Marta Litynska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marta Litynska has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Svitlana Kyrii
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
6 shared publications - Tetiana Dontsova
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
6 shared publications - Anna Gusak
Igor Sikorsky Kyiv Polytechnic Institute
3 shared publications - Viktor Kurylenko
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
3 shared publications - Grigorii Krimets
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
2 shared publications - Igor Astrelin
Department of Chemistry, National Technical University of Ukraine "KPI", Kyiv, 03056, Ukraine
2 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by IWA Publishing in Water Quality Research Journal
Water quality monitoring challenges during the war in Ukraine: new contaminants and approaches to their detection
Graphical overview of water pollution and monitoring under conflict conditions. Water pollutants are grouped into conflict-related contaminants, including explosive compounds, ammunition additives, uranium and heavy metals; conventional pollutants, including nutrients, heavy metals and organic matter; and hazardous pollutants also occurring in civilian activities, including petroleum hydrocarbons, pesticides, phenols, pharmaceuticals, personal care products and microplastics. A hybrid monitoring concept combines laboratory ex situ analysis, field in situ measurements and remote monitoring. These monitoring approaches are supported by a four-level digital framework consisting of sensor networks, analytics and Big Data, decision support, and an integrative level. The article provides a critical assessment of the ability of routine water quality monitoring systems to operate under armed conflict conditions, using Ukraine as a case study. Conventional pollutants (metals, nutrients, organic contamination, and emerging environmental threats, including pharmaceuticals and microplastics), are provided. Particular attention is paid to substances that are specific to wartime conditions, including explosive compounds, fuel and lubricant components, and metals derived from munitions. It is shown that infrastructure damage, electricity shortages, restricted access to monitoring sites, and disruption of laboratory operations can distort results or fully halt classical ex situ monitoring, creating spatial and temporal data gaps. Against conflict specific requirements, including personnel safety, rapid diagnostics, and data continuity, the performance of laboratory, in situ, and remote sensing approaches are evaluated. The analysis supports implementation of hybrid monitoring architectures that combine satellite Earth observation, use of UAVs for sampling or reconnaissance, and mobile laboratories for confirmatory analysis, complemented by portable test systems for rapid screening. Priorities for digitalization of crisis monitoring are formulated, including deployment of IoT based sensors, data standardization, and development of a Big Data platform with an interactive map to support early warning systems and post war recovery planning.
- 12 October 2026
- Published by IWA Publishing in Water Quality Research Journal
Open AccessWater quality monitoring challenges during the war in Ukraine: new contaminants and approaches to their detection
Graphical overview of water pollution and monitoring under conflict conditions. Water pollutants are grouped into conflict-related contaminants, including explosive compounds, ammunition additives, uranium and heavy metals; conventional pollutants, including nutrients, heavy metals and organic matter; and hazardous pollutants also occurring in civilian activities, including petroleum hydrocarbons, pesticides, phenols, pharmaceuticals, personal care products and microplastics. A hybrid monitoring concept combines laboratory ex situ analysis, field in situ measurements and remote monitoring. These monitoring approaches are supported by a four-level digital framework consisting of sensor networks, analytics and Big Data, decision support, and an integrative level. The article provides a critical assessment of the ability of routine water quality monitoring systems to operate under armed conflict conditions, using Ukraine as a case study. Conventional pollutants (metals, nutrients, organic contamination, and emerging environmental threats, including pharmaceuticals and microplastics), are provided. Particular attention is paid to substances that are specific to wartime conditions, including explosive compounds, fuel and lubricant components, and metals derived from munitions. It is shown that infrastructure damage, electricity shortages, restricted access to monitoring sites, and disruption of laboratory operations can distort results or fully halt classical ex situ monitoring, creating spatial and temporal data gaps. Against conflict specific requirements, including personnel safety, rapid diagnostics, and data continuity, the performance of laboratory, in situ, and remote sensing approaches are evaluated. The analysis supports implementation of hybrid monitoring architectures that combine satellite Earth observation, use of UAVs for sampling or reconnaissance, and mobile laboratories for confirmatory analysis, complemented by portable test systems for rapid screening. Priorities for digitalization of crisis monitoring are formulated, including deployment of IoT based sensors, data standardization, and development of a Big Data platform with an interactive map to support early warning systems and post war recovery planning.
- Open Access
- 5 September 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 45 (2) , 14-27
OPTIMIZATION OF COLORIMETRIC CONDITIONS FOR THE DETECTION OF NI(II) AND PB(II) IONS AS A BASIS FOR PORTABLE INDICATOR TEST SYSTEMS
Contamination of natural and anthropogenically affected water bodies with heavy metal ions requires the development of simple, accessible, and rapid methods for preliminary analytical control. Indicator systems for the detection of Ni(II) and Pb(II) ions are of particular importance. They can be used for rapid water screening without complex laboratory equipment. The aim of this study was to establish rational conditions for the colorimetric determination of Ni(II) and Pb(II) in aqueous solutions. These conditions were considered as a basis for the further development of portable indicator test systems. Ni(II) was determined using a complexation reaction with dimethylglyoxime in an alkaline medium in the presence of iodine. Pb(II) was determined using a reaction with arsenazo III. The effects of color development time, the amount of chromogenic reagents, and, for Pb(II), the acidity of the medium on the intensity of the analytical signal were studied. It was found that the optimal conditions for Ni(II) determination involved the addition of 1 mL of 0.05 M iodine solution and 1 mL of 1% dimethylglyoxime solution in 20% NaOH. Photometric measurement was performed after 15 min at 470 nm. For Pb(II), the optimal conditions involved the addition of 1 mL of 0.05% arsenazo III solution. Photometric measurement was performed after 30 min at 600 nm. It was shown that an excess of reagents did not improve the analytical signal. In some cases, it decreased the signal intensity or reduced reproducibility. The obtained results confirm the prospects of using the studied reactions to create drop-type or solid-phase indicator systems for the rapid detection of Ni(II) and Pb(II) in water.
- 5 September 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 45 (2) , 14-27
Open AccessOPTIMIZATION OF COLORIMETRIC CONDITIONS FOR THE DETECTION OF NI(II) AND PB(II) IONS AS A BASIS FOR PORTABLE INDICATOR TEST SYSTEMS
Contamination of natural and anthropogenically affected water bodies with heavy metal ions requires the development of simple, accessible, and rapid methods for preliminary analytical control. Indicator systems for the detection of Ni(II) and Pb(II) ions are of particular importance. They can be used for rapid water screening without complex laboratory equipment. The aim of this study was to establish rational conditions for the colorimetric determination of Ni(II) and Pb(II) in aqueous solutions. These conditions were considered as a basis for the further development of portable indicator test systems. Ni(II) was determined using a complexation reaction with dimethylglyoxime in an alkaline medium in the presence of iodine. Pb(II) was determined using a reaction with arsenazo III. The effects of color development time, the amount of chromogenic reagents, and, for Pb(II), the acidity of the medium on the intensity of the analytical signal were studied. It was found that the optimal conditions for Ni(II) determination involved the addition of 1 mL of 0.05 M iodine solution and 1 mL of 1% dimethylglyoxime solution in 20% NaOH. Photometric measurement was performed after 15 min at 470 nm. For Pb(II), the optimal conditions involved the addition of 1 mL of 0.05% arsenazo III solution. Photometric measurement was performed after 30 min at 600 nm. It was shown that an excess of reagents did not improve the analytical signal. In some cases, it decreased the signal intensity or reduced reproducibility. The obtained results confirm the prospects of using the studied reactions to create drop-type or solid-phase indicator systems for the rapid detection of Ni(II) and Pb(II) in water.
- Open Access
- 18 June 2026
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 3 (3(89)) , 6-12
Development of a quick, simple and low-cost test for iron content determination in surface and marine water
Military operations in Ukraine have intensified the challenge of monitoring water bodies and have created a strong demand for a rapid, simple, and low-cost method for iron screening under limited laboratory control. The object of research is an indicator colorimetric test system intended for fast determination of iron concentration in surface and marine waters under field conditions. To select the test formulation, two chromogenic reagents, potassium thiocyanate (KSCN) and sulfosalicylic acid, as well as pH adjusters, 10% NH4OH and 5N H2SO4, were compared using spectrophotometric characteristics in model waters containing 1 and 5 mg/L of Fe(III). It was established that, at both iron levels, the KSCN and H2SO4 combination provides the highest color intensity and the best visual contrast. The sulfosalicylic acid system produces a less contrasted signal, and the yellow shades formed in alkaline medium are difficult to distinguish reliably by visual inspection and therefore complicate detection. The thiocyanate complex was shown to be sufficiently stable for field readout since during the first 10 minutes after mixing the absorbance decreases by less than 5% and the change is not visually perceptible. A color scale covering 0 to 10 mg/L of Fe(III) was developed together with a test protocol that involves adding 25 ml of the sample, 2.5 ml of 5N H2SO4, and 1 g of KSCN, followed by reading after approximately 2 minutes by comparing the solution color with the scale. The developed test systems are recommended for rapid monitoring of iron in natural waters. The kit can be implemented in a “cylinder – ampoule – sachet – scale configuration”, which reduces reagent dosing steps and supports use outside the laboratory. Results can be documented using smartphone photography followed by RGB based color coding.
- 18 June 2026
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 3 (3(89)) , 6-12
Open AccessDevelopment of a quick, simple and low-cost test for iron content determination in surface and marine water
Military operations in Ukraine have intensified the challenge of monitoring water bodies and have created a strong demand for a rapid, simple, and low-cost method for iron screening under limited laboratory control. The object of research is an indicator colorimetric test system intended for fast determination of iron concentration in surface and marine waters under field conditions. To select the test formulation, two chromogenic reagents, potassium thiocyanate (KSCN) and sulfosalicylic acid, as well as pH adjusters, 10% NH4OH and 5N H2SO4, were compared using spectrophotometric characteristics in model waters containing 1 and 5 mg/L of Fe(III). It was established that, at both iron levels, the KSCN and H2SO4 combination provides the highest color intensity and the best visual contrast. The sulfosalicylic acid system produces a less contrasted signal, and the yellow shades formed in alkaline medium are difficult to distinguish reliably by visual inspection and therefore complicate detection. The thiocyanate complex was shown to be sufficiently stable for field readout since during the first 10 minutes after mixing the absorbance decreases by less than 5% and the change is not visually perceptible. A color scale covering 0 to 10 mg/L of Fe(III) was developed together with a test protocol that involves adding 25 ml of the sample, 2.5 ml of 5N H2SO4, and 1 g of KSCN, followed by reading after approximately 2 minutes by comparing the solution color with the scale. The developed test systems are recommended for rapid monitoring of iron in natural waters. The kit can be implemented in a “cylinder – ampoule – sachet – scale configuration”, which reduces reagent dosing steps and supports use outside the laboratory. Results can be documented using smartphone photography followed by RGB based color coding.
- Open Access
- 30 April 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 44 (1) , 13-20
PROSPECTS FOR THE APPLICATION OF ZINC OXIDE SYNTHESIZED BY HYDROTHERMAL METHOD
Nanostructured oxides with photocatalytic properties are promising materials for use in such directions as water treatment from organic pollutants and production of self-cleaning coatings. Purification is carried out due to the gradual degradation of organic pollutants under the action of radicals formed on the surface of the photocatalyst. Zinc oxide is one of the effective photocatalytic materials. The article investigates the effect of synthesis conditions on the properties of zinc oxide. Zinc hydroxide was precipitated from a zinc acetate solution by a sodium hydroxide solution. In order to reduce the size of the crystallites, before precipitation the zinc acetate solution was mixed with a guar gum solution. The resulting suspension was heat-treated in a sealed container without air access at a temperature of 110 °C. After that, the material was filtered, washed and heated at temperatures of 150 °C and 500 °C. The composition of the samples was studied by X-ray diffraction. It was found that the use of the hydrothermal method with heat treatment at a temperature of 150 °C allows obtaining a mixture of hexagonal crystalline modification of zinc oxide, cubic crystalline modification of zinc oxide and smithsonite. After heating at a temperature of 500 °C, only hexagonal modification of zinc oxide was obtained. The photocatalytic efficiency was investigated using solutions of congo red and crystal violet. It was determined that the presence of cubic modification of zinc oxide in the material increases the efficiency of the photocatalyst. This makes the material a promising photocatalyst both in the context of water treatment and in applying of self-cleaning coatings.
- 30 April 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 44 (1) , 13-20
Open AccessPROSPECTS FOR THE APPLICATION OF ZINC OXIDE SYNTHESIZED BY HYDROTHERMAL METHOD
Nanostructured oxides with photocatalytic properties are promising materials for use in such directions as water treatment from organic pollutants and production of self-cleaning coatings. Purification is carried out due to the gradual degradation of organic pollutants under the action of radicals formed on the surface of the photocatalyst. Zinc oxide is one of the effective photocatalytic materials. The article investigates the effect of synthesis conditions on the properties of zinc oxide. Zinc hydroxide was precipitated from a zinc acetate solution by a sodium hydroxide solution. In order to reduce the size of the crystallites, before precipitation the zinc acetate solution was mixed with a guar gum solution. The resulting suspension was heat-treated in a sealed container without air access at a temperature of 110 °C. After that, the material was filtered, washed and heated at temperatures of 150 °C and 500 °C. The composition of the samples was studied by X-ray diffraction. It was found that the use of the hydrothermal method with heat treatment at a temperature of 150 °C allows obtaining a mixture of hexagonal crystalline modification of zinc oxide, cubic crystalline modification of zinc oxide and smithsonite. After heating at a temperature of 500 °C, only hexagonal modification of zinc oxide was obtained. The photocatalytic efficiency was investigated using solutions of congo red and crystal violet. It was determined that the presence of cubic modification of zinc oxide in the material increases the efficiency of the photocatalyst. This makes the material a promising photocatalyst both in the context of water treatment and in applying of self-cleaning coatings.
- 2 January 2026
- Published by Springer Nature
- p. 483-492
Nanostructured Biochar-Based Composites for Wastewater Treatment and Soil Remediation
- 2 January 2026
- Published by Springer Nature
- p. 483-492
Nanostructured Biochar-Based Composites for Wastewater Treatment and Soil Remediation
- 2 January 2026
- Published by Springer Nature
- p. 141-152
Existing Methods and Nanostructured Membranes for Determining Nitrate Ions
- 2 January 2026
- Published by Springer Nature
- p. 141-152
Existing Methods and Nanostructured Membranes for Determining Nitrate Ions
- Open Access
- 28 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 43 (3) , 48-56
USING ARTIFICIAL INTELLIGENCE FOR SELECTION OF ANALYTICAL REAGENTS, EXEMPLIFIED BY DETERMINATION OF IRON CONTENT IN WATER SAMPLES
Currently, education and science in Ukraine are facing many new challenges, including war. These challenges determine new priority areas of science and technology development, which in turn affects scientists and students of higher education institutions. The significant pollution of natural resources (marine environment, surface waters and soils) caused by active military operations is the reason for the emergence of many new research projects Students of higher education institutions, especially chemical, environmental, and technical majors, often face the problem of choosing the analysis methods they will use in the experimental part of their coursework or thesis. Also students often engage in scientific research, sometimes even within the framework of various projects, including those related to monitoring the marine environment of Ukraine. Traditionally, the selection process is accompanied by a lengthy and laborious literature search. But in recent years, the rapid development of artificial intelligence has made it possible to significantly simplify this process. The article is devoted to studying the relevance of information that ChatGPT-4o mini provided in response to different formulations of prompts. The search concerned the selection of analytical reagents for determining the iron content in water samples. By improving the prompts step by step, recommendations for reagents for simultaneous determining of Fe(II) and Fe(III) in water was received from ChatGPT-4o mini. The prompts were gradually made more complicated by introducing limitations on application and reaction conditions. It was found that currently ChatGPT-4o mini did not always effectively cope with the selection of reagents, but it can somewhat simplify the literature search. However, it's possible that future versions of ChatGPT will feature a more efficient reagent selection process.
- 28 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 43 (3) , 48-56
Open AccessUSING ARTIFICIAL INTELLIGENCE FOR SELECTION OF ANALYTICAL REAGENTS, EXEMPLIFIED BY DETERMINATION OF IRON CONTENT IN WATER SAMPLES
Currently, education and science in Ukraine are facing many new challenges, including war. These challenges determine new priority areas of science and technology development, which in turn affects scientists and students of higher education institutions. The significant pollution of natural resources (marine environment, surface waters and soils) caused by active military operations is the reason for the emergence of many new research projects Students of higher education institutions, especially chemical, environmental, and technical majors, often face the problem of choosing the analysis methods they will use in the experimental part of their coursework or thesis. Also students often engage in scientific research, sometimes even within the framework of various projects, including those related to monitoring the marine environment of Ukraine. Traditionally, the selection process is accompanied by a lengthy and laborious literature search. But in recent years, the rapid development of artificial intelligence has made it possible to significantly simplify this process. The article is devoted to studying the relevance of information that ChatGPT-4o mini provided in response to different formulations of prompts. The search concerned the selection of analytical reagents for determining the iron content in water samples. By improving the prompts step by step, recommendations for reagents for simultaneous determining of Fe(II) and Fe(III) in water was received from ChatGPT-4o mini. The prompts were gradually made more complicated by introducing limitations on application and reaction conditions. It was found that currently ChatGPT-4o mini did not always effectively cope with the selection of reagents, but it can somewhat simplify the literature search. However, it's possible that future versions of ChatGPT will feature a more efficient reagent selection process.
- Open Access
- 28 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 42 (2) , 35-49
MODERN APPROACHES TO MONITORING THE CONTENT OF HEAVY METALS IN MARINE WATERS
The article describes the sources of pollution of sea water with heavy metal compounds, including copper, chromium, tin, nickel and cobalt ions, their impact on the ecosystem, as well as possible methods of detecting these pollutants. In Ukraine, before the start of hostilities, were river runoff and the discharge of insufficiently treated industrial wastewater were the main sources of heavy metal compounds entering the Black Sea and the Sea of Azov. After the start of the war, industry in the southern regions experienced a reduction in volumes, but a new source of pollution appeared, namely sunken military equipment, shells, mines, cartridges, etc. Alloys with a high content of various heavy metals are widely used in military equipment and weapons to give the alloys corrosion resistance and the necessary mechanical characteristics. With prolonged exposure to water, as a result of interaction with both the water itself and with impurities dissolved in it or existing microorganisms, metal ions are gradually leached into the water. Heavy metals not only harm marine biota, but also have the properties of bioaccumulation and biomagnification. As a result, the content of heavy metals in predatory fish and marine mammals increases significantly, and commercial fishing is threatened due to the possible non-compliance of the caught fish with sanitary and hygienic requirements. In order to timely detect and eliminate sources of pollution of marine waters with heavy metals, constant monitoring of the quality of marine waters is necessary. There are a large number of monitoring tools, including electrochemical sensors, but one of the fastest, cheapest and most convenient approaches is the use of indicator systems based on chromogenic compounds that change their color upon contact with a certain pollutant. The article considers examples of such compounds for the detection of copper, chromium, tin and nickel ions.
- 28 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 42 (2) , 35-49
Open AccessMODERN APPROACHES TO MONITORING THE CONTENT OF HEAVY METALS IN MARINE WATERS
The article describes the sources of pollution of sea water with heavy metal compounds, including copper, chromium, tin, nickel and cobalt ions, their impact on the ecosystem, as well as possible methods of detecting these pollutants. In Ukraine, before the start of hostilities, were river runoff and the discharge of insufficiently treated industrial wastewater were the main sources of heavy metal compounds entering the Black Sea and the Sea of Azov. After the start of the war, industry in the southern regions experienced a reduction in volumes, but a new source of pollution appeared, namely sunken military equipment, shells, mines, cartridges, etc. Alloys with a high content of various heavy metals are widely used in military equipment and weapons to give the alloys corrosion resistance and the necessary mechanical characteristics. With prolonged exposure to water, as a result of interaction with both the water itself and with impurities dissolved in it or existing microorganisms, metal ions are gradually leached into the water. Heavy metals not only harm marine biota, but also have the properties of bioaccumulation and biomagnification. As a result, the content of heavy metals in predatory fish and marine mammals increases significantly, and commercial fishing is threatened due to the possible non-compliance of the caught fish with sanitary and hygienic requirements. In order to timely detect and eliminate sources of pollution of marine waters with heavy metals, constant monitoring of the quality of marine waters is necessary. There are a large number of monitoring tools, including electrochemical sensors, but one of the fastest, cheapest and most convenient approaches is the use of indicator systems based on chromogenic compounds that change their color upon contact with a certain pollutant. The article considers examples of such compounds for the detection of copper, chromium, tin and nickel ions.
- 1 November 2025
- Published by Springer Nature
- p. 441-451
Nanomaterials in Detection of Fe(II) and Fe(III) in Water
- 1 November 2025
- Published by Springer Nature
- p. 441-451
Nanomaterials in Detection of Fe(II) and Fe(III) in Water
- Open Access
- 10 September 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 41 (1) , 3-7
DETERMINATION OF PHOSPHATE CONTENT IN WATER USING ORGANIC CHROMOGENIC COMPOUNDS
Phosphorus compounds are introduced into natural waters in significant quantities as a result of anthropogenic activities. Agriculture and inadequate wastewater treatment are the main sources of phosphorus compounds. Increased levels of phosphorus compounds in water bodies lead to unbalanced eutrophication and significant changes in ecosystems. Therefore, monitoring phosphate levels is very important for maintaining the normal state of aquatic ecosystems. Spectrophotometry is one of the most widely used methods for measuring phosphate concentration. In the article, we reviewed existing spectrophotometric methods for determining the phosphate content in water and proposed a new method based on the use of a complex of metal indicators with metals. The principle of the method is based on the change of the metal complex with the metal indicator as a result of interaction with phosphate ions. Phosphate ions bind cations of metals such as zirconyl, since its phosphates have a very low solubility. The indicator released as a result of the destruction of the complex has a different color than the complex with a zirconyl cation. We experimentally tested the feasibility of using such metal indicators as chromazurol S, 8-oxyquinoline, arsenazo I, arsenazo III. The highest efficiency was demonstrated by the complex of chromazurol S with zirconyl ions, which is reflected in a clear change in color from purple to shades of crimson, red and orange for different phosphate concentrations. In the indicator system, we used a solution of chromazurol S with a concentration of 0.005 M and a solution of zirconyl nitrate with a concentration of 0.01 M. The ratio of the volumes of the solutions is 1:1. The proposed method of determination requires a significantly smaller amount of reagents than molybdate method.
- 10 September 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in WATER AND WATER PURIFICATION TECHNOLOGIES. SCIENTIFIC AND TECHNICAL NEWS
- Vol. 41 (1) , 3-7
Open AccessDETERMINATION OF PHOSPHATE CONTENT IN WATER USING ORGANIC CHROMOGENIC COMPOUNDS
Phosphorus compounds are introduced into natural waters in significant quantities as a result of anthropogenic activities. Agriculture and inadequate wastewater treatment are the main sources of phosphorus compounds. Increased levels of phosphorus compounds in water bodies lead to unbalanced eutrophication and significant changes in ecosystems. Therefore, monitoring phosphate levels is very important for maintaining the normal state of aquatic ecosystems. Spectrophotometry is one of the most widely used methods for measuring phosphate concentration. In the article, we reviewed existing spectrophotometric methods for determining the phosphate content in water and proposed a new method based on the use of a complex of metal indicators with metals. The principle of the method is based on the change of the metal complex with the metal indicator as a result of interaction with phosphate ions. Phosphate ions bind cations of metals such as zirconyl, since its phosphates have a very low solubility. The indicator released as a result of the destruction of the complex has a different color than the complex with a zirconyl cation. We experimentally tested the feasibility of using such metal indicators as chromazurol S, 8-oxyquinoline, arsenazo I, arsenazo III. The highest efficiency was demonstrated by the complex of chromazurol S with zirconyl ions, which is reflected in a clear change in color from purple to shades of crimson, red and orange for different phosphate concentrations. In the indicator system, we used a solution of chromazurol S with a concentration of 0.005 M and a solution of zirconyl nitrate with a concentration of 0.01 M. The ratio of the volumes of the solutions is 1:1. The proposed method of determination requires a significantly smaller amount of reagents than molybdate method.