Xiaoping Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaoping Chen has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Zuchao Zhu
5 shared publicationsYu Li
Zhejiang Key Laboratory of Multiflow and Fluid Machinery, Zhejiang Sci-Tech University, Hangzhou, China
3 shared publications- Zuchao Zhu
Key Laboratory of Fluid Transmission Technology of Zhejiang Province, Zhejiang Sci-Tech University 1 , Hangzhou 310018
3 shared publications - Chen-Shao Zhu2 shared publications
Hua-Shu Dou
National-Provincial Joint Engineering, Laboratory for Fluid Transmission System Technology, Zhejiang Sci-Tech University, Hangzhou, Zhejiang, China
2 shared publications- Jinglei Qu
School of Mechanical Engineering, Henan Institute of Technology, Xinxiang 453003, China
2 shared publications
Latest Publications
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (10)
Periodic transient pressure fluctuation in a high-speed centrifugal pump using variational mode decomposition combined with the Hilbert transform
Taking a high-speed centrifugal pump with a motor power of 280 kW and a rotational speed of 9685 r/min as the research object, large eddy simulations are conducted under transient and quasi-steady conditions. The flow rate of the former condition exhibits sinusoidal variation and oscillates between 0.25Qd and 0.75Qd (Qd represents the design flow rate). The low-frequency pressure fluctuation exhibits significant periodicity and is followed by a substantial number of high-frequency components. The dynamic features of the pressure fluctuation at the guide vane channel and near the volute tongue are examined using variational mode decomposition combined with the Hilbert transform. The number of intrinsic mode functions (IMFs) under transient condition is one greater than that under quasi-steady condition. The central frequency of the additional IMF is equal to the flow rate frequency, and the basic frequency remains at six times the rotational frequency. The amplitudes of the first three order modes are comparable, which is clearly observed at the guide vane channel inlet under transient conditions. The root mean square (RMS) value of the first intrinsic mode function (IMF1) component under transient condition is significantly greater than the corresponding value under quasi-steady condition near the volute tongue. Both the RMS value of the IMF1 component and the basic frequency amplitude generally decrease from upstream to downstream, and these trends have a small correlation with changes in the flow rate.
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (10)
Periodic transient pressure fluctuation in a high-speed centrifugal pump using variational mode decomposition combined with the Hilbert transform
Taking a high-speed centrifugal pump with a motor power of 280 kW and a rotational speed of 9685 r/min as the research object, large eddy simulations are conducted under transient and quasi-steady conditions. The flow rate of the former condition exhibits sinusoidal variation and oscillates between 0.25Qd and 0.75Qd (Qd represents the design flow rate). The low-frequency pressure fluctuation exhibits significant periodicity and is followed by a substantial number of high-frequency components. The dynamic features of the pressure fluctuation at the guide vane channel and near the volute tongue are examined using variational mode decomposition combined with the Hilbert transform. The number of intrinsic mode functions (IMFs) under transient condition is one greater than that under quasi-steady condition. The central frequency of the additional IMF is equal to the flow rate frequency, and the basic frequency remains at six times the rotational frequency. The amplitudes of the first three order modes are comparable, which is clearly observed at the guide vane channel inlet under transient conditions. The root mean square (RMS) value of the first intrinsic mode function (IMF1) component under transient condition is significantly greater than the corresponding value under quasi-steady condition near the volute tongue. Both the RMS value of the IMF1 component and the basic frequency amplitude generally decrease from upstream to downstream, and these trends have a small correlation with changes in the flow rate.
- Open Access
- 1 October 2025
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 18  (10) , 2627-2640
Multi-objective Optimization of the Bionic Blade in the Multi-blade Centrifugal Fan for Electric Vehicles Application Based on an Orthogonal Test
The multi-blade centrifugal fan, whose aeroacoustic properties significantly affect the noise, vibration and harshness performance of electric vehicles, is an important part of the automotive air conditioning system. A multi-blade centrifugal fan with a sawtooth trailing edge and a bionic blade is used. Multi-objective optimization of the bionic blade is investigated at the best efficiency point based on the orthogonal test to reduce sound pressure level (SPL) and ensure good aerodynamic performance. It is shown by the orthogonal test that the optimal combination of the three influencing factors is when the serration number, aspect ratio, and passivation ratio are 35, 1.5, and 0.2, respectively. The optimal model has 1.94% lower SPL than the original model, and the total pressure of both is basically unchanged. The presence of serration helps to mitigate vortex structures near the blade’s trailing edge. The dominant frequency is not influenced by the bionic blade and matches the frequency of blade passage. The maximum SPL is approximately 1,250 Hz for both models, with a maximum deviation of approximately 2.1 dB. The frequency bandwidth of the main noise source is between 1,250 and 1,600 Hz, showing a considerable difference between the two models.
- 1 October 2025
- Published by Academic World Research in Journal of Applied Fluid Mechanics
- Vol. 18  (10) , 2627-2640
Open AccessMulti-objective Optimization of the Bionic Blade in the Multi-blade Centrifugal Fan for Electric Vehicles Application Based on an Orthogonal Test
The multi-blade centrifugal fan, whose aeroacoustic properties significantly affect the noise, vibration and harshness performance of electric vehicles, is an important part of the automotive air conditioning system. A multi-blade centrifugal fan with a sawtooth trailing edge and a bionic blade is used. Multi-objective optimization of the bionic blade is investigated at the best efficiency point based on the orthogonal test to reduce sound pressure level (SPL) and ensure good aerodynamic performance. It is shown by the orthogonal test that the optimal combination of the three influencing factors is when the serration number, aspect ratio, and passivation ratio are 35, 1.5, and 0.2, respectively. The optimal model has 1.94% lower SPL than the original model, and the total pressure of both is basically unchanged. The presence of serration helps to mitigate vortex structures near the blade’s trailing edge. The dominant frequency is not influenced by the bionic blade and matches the frequency of blade passage. The maximum SPL is approximately 1,250 Hz for both models, with a maximum deviation of approximately 2.1 dB. The frequency bandwidth of the main noise source is between 1,250 and 1,600 Hz, showing a considerable difference between the two models.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (8)
Fast prediction of steady and unsteady hydrofoil cavitation flow fields based on the U-net enhanced Fourier neural operator
Cavitation, a complex phase-change phenomenon, is a primary cause of noise, vibration, and erosion in hydraulic machinery. This study employs a U-net enhanced Fourier neural operator (U-FNO) to predict cavitating flows around a National Advisory Committee for Aeronautics hydrofoil, encompassing steady sheet and unsteady cloud cavitation. L2 error results demonstrate that the U-FNO model achieves satisfactory overall prediction accuracy for both steady and unsteady flows with slightly higher error observed in the unsteady case. The predictive flow fields are highly similar to computational fluid dynamics (CFD) results. The prediction accuracy for cavitation occurrence in the steady case exceeds 0.9 with cavity shape and size closely matching CFD results. Although the cavity evolution of unsteady cloud cavitation is predicted relatively accurately, noticeable errors exist near the cavitation–liquid interfaces. Pronounced pressure deviations of the unsteady case are localized on the suction side and in wake regions, correlating with flow structures from bubble collapse. U-FNO shows lower L2 errors than U-net with mean errors on steady and unsteady test sets being 0.76 and 0.72 times those of U-net, respectively. Although U-net matches U-FNO in accuracy for steady lift/drag coefficients, the U-net shows noticeable errors at specific instants during unsteady predictions. Ablation experiments confirm superior learning capacity and data adaptability over U-net under different sample numbers.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (8)
Fast prediction of steady and unsteady hydrofoil cavitation flow fields based on the U-net enhanced Fourier neural operator
Cavitation, a complex phase-change phenomenon, is a primary cause of noise, vibration, and erosion in hydraulic machinery. This study employs a U-net enhanced Fourier neural operator (U-FNO) to predict cavitating flows around a National Advisory Committee for Aeronautics hydrofoil, encompassing steady sheet and unsteady cloud cavitation. L2 error results demonstrate that the U-FNO model achieves satisfactory overall prediction accuracy for both steady and unsteady flows with slightly higher error observed in the unsteady case. The predictive flow fields are highly similar to computational fluid dynamics (CFD) results. The prediction accuracy for cavitation occurrence in the steady case exceeds 0.9 with cavity shape and size closely matching CFD results. Although the cavity evolution of unsteady cloud cavitation is predicted relatively accurately, noticeable errors exist near the cavitation–liquid interfaces. Pronounced pressure deviations of the unsteady case are localized on the suction side and in wake regions, correlating with flow structures from bubble collapse. U-FNO shows lower L2 errors than U-net with mean errors on steady and unsteady test sets being 0.76 and 0.72 times those of U-net, respectively. Although U-net matches U-FNO in accuracy for steady lift/drag coefficients, the U-net shows noticeable errors at specific instants during unsteady predictions. Ablation experiments confirm superior learning capacity and data adaptability over U-net under different sample numbers.
- Open Access
Numerical Research on Pressure Fluctuation Characteristics of Small-Scale and High-Speed Automotive Pump
Rotor–stator interaction and the coupling between the clearance flow and main flow amplify the flow complexity in small-scale, high-speed automotive pumps. This degrades the pressure fluctuations, compromising the operational stability of these pumps. To better understand the pressure fluctuation distribution characteristics within such a pump, the Reynolds-averaged Navier–Stokes equations and the shear stress transport k-ω turbulence model were applied to numerically compute the pump. The simulation results were compared with experimental data, and good agreement was achieved. The results show that pressure fluctuations in the main flow region are mainly dominated by the blade passing frequency, and the intensity of pressure fluctuations in the near-field area of the tongue reaches its peak value, showing significant fluctuation characteristics. Significant peak signals are captured in the low-frequency band of pressure fluctuations in the clearance region. The pressure fluctuation characteristics are also affected by the rotor–stator interaction between the impeller front shroud and the volute casing, while the dominant frequency is still the blade passing frequency. In addition, the dominant frequencies of pressure fluctuations in the main and clearance flows show a similar distribution to the flow rate, but the minimum amplitude corresponds to different flow rates.
Open AccessNumerical Research on Pressure Fluctuation Characteristics of Small-Scale and High-Speed Automotive Pump
Rotor–stator interaction and the coupling between the clearance flow and main flow amplify the flow complexity in small-scale, high-speed automotive pumps. This degrades the pressure fluctuations, compromising the operational stability of these pumps. To better understand the pressure fluctuation distribution characteristics within such a pump, the Reynolds-averaged Navier–Stokes equations and the shear stress transport k-ω turbulence model were applied to numerically compute the pump. The simulation results were compared with experimental data, and good agreement was achieved. The results show that pressure fluctuations in the main flow region are mainly dominated by the blade passing frequency, and the intensity of pressure fluctuations in the near-field area of the tongue reaches its peak value, showing significant fluctuation characteristics. Significant peak signals are captured in the low-frequency band of pressure fluctuations in the clearance region. The pressure fluctuation characteristics are also affected by the rotor–stator interaction between the impeller front shroud and the volute casing, while the dominant frequency is still the blade passing frequency. In addition, the dominant frequencies of pressure fluctuations in the main and clearance flows show a similar distribution to the flow rate, but the minimum amplitude corresponds to different flow rates.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (3)
Rotational stall and pressure fluctuations in centrifugal pump impellers with transient flow rates
To investigate the characteristics of rotational stall and pressure fluctuations, this study presents two large eddy simulations for the five-blade and seven-blade centrifugal pump impellers under transient condition. The transient condition represents that the flow rate and rotational speed are sinusoidal and constant, respectively. Research shows that the processes of stall germination, stall transition and stall stabilization are clearly discerned in the evolution of rotational stall during both the dropping and rising stages. The increase in the number of blades enhances the uniformity of the time-averaged normal vorticity distributions among different passages and has negligible influence on the total time-averaged normal vorticity. The low-frequency pressure fluctuations range for the five-blade impeller is greater compared to that for the seven-blade impeller. The high-frequency components of the pressure fluctuations are intense primarily at the leading and trailing edges of the blade, especially when the instantaneous flow rate is below half load. The first-order dominant frequency is identical to the flow rate frequency in the impeller inlet and the impeller passages, and the increase in the number of blades results in a reduction in the dominant frequency amplitude.
- 1 March 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (3)
Rotational stall and pressure fluctuations in centrifugal pump impellers with transient flow rates
To investigate the characteristics of rotational stall and pressure fluctuations, this study presents two large eddy simulations for the five-blade and seven-blade centrifugal pump impellers under transient condition. The transient condition represents that the flow rate and rotational speed are sinusoidal and constant, respectively. Research shows that the processes of stall germination, stall transition and stall stabilization are clearly discerned in the evolution of rotational stall during both the dropping and rising stages. The increase in the number of blades enhances the uniformity of the time-averaged normal vorticity distributions among different passages and has negligible influence on the total time-averaged normal vorticity. The low-frequency pressure fluctuations range for the five-blade impeller is greater compared to that for the seven-blade impeller. The high-frequency components of the pressure fluctuations are intense primarily at the leading and trailing edges of the blade, especially when the instantaneous flow rate is below half load. The first-order dominant frequency is identical to the flow rate frequency in the impeller inlet and the impeller passages, and the increase in the number of blades results in a reduction in the dominant frequency amplitude.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (2)
Wall temperature effects on scaling law in high-temperature supersonic turbulent channel flows
Direct numerical simulations of temporally evolving high-temperature supersonic turbulent channel flows are performed at Mach number 3 and Reynolds number 4888. Air is assumed to behave as a five-species mixture and chemical equilibrium assumption. Five isothermal wall temperatures are in the range of 1733.2–4100.0 K. The results show that the mixture components undergo strong dissociation and recombination reactions along the channel for all wall temperature conditions. The wall temperature does not alter the original symmetry of fluctuating velocity and equilibrium species. The intermittence of turbulence is insensitive to the wall temperature, and the intermittence of equilibrium species enhances with the wall temperature increased. The scaling law derived and validated for calorically perfect gas still hold or can be generalized for chemical equilibrium assumption. Good linear relationship is observed in the extended self-similarity, which is more obvious than the velocity structure function. The influence of wall temperature on scaling law near the wall is more significant than that at the centerline. As the wall temperature increases, the relative scaling exponents of the generated components near the wall are gradually approaching to the theory proposed by She and Leveque.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37  (2)
Wall temperature effects on scaling law in high-temperature supersonic turbulent channel flows
Direct numerical simulations of temporally evolving high-temperature supersonic turbulent channel flows are performed at Mach number 3 and Reynolds number 4888. Air is assumed to behave as a five-species mixture and chemical equilibrium assumption. Five isothermal wall temperatures are in the range of 1733.2–4100.0 K. The results show that the mixture components undergo strong dissociation and recombination reactions along the channel for all wall temperature conditions. The wall temperature does not alter the original symmetry of fluctuating velocity and equilibrium species. The intermittence of turbulence is insensitive to the wall temperature, and the intermittence of equilibrium species enhances with the wall temperature increased. The scaling law derived and validated for calorically perfect gas still hold or can be generalized for chemical equilibrium assumption. Good linear relationship is observed in the extended self-similarity, which is more obvious than the velocity structure function. The influence of wall temperature on scaling law near the wall is more significant than that at the centerline. As the wall temperature increases, the relative scaling exponents of the generated components near the wall are gradually approaching to the theory proposed by She and Leveque.
- Open Access
A Novel Approach to Predicting Critical Alternating Stall in a Centrifugal Pump Impeller with Even Blades Under Transient Conditions
A novel approach is proposed to predict alternating stall in a centrifugal pump impeller with even blades by introducing a low-pressure ratio, which is defined as the ratio of the deviation of the low-pressure zones of adjacent impeller passages. The threshold of 2/3 is shown to be a good quantity with which to accurately and quantitatively predict alternating stall and even critical alternating stall (CAS). The effectiveness of this new approach is validated by comparison with previous findings obtained under quasi-steady conditions. Large eddy simulation data for a six-blade centrifugal pump impeller are used to predict the CAS under transient conditions, with the transient conditions corresponding to a sinusoidal flow rate with an equilibrium value of 0.5Qd (where Qd is the design load) and an initial phase of zero combined with different oscillation amplitudes. The low-pressure ratio frequency equals the flow rate frequency, approximately 2 Hz. The phase of the low-pressure ratio lags behind the flow rate. When the oscillation amplitude is larger than 0.15Qd, a non-stall state occurs during the dropping stage of the flow rate. The flow rates corresponding to the CAS during the dropping and rising stages, respectively, increase and decrease as the oscillation amplitude increases.
Open AccessA Novel Approach to Predicting Critical Alternating Stall in a Centrifugal Pump Impeller with Even Blades Under Transient Conditions
A novel approach is proposed to predict alternating stall in a centrifugal pump impeller with even blades by introducing a low-pressure ratio, which is defined as the ratio of the deviation of the low-pressure zones of adjacent impeller passages. The threshold of 2/3 is shown to be a good quantity with which to accurately and quantitatively predict alternating stall and even critical alternating stall (CAS). The effectiveness of this new approach is validated by comparison with previous findings obtained under quasi-steady conditions. Large eddy simulation data for a six-blade centrifugal pump impeller are used to predict the CAS under transient conditions, with the transient conditions corresponding to a sinusoidal flow rate with an equilibrium value of 0.5Qd (where Qd is the design load) and an initial phase of zero combined with different oscillation amplitudes. The low-pressure ratio frequency equals the flow rate frequency, approximately 2 Hz. The phase of the low-pressure ratio lags behind the flow rate. When the oscillation amplitude is larger than 0.15Qd, a non-stall state occurs during the dropping stage of the flow rate. The flow rates corresponding to the CAS during the dropping and rising stages, respectively, increase and decrease as the oscillation amplitude increases.
- 17 November 2024
- Published by Elsevier in Aerospace Science and Technology
- Vol. 155
Wall temperature effects in high-enthalpy supersonic turbulent channel flows considering air dissociation
- 17 November 2024
- Published by Elsevier in Aerospace Science and Technology
- Vol. 155
Wall temperature effects in high-enthalpy supersonic turbulent channel flows considering air dissociation