Matthieu Glardon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matthieu Glardon has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Beat P. Kneubuehl
Institute of Forensic Medicine, University of Bern, Bern, Switzerland
4 shared publications- Beat P. Kneubuehl
Bpk consultancy gmbh
3 shared publications - Michael Hubert Stoffel
Division of Veterinary Anatomy, Vetsuisse Faculty, University of Bern, Bern, Switzerland
3 shared publications Rebecca Pircher
University Medical Center Freiburg, Freiburg, Germany
3 shared publicationsStefan Pollak
Institute of Legal Medicine, University Medical Center, Faculty of Medicine, University of Freiburg, Albertstraße 9, 79104, Freiburg, Germany
3 shared publications- Steffen G. Ross
Institute of Forensic Medicine, Forensic Medicine and Imaging, University of Zurich, Switzerland
3 shared publications
Latest Publications
- 9 July 2019
- Published by Springer Nature in International journal of legal medicine
- Vol. 134 (3) , 1007-1013
Influence of a soft tissue layer covering the kidney upon blunt impact
Blunt abdominal organ injury is an abundant and relevant topic in forensic medicine, yet comparatively few experimental studies have been performed to quantify organ injury threshold parameters. The goal of this study was to relate an impact to a kidney injury determining an energy threshold while taking account of the influence of the overlaying soft tissue thickness. A model consisting of ballistic gelatin with an embedded filled porcine kidney was made such that a gelatin layer of 2 or 4 cm thickness covered the organ. An impactor was dropped on this model from different heights and the resulting organ damage was categorized according to the abbreviated injury scale (AIS). The 50% energy threshold for damage and the 50% energy threshold causing injuries ≥ AIS 3 were determined for the two protecting soft layers to be 22 J and 32 J and 27 J and 36 J, respectively. A finite element model was created to determine the strain energy densities at the depth of the organ’s surface for these energies. The strain energy densities for the 50% damage thresholds were 88.9 mJ/cm3 and 86.7 mJ/cm3 for 2 and 4 cm and for the injuries ≥ AIS 3104.2 mJ/cm3 and 98.7 mJ/cm3. For forensic cases, this means that the thickness of the abdominal layers must be taken into account when the severity of an injury is used to draw conclusions about the applied impact strength.
- 9 July 2019
- Published by Springer Nature in International journal of legal medicine
- Vol. 134 (3) , 1007-1013
Influence of a soft tissue layer covering the kidney upon blunt impact
Blunt abdominal organ injury is an abundant and relevant topic in forensic medicine, yet comparatively few experimental studies have been performed to quantify organ injury threshold parameters. The goal of this study was to relate an impact to a kidney injury determining an energy threshold while taking account of the influence of the overlaying soft tissue thickness. A model consisting of ballistic gelatin with an embedded filled porcine kidney was made such that a gelatin layer of 2 or 4 cm thickness covered the organ. An impactor was dropped on this model from different heights and the resulting organ damage was categorized according to the abbreviated injury scale (AIS). The 50% energy threshold for damage and the 50% energy threshold causing injuries ≥ AIS 3 were determined for the two protecting soft layers to be 22 J and 32 J and 27 J and 36 J, respectively. A finite element model was created to determine the strain energy densities at the depth of the organ’s surface for these energies. The strain energy densities for the 50% damage thresholds were 88.9 mJ/cm3 and 86.7 mJ/cm3 for 2 and 4 cm and for the injuries ≥ AIS 3104.2 mJ/cm3 and 98.7 mJ/cm3. For forensic cases, this means that the thickness of the abdominal layers must be taken into account when the severity of an injury is used to draw conclusions about the applied impact strength.
- 1 February 2019
- Published by Elsevier in Forensic Science International
- Vol. 295, 137-144
How to recognise the traces left on a crime scene by a 3D-printed Liberator? Part 2. Elements of ammunition, marks on the weapons and polymer fragments
- 1 February 2019
- Published by Elsevier in Forensic Science International
- Vol. 295, 137-144
How to recognise the traces left on a crime scene by a 3D-printed Liberator? Part 2. Elements of ammunition, marks on the weapons and polymer fragments
- 4 December 2018
- Published by Springer Nature in International journal of legal medicine
- Vol. 133 (1) , 169-176
Rearward movement of the slide in semi-automatic pistols: a factor potentially influencing the configuration of muzzle imprint marks in contact shots
A muzzle imprint mark is a highly diagnostic finding, which indicates a contact shot. In many cases, it also provides additional information on the type of the weapon used and on the way in which it was held at the time of firing. In semi-automatic pistols, some constructional elements constituting the muzzle plane move to the rear together with the slide, which may prevent them from causing a corresponding imprint close to the bullet entrance hole. The present study comprises 30 consecutive autopsy cases of fatal contact shots to the head inflicted with semi-automatic pistols. The imprint marks accompanying the entrance wounds were compared with the muzzle ends of the respective weapons both before and after retracting the slide. It turned out that in a considerable number of cases (3 out of 30), the retractable parts were not depicted or only to a minor degree as components of the imprint mark. In order to validate the presumed correlation, experimental shots were fired to composite models using pistols in which the movable and the stationary parts forming the muzzle plane were dyed with different paints. Thus, it could be demonstrated that the muzzle imprint preferentially mirrors the front sides of the stationary parts such as the barrel end, the recoil guide, and the gun housing. Immediately after discharge, the slide and the ballooning skin of the bullet entrance site move in the same direction. The stationary parts of the weapon block the expansion of the skin bulging towards the muzzle, so that the skin gets firmly pressed against them. The dynamic interaction between the gun and the entrance region resulting in a characteristic imprint mark could be visualized by the use of a high-speed motion camera recording test shots to different composite models.
- 4 December 2018
- Published by Springer Nature in International journal of legal medicine
- Vol. 133 (1) , 169-176
Rearward movement of the slide in semi-automatic pistols: a factor potentially influencing the configuration of muzzle imprint marks in contact shots
A muzzle imprint mark is a highly diagnostic finding, which indicates a contact shot. In many cases, it also provides additional information on the type of the weapon used and on the way in which it was held at the time of firing. In semi-automatic pistols, some constructional elements constituting the muzzle plane move to the rear together with the slide, which may prevent them from causing a corresponding imprint close to the bullet entrance hole. The present study comprises 30 consecutive autopsy cases of fatal contact shots to the head inflicted with semi-automatic pistols. The imprint marks accompanying the entrance wounds were compared with the muzzle ends of the respective weapons both before and after retracting the slide. It turned out that in a considerable number of cases (3 out of 30), the retractable parts were not depicted or only to a minor degree as components of the imprint mark. In order to validate the presumed correlation, experimental shots were fired to composite models using pistols in which the movable and the stationary parts forming the muzzle plane were dyed with different paints. Thus, it could be demonstrated that the muzzle imprint preferentially mirrors the front sides of the stationary parts such as the barrel end, the recoil guide, and the gun housing. Immediately after discharge, the slide and the ballooning skin of the bullet entrance site move in the same direction. The stationary parts of the weapon block the expansion of the skin bulging towards the muzzle, so that the skin gets firmly pressed against them. The dynamic interaction between the gun and the entrance region resulting in a characteristic imprint mark could be visualized by the use of a high-speed motion camera recording test shots to different composite models.
- 1 January 2018
- Published by Elsevier in Meat Science
- Vol. 135, 159-165
Energy loss and impact of various stunning devices used for the slaughtering of water buffaloes
- 1 January 2018
- Published by Elsevier in Meat Science
- Vol. 135, 159-165
Energy loss and impact of various stunning devices used for the slaughtering of water buffaloes
- 1 January 2018
- Published by Elsevier in Meat Science
- Vol. 135, 74-78
Assessment of a specifically developed bullet casing gun for the stunning of water buffaloes
- 1 January 2018
- Published by Elsevier in Meat Science
- Vol. 135, 74-78
Assessment of a specifically developed bullet casing gun for the stunning of water buffaloes
- 15 October 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (1) , 173-177
Bullet fragmentation preceding a contour shot: case study and experimental simulation
In medico-legal literature, only a small number of publications deal with lethal injuries caused by shots with modified guns. This might lead to the conclusion that such cases are extremely rare. However, there are cases again and yet again. During the investigation process, the modified gun is of particular importance since it can show an unusual ballistic behaviour. The present paper reports on a suicide of a 60-year-old man, committed with a modified revolver and a lead bullet. The man had a single gunshot wound with entrance at the right temporal bone. Autopsy revealed that the bullet had fragmented into two major parts. The smaller one stood outside the cranial cavity and pushed its way alongside between the cranial bone and scalp to its end position in the left temporal area. The bigger part entered the cranial cavity and ended in the left parietal lobe. In shots on ballistic soap and on a head-model, the ballistics of the weapon and lead bullet were characterized. The angle necessary for bullet fragmentation was determined by shots on ballistic soap and turned out to be 55°–60° at a velocity of around 200 m/s. This knowledge was transferred to contact shots on a head-model consisting of a layered polyurethane sphere filled with 10 % ballistic gelatine and covered with a skin-like cap almost all around. The resulting injury pattern corresponded to the one of the suicide person. The bigger bullet part entered the skull while the smaller part pushed its way alongside between skin and skull causing an outer contour shot. Furthermore, the revolver was documented firing off two bullets by one trigger pull—a phenomenon of importance for forensic casework the authors have not found reported in forensic literature.
- 15 October 2016
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (1) , 173-177
Bullet fragmentation preceding a contour shot: case study and experimental simulation
In medico-legal literature, only a small number of publications deal with lethal injuries caused by shots with modified guns. This might lead to the conclusion that such cases are extremely rare. However, there are cases again and yet again. During the investigation process, the modified gun is of particular importance since it can show an unusual ballistic behaviour. The present paper reports on a suicide of a 60-year-old man, committed with a modified revolver and a lead bullet. The man had a single gunshot wound with entrance at the right temporal bone. Autopsy revealed that the bullet had fragmented into two major parts. The smaller one stood outside the cranial cavity and pushed its way alongside between the cranial bone and scalp to its end position in the left temporal area. The bigger part entered the cranial cavity and ended in the left parietal lobe. In shots on ballistic soap and on a head-model, the ballistics of the weapon and lead bullet were characterized. The angle necessary for bullet fragmentation was determined by shots on ballistic soap and turned out to be 55°–60° at a velocity of around 200 m/s. This knowledge was transferred to contact shots on a head-model consisting of a layered polyurethane sphere filled with 10 % ballistic gelatine and covered with a skin-like cap almost all around. The resulting injury pattern corresponded to the one of the suicide person. The bigger bullet part entered the skull while the smaller part pushed its way alongside between skin and skull causing an outer contour shot. Furthermore, the revolver was documented firing off two bullets by one trigger pull—a phenomenon of importance for forensic casework the authors have not found reported in forensic literature.
- 1 March 2016
- Published by Elsevier in Meat Science
- Vol. 113, 35-40
Magnetic resonance imaging and computer tomography of brain lesions in water buffaloes and cattle stunned with handguns or captive bolts
- 1 March 2016
- Published by Elsevier in Meat Science
- Vol. 113, 35-40
Magnetic resonance imaging and computer tomography of brain lesions in water buffaloes and cattle stunned with handguns or captive bolts
- 26 October 2015
- Published by Springer Nature in International journal of legal medicine
- Vol. 130 (3) , 751-757
A patterned abrasion caused by the impact of a cartridge case may simulate an atypical muzzle imprint mark
In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.
- 26 October 2015
- Published by Springer Nature in International journal of legal medicine
- Vol. 130 (3) , 751-757
A patterned abrasion caused by the impact of a cartridge case may simulate an atypical muzzle imprint mark
In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.
- 14 August 2014
- Published by Springer Nature in International journal of legal medicine
- Vol. 129 (1) , 125-131
Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of “unusual” and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide’s pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide’s body.
- 14 August 2014
- Published by Springer Nature in International journal of legal medicine
- Vol. 129 (1) , 125-131
Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of “unusual” and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide’s pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide’s body.
- 23 May 2013
- Published by Springer Nature in International journal of legal medicine
- Vol. 127 (5) , 931-936
The varying size of exit wounds from center-fire rifles as a consequence of the temporary cavity
To study the question whether and how the size and position of the temporary cavity influence the morphology and especially the size of a bullet exit wound, test shots were fired to composite models consisting of gelatine and pig soft tissue covered with skin (at the exit site). The dimensions of the composite model were determined such that the exit planes were located either at the level of the narrow channel or within the temporary cavity or behind it. The chronological sequence of wound formation and its relation to the current position of the bullet were documented by means of a high-speed camera. Test shots were fired from a distance of 10 m using 5.56 × 45 mm cartridges with full metal-jacketed pointed bullets (v 0 ∼ 912 m/s, E 0 ∼ 1,663 J). The study proved that the extension and position of the temporary wound cavity was decisive for the size of the exit wound: An exit plane within the cavity resulted in particularly large skin lesions, whereas the wound diameters were much smaller if the exit plane was located in front or behind the cavity. The exit hole reaches its maximum size only after the bullet has left the target synchronous to the staggered expansion of the temporary cavity.
- 23 May 2013
- Published by Springer Nature in International journal of legal medicine
- Vol. 127 (5) , 931-936
The varying size of exit wounds from center-fire rifles as a consequence of the temporary cavity
To study the question whether and how the size and position of the temporary cavity influence the morphology and especially the size of a bullet exit wound, test shots were fired to composite models consisting of gelatine and pig soft tissue covered with skin (at the exit site). The dimensions of the composite model were determined such that the exit planes were located either at the level of the narrow channel or within the temporary cavity or behind it. The chronological sequence of wound formation and its relation to the current position of the bullet were documented by means of a high-speed camera. Test shots were fired from a distance of 10 m using 5.56 × 45 mm cartridges with full metal-jacketed pointed bullets (v 0 ∼ 912 m/s, E 0 ∼ 1,663 J). The study proved that the extension and position of the temporary wound cavity was decisive for the size of the exit wound: An exit plane within the cavity resulted in particularly large skin lesions, whereas the wound diameters were much smaller if the exit plane was located in front or behind the cavity. The exit hole reaches its maximum size only after the bullet has left the target synchronous to the staggered expansion of the temporary cavity.