Daniel C. Leslie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel C. Leslie has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Donald Elliot Ingber
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
7 shared publications - Anna Waterhouse
The University of Sydney Nano Institute
6 shared publications Michael Super
Wyss Institute for Biologically Inspired Engineering at Harvard University, 3 Blackfan Circle, Boston, Massachusetts 02115, United States
6 shared publicationsJames P. Landers
Department of Chemistry, University of Virginia, McCormick Rd, Charlottesville, VA, USA
5 shared publications- James P. Landers
Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
4 shared publications Marcel Utz
†Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
4 shared publications
Latest Publications
- 8 May 2019
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 108 (2) , 496-502
Tethered‐liquid omniphobic surface coating reduces surface thrombogenicity, delays clot formation and decreases clot strength ex vivo
Hemocompatible materials for extracorporeal life support (ECLS) technology are investigated to mitigate thrombotic complications associated with this therapy. A promising solution is an omniphobic bilayer coating, tethered liquid perfluorocarbon (TLP), which utilizes an immobilized tether to anchor a mobile, liquid surface lubricant that prevents adhesion of blood components to the substrate. In this study, we investigated the effects of TLP on real‐time clot formation using thromboelastography (TEG). TLP was applied to TEG cups, utilizing perfluorodecalin (PFD) or FluorLube63 as the liquid layer, and compared to uncoated cups. Human blood (n = 10) was added to cups; and TEG parameters (R, K, α‐angle, MA, LY30, LY60) and adherent thrombus weight were assessed. TLP decreased clot amplification (α‐angle), clot strength (MA), and adherent clot weight (p < .0001). These effects were greater with FluorLube63 versus PFD (α‐angle p < .0001; MA p = .0019; clot weight p < .0001). Reaction time (R) was longer in TLP‐coated cups versus control cups with liquid lubricant added (p = .0377). Percent fibrinolysis (LY30 and LY60) was greater in the TLP versus controls at LY30 (p < .0001), and in FluoroLube63 versus controls at LY60 (p = .0021). TLP significantly altered clot formation, exerting antithrombogenic effects. This reduction in surface thrombogenicity supports TLP as a candidate for improved biocompatibility of ECLS materials, pending further validation with exposure to shear stress.
- 8 May 2019
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 108 (2) , 496-502
Tethered‐liquid omniphobic surface coating reduces surface thrombogenicity, delays clot formation and decreases clot strength ex vivo
Hemocompatible materials for extracorporeal life support (ECLS) technology are investigated to mitigate thrombotic complications associated with this therapy. A promising solution is an omniphobic bilayer coating, tethered liquid perfluorocarbon (TLP), which utilizes an immobilized tether to anchor a mobile, liquid surface lubricant that prevents adhesion of blood components to the substrate. In this study, we investigated the effects of TLP on real‐time clot formation using thromboelastography (TEG). TLP was applied to TEG cups, utilizing perfluorodecalin (PFD) or FluorLube63 as the liquid layer, and compared to uncoated cups. Human blood (n = 10) was added to cups; and TEG parameters (R, K, α‐angle, MA, LY30, LY60) and adherent thrombus weight were assessed. TLP decreased clot amplification (α‐angle), clot strength (MA), and adherent clot weight (p < .0001). These effects were greater with FluorLube63 versus PFD (α‐angle p < .0001; MA p = .0019; clot weight p < .0001). Reaction time (R) was longer in TLP‐coated cups versus control cups with liquid lubricant added (p = .0377). Percent fibrinolysis (LY30 and LY60) was greater in the TLP versus controls at LY30 (p < .0001), and in FluoroLube63 versus controls at LY60 (p = .0021). TLP significantly altered clot formation, exerting antithrombogenic effects. This reduction in surface thrombogenicity supports TLP as a candidate for improved biocompatibility of ECLS materials, pending further validation with exposure to shear stress.
- 1 March 2019
- Published by Elsevier in Trends in Biotechnology
- Vol. 37 (3) , 268-280
Clinical Potential of Immobilized Liquid Interfaces: Perspectives on Biological Interactions
- 1 March 2019
- Published by Elsevier in Trends in Biotechnology
- Vol. 37 (3) , 268-280
Clinical Potential of Immobilized Liquid Interfaces: Perspectives on Biological Interactions
- 27 December 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 5 (2) , 420-424
Rapid Coating Process Generates Omniphobic Dentures in Minutes to Reduce C. albicans Biofouling
Localized infections caused by biofilm formation on dentures pose a serious health risk for patients, especially the elderly, as they can lead to complications such as pneumonia. Daily enzymatic denture cleaners do not fully prevent biofilm formation on dentures. Here we developed a rapid coating process to apply a liquid repellent surface to dentures in ∼5 min and demonstrated a significant 225-fold reduction of Candida albicans adhesion over 6 days, compared to uncoated dentures. This rapid coating process could be applied to dentures and other dental devices chair-side and allow the research community to quickly and easily generate ominphobic surfaces.
- 27 December 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 5 (2) , 420-424
Rapid Coating Process Generates Omniphobic Dentures in Minutes to Reduce C. albicans Biofouling
Localized infections caused by biofilm formation on dentures pose a serious health risk for patients, especially the elderly, as they can lead to complications such as pneumonia. Daily enzymatic denture cleaners do not fully prevent biofilm formation on dentures. Here we developed a rapid coating process to apply a liquid repellent surface to dentures in ∼5 min and demonstrated a significant 225-fold reduction of Candida albicans adhesion over 6 days, compared to uncoated dentures. This rapid coating process could be applied to dentures and other dental devices chair-side and allow the research community to quickly and easily generate ominphobic surfaces.
- 1 October 2017
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 154 (4) , 1364-1366
New anticoagulant coatings and hemostasis assessment tools to avoid complications with pediatric left ventricular assist devices
- 1 October 2017
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 154 (4) , 1364-1366
New anticoagulant coatings and hemostasis assessment tools to avoid complications with pediatric left ventricular assist devices
- Open Access
- 1 July 2016
- Published by Elsevier in EBioMedicine
- Vol. 9, 217-227
A Broad-Spectrum Infection Diagnostic that Detects Pathogen-Associated Molecular Patterns (PAMPs) in Whole Blood
- 1 July 2016
- Published by Elsevier in EBioMedicine
- Vol. 9, 217-227
Open AccessA Broad-Spectrum Infection Diagnostic that Detects Pathogen-Associated Molecular Patterns (PAMPs) in Whole Blood
- 1 October 2015
- Published by Elsevier in Biomaterials
- Vol. 67, 382-392
Improved treatment of systemic blood infections using antibiotics with extracorporeal opsonin hemoadsorption
- 1 October 2015
- Published by Elsevier in Biomaterials
- Vol. 67, 382-392
Improved treatment of systemic blood infections using antibiotics with extracorporeal opsonin hemoadsorption
- Top Cited Papers
- 20 February 2015
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 27 (5) , 1792-1800
Stability of Surface-Immobilized Lubricant Interfaces under Flow
- 20 February 2015
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 27 (5) , 1792-1800
Top Cited PapersStability of Surface-Immobilized Lubricant Interfaces under Flow
- 12 February 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (6) , 2008-2015
Investigation of the DNA target design parameters for effective hybridization-induced aggregation of particles for the sequence-specific detection of DNA
An investigation into target DNA characteristics for the label-free detection of ssDNAviahybridization-induced aggregation (HIA).
- 12 February 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (6) , 2008-2015
Investigation of the DNA target design parameters for effective hybridization-induced aggregation of particles for the sequence-specific detection of DNA
An investigation into target DNA characteristics for the label-free detection of ssDNAviahybridization-induced aggregation (HIA).
- Top Cited Papers
- 12 October 2014
- Published by Springer Nature in Nature Biotechnology
- Vol. 32 (11) , 1134-1140
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
A non-stick surface coating makes medical devices anti-thrombogenic and resistant to biofilm growth. Thrombosis and biofouling of extracorporeal circuits and indwelling medical devices cause significant morbidity and mortality worldwide. We apply a bioinspired, omniphobic coating to tubing and catheters and show that it completely repels blood and suppresses biofilm formation. The coating is a covalently tethered, flexible molecular layer of perfluorocarbon, which holds a thin liquid film of medical-grade perfluorocarbon on the surface. This coating prevents fibrin attachment, reduces platelet adhesion and activation, suppresses biofilm formation and is stable under blood flow in vitro. Surface-coated medical-grade tubing and catheters, assembled into arteriovenous shunts and implanted in pigs, remain patent for at least 8 h without anticoagulation. This surface-coating technology could reduce the use of anticoagulants in patients and help to prevent thrombotic occlusion and biofouling of medical devices.
- 12 October 2014
- Published by Springer Nature in Nature Biotechnology
- Vol. 32 (11) , 1134-1140
Top Cited PapersA bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
A non-stick surface coating makes medical devices anti-thrombogenic and resistant to biofilm growth. Thrombosis and biofouling of extracorporeal circuits and indwelling medical devices cause significant morbidity and mortality worldwide. We apply a bioinspired, omniphobic coating to tubing and catheters and show that it completely repels blood and suppresses biofilm formation. The coating is a covalently tethered, flexible molecular layer of perfluorocarbon, which holds a thin liquid film of medical-grade perfluorocarbon on the surface. This coating prevents fibrin attachment, reduces platelet adhesion and activation, suppresses biofilm formation and is stable under blood flow in vitro. Surface-coated medical-grade tubing and catheters, assembled into arteriovenous shunts and implanted in pigs, remain patent for at least 8 h without anticoagulation. This surface-coating technology could reduce the use of anticoagulants in patients and help to prevent thrombotic occlusion and biofouling of medical devices.
- 3 October 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (1) , 182-188
A microdevice for rapid optical detection of magnetically captured rare blood pathogens
Sepsis diagnosis requires development of methods to identify rare pathogen cells in small samples of human blood. Magnetic beads functionalized with pathogen-binding ligands have been used to rapidly isolate microbes from blood; however, it is commonly difficult to optically detect the captured species because the excess numbers of beads required for pathogen binding physically interfere with light transmission after they have been concentrated. Here we describe a microdevice that uses microfluidics combined with optimized magnetic field concentrators and magnetic beads coated with a generic blood opsonin to efficiently capture unknown blood pathogens and spread them into a thin layer suitable for automated optical detection. Using this device, we have been able to detect fungal pathogens in less than three hours after sample collection compared to days with current technology, and with an extremely high sensitivity (−1 of human blood).
- 3 October 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (1) , 182-188
A microdevice for rapid optical detection of magnetically captured rare blood pathogens
Sepsis diagnosis requires development of methods to identify rare pathogen cells in small samples of human blood. Magnetic beads functionalized with pathogen-binding ligands have been used to rapidly isolate microbes from blood; however, it is commonly difficult to optically detect the captured species because the excess numbers of beads required for pathogen binding physically interfere with light transmission after they have been concentrated. Here we describe a microdevice that uses microfluidics combined with optimized magnetic field concentrators and magnetic beads coated with a generic blood opsonin to efficiently capture unknown blood pathogens and spread them into a thin layer suitable for automated optical detection. Using this device, we have been able to detect fungal pathogens in less than three hours after sample collection compared to days with current technology, and with an extremely high sensitivity (−1 of human blood).