MMMarriner H. Merrill

Marriner H. Merrill

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marriner H. Merrill has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment of Adhesive Bond Strength for Long-Life Performance

    by Marriner Merrill

    One of the great challenges of adhesively bonded systems is to predict their long-term performance when exposed to environmental stressors. Ballistic glass delamination provides a relevant case study. Ballistic glass is typically a multi-layered composite with several layers of a hard material (glass) and an inner polymeric layer (polycarbonate). The adhesive between the glass

  • Open Access

    Investigation of an Ionic Liquid As a High-Temperature Electrolyte for Silicon-Lithium Systems

    by Christopher Rudolf, Corey Love, Marriner Merrill

    Electrolytes for lithium ion batteries which work over a wide range of temperatures are of interest in both research and applications. Unfortunately, most traditional electrolytes are unstable at high temperatures. As an alternative, solid state electrolytes are sometimes used. These are inherently safer because they have no flammable vapors, and solid state electrolytes can

  • Open Access

    Mechanisms of cell damage due to mechanical impact: an in vitro investigation

    by Wonmo Kang, Michael C. Robitaille, Marriner Merrill, Kirubel Teferra, Chunghwan Kim, Marc P. Raphael

    The dynamic response of cells when subjected to mechanical impact has become increasingly relevant for accurate assessment of potential blunt injuries and elucidating underlying injury mechanisms. When exposed to mechanical impact, a biological system such as the human skin, brain, or liver is rapidly accelerated, which could result in blunt injuries. For this reason, an acceleration of greater than > 150 g is the most commonly used criteria for head injury. To understand the main mechanism(s) of blunt injury under such extreme dynamic threats, we have developed an innovative experimental method that applies a well-characterized and -controlled mechanical impact to live cells cultured in a custom-built in vitro setup compatible with live cell microscopy. Our studies using fibroblast cells as a model indicate that input acceleration ( $${a}_{in}$$ain ) alone, even when it is much greater than the typical injury criteria, e.g., $${a}_{in}>1{,}000$$ain>1,000 g, does not result in cell damage. On the contrary, we have observed a material-dependent critical pressure value above which a sudden decrease in cell population and cell membrane damage have been observed. We have unambiguously shown that (1) this critical pressure is associated with the onset of cavitation bubbles in a cell culture chamber and (2) the dynamics of cavitation bubbles in the chamber induces localized compressive/tensile pressure cycles, with an amplitude that is considerably greater than the acceleration-induced pressure, to cells. More importantly, the rate of pressure change with time for cavitation-induced pressure is significantly faster (more than ten times) than acceleration-induced pressure. Our in vitro study on the dynamic response of biological systems due to mechanical impact is a crucial step towards understanding potential mechanism(s) of blunt injury and implementing novel therapeutic strategies post-trauma.


  • Open Access

    Multichannel fiber laser acoustic emission sensor system for crack detection and location in accelerated fatigue testing of aluminum panels

    by Caitlin R. S. Williams, Meredith N. Hutchinson, Joseph D. Hart, Marriner H. Merrill, Peter Finkel, William R. Pogue, Geoffrey A. Cranch

    Detection and location of the source of acoustic emission in a thin aluminum panel is demonstrated using a multichannel fiber laser sensor system. Acoustic emission generated by a crack in an aluminum panel used as a test coupon in an accelerated fatigue experiment is detected and the location of the crack identified. Acoustic emission is detected over a bandwidth of around 0.5 MHz from a serially multiplexed array of four laser sensors and compared with measurements taken from four piezo-electric sensors co-located with the fiber laser sensors. The location of the crack is determined by first estimating time difference of arrival of signals at each sensor using a novel algorithm based on the cumulative distribution transform method with hyperbolic positioning. The fiber laser sensor is shown to match the signal-to-noise ratio of the industry standard (Mistras S9225) piezo-electric acoustic emission sensor.


  • In Situ Visualization of Particle Motions during Wipe Sampling of Explosives and Other Trace Particulate Materials

    by Heather P. H. Liddell, Marriner H. Merrill

    Surface texture tailoring has the potential to increase the effectiveness of dry particle collection wipes, as a wipe’s topographical features control the intimate surface contact made with particles on the substrate (critical for van der Waals governed adhesion). However, texture-tailoring approaches have not yet been widely explored, in part because of a lack of understanding of the specific wipe topographies and wipe/particle interactions that maximize particle collection. Here we describe an in situ optical microscopy technique that enables direct observation of micrometer-scale particle-wipe interactions occurring at the wipe-substrate interface during contact sampling. The technique is demonstrated for nonwoven meta-aramid (Nomex®) collection wipes with particles ranging from 1 to 90 μm in diameter and substrates of different topographies (glass and a nylon coil zipper). Experiments with hemispherically coated Janus particles allow rolling motions to be distinguished from sliding motions, providing detailed information about how particles move prior to capture or release by the wipe. Particle-fiber and particle-particle interactions are seen to play important roles in particle capture, suggesting that conventional sphere-on-plane models are inadequate to describe adhesion behavior in these systems. Micrographs show how loose, flexible fibers in roughened textile wipes interrogate the valleys of uneven substrate topographies, allowing capture of particles that might otherwise be trapped within the substrate’s grooves and depressions. The materials used in this work are specifically relevant to explosives detection, but the in situ visualization technique is transferable for the study of any application involving dry particle collection, such as toxic substance sampling and dust removal.


  • Effect of re-use of surface sampling traps on surface structure and collection efficency for trace explosive residues

    by Lauryn E. DeGreeff, Heather P.H. Liddell, William R. Pogue, Marriner H. Merrill, Kevin J. Johnson


  • Electrowetting on polyimide and silicon substrates with high hysteresis

    by Marriner H. Merrill, Russell C. Reid, Natalie Gogotsi, James P. Thomas


  • In situ thermomechanical testing methods for micro/nano-scale materials

    by Wonmo Kang, Marriner Merrill, Jeffrey M. Wheeler

    The advance of micro/nanotechnology in energy-harvesting, micropower, electronic devices, and transducers for automobile and aerospace applications has led to the need for accurate thermomechanical characterization of micro/nano-scale materials to ensure their reliability and performance. This persistent need has driven various efforts to develop innovative experimental techniques that overcome the critical challenges associated with precise mechanical and thermal control of micro/nano-scale specimens during material characterization. Here we review recent progress in the development of thermomechanical testing methods from miniaturized versions of conventional macroscopic test systems to the current state of the art of in situ uniaxial testing capabilities in electron microscopes utilizing either indentation-based microcompression or integrated microsystems. We discuss the major advantages/disadvantages of these methods with respect to specimen size, range of temperature control, ease of experimentation and resolution of the measurements. We also identify key challenges in each method. Finally, we summarize some of the important discoveries that have been made using in situ thermomechanical testing and the exciting research opportunities still to come in micro/nano-scale materials.