NGNan-Jie Gong

Nan-Jie Gong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nan-Jie Gong has a total of 134 co-authors. Here are the top co-authors by number of shared publications:

  • Boyang Pan

    Shanghai Key Laboratory of Magnetic Resonance, School of Physics, East China Normal University, Shanghai, China

    11 shared publications
  • Libo Xu

    Laboratory for Intelligent Medical Imaging, Tsinghua Cross-strait Research Institute, Xiamen, China

    6 shared publications
  • Chunlei Liu

    Department of Electrical Engineering and Computer Sciences University of California, Berkeley Berkeley California USA

    5 shared publications
  • Jun Zhao

    Department of Nuclear Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China

    5 shared publications
  • Hui Liu

    Department of Engineering Physics Tsinghua University Beijing People's Republic of China

    4 shared publications
  • Na Qi

    Department of Nuclear Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China

    4 shared publications

Latest Publications

  • Open Access

    Restoring image quality in accelerated PSMA PET across scanners and tracers using a generative adversarial network

    by Chao Cheng, Boyang Pan, Langdi Zhong, Libo Xu, Zhongqiu Guo, Qinqin Yang, Guixia Pan, Siyu Liang, Nan-Jie Gong, Changjing Zuo

  • Open Access

    A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

    by Aywin Wu, Jen-Chien Lai, Mo Kwan Ho, Justin Q.J. Ge, Nan-Jie Gong, Iris Y. Zhou, Monica Wong, Bradley J. Edelman, Russell W. Chan

    Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFR EIT estimates (2.92%; IQR, 0.46-12.53%) than for CAP EIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAP EIT estimates was just as strong at the kidney plane (R 2 = 0.98, p < 0.001) as it was at the conventional liver plane (R 2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAP EIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAP EIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

  • Open Access

    Deep learning-based enhancement of ultra-low-dose multi-tracer PET/MR: a technical feasibility study in Alzheimer’s disease

    by Na Qi, Boyang Pan, Zengbei Yuan, Xing Chen, Zirong Zhou, Xiaoxiao Chen, Libo Xu, Zhe Wang, Jie Ding, Nan-Jie Gong, et al.

    Background: To develop a Dual-Branch Dense Wavelet Attention Network (DDWAN) for enhancing simulated ultra-low-dose multi-tracer (Aβ, tau and FDG) PET imaging acquired on a PET/MR system and to evaluate its technical feasibility in Alzheimer’s disease (AD), using full-dose images acquired under the same protocol as references. Methods: This retrospective study included patients underwent 18 F-florbetapir (Aβ), 18 F-APN-1607 (tau), or 18 F-FDG (N) PET/MR. DDWAN was trained to generate high-quality images from simulated ultra-low-dose PET data (1/100–1/5 of standard dose) with co-registered T1WI as anatomical guidance. Image quality was quantified quantitatively via Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index Measure (SSIM). Quantitative agreement was evaluated by comparing Standardized Uptake Value Ratios (SUVR) and Centiloid values between DDWAN-enhanced low-dose and standard-dose images. Qualitative assessment was performed by nuclear medicine physicians using a 5-point Likert scale. Diagnostic performance was evaluated using standard-dose visual interpretation as the reference standard. Results: The DDWAN model significantly enhanced image quality across all tracers and dose levels. Quantitative metrics demonstrated substantial improvements, with PSNR increasing most notably at the 1/100 dose (ΔPSNR: +7.11 dB for Aβ, + 11.75 dB for tau, + 4.82 dB for FDG; all Bonferroni-corrected P < 0.0125). Excellent quantitative agreement was observed, with minimal bias in SUVR and Centiloid values between enhanced low-dose and standard-dose images (all P >0.05). Qualitative scores for DDWAN-enhanced images were significantly superior to original low-dose images and comparable to standard-dose references, with the majority of 1/20 dose images rated as diagnostically acceptable (score ≥ 3). Diagnostic agreement remained high across all tracers, with sensitivity and specificity exceeding 90% even at the 1/100 dose level for 18 F-APN-1607 and 18 F-FDG. Conclusion: DDWAN improved image quality and quantitative consistency of simulated ultra-low-dose multi-tracer (Aβ, tau and FDG) PET/MR images compared with full-dose references acquired under the same protocol. These results support technical feasibility, while further validation using standard tracer-specific acquisition windows is required before clinical application.

  • Enhancing compressed sensing and parallel imaging accelerated magnetic resonance angiography using a dual‐domain projection generative adversarial network

    by Libo Xu, Yueyan Bian, Kexin Gan, Boyang Pan, Kristen W Yeom, Michael Moseley, Qi Yang, Nan‐Jie Gong

    Background: As a key modality for cerebrovascular disease diagnosis, time‐of‐flight magnetic resonance angiography (TOF‐MRA) necessitates high spatial resolution and sensitivity. Although acceleration of MRA is critical for reducing scan time and increasing patient throughput, achieving diagnostic‐quality images at high undersampling rates remains a significant challenge. Purpose: This study aims to develop a deep learning‐based post‐processing method that generates high‐quality MRA images from highly undersampled data, improving detection sensitivity for vascular abnormalities. Methods: This prospective study employed a standard MRA scan as a baseline, followed by accelerated scans using compressed sensing (CS) with factors of 4, 6, 8, and 10, as well as sensitivity encoding (SENSE) with a factor of 4. A Dual‐Domain Projection Generative Adversarial Network (DDPGAN) was proposed, taking stacked 2D patches from accelerated MRA reconstructions as input and employing a dual‐headed discriminator to enhance image quality. The quantitative indicators included Peak Signal‐to‐Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM), Normalized Mean Squared Error (NMSE), and Signal‐to‐Noise Ratio (SNR). Qualitative assessment was conducted using a 5‐point reader scale focusing on image clarity and diagnostic confidence. Results: Sixty‐four patients (53 ± 16 years; 26 men) were included. DDPGAN outperformed other deep learning models across all qualitative and quantitative metrics, achieving PSNR = 31.98 dB, SSIM = 0.88, NMSE = 0.052, and SNR = 56.82 for CS×10. Qualitatively, CS×4 images improved from poor (reader1: 3.50 ± 0.50; reader2: 3.64 ± 0.48) to good/excellent (reader1: 4.64 ± 0.48; reader2: 4.93 ± 0.26), surpassing even standard scans (reader 1: 3.93 ± 0.707, reader 2: 4.71 ± 0.808). Comparative studies confirmed the robustness of DDPGAN across diverse acceleration scenarios, with significant improvements in the visualization of major cerebral vascular structures. Conclusion: The DDPGAN framework significantly enhances accelerated MRA image quality, enabling high detail preservation and diagnostic confidence across various acceleration scenarios. Its dual‐domain design supports efficient, high‐quality MRA examinations, indicating strong clinical potential particularly in the evaluation of cerebrovascular disease.

  • Open Access

    Few shots transfer learning for universal SPECT denoising across diverse acquisition protocols

    by Boyang Pan, Jianchen Pan, Kexin Gan, Yuting Shen, Xiaoxiao Chen, Langdi Zhong, Hang Yang, Jie Chen, Laiping Xie, Wei Guo, et al.

    Objective. Accelerated single photon emission computed tomography (SPECT) imaging, achieved by reducing either the number of projection angles or the acquisition time per angle, enhances clinical workflow efficiency but introduces elevated noise. This study aims to develop and validate a universal DL-based reconstruction framework that effectively generalizes across diverse, clinically-realistic SPECT acceleration protocols by overcoming the data scarcity challenge. Approach. SPECT bone scans from 103 patients were acquired under a standard scan (60 views, 12 s/view, 60v12s) followed by a fast scan using one of five acceleration protocols (60v6s, 60v3s, 30v12s, 30v6s, 16v12s). A U -Net-based reconstruction framework was implemented using three strategies: (1) single model, trained on individual acceleration protocol), (2) base model, trained on aggregated datasets from five acceleration protocols, and (3) transfer model, fine-tuned from the base model for protocol-specific optimization. Pixel-level accuracy and structural similarity were assessed using peak signal-to-noise ratio (PSNR), structural similarity index (SSIM) metrics, and maximum pixel value of lesions. Clinical evaluation of image quality, radionuclide detail, artifacts, and diagnostic confidence was conducted using a 5-point system. Main results. Quantitative evaluation showed the transfer model achieved better PSNR and SSIM across all protocols (highest 48.02 PSNR and 0.9918 SSIM in 30v6 s protocol). Qualitative analysis confirmed enhanced structural fidelity. Clinical evaluations rated the transfer model highest across metrics, with scores of 4.667 ± 0.508 (image quality, 30v12 s), 4.800 ± 0.250 (radionuclide detail, 60v6 s), 1.150 ± 0.173 (artifact reduction, 60v6 s), and 4.800 ± 0.250 (diagnostic confidence, 60v6 s), surpassing full-scan results in most cases. Significance . The proposed transfer learning (TL) framework effectively addressed data scarcity and improved reconstruction performance across diverse SPECT acceleration scenarios. The adoption of a TL strategy mitigates data scarcity by utilizing shared features and fine-tuning for specific protocols. The framework demonstrates potential for integration into fast SPECT workflows, facilitating reliable use across diverse imaging scenarios.

  • Open Access

    Deep learning‑based ultra-high-resolution CT imaging of viral pneumonia at admission and after discharge

    by Yanli Gao, Boyang Pan, Lin Niu, Libo Xu, Ziheng Guo, Weican Liu, Penghui Sun, Yanyan Zhang, Xiaoli Xu, Nan-Jie Gong, et al.

    Advancement in deep learning has introduced significant potential for enhancing CT image quality without increasing patient radiation exposure. In this stu

  • Clinical validation of a deep learning model for low-count PET image enhancement

    by Qigang Long, Yan Tian, Boyang Pan, Zhenchun Xu, Wenqian Zhang, Libo Xu, Wenhuan Fan, Taotao Pan, Nan-Jie Gong

    Purpose To investigate the effects of the deep learning model RaDynPET on fourfold reduced-count whole-body PET examinations. Methods A total of 120 patients (84 internal cohorts and 36 external cohorts) undergoing 18F-FDG PET/CT examinations were enrolled. PET images were reconstructed using OSEM algorithm with 120-s (G120) and 30-s (G30) list-mode data. RaDynPET was developed to generate enhanced images (R30) from G30. Two experienced nuclear medicine physicians independently evaluated subjective image quality using a 5-point Likert scale. Standardized uptake values (SUV), standard deviations, liver signal-to-noise ratio (SNR), lesion tumor-to-background ratio (TBR), and contrast-to-noise ratio (CNR) were compared. Subgroup analyses evaluated performance across demographics, and lesion detectability were evaluated using external datasets. RaDynPET was also compared to other deep learning methods. Results In internal cohorts, R30 demonstrated significantly higher image quality scores than G30 and G120. R30 showed excellent agreement with G120 for liver and lesion SUV values and surpassed G120 in liver SNR and CNR. Liver SNR and CNR of R30 were comparable to G120 in thin group, and the CNR of R30 was comparable to G120 in young age group. In external cohorts, R30 maintained strong SUV agreement with G120, with lesion-level sensitivity and specificity of 95.45% and 98.41%, respectively. There was no statistical difference in lesion detection between R30 and G120. RaDynPET achieved the highest PSNR and SSIM among deep learning methods. Conclusion The RaDynPET model effectively restored high image quality while maintaining SUV agreement for 18F-FDG PET scans acquired in 25% of the standard acquisition time.


  • Deep learning-based image domain reconstruction enhances image quality and pulmonary nodule detection in ultralow-dose CT with adaptive statistical iterative reconstruction-V

    by Kai Ye, Libo Xu, Boyang Pan, Jie Li, Meijiao Li, Huishu Yuan, Nan-Jie Gong

    Objectives To evaluate the image quality and lung nodule detectability of ultralow-dose CT (ULDCT) with adaptive statistical iterative reconstruction-V (ASiR-V) post-processed using a deep learning image reconstruction (DLIR)-based image domain compared to low-dose CT (LDCT) and ULDCT without DLIR. Materials and methods A total of 210 patients undergoing lung cancer screening underwent LDCT (mean ± SD, 0.81 ± 0.28 mSv) and ULDCT (0.17 ± 0.03 mSv) scans. ULDCT images were reconstructed with ASiR-V (ULDCT-ASiR-V) and post-processed using DLIR (ULDCT-DLIR). The quality of the three CT images was analyzed. Three radiologists detected and measured pulmonary nodules on all CT images, with LDCT results serving as references. Nodule conspicuity was assessed using a five-point Likert scale, followed by further statistical analyses. Results A total of 463 nodules were detected using LDCT. The image noise of ULDCT-DLIR decreased by 60% compared to that of ULDCT-ASiR-V and was lower than that of LDCT (p < 0.001). The subjective image quality scores for ULDCT-DLIR (4.4 [4.1, 4.6]) were also higher than those for ULDCT-ASiR-V (3.6 [3.1, 3.9]) (p < 0.001). The overall nodule detection rates for ULDCT-ASiR-V and ULDCT-DLIR were 82.1% (380/463) and 87.0% (403/463), respectively (p < 0.001). The percentage difference between diameters > 1 mm was 2.9% (ULDCT-ASiR-V vs. LDCT) and 0.5% (ULDCT-DLIR vs. LDCT) (p = 0.009). Scores of nodule imaging sharpness on ULDCT-DLIR (4.0 ± 0.68) were significantly higher than those on ULDCT-ASiR-V (3.2 ± 0.50) (p < 0.001). Conclusion DLIR-based image domain improves image quality, nodule detection rate, nodule imaging sharpness, and nodule measurement accuracy of ASiR-V on ULDCT. Key Points Question Deep learning post-processing is simple and cheap compared with raw data processing, but its performance is not clear on ultralow-dose CT. Findings Deep learning post-processing enhanced image quality and improved the nodule detection rate and accuracy of nodule measurement of ultralow-dose CT. Clinical relevance Deep learning post-processing improves the practicability of ultralow-dose CT and makes it possible for patients with less radiation exposure during lung cancer screening.


  • Open Access

    Clinical performance of deep learning-enhanced ultrafast whole-body scintigraphy in patients with suspected malignancy

    by Na Qi, Boyang Pan, Qingyuan Meng, Yihong Yang, Jie Ding, Zengbei Yuan, Nan-Jie Gong, Jun Zhao

    To evaluate the clinical performance of two deep learning methods, one utilizing real clinical pairs and the other utilizing simulated datasets, in enhancing image quality for two-dimensional (2D) fast whole-body scintigraphy (WBS). A total of 83 patients with suspected bone metastasis were retrospectively enrolled. All patients underwent single-photon emission computed tomography (SPECT) WBS at speeds of 20 cm/min (1x), 40 cm/min (2x), and 60 cm/min (3x). Two deep learning models were developed to generate high-quality images from real and simulated fast scans, designated 2x-real and 3x-real (images from real fast data) and 2x-simu and 3x-simu (images from simulated fast data), respectively. A 5-point Likert scale was used to evaluate the image quality of each acquisition. Accuracy, sensitivity, specificity, and the area under the curve (AUC) were used to evaluate diagnostic efficacy. Learned perceptual image patch similarity (LPIPS) and the Fréchet inception distance (FID) were used to assess image quality. Additionally, the count-level consistency of WBS was compared between the two models. Subjective assessments revealed that the 1x images had the highest general image quality (Likert score: 4.40 ± 0.45). The 2x-real, 2x-simu and 3x-real, 3x-simu images demonstrated significantly better quality than the 2x and 3x images (Likert scores: 3.46 ± 0.47, 3.79 ± 0.55 vs. 2.92 ± 0.41, P < 0.0001; 2.69 ± 0.40, 2.61 ± 0.41 vs. 1.36 ± 0.51, P < 0.0001), respectively. Notably, the quality of the 2x-real images was inferior to that of the 2x-simu images (Likert scores: 3.46 ± 0.47 vs. 3.79 ± 0.55, P = 0.001). The diagnostic efficacy for the 2x-real and 2x-simu images was indistinguishable from that of the 1x images (accuracy: 81.2%, 80.7% vs. 84.3%; sensitivity: 77.27%, 77.27% vs. 87.18%; specificity: 87.18%, 84.63% vs. 87.18%. All P > 0.05), whereas the diagnostic efficacy for the 3x-real and 3x-simu was better than that for the 3x images (accuracy: 65.1%, 66.35% vs. 59.0%; sensitivity: 63.64%, 63.64% vs. 64.71%; specificity: 66.67%, 69.23% vs. 55.1%. All P < 0.05). Objectively, both the real and simulated models achieved significantly enhanced image quality from the accelerated scans in the 2x and 3x groups (FID: 0.15 ± 0.18, 0.18 ± 0.18 vs. 0.47 ± 0.34; 0.19 ± 0.23, 0.20 ± 0.22 vs. 0.98 ± 0.59. LPIPS: 0.17 ± 0.05, 0.16 ± 0.04 vs. 0.19 ± 0.05; 0.18 ± 0.05, 0.19 ± 0.05 vs. 0.23 ± 0.04. All P < 0.05). The count-level consistency with the 1x images was excellent for all four sets of model-generated images (P < 0.0001). Ultrafast 2x speed (real and simulated) images achieved comparable diagnostic value to that of standardly acquired images, but the simulation algorithm does not necessarily reflect real data.