Liliana Fátima Bezerra Lira Pontes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liliana Fátima Bezerra Lira Pontes has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Layanny Samara da Silva Souza
Center of Natural and Exact Sciences, Department of Chemistry, Federal University of Paraíba, João Pessoa, Brazil
2 shared publications- Márcio José Coelho Pontes
Postgraduate Program in Chemistry, Federal University of Paraíba, Center for Exact and Nature Sciences, João Pessoa, Paraíba, Brazil
2 shared publications Vanessa Freire de França
Center of Natural and Exact Sciences, Department of Chemistry, Federal University of Paraíba, João Pessoa, Brazil
2 shared publicationsWillyan Araújo da Costa
Center of Natural and Exact Sciences, Department of Chemistry, Federal University of Paraíba, João Pessoa, Brazil
2 shared publications- Ada Vivianny Pereira Santos
Department of Chemistry, Federal University of Paraíba, João Pessoa, Brazil
1 shared publication Adrielly Silva Albuquerque de Andrade
Department of Biotechnology, Center of Biotechnology, Federal University of Paraíba, João Pessoa/Paraíba, Brazil
1 shared publication
Latest Publications
- 15 July 2025
- Published by Elsevier in Food Chemistry
- Vol. 492 (Pt 3) , 145475
A method for quantifying and discriminating the colour index of refined sugar using a portable NIR spectrometer
- 15 July 2025
- Published by Elsevier in Food Chemistry
- Vol. 492 (Pt 3) , 145475
A method for quantifying and discriminating the colour index of refined sugar using a portable NIR spectrometer
- 8 January 2024
- Published by Springer Nature in Brazilian Journal of Chemical Engineering
- Vol. 42 (1) , 391-400
Combination of deep eutectic solvent and diluted acid pretreatments for sugarcane bagasse fractionation
- 8 January 2024
- Published by Springer Nature in Brazilian Journal of Chemical Engineering
- Vol. 42 (1) , 391-400
Combination of deep eutectic solvent and diluted acid pretreatments for sugarcane bagasse fractionation
- 8 May 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (27) , 70701-70712
Physical–chemical and ecotoxic evaluation of different deep eutectic solvents for green analytical applications
The search for new analytical methods is a latent reality in the so-called green analytical chemistry area, which aims at correlating analytical demands to environmental issues. Among the approaches used, it is possible to highlight green solvents as substitutes to the dangerous and conventional organic solvents as the most prominent alternative for this purpose. In the last few years, the amount of research focused on the usage of deep eutectic solvents (DESs) has been growing as an alternative to these issues. Thus, this work aimed to investigate the main physical–chemical and ecotoxical properties of seven different DESs. The results showed that DESs’ evaluated properties are influenced by the chemical structure of their precursors, which may regulate DESs’ viscosity, superficial tension, and antagonistic action against vegetable tissues and microbial cells. The constatations pointed here introduce a new perspective about the conscious usage of DESs on a green analytical point of view.
- 8 May 2023
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 30 (27) , 70701-70712
Physical–chemical and ecotoxic evaluation of different deep eutectic solvents for green analytical applications
The search for new analytical methods is a latent reality in the so-called green analytical chemistry area, which aims at correlating analytical demands to environmental issues. Among the approaches used, it is possible to highlight green solvents as substitutes to the dangerous and conventional organic solvents as the most prominent alternative for this purpose. In the last few years, the amount of research focused on the usage of deep eutectic solvents (DESs) has been growing as an alternative to these issues. Thus, this work aimed to investigate the main physical–chemical and ecotoxical properties of seven different DESs. The results showed that DESs’ evaluated properties are influenced by the chemical structure of their precursors, which may regulate DESs’ viscosity, superficial tension, and antagonistic action against vegetable tissues and microbial cells. The constatations pointed here introduce a new perspective about the conscious usage of DESs on a green analytical point of view.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 15 (4) , 827-843
Flipped Classroom and Station Rotation Model: A Brief Review of Their Applications in Science Teaching
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 15 (4) , 827-843
Flipped Classroom and Station Rotation Model: A Brief Review of Their Applications in Science Teaching
- 26 April 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (21) , 3184-3190
Calibration transfer of flour NIR spectra between benchtop and portable instruments
This work reports on the use of different strategies of calibration transfer to determine crude protein and fiber properties in samples of functional flours analyzed with benchtop (primary) and portable (secondary) NIR instruments. For this purpose, methods of direct standardization (DS) and reverse standardization (RS) were used on a different number of transfer samples. Calibration models based on the following regression strategies were evaluated: partial least squares using a full spectrum (PLSfull spectrum); PLS with significant regression coefficients selected by the Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with previous selection of variables by the successive projection algorithm (MLR/SPA). The performance of calibration models was assessed according to Root Mean Square Error of Prediction (RMSEP) values obtained in a prediction subset measured on a secondary instrument before and after standardization procedures. Before standardization, all the calibration models presented high RMSEP values for the prediction samples measured on the secondary instrument to determine both crude protein and fibers. After the direct standardization, a considerable decrease of the RMSEP values was observed in the PLSfull spectrum and MLR/SPA calibration models developed for crude protein determination. For fiber determination, the lowest RMSEP value was obtained using the PLSfull spectrum model with RS, although no statistically significant difference was found between the RMSEP values obtained for PLS/JK and MLR/SPA models.
- 26 April 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (21) , 3184-3190
Calibration transfer of flour NIR spectra between benchtop and portable instruments
This work reports on the use of different strategies of calibration transfer to determine crude protein and fiber properties in samples of functional flours analyzed with benchtop (primary) and portable (secondary) NIR instruments. For this purpose, methods of direct standardization (DS) and reverse standardization (RS) were used on a different number of transfer samples. Calibration models based on the following regression strategies were evaluated: partial least squares using a full spectrum (PLSfull spectrum); PLS with significant regression coefficients selected by the Jack-Knife algorithm (PLS/JK) and multiple linear regression (MLR) with previous selection of variables by the successive projection algorithm (MLR/SPA). The performance of calibration models was assessed according to Root Mean Square Error of Prediction (RMSEP) values obtained in a prediction subset measured on a secondary instrument before and after standardization procedures. Before standardization, all the calibration models presented high RMSEP values for the prediction samples measured on the secondary instrument to determine both crude protein and fibers. After the direct standardization, a considerable decrease of the RMSEP values was observed in the PLSfull spectrum and MLR/SPA calibration models developed for crude protein determination. For fiber determination, the lowest RMSEP value was obtained using the PLSfull spectrum model with RS, although no statistically significant difference was found between the RMSEP values obtained for PLS/JK and MLR/SPA models.