  • Open Access

    Validation of Methods in Medical Laboratories, ISO Standards, CLSI Guidelines, and Recommendations: A Point of View

    by Marco Pradella

    This note is intended to address the concepts contained in certain requirements of ISO 15189:2022, in comparison with selected regulatory sources and guidelines. ISO 15189 contains two concepts that are often confused: method verification and method validation. Some recent sources provide tools to clearly understand these concepts and put them into practice. These include the CLSI EP49:2025 guideline, the ISO/AWI TS 17849 draft, and the ISO 20916:2019 and ISO 5649:2024 standards. In addition to these, there are the SIPMeL Q21:2024 Recommendations, which combine the requirements of ISO 15189 with useful additions from other ISO and CLSI sources. In this note, the author presents the results of a source analysis that highlights significant lexical and conceptual issues, particularly in CLSI EP49. However, the body of sources currently available provides laboratories and developers of in vitro diagnostic test methods with many tools to achieve the objectives set forth by ISO accreditation requirements and to operate in a manner that benefits patients and physicians who rely on the services of these laboratories. Despite the brevity required by the format of this presentation, it is hoped that the observations set forth here may be discussed, confirmed, or even refuted by other viewpoints.

  • Open Access

    Digitalization, Digital Maturity and Information Security of Processes: Standard ISO 15189, ISO 17025, and EUROLAB Guide

    by Marco Pradella

    Testing and medical laboratories have been undergoing a process of progressive, unstoppable digitalization. The digitalization of laboratories carries risks for information security. There are differences between medical laboratories according to International Organization for Standardization (ISO) 15189 and testing laboratories according to ISO 17025. ISO 15189 refers to information security based on ISO 27001, while ISO 17025 is limited to certain clauses. Medical laboratories can use the guidelines with sources from Clinical & Laboratory Standards Institute (CLSI) documents. The European Federation of National Associations of Measurement, Testing, and Analysis Laboratories (EUROLAB) provides a guide to digitalization security that combines ISO 17025 requirements with ISO 27001 controls. The Italian Society of Clinical Pathology and Laboratory Medicine (SIPMeL) Q18R1 Recommendations regarding requirements for medical laboratory information systems confirm that laboratories should obtain at least ISO/IEC 27001 certification.

  • Open Access

    Decision Rules for Measurement Results in Testing and Medical Laboratories with ISO Accreditation Requirements

    by Marco Pradella

    The work of the laboratories does not end with the measurement or examination results. However, there are significant differences between medical laboratories and testing laboratories in how they handle results. Comparing the two approaches, useful insights can be gained regarding both metrological concepts and the practice of activities. Testing laboratories have always been confronted with the interpretation of measurement results to make decisions, in relation to the intended users of test reports, based on threshold values and measurement uncertainty. In medical laboratories, the approach is quite different. For ISO 15189 accreditation requirements recipients of test results are given interpretive criteria provided by reference intervals, decision limits and differences from previous results. Constantly improving guidelines are available for this. However, critical points emerge that laboratories must take into account, involving both formal and content aspects. Some of these critical issues have been highlighted in the official SIPMeL recommendations. The laboratories can choose different criteria for interpreting test results: either relying primarily on measurement uncertainty or aligning as closely as possible with medical decision-making.


  • Open Access

    Measurement Uncertainty: New Definition, Viewpoints, and Laboratories

    by Marco Pradella

    The Joint Committee for Guides in Metrology (JCGM) today presents a definition of measurement uncertainty that modifies the previous one and improves the management of scenarios other than scalar (quantitative) measurements, such as classificatory or qualitative (nominal and ordinal) properties. Nominal results are often found in biology and medicine. For the accreditation of medical laboratories and testing laboratories, both ISO 15189 and ISO 17025 require the management of these situations, using the professional expertise of specialists with the support of manufacturers. Some of the members of JCGM WG2 developed a discussion on the concept of measurement uncertainty and raised some criticisms. ISO produces detailed guides for this purpose, such as ISO 20914, ISO 27877, ISO 16393, ISO 20397-2, and ISO 22692. Laboratories now have all the tools they need to meet accreditation requirements on uncertainty.


  • Open Access

    Internal Quality Control in Medical Laboratories: Westgard and the Others

    by Marco Pradella

    This review recalls some ISO 15189:2022 requirements for the management of examination results and emerging alternatives to internal quality control (IQC) in relation to Italian Society of Clinical Pathology and Laboratory Medicine (SIPMeL) Recommendation Q19. We observed phenomena of contrasting “metrological”, or rather “tracealogic”, and “statistical” approaches. SIPMeL Recommendation Q19 enhances IQC with a moving average based on ISO 15189, which enables the use of the moving average of patient sample results (MA). In the veterinary field, the procedure of QC with repeat testing on patient samples (RPT-QC) has met with some success. The “Bayesian approach” of IQC makes use of the distinction between a priori probability, evidential probability (data) and a posteriori probability (IQC rules). SIPMeL Recommendation Q19 strictly adheres to the ISO 15189:2022 document. SIPMeL Q19 calls for abandoning the 1–2 s rule, using appropriate computer tools, not only control charts, and trying to reduce false positives to very low frequencies. Alternatives to IQC using patient results and the Bayesian approach are compatible with ISO 15189 and SIPMeL Q19. In contrast, the alternative using material designed for traceability with assigned values, is not compatible with the ISO standard.


  • Open Access

    Internal Quality Control in Medical Laboratories: Westgard and the Others

    by Marco Pradella

    This review recalls some ISO 15189:2022 requirements for the management of examination results and emerging alternatives for internal quality control (IQC), in relation to Italian Society of Clinical Pathology and Laboratory Medicine (SIPMeL) Recommendations Q19. We have observed phenomena of contrasting “metrological,” or rather “tracealogic,” and “statistical” approaches. SIPMeL Recommendation Q19 picks up IQC with moving average from ISO 15189, which provides for the use of moving average of patient sample results (MA). In the veterinary field the procedure of QC with repeat testing on patient samples (RPT-QC) has met with some success. The “bayesian approach” of IQC making use of the distinction between a priori probability, evidential probability (data) and a posteriori probability (IQC rules). SIPMeL recommendations Q19 strictly adhere to ISO 15189:2022 document. SIPMeL Q19 calls for abandoning the 1-2s rule, using appropriate computer tools, not only control charts, and trying to reduce false positives to very low frequencies. The alternatives to IQC with patient results and Bayesian approach are compatible with ISO 15189 and SIPMeL Q19. In contrast, the alternative with material designed for traceability, with assigned value, is not compatible with ISO standard.


  • Open Access

    Are the Metrology Vocabulary (JCGM VIM) and the ISO and CLSI Vocabulary for Medical Laboratories Divergent?

    by Marco Pradella

    Medical laboratories are perhaps the largest measurement industry in the world. The metrology terminology is relevant for effective and efficient communication, particularly where metrology activities are carried out by operators with different metrology skills. The World Association of Societies of Pathology and Laboratory Medicine (WASPaLM) and SIPMeL have had some opportunities to propose changes to the documents in preparation for the Clinical and Laboratory Standards Institute (CLSI) and the ISO/TC 212 in order to harmonize the terminology with the Metrology Vocabulary (VIM) of the Joint Committee for Guides in Metrology (JCGM). Many proposals have been accepted. Here, we summarize some particularly critical points for metrological terms. The main terms discussed are the following: measuring, measuring range, examination, pre-examination, post-examination, manufacturer, measuring instrument, quantitative, qualitative, semi-quantitative, processing, measurement error, maximum permissible error of measurement, total error of measurement, monitoring, variability, performance, reliability, influence, interference, selectivity, sensitivity, detection limit, reliability, comparability, compatibility, control material. Despite all the efforts to coordinate terminologies, it is inevitable that overlapping and inconsistent terminologies will continue to be used because documents and policies are produced in different contexts. In some ISO/TC 212 and CLSI documents, the phenomenon of magnetic attraction toward common words (such as “analysis” and derivatives), without any consideration of the true metrological meaning, is noted. The ISO/TC 212 and CLSI working groups show, alongside moments of openness, phenomena of true self-referential conservatism.


  • Open Access

    Are the Metrology Vocabulary and the ISO Vocabulary Divergent?

    by Marco Pradella

    Medical laboratories are perhaps the largest measurement industry in the world. The metrology terminology is relevant for effective and efficient communication, particularly where metrology activities are carried out by operators with different metrology skills. WASPaLM and SIPMeL have had some opportunities to propose changes to the documents in preparation to CLSI and ISO in order to harmonise the terminology with the Metrology Vocabulary (VIM). Many proposals have been accepted. Here we summarise some particularly critical points for metrological terms. The main terms discussed are: Measuring, measuring range, examination, pre-examination, post-examination, manufacturer, measuring instrument, quantitative, qualitative, semi-quantitative, processing, easurement error, maximum permissible error of measurement, total error of measurement, monitoring, variability, performance, reliability, influence, interference, selectivity, sensitivity, detection limit, reliability, pomparability, compatibility, control material. Despite all efforts to coordinate terminologies, it is inevitable that overlapping and inconsistent terminologies will continue to be used because documents and policies are produced in different contexts. In some ISO and CLSI documents, phenomena of magnetic attraction towards common words (such as “analysis” and derivatives), without any consideration of the true metrological meaning, are noted. The ISO and CLSI working groups show, alongside moments of openness, phenomena of true self-referential conservatism.