WJWon Hyuk Jang

Won Hyuk Jang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Won Hyuk Jang has a total of 76 co-authors. Here are the top co-authors by number of shared publications:

  • Ki Hean Kim

    Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Republic of Korea

    13 shared publications
  • Yeoreum Yoon

    Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784, South Korea

    10 shared publications
  • Bumju Kim

    Divison of Integrative Biosciences & Biotechnology, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-gu, Pohang, Gyeongbuk 37673, South Korea

    5 shared publications
  • Seunghun Lee

    Department of Mechanical Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Republic of Korea

    5 shared publications
  • Soonjae Kwon

    Department of Mechanical Engineering, Pohang University of Science and Technology, San 31, Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784, South Korea

    5 shared publications
  • Taejun Wang

    Division of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, 37673, Republic of Korea

    5 shared publications

Latest Publications

  • Open Access

    Defect height estimation via model-less TSOM under optical resolution

    by Ji Yong Joo, Jun Ho Lee, Won Hyuk Jang, Yong Woon Lim

    We propose a new method of through-focus scanning optical microscopy (TSOM) without a reference database, i.e., a model-less TSOM method. Building a TSOM reference database is time-consuming or even impractical in some TSOM applications that involve complex structures, such as 3D NAND, or irregular shapes such as defects. The proposed model-less TSOM method was used to determine just the height of defect particles, for the first time as far as we are aware. Defect height is the only relevant dimension for the display panel application. Specifically, we analyzed 40 organic light-emitting diode (OLED) surface defects using a lab-developed motion-free TSOM tool consisting of a 50× objective lens (numerical aperture (NA) 0.55), a 532-nm light source, an imaging detector with a 7.5-µm pitch, and a deformable mirror. The tool is in-line and capable of achieving high throughput non-destructively, both relevant features for industrial applications. We investigated linear regression relations between newly defined TSOM parameters (TSOM height, TSOM area and TSOM volume) and the defect heights, which were first measured by atomic force microscopy (AFM). Following defect classification based on in-focus images, we successfully found that the AFM height has a linear correlation with 50% TSOM height (H50%) within ± 20.3 nm (1σ) error over the range of 140 to 950 nm. The one-sigma error, i.e., 20.3 nm, was approximately λ/26 or 1/43 of the depth of focus (DOF) of the applied microscope.


  • 66‐5: Late‐News‐Paper: Fast Response Texture Free Polymer Stabilized Vertically Aligned Liquid Crystal Displays

    by Yong-Woon Lim, Won Hyuk Jang, Cheolsu Jeong, Hyeon Hwan Kim

    We propose a polymer stabilized vertical aligned (PSVA) liquid crystal (LC) mode with 12‐domains having a center gap (CG) of 6 μm. In the conventional PSVA LC mode, the pixel is divided either into high or low sub‐pixel and the respective sub‐pixel has 4 domains for wider viewing and high quality visibility. However, difficulty in texture control and slow response time in the low sub‐pixel with the long axis remains. In addition to eliminating the major cause of texture irregularity, the proposed 12‐domains PSVA LC mode is divided into 4‐domains and 8‐domains in the high and the low sub‐pixels having CG, respectively. In the proposed 12‐domains PSVA LC mode, the LC director is well defined the multi‐directional tilted direction through the azimuthal angles in the domains and the brightness and viewing angle are similar to the conventional PSVA LC mode. In particular, the rising response time is faster while the falling response time is similar to the conventional PSVA LC mode due to additional center bar inside of pixels. Moreover, high quality visibility is achieved.


  • Characterization of early-stage cutaneous radiation injury by using optical coherence tomography angiography

    by Jungbin Lee, Won Hyuk Jang, Sehwan Shim, Bumju Kim, Jae Kyung Myung, Sunhoo Park, Ki Hean Kim

    Cutaneous radiation injury (CRI) is a skin injury caused by exposure to high dose ionizing radiation (IR). Diagnosis and treatment of CRI is difficult due to its initial clinically latent period and the following inflammatory bursts. Early detection of CRI before clinical symptoms will be helpful for effective treatment, and various optical methods have been applied with limitations. Here we show that optical coherence tomography angiography (OCTA) could detect changes in the skin during the latent period in CRI mouse models non-invasively. CRI was induced on the mouse hindlimb with exposure to various IR doses and the injured skin regions were imaged longitudinally by OCTA until the onset of clinical symptoms. OCTA detected several changes in the skin including the skin thickening, the dilation of large blood vessels, and the irregularity in vessel boundaries. Some of OCTA findings were confirmed by histology. The study results showed that OCTA could be used for early CRI detection.


  • Moxifloxacin Labeling‐Based Multiphoton Microscopy of Skin Cancers in Asians

    by Hoonchul Chang, Won Hyuk Jang, Seunghun Lee, Bumju Kim, Myoung Joon Kim, Won Oh Kim, Young Wook Ryoo, Byung Ho Oh, Ki Hean Kim

    Background and Objectives: Although multiphoton microscopy (MPM) can visualize both cell and extracellular matrix (ECM) structures of the skin in high‐contrast without exogenous labeling, label‐free MPM is usually too slow to image clinically relevant large regions. A high‐speed MPM method would be beneficial for evaluating clinical skin specimens by increasing the imaging area. In this study, moxifloxacin labeling‐based MPM (moxifloxacin MPM) was characterized in various human skin cancer specimens.Study Design/Materials and Methods: Moxifloxacin ophthalmic solution was used for cell‐labeling and MPM imaging was conducted afterwards. Moxifloxacin MPM was characterized in ex vivo normal human skin and skin cancer specimens in comparison with the label‐free MPM and fluorescence confocal microscopy (FCM) using acridine orange as a labeling agent. Then, moxifloxacin MPM was applied to various ex vivo human skin cancer specimens including basal cell carcinoma (BCC), squamous cell carcinoma (SCC), dermatofibrosarcoma protuberans (DFSP). Results of moxifloxacin MPM were compared with bright‐field clinical and histopathologic findings.Results: Moxifloxacin MPM imaged both cells and collagen in the skin, similarly to label‐free MPM, but with enhanced fluorescence intensities in cells and enhanced imaging speeds. Moxifloxacin MPM imaged cells in the skin similarly to acridine orange‐based FCM. Moxifloxacin MPM of various human skin cancer specimens imaged their specific cellular features. The microscopic features detected in moxifloxacin MPM were confirmed with histological images.Conclusions: This observational pilot study demonstrated that moxifloxacin MPM could detect specific cellular features of various skin cancers in good correlation with histopathological images in Asian patients at the higher imaging speed than label‐free MPM. Lasers Surg. Med.


  • Open Access

    Two-photon microscopy of Paneth cells in the small intestine of live mice

    by Won Hyuk Jang, Areum Park, Taejun Wang, Chan Johng Kim, Hoonchul Chang, Bo-Gie Yang, Myoung Joon Kim, Seung-Jae Myung, Sin-Hyeog Im, Myoung Ho Jang, et al.

    Paneth cells are one of the principal epithelial cell types in the small intestine, located at the base of intestinal crypts. Paneth cells play key roles in intestinal host-microbe homeostasis via granule secretion, and their dysfunction is implicated in pathogenesis of several diseases including Crohn’s disease. Despite their physiological importance, study of Paneth cells has been hampered by the limited accessibility and lack of labeling methods. In this study, we developed a simple in vivo imaging method of Paneth cells in the intact mouse small intestine by using moxifloxacin and two-photon microscopy (TPM). Moxifloxacin, an FDA-approved antibiotic, was used for labeling cells and its fluorescence was strongly observed in Paneth cell granules by TPM. Moxifloxacin labeling of Paneth cell granules was confirmed by molecular counterstaining. Comparison of Paneth cells in wild type, genetically obese (ob/ob), and germ-free (GF) mice showed different granule distribution. Furthermore, Paneth cell degranulation was observed in vivo. Our study suggests that TPM with moxifloxacin labeling can serve as a useful tool for studying Paneth cell biology and related diseases.


  • Visualization of laser tattoo removal treatment effects in a mouse model by two-photon microscopy: publisher’s note

    by Won Hyuk Jang, Yeoreum Yoon, Wonjoong Kim, Soonjae Kwon, Seunghun Lee, Duke Song, Jong Woon Choi, Ki Hean Kim

    This publisher’s note amends an author affiliation in [Biomed. Opt. Express 8(8), 3735 (2017)].


  • Comparison between reflectance confocal microscopy and 2‐photon microscopy in early detection of cutaneous radiation injury in a mouse model in vivo

    by Won Hyuk Jang, Soonjae Kwon, Sehwan Shim, Jae Kyung Myung, Sejung Yang, Sunhoo Park, Ki Hean Kim

    Cutaneous radiation injury (CRI) is a skin injury caused by high dose exposure of ionizing radiation (IR). For proper treatment, early detection of CRI before clinical symptoms is important. Optical microscopic techniques such as reflectance confocal microscopy (RCM) and two‐photon microscopy (TPM) have been tested as the early diagnosis method by detecting cellular changes. In this study, RCM and TPM were compared in the detection of cellular changes caused by CRI in an in‐vivo mouse model. CRI was induced on the mouse hindlimb skin with various IR doses and the injured skin regions were imaged longitudinally by both modalities until the onset of clinical symptoms. Both RCM and TPM detected the changes of epidermal cells and sebaceous glands before clinical symptoms in different optical contrasts. RCM detected changes of cell morphology and scattering property based on light reflection. TPM detected detail changes of cellular structures based on autofluorescence of cells. Since both RCM and TPM were sensitive to the early‐stage CRI by using different contrasts, the optimal method for clinical CRI diagnosis could be either individual methods or their combination. This article is protected by copyright. All rights reserved


  • Open Access

    Three-photon tissue imaging using moxifloxacin

    by Seunghun Lee, Jun Ho Lee, Taejun Wang, Won Hyuk Jang, Yeoreum Yoon, Bumju Kim, Yong Woong Jun, Myoung Joon Kim, Ki Hean Kim

    Moxifloxacin is an antibiotic used in clinics and has recently been used as a clinically compatible cell-labeling agent for two-photon (2P) imaging. Although 2P imaging with moxifloxacin labeling visualized cells inside tissues using enhanced fluorescence, the imaging depth was quite limited because of the relatively short excitation wavelength (1000 nm excitation wavelength. After obtaining the excitation and emission spectra of moxifloxacin, moxifloxacin-based 3P imaging was applied to ex vivo mouse bladder and ex vivo mouse small intestine tissues and compared with moxifloxacin-based 2P imaging by switching the excitation wavelength of a Ti:sapphire oscillator between near 1030 and 780 nm. Both moxifloxacin-based 2P and 3P imaging visualized cellular structures in the tissues via moxifloxacin labeling, but the image contrast was better with 3P imaging than with 2P imaging at the same imaging depths. The imaging speed and imaging depth of moxifloxacin-based 3P imaging using a Ti:sapphire oscillator were limited by insufficient excitation power. Therefore, we constructed a new system for moxifloxacin-based 3P imaging using a high-energy Yb fiber laser at 1030 nm and used it for in vivo deep tissue imaging of a mouse small intestine. Moxifloxacin-based 3P imaging could be useful for clinical applications with enhanced imaging depth.


  • Visualization of laser tattoo removal treatment effects in a mouse model by two-photon microscopy: erratum

    by Won Hyuk Jang, Yeoreum Yoon, Wonjoong Kim, Soonjae Kwon, Seunghun Lee, Duke Song, Jong Woon Choi, Ki Hean Kim

    We present an erratum to correct an error in our paper “Visualization of laser tattoo removal treatment effects in a mouse model by two-photon microscopy” [Biomed. Opt. Express 8, 3735 (2017)].


  • Mono‐allyloxylated Cucurbit[7]uril Acts as an Unconventional Amphiphile To Form Light‐Responsive Vesicles

    by Kyeng Min Park, Kangkyun Baek, Young Ho Ko, Annadka Shrinidhi, James Murray, Won Hyuk Jang, Ki Hean Kim, Jun‐Seok Lee, Jejoong Yoo, Sungwan Kim, et al.

    Serendipitously, mono‐allyloxylated cucurbit[7]uril (AO1CB[7]) was discovered to act as an unconventional amphiphile which self‐assembles into light‐responsive vesicles (AO1CB[7]VC) in water. Although the mono‐allyloxy group, directly tethered on the periphery of CB[7], is much shorter (C4) than the hydrophobic tails of conventional amphiphiles, it played an important role in vesicle formation. Light‐activated transformation of the allyloxy group by conjugation with glutathione was exploited as a remote tool to disrupt the vesicle. The vesicle showed on‐demand release of cargo upon irradiation by a laser, after they were internalized into cancer cells. This result demonstrated the potential of AO1CB[7]VC as a new type of light‐responsive intracellular delivery vehicle for the release of therapeutic cargo, within cells, on demand.