a virtual‐reality based setting. The findings of this study suggest that near‐peer teaching within microsurgical performance potentially could be applied with teaching outcomes comparable to a surgical expert‐instructor.
- 31 May 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 102 (8) , 906-913
Open AccessComparing the impact of surgical expert versus non‐ophthalmologist instructors on virtual‐reality surgical performance: A randomized controlled trial
Purpose: To compare Manual Small Incision Cataract Surgery (MSICS) microsurgical performance in course participants who received virtual reality simulation‐based training by either a surgical expert or a non‐ophthalmologist instructor.Setting: Copenhagen Academy for Medical Education and Simulation, Copenhagen, Denmark.Design: Randomized controlled trial.Methods: Residents and specialists in ophthalmology with no prior MSICS experience were included to receive virtual reality simulation training in MSICS using the HelpMeSee simulator. The participants were randomly allocated to receive training from either an experienced MSICS surgeon or a non‐ophthalmologist, also known as near‐peer teaching. The performances of the participants were evaluated at baseline and post‐training using a MSICS proficiency‐based test with evidence of validity.Results: Thirty participants were included in the study and 29 completed the course. There was no significant difference in final test score between the two groups (p = 0.13). The performance score of both groups of participants increased significantly after receiving the training (p < 0.001). All participants passed the proficiency‐based test after receiving the training.Conclusion: We found no significant difference in surgical proficiency‐level whether the participants were trained by a surgical expert or a non‐ophthalmologist instructor for MSICS in a virtual‐reality based setting. The findings of this study suggest that near‐peer teaching within microsurgical performance potentially could be applied with teaching outcomes comparable to a surgical expert‐instructor.
- Open Access
- 30 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
A validated test has been developed for assessment of manual small incision cataract surgery skills using virtual reality simulation
This study investigates the validity evidence of metrics used for the assessment of surgical skills for Manual Small Incision Cataract Surgery (MSICS) in a virtual reality simulator. MSICS surgery is a low-cost, low-technology cataract surgery technique, which is widely used in low- and middle-income countries. However, there is a lack of cataract surgeons globally, and efficient and evidence-based training of new surgeons is needed. In order to investigate the validity of simulator metrics, we included three groups of participants: (1) MSICS novices who were ophthalmologists with no cataract surgery experience, (2) MSICS novices who were experienced phacoemulsification cataract surgeons, but with no MSICS experience, and (3) experienced phacoemulsification and MSICS surgeons. The evaluation included 11 steps of the MSICS procedure, and all simulator metrics for those steps were reviewed. Of the 55 initial metrics, 30 showed high positive discriminative ability. A test passing score of 20 out of 30 was established, and one of 15 novices with no MSICS experience (mean score 15.5) and 7 out of 10 experienced MSICS surgeons (mean score 22.7) passed the test. We have developed and established validity evidence for a test for MSICS skills in a virtual reality simulator for future use in proficiency-based training and evidence-based testing of training interventions.
- 30 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Open AccessA validated test has been developed for assessment of manual small incision cataract surgery skills using virtual reality simulation
This study investigates the validity evidence of metrics used for the assessment of surgical skills for Manual Small Incision Cataract Surgery (MSICS) in a virtual reality simulator. MSICS surgery is a low-cost, low-technology cataract surgery technique, which is widely used in low- and middle-income countries. However, there is a lack of cataract surgeons globally, and efficient and evidence-based training of new surgeons is needed. In order to investigate the validity of simulator metrics, we included three groups of participants: (1) MSICS novices who were ophthalmologists with no cataract surgery experience, (2) MSICS novices who were experienced phacoemulsification cataract surgeons, but with no MSICS experience, and (3) experienced phacoemulsification and MSICS surgeons. The evaluation included 11 steps of the MSICS procedure, and all simulator metrics for those steps were reviewed. Of the 55 initial metrics, 30 showed high positive discriminative ability. A test passing score of 20 out of 30 was established, and one of 15 novices with no MSICS experience (mean score 15.5) and 7 out of 10 experienced MSICS surgeons (mean score 22.7) passed the test. We have developed and established validity evidence for a test for MSICS skills in a virtual reality simulator for future use in proficiency-based training and evidence-based testing of training interventions.
- 22 September 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 100 (4) , 440-446
Quantifying surgical skill in macular surgery
Purpose: To evaluate the relationship between patient outcome and surgical experience by developing an objective quality measure of macular hole surgery based on forceps damage to the inner retina.Methods: We retrospectively examined 3 macular hole case series >1 year after pars plana vitrectomy, internal limiting membrane peeling and gas tamponade. The patients were operated by (1) a novice surgeon (6 μm3 (IQR: 22.77 × 106–44.81 × 106 μm3), 8.42 × 106 μm3 (IQR: 4.86 × 106–10.03 × 106 μm3) and 3.55 × 106 μm3 (IQR: 1.44 × 103–7.94 × 106 μm3) in the novice, intermediate and experienced surgeon group, respectively (p = 0.0004). The novice surgeon volume defect differed significantly from the intermediate and experienced surgeon (p = 0.016 and p = 0.0002, respectively). A subset of 12 patients underwent microperimetry measurements demonstrating correlation between inner retinal volume defect and reduced retinal sensitivity (p = 0.02).Conclusions: Forceps induced inner retinal damage commonly occurs during initiation of internal limiting membrane peeling in macular hole surgery. Damage to the structure and function of the inner retina seems to correlate to surgical experience.
- 22 September 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 100 (4) , 440-446
Quantifying surgical skill in macular surgery
Purpose: To evaluate the relationship between patient outcome and surgical experience by developing an objective quality measure of macular hole surgery based on forceps damage to the inner retina.Methods: We retrospectively examined 3 macular hole case series >1 year after pars plana vitrectomy, internal limiting membrane peeling and gas tamponade. The patients were operated by (1) a novice surgeon (6 μm3 (IQR: 22.77 × 106–44.81 × 106 μm3), 8.42 × 106 μm3 (IQR: 4.86 × 106–10.03 × 106 μm3) and 3.55 × 106 μm3 (IQR: 1.44 × 103–7.94 × 106 μm3) in the novice, intermediate and experienced surgeon group, respectively (p = 0.0004). The novice surgeon volume defect differed significantly from the intermediate and experienced surgeon (p = 0.016 and p = 0.0002, respectively). A subset of 12 patients underwent microperimetry measurements demonstrating correlation between inner retinal volume defect and reduced retinal sensitivity (p = 0.02).Conclusions: Forceps induced inner retinal damage commonly occurs during initiation of internal limiting membrane peeling in macular hole surgery. Damage to the structure and function of the inner retina seems to correlate to surgical experience.
- 1 March 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (8) , E1509-E1516
The learning curve of robot‐assisted vitreoretinal surgery – A randomized trial in a simulated setting
Purpose: To investigate the learning curve of robot‐assisted vitreoretinal surgery compared to manual surgery in a simulated setting.Methods: The study was designed as a randomized controlled longitudinal study. Eight ophthalmic trainees in the 1st or 2nd year of their specialization were included. The participants were randomized to either manual or robot‐assisted surgery. Participants completed repetitions of a test consisting of three vitreoretinal modules on the Eyesi virtual reality simulator. The primary outcome measure was time to learning curve plateau (minutes) for total test score. The secondary outcome measures were instrument movement (mm), tissue treatment (mm2) and time with instruments inserted (seconds).Results: There was no significant difference in time to learning curve plateau for robot‐assisted vitreoretinal surgery compared to manual. Robot‐assisted vitreoretinal surgery was associated with less instrument movements (i.e. improved precision), −0.91 standard deviation (SD) units (p < 0.001). Furthermore, robot‐assisted vitreoretinal surgery was associated with less tissue damage when compared to manual surgery, −0.94 SD units (p = 0.002). Lastly, robot‐assisted vitreoretinal surgery was slower than manual surgery, 0.93 SD units (p < 0.001).Conclusions: There was no significant difference between the lengths of the learning curves for robot‐assisted vitreoretinal surgery compared to manual surgery. Robot‐assisted vitreoretinal surgery was more precise, associated with less tissue damage, and slower.
- 1 March 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (8) , E1509-E1516
The learning curve of robot‐assisted vitreoretinal surgery – A randomized trial in a simulated setting
Purpose: To investigate the learning curve of robot‐assisted vitreoretinal surgery compared to manual surgery in a simulated setting.Methods: The study was designed as a randomized controlled longitudinal study. Eight ophthalmic trainees in the 1st or 2nd year of their specialization were included. The participants were randomized to either manual or robot‐assisted surgery. Participants completed repetitions of a test consisting of three vitreoretinal modules on the Eyesi virtual reality simulator. The primary outcome measure was time to learning curve plateau (minutes) for total test score. The secondary outcome measures were instrument movement (mm), tissue treatment (mm2) and time with instruments inserted (seconds).Results: There was no significant difference in time to learning curve plateau for robot‐assisted vitreoretinal surgery compared to manual. Robot‐assisted vitreoretinal surgery was associated with less instrument movements (i.e. improved precision), −0.91 standard deviation (SD) units (p < 0.001). Furthermore, robot‐assisted vitreoretinal surgery was associated with less tissue damage when compared to manual surgery, −0.94 SD units (p = 0.002). Lastly, robot‐assisted vitreoretinal surgery was slower than manual surgery, 0.93 SD units (p < 0.001).Conclusions: There was no significant difference between the lengths of the learning curves for robot‐assisted vitreoretinal surgery compared to manual surgery. Robot‐assisted vitreoretinal surgery was more precise, associated with less tissue damage, and slower.
- 30 December 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (7) , E999-E1005
Defining the surgical footprint in cataract surgery: patient‐related outcomes dependent on the experience of the surgeon
Purpose: To investigate which patient‐related outcomes are dependent on the experience of the cataract surgeon.Methods: The study was designed as a prospective observational study. Novice (1000 surgeries performed) cataract surgeons from the Department of Ophthalmology, Rigshospitalet – Glostrup and Nordsjællands Hospital – Hillerød were included in the study. Patients operated by the included surgeons were examined preoperatively, 1 day, 3 days, and 3 weeks after standard, noncomplicated cataract surgery. Primary outcomes were change in central corneal thickness and endothelial cell loss. Secondary outcomes were best‐corrected visual acuity, intraocular pressure, aqueous flare, central macular thickness, and surgical complications.Results: Surgery performed by novice surgeons resulted in significantly lower visual acuity (mean −3.6 letters (Early Treatment Diabetic Retinopathy Study (ETDRS)); 95% CI: −7.3; −0.4, p = 0.03) and greater corneal thickness (mean 26.7 µm; 95% CI: 6.8; 46.6, p = 0.01) on the first day postoperative than surgery performed by experienced surgeons.Conclusion: The experience of the cataract surgeon affected visual acuity and central corneal thickness in the immediate postoperative period. In the future, these patient‐related outcomes may be used to assess the technical proficiency of surgical trainees and investigate the effect of different training programs.
- 30 December 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (7) , E999-E1005
Defining the surgical footprint in cataract surgery: patient‐related outcomes dependent on the experience of the surgeon
Purpose: To investigate which patient‐related outcomes are dependent on the experience of the cataract surgeon.Methods: The study was designed as a prospective observational study. Novice (1000 surgeries performed) cataract surgeons from the Department of Ophthalmology, Rigshospitalet – Glostrup and Nordsjællands Hospital – Hillerød were included in the study. Patients operated by the included surgeons were examined preoperatively, 1 day, 3 days, and 3 weeks after standard, noncomplicated cataract surgery. Primary outcomes were change in central corneal thickness and endothelial cell loss. Secondary outcomes were best‐corrected visual acuity, intraocular pressure, aqueous flare, central macular thickness, and surgical complications.Results: Surgery performed by novice surgeons resulted in significantly lower visual acuity (mean −3.6 letters (Early Treatment Diabetic Retinopathy Study (ETDRS)); 95% CI: −7.3; −0.4, p = 0.03) and greater corneal thickness (mean 26.7 µm; 95% CI: 6.8; 46.6, p = 0.01) on the first day postoperative than surgery performed by experienced surgeons.Conclusion: The experience of the cataract surgeon affected visual acuity and central corneal thickness in the immediate postoperative period. In the future, these patient‐related outcomes may be used to assess the technical proficiency of surgical trainees and investigate the effect of different training programs.
- Open Access
- 24 August 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E617-E618
Telementoring and remote training in the present era
- 24 August 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (4) , E617-E618
Open AccessTelementoring and remote training in the present era
- Open Access
- 30 June 2020
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 15 (4) , 193-196
The future of virtual reality in cataract surgical training
(2020). The future of virtual reality in cataract surgical training. Expert Review of Ophthalmology. Ahead of Print.
- 30 June 2020
- Published by Taylor & Francis in Expert Review of Ophthalmology
- Vol. 15 (4) , 193-196
Open AccessThe future of virtual reality in cataract surgical training
(2020). The future of virtual reality in cataract surgical training. Expert Review of Ophthalmology. Ahead of Print.
- Open Access
- 18 April 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (7) , 687-692
Simulation of advanced cataract surgery – validation of a newly developed test
Purpose: To develop and investigate an Eyesi simulator‐based test for the more experienced cataract surgeon for evidence of validity.Methods: The study was a prospective interventional cohort study and carried out at the Copenhagen Academy for Medical Education and Simulation. The Eyesi Simulator was used for the test which was developed by three expert cataract surgeons. Ten cataract surgeons (>250 surgeries performed) and ten ophthalmic residents performed two repetitions of the test. The test consisted of four modules: Iris Expansion Ring insertion – level 1, Iris Expansion Ring extraction – level 2, Capsulorhexis – level 3 and Anterior Vitrectomy – level 6.Results: Internal consistency reliability showed Cronbach’s alpha of 0.63. Test–retest reliabilities were significant for Iris Expansion Ring extraction – level 2 (p = 0.012) and Capsulorhexis – level 3 (p = 0.018). Differences between the two groups were only significant in both repetitions for the Iris Expansion Ring extraction – level 2 (p < 0.001 and p = 0.041, respectively). Furthermore, we found a statistically significant difference between the mean module scores for novices and the more experienced surgeons for Iris Expansion Ring insertion – level 1 (p = 0.021) and Capsulorhexis – level 3 (p = 0.019) in the first repetition.Conclusion: The investigated modules show evidence of validity within several aspects of Messick’s framework. However, the evidence is not strong enough to apply the test for certification purposes of cataract surgeons, but the modules may still be relevant in the training of advanced cataract surgical procedures.
- 18 April 2020
- Published by Wiley in Acta Ophthalmologica
- Vol. 98 (7) , 687-692
Open AccessSimulation of advanced cataract surgery – validation of a newly developed test
Purpose: To develop and investigate an Eyesi simulator‐based test for the more experienced cataract surgeon for evidence of validity.Methods: The study was a prospective interventional cohort study and carried out at the Copenhagen Academy for Medical Education and Simulation. The Eyesi Simulator was used for the test which was developed by three expert cataract surgeons. Ten cataract surgeons (>250 surgeries performed) and ten ophthalmic residents performed two repetitions of the test. The test consisted of four modules: Iris Expansion Ring insertion – level 1, Iris Expansion Ring extraction – level 2, Capsulorhexis – level 3 and Anterior Vitrectomy – level 6.Results: Internal consistency reliability showed Cronbach’s alpha of 0.63. Test–retest reliabilities were significant for Iris Expansion Ring extraction – level 2 (p = 0.012) and Capsulorhexis – level 3 (p = 0.018). Differences between the two groups were only significant in both repetitions for the Iris Expansion Ring extraction – level 2 (p < 0.001 and p = 0.041, respectively). Furthermore, we found a statistically significant difference between the mean module scores for novices and the more experienced surgeons for Iris Expansion Ring insertion – level 1 (p = 0.021) and Capsulorhexis – level 3 (p = 0.019) in the first repetition.Conclusion: The investigated modules show evidence of validity within several aspects of Messick’s framework. However, the evidence is not strong enough to apply the test for certification purposes of cataract surgeons, but the modules may still be relevant in the training of advanced cataract surgical procedures.
- Open Access
- 13 December 2019
- Published by Wolters Kluwer Health in Retina
- Vol. 40 (11) , 2091-2098
ROBOT-ASSISTED VITREORETINAL SURGERY IMPROVES SURGICAL ACCURACY COMPARED WITH MANUAL SURGERY
Purpose: To compare manual and robot-assisted vitreoretinal surgery using a virtual-reality surgical simulator. Methods: Randomized controlled crossover study. Ten experienced vitreoretinal surgeons and 10 novice ophthalmic surgeons were included. The participants were randomized to start with either manual or robot-assisted surgery. Participants completed a test session consisting of three vitreoretinal modules on the Eyesi virtual-reality simulator. The automated metrics of performance supplied by the Eyesi simulator were used as outcome measures. Primary outcome measures were time with instruments inserted (seconds), instrument movement (mm), and tissue treatment (mm2). Results: Robot-assisted surgery was slower than manual surgery for both novices and vitreoretinal surgeons, 0.24 SD units (P = 0.024) and 0.73 SD units (P < 0.001), respectively. Robot-assisted surgery allowed for greater precision in novices and vitreoretinal surgeons, −0.96 SD units (P < 0.001) and −0.47 SD units (P < 0.001), respectively. Finally, novices using robot-assisted surgery inflicted less tissue damage when compared with that using manual surgery, −0.59 SD units (P = 0.009). Conclusion: At the cost of time, robot-assisted vitreoretinal surgery seems to improve precision and limit tissue damage compared with that of manual surgery. In particular, the performance of novice surgeons is enhanced with robot-assisted vitreoretinal surgery.
- 13 December 2019
- Published by Wolters Kluwer Health in Retina
- Vol. 40 (11) , 2091-2098
Open AccessROBOT-ASSISTED VITREORETINAL SURGERY IMPROVES SURGICAL ACCURACY COMPARED WITH MANUAL SURGERY
Purpose: To compare manual and robot-assisted vitreoretinal surgery using a virtual-reality surgical simulator. Methods: Randomized controlled crossover study. Ten experienced vitreoretinal surgeons and 10 novice ophthalmic surgeons were included. The participants were randomized to start with either manual or robot-assisted surgery. Participants completed a test session consisting of three vitreoretinal modules on the Eyesi virtual-reality simulator. The automated metrics of performance supplied by the Eyesi simulator were used as outcome measures. Primary outcome measures were time with instruments inserted (seconds), instrument movement (mm), and tissue treatment (mm2). Results: Robot-assisted surgery was slower than manual surgery for both novices and vitreoretinal surgeons, 0.24 SD units (P = 0.024) and 0.73 SD units (P < 0.001), respectively. Robot-assisted surgery allowed for greater precision in novices and vitreoretinal surgeons, −0.96 SD units (P < 0.001) and −0.47 SD units (P < 0.001), respectively. Finally, novices using robot-assisted surgery inflicted less tissue damage when compared with that using manual surgery, −0.59 SD units (P = 0.009). Conclusion: At the cost of time, robot-assisted vitreoretinal surgery seems to improve precision and limit tissue damage compared with that of manual surgery. In particular, the performance of novice surgeons is enhanced with robot-assisted vitreoretinal surgery.