Aydın DURMUŞ
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Aydın DURMUŞ has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hakan Karakaya
Batman Üniversitesi
4 shared publications - Ali Serkan Avcı
Batman Üniversitesi
2 shared publications - Adem Yilmaz
Batman Üniversitesi
1 shared publication - Aytaç Çeti̇nBaş
Antalya Milli Eğitim Müdürlüğü
1 shared publication - Emre Turgut
Department of Energy Systems Engineering, University of Firat, Elazig, Turkey
1 shared publication - Fevzi Gülçimen
Mechanical Engineering Department, Munzur University, Tunceli, Turkey
1 shared publication
Latest Publications
- 6 July 2023
- Published by International Journal of Innovative Engineering Applications in International Journal of Innovative Engineering Applications
- Vol. 7 (1) , 27-31
Güneş Bacasında Verim Arttırılmasının Deneysel Olarak İncelenmesi
Bu çalışma, güneş bacasının etkinliğinin arttırılması için iyileştirici düzenlemeler yapılarak deneysel olarak incelenmiştir. Deneysel çalışmada kullanılan güneş bacası daha önce Batman ilinde kurulan 12 m baca uzunluğuna ve 128 m2 kolektör alanına sahip bir prototiptir. Ölçümler için dört farklı coğrafi yönde eş zamanlı sıcaklık, hız ve radyasyon verileri alınarak sistemin ilk hali ile karşılaştırılmıştır. Öncelikle kolektör güneş ışınımı absorbe etmesi için zemini siyah renge boyanmıştır. Daha sonra sistemin gece saatlerinde çalışabilmesi için zemine sıcak su boruları eklenmiş ve türbin giriş hava hızının arttırılması için çelik plakalar ile 4 bölgeye ayrılmıştır. Elde edilen verileri göre kolektör cam yüzeyi altında ortalama sıcaklık artışının 17.4 %, türbin giriş sıcaklığının % 11.2 türbün giriş hızının % 9.94 ve sistem güç çıkışını % 9.4 oranında arttığı gözlemlenmiştir.
- 6 July 2023
- Published by International Journal of Innovative Engineering Applications in International Journal of Innovative Engineering Applications
- Vol. 7 (1) , 27-31
Güneş Bacasında Verim Arttırılmasının Deneysel Olarak İncelenmesi
Bu çalışma, güneş bacasının etkinliğinin arttırılması için iyileştirici düzenlemeler yapılarak deneysel olarak incelenmiştir. Deneysel çalışmada kullanılan güneş bacası daha önce Batman ilinde kurulan 12 m baca uzunluğuna ve 128 m2 kolektör alanına sahip bir prototiptir. Ölçümler için dört farklı coğrafi yönde eş zamanlı sıcaklık, hız ve radyasyon verileri alınarak sistemin ilk hali ile karşılaştırılmıştır. Öncelikle kolektör güneş ışınımı absorbe etmesi için zemini siyah renge boyanmıştır. Daha sonra sistemin gece saatlerinde çalışabilmesi için zemine sıcak su boruları eklenmiş ve türbin giriş hava hızının arttırılması için çelik plakalar ile 4 bölgeye ayrılmıştır. Elde edilen verileri göre kolektör cam yüzeyi altında ortalama sıcaklık artışının 17.4 %, türbin giriş sıcaklığının % 11.2 türbün giriş hızının % 9.94 ve sistem güç çıkışını % 9.4 oranında arttığı gözlemlenmiştir.
- Open Access
- 26 January 2023
- Published by INESEG Yayincilik in European Journal of Technic
- Vol. 13 (1) , 12-17
Efficiency Analysis in Solar Air Heaters with Attached Internal Fins
In this study, an original solar air collector model, those of flow environment was fixed with fins for three different angles at the flow channel's height, was designed. Fixing fins in the flow environment lengthens the flow channel since the fins prevent boundary layer formation in a flow cannel. Apart from this, enlarged surface effect exists along with the effects of the fins, the air temperature at the outlet rises. The effects of fixed fins,for 30°, 45° and 60° angles, on the efficiency of collector were investigated. The collectors were made as standard collectors sets with measurements 0.93x1.93 m2 the flow channels of which have been modified. With the help of results obtained from the experiments, efficiency, Nusselt number, Reynold number values were calculated; and they were compared to each other along with the literature. In the collectors designed for this study, it was observed that the heat transfer increased with the decrease of the fins angles.
- 26 January 2023
- Published by INESEG Yayincilik in European Journal of Technic
- Vol. 13 (1) , 12-17
Open AccessEfficiency Analysis in Solar Air Heaters with Attached Internal Fins
In this study, an original solar air collector model, those of flow environment was fixed with fins for three different angles at the flow channel's height, was designed. Fixing fins in the flow environment lengthens the flow channel since the fins prevent boundary layer formation in a flow cannel. Apart from this, enlarged surface effect exists along with the effects of the fins, the air temperature at the outlet rises. The effects of fixed fins,for 30°, 45° and 60° angles, on the efficiency of collector were investigated. The collectors were made as standard collectors sets with measurements 0.93x1.93 m2 the flow channels of which have been modified. With the help of results obtained from the experiments, efficiency, Nusselt number, Reynold number values were calculated; and they were compared to each other along with the literature. In the collectors designed for this study, it was observed that the heat transfer increased with the decrease of the fins angles.
- 30 September 2022
- Published by Firat Universitesi in Fırat Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 34 (2) , 647-655
Laminar Dönen Boru Akışında Isı Transferinin İncelenmesi
Bu çalışmada, silindirik borunun çeşitli hızlarda döndürülmesi ile akışkana verilen dönme etkisinin ısı transferi, sürtünme faktörü ve etkinlik değerleri üzerinde meydana getirdiği değişimler deneysel olarak araştırılmıştır. Deneyler Reynolds sayısının 500 ile 1800 değerleri arasında ve silindirdik borunun farklı devirlerde döndürülmesiyle gerçekleştirilmiştir. Yapılan deneyler sonucunda, dönme hızındaki artış ile Nusselt sayısı, sürtünme faktörü ve etkinlik değerlerinde artış olduğu görülmüştür. Ayrıca laminar akışta gerçekleştirilen akış gözleme deneyleri ile borunun dönme hızındaki artışın, akışkan üzerine yaptığı etkiler görüntülenmiştir. Bu görüntülerden; laminar akış karakteristiği olan çizgi şeklindeki doğrusal akışın, dönme hızındaki artış ile birlikte türbülanslı akış karakteristiği kazandığı görülmüştür. Elde edilen sonuçların literatürle uyum içinde olduğu sonucu elde edilmiştir.
- 30 September 2022
- Published by Firat Universitesi in Fırat Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 34 (2) , 647-655
Laminar Dönen Boru Akışında Isı Transferinin İncelenmesi
Bu çalışmada, silindirik borunun çeşitli hızlarda döndürülmesi ile akışkana verilen dönme etkisinin ısı transferi, sürtünme faktörü ve etkinlik değerleri üzerinde meydana getirdiği değişimler deneysel olarak araştırılmıştır. Deneyler Reynolds sayısının 500 ile 1800 değerleri arasında ve silindirdik borunun farklı devirlerde döndürülmesiyle gerçekleştirilmiştir. Yapılan deneyler sonucunda, dönme hızındaki artış ile Nusselt sayısı, sürtünme faktörü ve etkinlik değerlerinde artış olduğu görülmüştür. Ayrıca laminar akışta gerçekleştirilen akış gözleme deneyleri ile borunun dönme hızındaki artışın, akışkan üzerine yaptığı etkiler görüntülenmiştir. Bu görüntülerden; laminar akış karakteristiği olan çizgi şeklindeki doğrusal akışın, dönme hızındaki artış ile birlikte türbülanslı akış karakteristiği kazandığı görülmüştür. Elde edilen sonuçların literatürle uyum içinde olduğu sonucu elde edilmiştir.
- 8 April 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (4) , 11296-11314
Numerical and experimental investigation of solar chimney power plant system performance
A prototype of a solar chimney power plant was performed by modeling in this study. The performed prototype was experimentally confirmed. Temperature, velocity, and radiation values were measured to actualize the confirmation. Experimental data that were obtained to determine the performance of solar chimney whose prototype was actualized by the help of measured values were computationally analyzed. The geometry of a solar chimney in the analysis was bidimensionally (2D) drawn on an axis of symmetry. The numerical simulation was analyzed with computational fluid dynamics (CFD) method. Since analysis results show that there is turbulent flow in system (RNG), k-ɛ turbulence model was used. Continuity, momentum, and energy equations were applied to the solar chimney system via the finite volume method. Moreover, DO (discrete ordinates) model was inserted in analysis to evaluate the radiation effect in the collector area. In addition to all these, correlation results between SPSS 17 statistics program and data obtained were evaluated. Finally, with reference to the comparison between numerical and experimental results, data obtained and numerical data are close to each other; the prototype is applicable to the real systems.
- 8 April 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (4) , 11296-11314
Numerical and experimental investigation of solar chimney power plant system performance
A prototype of a solar chimney power plant was performed by modeling in this study. The performed prototype was experimentally confirmed. Temperature, velocity, and radiation values were measured to actualize the confirmation. Experimental data that were obtained to determine the performance of solar chimney whose prototype was actualized by the help of measured values were computationally analyzed. The geometry of a solar chimney in the analysis was bidimensionally (2D) drawn on an axis of symmetry. The numerical simulation was analyzed with computational fluid dynamics (CFD) method. Since analysis results show that there is turbulent flow in system (RNG), k-ɛ turbulence model was used. Continuity, momentum, and energy equations were applied to the solar chimney system via the finite volume method. Moreover, DO (discrete ordinates) model was inserted in analysis to evaluate the radiation effect in the collector area. In addition to all these, correlation results between SPSS 17 statistics program and data obtained were evaluated. Finally, with reference to the comparison between numerical and experimental results, data obtained and numerical data are close to each other; the prototype is applicable to the real systems.
- 17 September 2019
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 42 (11) , 1335-1358
Empirical calculation of the optimal tilt angle for solar collectors in northern hemisphere
Panel tilt angles (0°–90°) need to be in a proper position and location to get maximum productivity from solar energy. Values used in solar energy applications are generally computed by (global, diffuse, and direct) variation on horizontal surfaces calculated using isotropic sky and a mean albedo method. Being parallel to the available literature concerning such applications, this study focuses on the optimum solar panel angle. In this study, optimum solar panel angle value by months was determined for three sample provinces (Antalya, Kayseri, and Trabzon) first and North Hemisphere then. Capacity calculation of sample provinces was performed based on monthly, seasonal, and annual angle values and horizontal situation. Monthly and annual optimum angle values for Northern Hemisphere by 1° increase for between the latitudes of 1° N and 65° N. While the panel angle is at the highest level in autumn and winter (November-December-January and February) in annual process, the lowest angle is observed in spring and summer (May-June-July-August). Several different mathematical models have been developed for the sample provinces and Northern Hemisphere. While the variable of 12 different models that were developed for provinces is the Declination (δ) coefficient, the variable of 7 different models that were developed Northern Hemisphere is the latitude (Ø). Regional values in literature with estimation results of models were analyzed based on NASA and PVGIS data color scale. There was created a possibility of comparison by aligning all the optimum solar panel angle values of related location via a scale whose values vary by 1 and 10. Moreover, all the models were verified by statistical analysis methods. R2 (determination coefficient) in 19 different estimation equations is pretty close or equal to 1. However, the best among them is Eq. 32 (0.9979) for sample provinces and Eq. (33) (1) for the Northern Hemisphere; developed models are less-than-stellar. Other statistical data of these equations are MBE (−0.0616), RMSE (1.1176), t-sat (0.1830), Bias (1). For Eq. (32); MBE (1.96), RMSE (2.75), t-sat (8.13), MPE % (3.98), MAPE (5.87), SSRE (0.27), and RSE (0.06) for Eq. (33). The statistical analyzes indicate that all regression models are applicable in Turkey and Northern Hemisphere. Developed all correlations are recommended for academic and industrial users.
- 17 September 2019
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 42 (11) , 1335-1358
Empirical calculation of the optimal tilt angle for solar collectors in northern hemisphere
Panel tilt angles (0°–90°) need to be in a proper position and location to get maximum productivity from solar energy. Values used in solar energy applications are generally computed by (global, diffuse, and direct) variation on horizontal surfaces calculated using isotropic sky and a mean albedo method. Being parallel to the available literature concerning such applications, this study focuses on the optimum solar panel angle. In this study, optimum solar panel angle value by months was determined for three sample provinces (Antalya, Kayseri, and Trabzon) first and North Hemisphere then. Capacity calculation of sample provinces was performed based on monthly, seasonal, and annual angle values and horizontal situation. Monthly and annual optimum angle values for Northern Hemisphere by 1° increase for between the latitudes of 1° N and 65° N. While the panel angle is at the highest level in autumn and winter (November-December-January and February) in annual process, the lowest angle is observed in spring and summer (May-June-July-August). Several different mathematical models have been developed for the sample provinces and Northern Hemisphere. While the variable of 12 different models that were developed for provinces is the Declination (δ) coefficient, the variable of 7 different models that were developed Northern Hemisphere is the latitude (Ø). Regional values in literature with estimation results of models were analyzed based on NASA and PVGIS data color scale. There was created a possibility of comparison by aligning all the optimum solar panel angle values of related location via a scale whose values vary by 1 and 10. Moreover, all the models were verified by statistical analysis methods. R2 (determination coefficient) in 19 different estimation equations is pretty close or equal to 1. However, the best among them is Eq. 32 (0.9979) for sample provinces and Eq. (33) (1) for the Northern Hemisphere; developed models are less-than-stellar. Other statistical data of these equations are MBE (−0.0616), RMSE (1.1176), t-sat (0.1830), Bias (1). For Eq. (32); MBE (1.96), RMSE (2.75), t-sat (8.13), MPE % (3.98), MAPE (5.87), SSRE (0.27), and RSE (0.06) for Eq. (33). The statistical analyzes indicate that all regression models are applicable in Turkey and Northern Hemisphere. Developed all correlations are recommended for academic and industrial users.