Dominique Chapelle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dominique Chapelle has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Philippe Moireau
LMS -CNRS -Ecole Polytechnique Inria Institut Polytechnique de Paris Palaiseau France
12 shared publications - Marina Vidrascu
Sorbonne Université, CNRS, LJLL - Inria, Paris, France
5 shared publications - Miguel Angel Fernández
Sorbonne Universite & CNRS, UMR 7598 LJLL, Paris, France
5 shared publications - François Kimmig
Inria, Inria Saclay
3 shared publications - Jacques Sainte-Marie
Inria Paris 2 rue Simone Iff CS 42112 75589 Cedex 12 Paris France
3 shared publications P. Moireau
Université Paris-Saclay
3 shared publications
Latest Publications
- 30 September 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (5) , 116
A 3D-shell model of left atrial electromechanics
- 30 September 2026
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 25 (5) , 116
A 3D-shell model of left atrial electromechanics
- 18 February 2026
- Published by Elsevier in Journal of Computational Physics
- Vol. 556
A fictitious domain method with enhanced interfacial mass conservation for immersed FSI with thin-walled solids
- 18 February 2026
- Published by Elsevier in Journal of Computational Physics
- Vol. 556
A fictitious domain method with enhanced interfacial mass conservation for immersed FSI with thin-walled solids
- 29 May 2025
- Published by Springer Nature
- p. 48-59
3D-Shell Electromechanical Modeling of the Left Atrium
- 29 May 2025
- Published by Springer Nature
- p. 48-59
3D-Shell Electromechanical Modeling of the Left Atrium
- Open Access
3D-Shell Electromechanical Modeling of the Left Atrium
The thin-walled nature of the atrial wall can lead to numerical locking issues when using 3D models discretized with standard finite elements. In order to circumvent these issues, we introduce a comprehensive electromechanical model of the left atrium based on a 3D-shell formulation. The model integrates both the passive and active components of the atrial tissue, while blood flow and the mitral valve dynamics are described in a lumped parameter fashion. The resulting model is discretized with a finite element approach specifically designed to mitigate numerical locking. The effectiveness of the proposed approach is evaluated by comparing the numerical results with biomarkers reported in the literature, in the case of both healthy and pathological conditions.
Open Access3D-Shell Electromechanical Modeling of the Left Atrium
The thin-walled nature of the atrial wall can lead to numerical locking issues when using 3D models discretized with standard finite elements. In order to circumvent these issues, we introduce a comprehensive electromechanical model of the left atrium based on a 3D-shell formulation. The model integrates both the passive and active components of the atrial tissue, while blood flow and the mitral valve dynamics are described in a lumped parameter fashion. The resulting model is discretized with a finite element approach specifically designed to mitigate numerical locking. The effectiveness of the proposed approach is evaluated by comparing the numerical results with biomarkers reported in the literature, in the case of both healthy and pathological conditions.
- Open Access
A fictitious domain method with enhanced interfacial mass conservation for immersed FSI with thin-walled solids
In this paper, we extend the low-order fictitious domain method with enhanced mass conservation, introduced in [ESAIM: Math. Model. Numer. Anal., 58(1):303--333, 2024], to fluid-structure interaction with immersed thin-walled solids. The key idea is to improve mass conservation across the interface by imposing a single global velocity constraint on one side of the interface using a scalar Lagrange multiplier. Both 2D and 3D shell models are considered for the description of the solid, including contact between solids. For both models, the interface coupling is enforced on the mid-surface of the shell using a stabilized Lagrange multiplier formulation. Numerical examples in two and three dimensions illustrate the effectiveness of the proposed method, including its successful application to the simulation of aortic heart valve dynamics.
Open AccessA fictitious domain method with enhanced interfacial mass conservation for immersed FSI with thin-walled solids
In this paper, we extend the low-order fictitious domain method with enhanced mass conservation, introduced in [ESAIM: Math. Model. Numer. Anal., 58(1):303--333, 2024], to fluid-structure interaction with immersed thin-walled solids. The key idea is to improve mass conservation across the interface by imposing a single global velocity constraint on one side of the interface using a scalar Lagrange multiplier. Both 2D and 3D shell models are considered for the description of the solid, including contact between solids. For both models, the interface coupling is enforced on the mid-surface of the shell using a stabilized Lagrange multiplier formulation. Numerical examples in two and three dimensions illustrate the effectiveness of the proposed method, including its successful application to the simulation of aortic heart valve dynamics.
- Open Access
- 11 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
A biomechanics-based parametrized cardiac end-diastolic pressure–volume relationship for accurate patient-specific calibration and estimation
A simple power law has been proposed in the pioneering work of Klotz et al. (Am J Physiol Heart Circ Physiol 291(1):H403–H412, 2006) to approximate the end-diastolic pressure–volume relationship of the left cardiac ventricle, with limited inter-individual variability provided the volume is adequately normalized. Nevertheless, we use here a biomechanical model to investigate the sources of the remaining data dispersion observed in the normalized space, and we show that variations of the parameters of the biomechanical model realistically account for a substantial part of this dispersion. We therefore propose an alternative law based on the biomechanical model that embeds some intrinsic physical parameters, which directly enables personalization capabilities, and paves the way for related estimation approaches.
- 11 July 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessA biomechanics-based parametrized cardiac end-diastolic pressure–volume relationship for accurate patient-specific calibration and estimation
A simple power law has been proposed in the pioneering work of Klotz et al. (Am J Physiol Heart Circ Physiol 291(1):H403–H412, 2006) to approximate the end-diastolic pressure–volume relationship of the left cardiac ventricle, with limited inter-individual variability provided the volume is adequately normalized. Nevertheless, we use here a biomechanical model to investigate the sources of the remaining data dispersion observed in the normalized space, and we show that variations of the parameters of the biomechanical model realistically account for a substantial part of this dispersion. We therefore propose an alternative law based on the biomechanical model that embeds some intrinsic physical parameters, which directly enables personalization capabilities, and paves the way for related estimation approaches.
- Open Access
Essai d'une nouvelle analyse de la mortalité causée par la petite vérole, et des avantages de l'inoculation pour la prévenir
Mémoires de Mathématique et de Physique, tirés des registres de l'Académie Royale des Sciences de l'année 1760, pages 1-45
Open AccessEssai d'une nouvelle analyse de la mortalité causée par la petite vérole, et des avantages de l'inoculation pour la prévenir
Mémoires de Mathématique et de Physique, tirés des registres de l'Académie Royale des Sciences de l'année 1760, pages 1-45
- 21 October 2022
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 38 (12) , e3655
Varying thin filament activation in the framework of the Huxley'57 model
Muscle contraction is triggered by the activation of the actin sites of the thin filament by calcium ions. It results that the thin filament activation level varies over time. Moreover, this activation process is also used as a regulation mechanism of the developed force. Our objective is to build a model of varying actin site activation level within the classical Huxley'57 two‐state framework. This new model is obtained as an enhancement of a previously proposed formulation of the varying thick filament activation within the same framework. We assume that the state of an actin site depends on whether it is activated and whether it forms a cross‐bridge with the associated myosin head, which results in four possible states. The transitions between the actin site states are controlled by the global actin sites activation level and the dynamics of these transitions is coupled with the attachment–detachment process. A preliminary calibration of the model with experimental twitch contraction data obtained at varying sarcomere lengths is performed.
- 21 October 2022
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 38 (12) , e3655
Varying thin filament activation in the framework of the Huxley'57 model
Muscle contraction is triggered by the activation of the actin sites of the thin filament by calcium ions. It results that the thin filament activation level varies over time. Moreover, this activation process is also used as a regulation mechanism of the developed force. Our objective is to build a model of varying actin site activation level within the classical Huxley'57 two‐state framework. This new model is obtained as an enhancement of a previously proposed formulation of the varying thick filament activation within the same framework. We assume that the state of an actin site depends on whether it is activated and whether it forms a cross‐bridge with the associated myosin head, which results in four possible states. The transitions between the actin site states are controlled by the global actin sites activation level and the dynamics of these transitions is coupled with the attachment–detachment process. A preliminary calibration of the model with experimental twitch contraction data obtained at varying sarcomere lengths is performed.
- 30 March 2022
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 144 (9)
Estimation of Regional Pulmonary Compliance in Idiopathic Pulmonary Fibrosis Based on Personalized Lung Poromechanical Modeling
Pulmonary function is tightly linked to the lung mechanical behavior, especially large deformation during breathing. Interstitial lung diseases, such as idiopathic pulmonary fibrosis (IPF), have an impact on the pulmonary mechanics and consequently alter lung function. However, IPF remains poorly understood, poorly diagnosed, and poorly treated. Currently, the mechanical impact of such diseases is assessed by pressure–volume curves, giving only global information. We developed a poromechanical model of the lung that can be personalized to a patient based on routine clinical data. The personalization pipeline uses clinical data, mainly computed tomography (CT) images at two time steps and involves the formulation of an inverse problem to estimate regional compliances. The estimation problem can be formulated both in terms of “effective”, i.e., without considering the mixture porosity, or “rescaled,” i.e., where the first-order effect of the porosity has been taken into account, compliances. Regional compliances are estimated for one control subject and three IPF patients, allowing to quantify the IPF-induced tissue stiffening. This personalized model could be used in the clinic as an objective and quantitative tool for IPF diagnosis.
- 30 March 2022
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 144 (9)
Estimation of Regional Pulmonary Compliance in Idiopathic Pulmonary Fibrosis Based on Personalized Lung Poromechanical Modeling
Pulmonary function is tightly linked to the lung mechanical behavior, especially large deformation during breathing. Interstitial lung diseases, such as idiopathic pulmonary fibrosis (IPF), have an impact on the pulmonary mechanics and consequently alter lung function. However, IPF remains poorly understood, poorly diagnosed, and poorly treated. Currently, the mechanical impact of such diseases is assessed by pressure–volume curves, giving only global information. We developed a poromechanical model of the lung that can be personalized to a patient based on routine clinical data. The personalization pipeline uses clinical data, mainly computed tomography (CT) images at two time steps and involves the formulation of an inverse problem to estimate regional compliances. The estimation problem can be formulated both in terms of “effective”, i.e., without considering the mixture porosity, or “rescaled,” i.e., where the first-order effect of the porosity has been taken into account, compliances. Regional compliances are estimated for one control subject and three IPF patients, allowing to quantify the IPF-induced tissue stiffening. This personalized model could be used in the clinic as an objective and quantitative tool for IPF diagnosis.
- 24 January 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 21 (2) , 527-551
A quasi-static poromechanical model of the lungs
The lung vital function of providing oxygen to the body heavily relies on its mechanical behavior and the interaction with its complex environment. In particular, the large compliance and the porosity of the pulmonary tissue are critical for lung inflation and air inhalation, and the diaphragm, the pleura, the rib cage and intercostal muscles all play a role in delivering and controlling the breathing driving forces. In this paper, we introduce a novel poromechanical model of the lungs. The constitutive law is derived within a general poromechanics theory via the formulation of lung-specific assumptions, leading to a hyperelastic potential reproducing the volume response of the pulmonary mixture to a change of pressure. Moreover, physiological boundary conditions are formulated to account for the interaction of the lungs with their surroundings, including a following pressure and bilateral frictionless contact. A strategy is established to estimate the unloaded configuration from a given loaded state, with a particular focus on ensuring a positive porosity. Finally, we illustrate through several realistic examples the relevance of our model and its potential clinical applications.
- 24 January 2022
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 21 (2) , 527-551
A quasi-static poromechanical model of the lungs
The lung vital function of providing oxygen to the body heavily relies on its mechanical behavior and the interaction with its complex environment. In particular, the large compliance and the porosity of the pulmonary tissue are critical for lung inflation and air inhalation, and the diaphragm, the pleura, the rib cage and intercostal muscles all play a role in delivering and controlling the breathing driving forces. In this paper, we introduce a novel poromechanical model of the lungs. The constitutive law is derived within a general poromechanics theory via the formulation of lung-specific assumptions, leading to a hyperelastic potential reproducing the volume response of the pulmonary mixture to a change of pressure. Moreover, physiological boundary conditions are formulated to account for the interaction of the lungs with their surroundings, including a following pressure and bilateral frictionless contact. A strategy is established to estimate the unloaded configuration from a given loaded state, with a particular focus on ensuring a positive porosity. Finally, we illustrate through several realistic examples the relevance of our model and its potential clinical applications.