Madhusudhanan Balasubramanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Madhusudhanan Balasubramanian has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Ali Salehi
Computational Ocularscience Laboratory Department of Electrical & Computer Engineering, The University of Memphis, Memphis, USA
2 shared publications- Akram Belghith
Hamilton Glaucoma Center, Department of Ophthalmology and Shiley Eye Institute, University of California, San Diego, La Jolla, California
1 shared publication - Ali Salehi
Department of Electrical and Computer Engineering, The University of Memphis, Memphis, USA
1 shared publication - Behzad Fotovvati
Department of Mechanical Engineering, The University of Memphis, Memphis, TN 38152, USA
1 shared publication - Christopher Bowd
Hamilton Glaucoma Center and Division of Ophthalmology Informatics and Data Science, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California, San Diego, CA 92037, USA
1 shared publication - Ebrahim Asadi
Department of Mechanical Engineering, The University of Memphis, Memphis, USA
1 shared publication
Latest Publications
- 19 August 2023
- Published by Elsevier in Neurocomputing
- Vol. 558
SSTM: Spatiotemporal recurrent transformers for multi-frame optical flow estimation
- 19 August 2023
- Published by Elsevier in Neurocomputing
- Vol. 558
SSTM: Spatiotemporal recurrent transformers for multi-frame optical flow estimation
- Open Access
- 17 June 2023
- Published by Springer Nature in Eye
- Vol. 37 (18) , 3819-3826
Dense optic nerve head deformation estimated using CNN as a structural biomarker of glaucoma progression
Purpose To present a new structural biomarker for detecting glaucoma progression based on structural transformation of the optic nerve head (ONH) region over time. Methods Dense ONH deformation was estimated using deep learning methods namely DDCNet-Multires, FlowNet2, and FlowNetCorrelation, and legacy computational methods namely the topographic change analysis (TCA) and proper orthogonal decomposition (POD) methods. A candidate biomarker was estimated as the average magnitude of deformation of the ONH and evaluated using longitudinal confocal scans of 12 laser treated and 12 contralateral normal eyes of 12 primates from the LSU Experimental Glaucoma Study (LEGS); and 36 progressing eyes and 21 longitudinal normal eyes from the UCSD Diagnostic Innovations in Glaucoma Study (DIGS). Area under the ROC curve (AUC) was used to assess the diagnostic accuracy of the biomarker. Results AUROC (95% CI) for LEGS were: 0.83 (0.79, 0.88) for DDCNet-Multires; 0.83 (0.78, 0.88) for FlowNet2; 0.83 (0.78, 0.88) for FlowNet-Correlation; 0.94 (0.91, 0.97) for POD; and 0.86 (0.82, 0.91) for TCA methods. For DIGS: 0.89 (0.80, 0.97) for DDCNet-Multires; 0.82 (0.71, 0.93) for FlowNet2; 0.93 (0.86, 0.99) for FlowNet-Correlation; 0.86 (0.76, 0.96) for POD; and 0.86 (0.77, 0.95) for TCA methods. Lower diagnostic accuracy of the learning-based methods for LEG study eyes were due to image alignment errors in confocal sequences. Conclusion Deep learning methods trained to estimate generic deformation were able to estimate ONH deformation from image sequences and provided a higher diagnostic accuracy. Our validation of the biomarker using ONH sequences from controlled experimental conditions confirms the diagnostic accuracy of the biomarkers observed in the clinical population. Performance can be further improved by fine-tuning these networks using ONH sequences.
- 17 June 2023
- Published by Springer Nature in Eye
- Vol. 37 (18) , 3819-3826
Open AccessDense optic nerve head deformation estimated using CNN as a structural biomarker of glaucoma progression
Purpose To present a new structural biomarker for detecting glaucoma progression based on structural transformation of the optic nerve head (ONH) region over time. Methods Dense ONH deformation was estimated using deep learning methods namely DDCNet-Multires, FlowNet2, and FlowNetCorrelation, and legacy computational methods namely the topographic change analysis (TCA) and proper orthogonal decomposition (POD) methods. A candidate biomarker was estimated as the average magnitude of deformation of the ONH and evaluated using longitudinal confocal scans of 12 laser treated and 12 contralateral normal eyes of 12 primates from the LSU Experimental Glaucoma Study (LEGS); and 36 progressing eyes and 21 longitudinal normal eyes from the UCSD Diagnostic Innovations in Glaucoma Study (DIGS). Area under the ROC curve (AUC) was used to assess the diagnostic accuracy of the biomarker. Results AUROC (95% CI) for LEGS were: 0.83 (0.79, 0.88) for DDCNet-Multires; 0.83 (0.78, 0.88) for FlowNet2; 0.83 (0.78, 0.88) for FlowNet-Correlation; 0.94 (0.91, 0.97) for POD; and 0.86 (0.82, 0.91) for TCA methods. For DIGS: 0.89 (0.80, 0.97) for DDCNet-Multires; 0.82 (0.71, 0.93) for FlowNet2; 0.93 (0.86, 0.99) for FlowNet-Correlation; 0.86 (0.76, 0.96) for POD; and 0.86 (0.77, 0.95) for TCA methods. Lower diagnostic accuracy of the learning-based methods for LEG study eyes were due to image alignment errors in confocal sequences. Conclusion Deep learning methods trained to estimate generic deformation were able to estimate ONH deformation from image sequences and provided a higher diagnostic accuracy. Our validation of the biomarker using ONH sequences from controlled experimental conditions confirms the diagnostic accuracy of the biomarkers observed in the clinical population. Performance can be further improved by fine-tuning these networks using ONH sequences.
- 16 January 2023
- Published by Society for Imaging Science & Technology in Electronic Imaging
- Vol. 35 (17) , 107-5
A comparative evaluation of 3D geometries of scenes estimated using factor graph based disparity estimation algorithms
Passive stereo vision systems are useful for estimating 3D geometries from digital images similar to the human biological system. In general, two cameras are situated at a known distance from the object and simultaneously capture images of the same scene from different views. This paper presents a comparative evaluation of 3D geometries of scenes estimated by three disparity estimation algorithms, namely the hybrid stereo matching algorithm (HCS), factor graph-based stereo matching algorithm (FGS), and a multi-resolution FGS algorithm (MR-FGS). Comparative studies were conducted using our stereo imaging system as well as hand-held, consumer-market digital cameras and camera phones of a variety of makes/models. Based on our experimental results, the factor graph algorithm (FGS) and multi-resolution factor graph algorithm (MR-FGS) result in a higher level of 3D reconstruction accuracy than the HCS algorithm. When compared with the FGS algorithm, MR-FGS provides a significant improvement in the disparity contrast along the depth boundaries and minimal depth discontinuities.
- 16 January 2023
- Published by Society for Imaging Science & Technology in Electronic Imaging
- Vol. 35 (17) , 107-5
A comparative evaluation of 3D geometries of scenes estimated using factor graph based disparity estimation algorithms
Passive stereo vision systems are useful for estimating 3D geometries from digital images similar to the human biological system. In general, two cameras are situated at a known distance from the object and simultaneously capture images of the same scene from different views. This paper presents a comparative evaluation of 3D geometries of scenes estimated by three disparity estimation algorithms, namely the hybrid stereo matching algorithm (HCS), factor graph-based stereo matching algorithm (FGS), and a multi-resolution FGS algorithm (MR-FGS). Comparative studies were conducted using our stereo imaging system as well as hand-held, consumer-market digital cameras and camera phones of a variety of makes/models. Based on our experimental results, the factor graph algorithm (FGS) and multi-resolution factor graph algorithm (MR-FGS) result in a higher level of 3D reconstruction accuracy than the HCS algorithm. When compared with the FGS algorithm, MR-FGS provides a significant improvement in the disparity contrast along the depth boundaries and minimal depth discontinuities.
- 26 September 2022
- Published by Springer Nature in Neural Processing Letters
- Vol. 55 (4) , 4231-4255
DDCNet-Multires: Effective Receptive Field Guided Multiresolution CNN for Dense Prediction
- 26 September 2022
- Published by Springer Nature in Neural Processing Letters
- Vol. 55 (4) , 4231-4255
DDCNet-Multires: Effective Receptive Field Guided Multiresolution CNN for Dense Prediction
- Open Access
- 16 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
A novel factor graph-based optimization technique for stereo correspondence estimation
Dense disparities among multiple views are essential for estimating the 3D architecture of a scene based on the geometrical relationship between the scene and the views or cameras. Scenes with larger extents of homogeneous textures, differing scene illumination among the multiple views and with occluding objects affect the accuracy of the estimated disparities. Markov random fields based methods for disparity estimation address these limitations using spatial dependencies among the observations and among the disparity estimates. These methods, however, are limited by spatially fixed and smaller neighborhood systems or cliques. Recent learning-based methods generate rich set of stereo features for generating cost volume and estimating disparity. In this work, we present a new factor graph-based probabilistic graphical model for disparity estimation that allows a larger and a spatially variable neighborhood structure determined based on the local scene characteristics. Our algorithm improves the accuracy of disparity estimates in stereo image pairs with varying texture and illumination characteristics by enforcing spatial dependencies among scene characteristics as well as among disparity estimates. We evaluated our method using theMiddlebury benchmark stereo datasetsand theMiddlebury evaluation dataset version 3.0and compared its performance with recent state-of-the-art disparity estimation algorithms. Our factor graph-based algorithm provided disparity estimates with higher accuracy when compared to the recent non-learning- and learning-based disparity estimation algorithms. The factor graph formulation can be used for obtainingmaximum a posterioriestimates from models or optimization problems with complex dependency structure among hidden variables. The strategies of using a priori distributions with shorter support and spatial dependencies were useful for reducing the computational cost and improving message convergence in the model. The factor-graph algorithm is also useful for other dense estimation problems such as optical flow estimation.
- 16 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-17
Open AccessA novel factor graph-based optimization technique for stereo correspondence estimation
Dense disparities among multiple views are essential for estimating the 3D architecture of a scene based on the geometrical relationship between the scene and the views or cameras. Scenes with larger extents of homogeneous textures, differing scene illumination among the multiple views and with occluding objects affect the accuracy of the estimated disparities. Markov random fields based methods for disparity estimation address these limitations using spatial dependencies among the observations and among the disparity estimates. These methods, however, are limited by spatially fixed and smaller neighborhood systems or cliques. Recent learning-based methods generate rich set of stereo features for generating cost volume and estimating disparity. In this work, we present a new factor graph-based probabilistic graphical model for disparity estimation that allows a larger and a spatially variable neighborhood structure determined based on the local scene characteristics. Our algorithm improves the accuracy of disparity estimates in stereo image pairs with varying texture and illumination characteristics by enforcing spatial dependencies among scene characteristics as well as among disparity estimates. We evaluated our method using theMiddlebury benchmark stereo datasetsand theMiddlebury evaluation dataset version 3.0and compared its performance with recent state-of-the-art disparity estimation algorithms. Our factor graph-based algorithm provided disparity estimates with higher accuracy when compared to the recent non-learning- and learning-based disparity estimation algorithms. The factor graph formulation can be used for obtainingmaximum a posterioriestimates from models or optimization problems with complex dependency structure among hidden variables. The strategies of using a priori distributions with shorter support and spatial dependencies were useful for reducing the computational cost and improving message convergence in the model. The factor-graph algorithm is also useful for other dense estimation problems such as optical flow estimation.
- Open Access
Dense Optic Nerve Head Deformation Estimated using CNN as a Structural Biomarker of Glaucoma Progression
Purpose To present a new structural biomarker for detecting glaucoma progression based on structural transformation of the optic nerve head (ONH) region. Methods A dense ONH deformation was estimated using deep learning methods namely DDCNet-Multires, FlowNet2, and FlowNet-Correlation, and legacy computational methods namely the topographic change analysis (TCA) and proper orthogonal decomposition (POD) methods using longitudinal confocal scans of the ONH for each study eye. A candidate structural biomarker of glaucoma progression in a study eye was estimated as average magnitude of flow velocities within the ONH region. The biomarker was evaluated using longitudinal confocal scans of 12 laser-treated and 12 contralateral normal eyes of 12 primates from the LSU Experimental Glaucoma Study (LEGS); and 36 progressing eyes and 21 longitudinal normal eyes from the UCSD Diagnostic Innovations in Glaucoma Study (DIGS). Area under the ROC curves (AUC) was used to assess the diagnostic accuracy of the candidate biomarker. Results AUROC (95% CI) for LEGS were: 0.83 (0.79, 0.88) for DDCNet-Multires; 0.83 (0.78, 0.88) for FlowNet2; 0.83 (0.78, 0.88) for FlowNet-Correlation; 0.94 (0.91, 0.97) for POD; and 0.86 (0.82, 0.91) for TCA methods. For DIGS: 0.89 (0.80, 0.97) for DDCNet-Multires; 0.82 (0.71, 0.93) for FlowNet2; 0.93 (0.86, 0.99) for FlowNet-Correlation; 0.86 (0.76, 0.96) for POD; and 0.86 (0.77, 0.95) for TCA methods. Lower diagnostic accuracy of the learning-based methods for LEG study eyes were due to image alignment errors in confocal sequences. Conclusion Deep learning methods trained to estimate generic deformation were able to detect ONH deformation from confocal images and provided a higher diagnostic accuracy when compared to the classical optical flow and legacy biomarkers of glaucoma progression. Because it is difficult to validate the estimates of dense ONH deformation in clinical population, our validation using ONH sequences under controlled experimental conditions confirms the diagnostic accuracy of the biomarkers observed in the clinical population. Performance of these deep learning methods can be further improved by fine-tuning these networks using longitudinal ONH sequences instead of training the network to be a general-purpose deformation estimator.
Open AccessDense Optic Nerve Head Deformation Estimated using CNN as a Structural Biomarker of Glaucoma Progression
Purpose To present a new structural biomarker for detecting glaucoma progression based on structural transformation of the optic nerve head (ONH) region. Methods A dense ONH deformation was estimated using deep learning methods namely DDCNet-Multires, FlowNet2, and FlowNet-Correlation, and legacy computational methods namely the topographic change analysis (TCA) and proper orthogonal decomposition (POD) methods using longitudinal confocal scans of the ONH for each study eye. A candidate structural biomarker of glaucoma progression in a study eye was estimated as average magnitude of flow velocities within the ONH region. The biomarker was evaluated using longitudinal confocal scans of 12 laser-treated and 12 contralateral normal eyes of 12 primates from the LSU Experimental Glaucoma Study (LEGS); and 36 progressing eyes and 21 longitudinal normal eyes from the UCSD Diagnostic Innovations in Glaucoma Study (DIGS). Area under the ROC curves (AUC) was used to assess the diagnostic accuracy of the candidate biomarker. Results AUROC (95% CI) for LEGS were: 0.83 (0.79, 0.88) for DDCNet-Multires; 0.83 (0.78, 0.88) for FlowNet2; 0.83 (0.78, 0.88) for FlowNet-Correlation; 0.94 (0.91, 0.97) for POD; and 0.86 (0.82, 0.91) for TCA methods. For DIGS: 0.89 (0.80, 0.97) for DDCNet-Multires; 0.82 (0.71, 0.93) for FlowNet2; 0.93 (0.86, 0.99) for FlowNet-Correlation; 0.86 (0.76, 0.96) for POD; and 0.86 (0.77, 0.95) for TCA methods. Lower diagnostic accuracy of the learning-based methods for LEG study eyes were due to image alignment errors in confocal sequences. Conclusion Deep learning methods trained to estimate generic deformation were able to detect ONH deformation from confocal images and provided a higher diagnostic accuracy when compared to the classical optical flow and legacy biomarkers of glaucoma progression. Because it is difficult to validate the estimates of dense ONH deformation in clinical population, our validation using ONH sequences under controlled experimental conditions confirms the diagnostic accuracy of the biomarkers observed in the clinical population. Performance of these deep learning methods can be further improved by fine-tuning these networks using longitudinal ONH sequences instead of training the network to be a general-purpose deformation estimator.
- Open Access
Modeling and Optimization Approaches of Laser-Based Powder-Bed Fusion Process for Ti-6Al-4V Alloy
Laser-based powder-bed fusion (L-PBF) is a widely used additive manufacturing technology that contains several variables (processing parameters), which makes it challenging to correlate them with the desired properties (responses) when optimizing the responses. In this study, the influence of the five most influential L-PBF processing parameters of Ti-6Al-4V alloy—laser power, scanning speed, hatch spacing, layer thickness, and stripe width—on the relative density, microhardness, and various line and surface roughness parameters for the top, upskin, and downskin surfaces are thoroughly investigated. Two design of experiment (DoE) methods, including Taguchi L25 orthogonal arrays and fractional factorial DoE for the response surface method (RSM), are employed to account for the five L-PBF processing parameters at five levels each. The significance and contribution of the individual processing parameters on each response are analyzed using the Taguchi method. Then, the simultaneous contribution of two processing parameters on various responses is presented using RSM quadratic modeling. A multi-objective RSM model is developed to optimize the L-PBF processing parameters considering all the responses with equal weights. Furthermore, an artificial neural network (ANN) model is designed and trained based on the samples used for the Taguchi method and validated based on the samples used for the RSM. The Taguchi, RSM, and ANN models are used to predict the responses of unseen data. The results show that with the same amount of available experimental data, the proposed ANN model can most accurately predict the response of various properties of L-PBF components.
Open AccessModeling and Optimization Approaches of Laser-Based Powder-Bed Fusion Process for Ti-6Al-4V Alloy
Laser-based powder-bed fusion (L-PBF) is a widely used additive manufacturing technology that contains several variables (processing parameters), which makes it challenging to correlate them with the desired properties (responses) when optimizing the responses. In this study, the influence of the five most influential L-PBF processing parameters of Ti-6Al-4V alloy—laser power, scanning speed, hatch spacing, layer thickness, and stripe width—on the relative density, microhardness, and various line and surface roughness parameters for the top, upskin, and downskin surfaces are thoroughly investigated. Two design of experiment (DoE) methods, including Taguchi L25 orthogonal arrays and fractional factorial DoE for the response surface method (RSM), are employed to account for the five L-PBF processing parameters at five levels each. The significance and contribution of the individual processing parameters on each response are analyzed using the Taguchi method. Then, the simultaneous contribution of two processing parameters on various responses is presented using RSM quadratic modeling. A multi-objective RSM model is developed to optimize the L-PBF processing parameters considering all the responses with equal weights. Furthermore, an artificial neural network (ANN) model is designed and trained based on the samples used for the Taguchi method and validated based on the samples used for the RSM. The Taguchi, RSM, and ANN models are used to predict the responses of unseen data. The results show that with the same amount of available experimental data, the proposed ANN model can most accurately predict the response of various properties of L-PBF components.
- 18 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 16 (7) , 542-554
A Novel Nanoparticle Mediated Selective Inner Retinal Photocoagulation for Diseases of the Inner Retina
A novel nanoparticle mediated methodology for laser photocoagulation of the inner retina to achieve tissue selective treatment is presented. Methods: Transport of 527, 577, and 810 nm laser, heat deposition, and eventual thermal damage in vitreous, retina, RPE, choroid, and sclera were modeled using Bouguer-Beer-Lambert law of absorption and solved numerically using the finite volume method. Nanoparticles were designed using Mie theory of scattering. Performance of the new photocoagulation strategy using gold nanospheres and gold-silica nanoshells was compared with that of conventional methods without nanoparticles. For experimental validation, vitreous cavity of ex vivo porcine eyes was infused with gold nanospheres. After ~6 h of nanoparticle diffusion, the porcine retina was irradiated with a green laser and imaged simultaneously using a spectral domain optical coherence tomography (Spectralis SD-OCT, Heidelberg Engineering). Results: Our computational model predicted a significant spatial shift in the peak temperature from RPE to the inner retinal region when infused with nanoparticles. Arrhenius thermal damage in the mid-retinal location was achieved in ~14 ms for 527 nm laser thereby reducing the irradiation duration by ~30 ms compared with the treatment without nanoparticles. In ex vivo porcine eyes infused with gold nanospheres, SD-OCT retinal images revealed a lower thermal damage and expansion at RPE due to laser photocoagulation. Conclusion: Nanoparticle infused laser photocoagulation strategy provided a selective inner retinal thermal damage with significant decrease in laser power and laser exposure time. Significance: The proposed treatment strategy shows possibilities for an efficient and highly selective inner retinal laser treatment.
- 18 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 16 (7) , 542-554
A Novel Nanoparticle Mediated Selective Inner Retinal Photocoagulation for Diseases of the Inner Retina
A novel nanoparticle mediated methodology for laser photocoagulation of the inner retina to achieve tissue selective treatment is presented. Methods: Transport of 527, 577, and 810 nm laser, heat deposition, and eventual thermal damage in vitreous, retina, RPE, choroid, and sclera were modeled using Bouguer-Beer-Lambert law of absorption and solved numerically using the finite volume method. Nanoparticles were designed using Mie theory of scattering. Performance of the new photocoagulation strategy using gold nanospheres and gold-silica nanoshells was compared with that of conventional methods without nanoparticles. For experimental validation, vitreous cavity of ex vivo porcine eyes was infused with gold nanospheres. After ~6 h of nanoparticle diffusion, the porcine retina was irradiated with a green laser and imaged simultaneously using a spectral domain optical coherence tomography (Spectralis SD-OCT, Heidelberg Engineering). Results: Our computational model predicted a significant spatial shift in the peak temperature from RPE to the inner retinal region when infused with nanoparticles. Arrhenius thermal damage in the mid-retinal location was achieved in ~14 ms for 527 nm laser thereby reducing the irradiation duration by ~30 ms compared with the treatment without nanoparticles. In ex vivo porcine eyes infused with gold nanospheres, SD-OCT retinal images revealed a lower thermal damage and expansion at RPE due to laser photocoagulation. Conclusion: Nanoparticle infused laser photocoagulation strategy provided a selective inner retinal thermal damage with significant decrease in laser power and laser exposure time. Significance: The proposed treatment strategy shows possibilities for an efficient and highly selective inner retinal laser treatment.
- 1 June 2015
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 64 (2) , 105-115
Learning from healthy and stable eyes: A new approach for detection of glaucomatous progression
- 1 June 2015
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 64 (2) , 105-115
Learning from healthy and stable eyes: A new approach for detection of glaucomatous progression