Carl Hellesen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carl Hellesen has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Göran Ericsson
Uppsala University
3 shared publications - Jacob Eriksson
Uppsala University
3 shared publications - Christian Perez von Thun
Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland
2 shared publications Jet Contributors
EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB, UK
2 shared publications- Marco Tardocchi
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
2 shared publications - Maria Gatu Johnson
Massachusetts Institute of Technology
2 shared publications
Latest Publications
- Open Access
Strategic capacity expansion planning in hydro-dominated power systems: Insights from the Nordics
- 1 November 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 109, 712-719
Benchmark and demonstration of the CHD code for transient analysis of fast reactor systems
- 1 November 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 109, 712-719
Benchmark and demonstration of the CHD code for transient analysis of fast reactor systems
- 24 August 2016
- Published by IOP Publishing in Nuclear Fusion
- Vol. 56 (11) , 112021
Fusion product studies via fast ion D–D and D–3He fusion on JET
Dedicated fast ion D–D and D–3He fusion experiments were performed on JET with carbon wall (2008) and ITER-like wall (2014) for testing the upgraded neutron and energetic ion diagnostics of fusion products. Energy spectrum of D–D neutrons was the focus of the studies in pure deuterium plasmas. A significant broadening of the energy spectrum of neutrons born in D–D fast fusion was observed, and dependence of the maximum D and D–D neutron energies on plasma density was established. Diagnostics of charged products of aneutronic D–3He fusion reactions, 3.7 MeV alpha-particles similar to those in D–T fusion, and 14.6 MeV protons, were the focus of the studies in D–3He plasmas. Measurements of 16.4 MeV gamma-rays born in the weak secondary branch of D(3He, γ)5Li reaction were used for assessing D–3He fusion power. For achieving high yield of D–D and D–3He reactions at relatively low levels of input heating power, an acceleration of D beam up to the MeV energy range was used employing 3rd harmonic ( f = 3 f C D ) ICRH technique. These results were compared to the techniques of D beam injection into D–3He mixture, and 3He-minority ICRH in D plasmas.
- 24 August 2016
- Published by IOP Publishing in Nuclear Fusion
- Vol. 56 (11) , 112021
Fusion product studies via fast ion D–D and D–3He fusion on JET
Dedicated fast ion D–D and D–3He fusion experiments were performed on JET with carbon wall (2008) and ITER-like wall (2014) for testing the upgraded neutron and energetic ion diagnostics of fusion products. Energy spectrum of D–D neutrons was the focus of the studies in pure deuterium plasmas. A significant broadening of the energy spectrum of neutrons born in D–D fast fusion was observed, and dependence of the maximum D and D–D neutron energies on plasma density was established. Diagnostics of charged products of aneutronic D–3He fusion reactions, 3.7 MeV alpha-particles similar to those in D–T fusion, and 14.6 MeV protons, were the focus of the studies in D–3He plasmas. Measurements of 16.4 MeV gamma-rays born in the weak secondary branch of D(3He, γ)5Li reaction were used for assessing D–3He fusion power. For achieving high yield of D–D and D–3He reactions at relatively low levels of input heating power, an acceleration of D beam up to the MeV energy range was used employing 3rd harmonic ( f = 3 f C D ) ICRH technique. These results were compared to the techniques of D beam injection into D–3He mixture, and 3He-minority ICRH in D plasmas.
- Open Access
- 1 August 2016
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 94, 487-493
Neutron flux monitoring with in-vessel fission chambers to detect an inadvertent control rod withdrawal in a sodium-cooled fast reactor
- 1 August 2016
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 94, 487-493
Open AccessNeutron flux monitoring with in-vessel fission chambers to detect an inadvertent control rod withdrawal in a sodium-cooled fast reactor
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10E136
New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)
Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose “burning plasmas.” D–T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1–18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10E136
New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)
Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose “burning plasmas.” D–T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1–18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.
- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D324
Neutron spectroscopy as a fuel ion ratio diagnostic: Lessons from JET and prospects for ITER
The determination of the fuel ion ratio in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of . We use simplified but realistic Monte Carlo models of ITER to assess the possibility to use neutron emission spectroscopy (NES) for such measurements. We show that NES meets the requirements for ion temperatures and for . A crucial issue is the signal-to-background situation in the measurement of the weak 2.5 MeV emission from DD reactions in the presence of a background of scattered 14 MeV DT neutrons. Important experimental input and corroboration for this assessment are presented from the time-of-flight neutron spectrometer at JET where the presence of a strong component of backscattered neutrons is observed. Neutron emission components on ITER due to beam-thermal and tritium-tritium reactions can further enhance the prospects for NES.- 1 October 2010
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 81 (10) , 10D324
Neutron spectroscopy as a fuel ion ratio diagnostic: Lessons from JET and prospects for ITER
The determination of the fuel ion ratio in ITER is required at a precision of 20%, time resolution of 100 ms, spatial resolution of a/10, and over a range of . We use simplified but realistic Monte Carlo models of ITER to assess the possibility to use neutron emission spectroscopy (NES) for such measurements. We show that NES meets the requirements for ion temperatures and for . A crucial issue is the signal-to-background situation in the measurement of the weak 2.5 MeV emission from DD reactions in the presence of a background of scattered 14 MeV DT neutrons. Important experimental input and corroboration for this assessment are presented from the time-of-flight neutron spectrometer at JET where the presence of a strong component of backscattered neutrons is observed. Neutron emission components on ITER due to beam-thermal and tritium-tritium reactions can further enhance the prospects for NES.