    Performance of two plasma separation devices for HIV-1 viral load measurement in primary healthcare settings

    by Adolfo Vubil, Ana Flora Zicai, Nádia Sitoe, Carina Nhachigule, Paulino da Costa, Cacildo Magul, Bindiya Meggi, Sofia Viegas, Nédio Mabunda, Ilesh Jani

    Dried blood spot (DBS) may overestimate the viral RNA, mainly in patients with low viral load (VL), due to proviral DNA and intracellular RNA. The Burnett and HemaSpot provide integrated solutions for the collection, separation, and drying of plasma from whole blood. This study aims to evaluate the performance of both devices compared to plasma to identify antiretroviral therapy (ART) failure. The devices were separately evaluated in a cross-sectional design. Patients on ART were included for the studies (Burnett: 611, October 2019 to January 2020) and (HemaSpot: 620, November 2020 to April 2021). VL was tested using CAP/CTM96. The sensitivity and specificity of DBS, Burnett, and HemaSpot were determined, and plasma results were considered as a reference at a threshold of 1,000 copies/ml. For the Burnett study, 2,444 specimens, including plasma, DBS, venous Burnett (vBurnett), and capillary Burnett (cBurnett), were collected. Sensitivity of DBS, vBurnett, and cBurnett was 97.4%, 98.3%, and 97.5%, respectively, whereas specificity was 86.8% for DBS, 96.9% for vBurnett, and 93.9% for cBurnett. For the HemaSpot study, 1,860 specimens were collected, including plasma, DBS, and vHemaSpot. Sensitivity of DBS and vHemaSpot was 95.0% and 91.3%, respectively, whereas specificity was 86.9% for DBS and 94.5% for vHemaSpot. The misclassification rate was more prominent in DBS (4.8%) and HemaSpot (8.4%) but lower in vBurnett (2.0%) and cBurnett (3.2%). The Burnett showed better performance than DBS, whereas HemaSpot showed poorer performance than DBS. Nevertheless, both Burnett and HemaSpot have high rate of non-reportable results. In the current format, neither of the two devices is feasible for VL scale-up in resource-limited settings. IMPORTANCE: Burnett and HemaSpot are two novel technologies that allow whole blood collection and plasma separation and stabilization at room temperature without the need of additional equipment. Hence, these devices are potential alternatives to fresh plasma as a suitable specimen for viral load scale-up to monitor antiretroviral therapy in resource-limited settings


  • Open Access

    Molecular Epidemiology and Trends in HIV-1 Transmitted Drug Resistance in Mozambique 1999–2018

    by Nalia Ismael, Eduan Wilkinson, Isabel Mahumane, Hernane Gemusse, Jennifer Giandhari, Adilson Bauhofer, Adolfo Vubil, Pirolita Mambo, Lavanya Singh, Nédio Mabunda, et al.

    HIV drug resistance (HIVDR) can become a public health concern, especially in low- and middle-income countries where genotypic testing for people initiating antiretroviral therapy (ART) is not available. For first-line regimens to remain effective, levels of transmitted drug resistance (TDR) need to be monitored over time. To determine the temporal trends of TDR in Mozambique, a search for studies in PubMed and sequences in GenBank was performed. Only studies covering the pol region that described HIVDR and genetic diversity from treatment naïve patients were included. A dataset from seven published studies and one novel unpublished study conducted between 1999 and 2018 were included. The Calibrated Population Resistance tool (CPR) and REGA HIV-1 Subtyping Tool version 3 for sequences pooled by sampling year were used to determine resistance mutations and subtypes, respectively. The prevalence of HIVDR amongst treatment-naïve individuals increased over time, reaching 14.4% in 2018. The increase was most prominent for non-nucleoside reverse transcriptase inhibitors (NNRTIs), reaching 12.7% in 2018. Subtype C was predominant in all regions, but a higher genetic variability (19% non-subtype C) was observed in the north region of Mozambique. These findings confirm a higher diversity of HIV in the north of the country and an increased prevalence of NNRTI resistance among treatment naïve individuals over time.


  • Open Access

    Stability of HIV-1 Nucleic Acids in cobas Plasma Separation Card for Viral Load Measurement

    by Adolfo Vubil, Carina Nhachigule, Ana Flora Zicai, Bindiya Meggi, Paulino da Costa, Nédio Mabunda, Sofia Viegas, Nádia Sitoe, Ilesh Jani

    Objectives: Our study aimed to evaluate the stability of human immunodeficiency virus 1 (HIV-1) RNA on cobas plasma separation card (PSC) specimens for viral load (VL) testing after being exposed to varied temperatures and storage times. Methods: For this purpose, venous PSC specimens were collected and stored at 25ºC to 42ºC for a period of up to 28 days. Plasma VL at baseline was used as reference, against which PSC VL was compared at different time points. Results: From the 30 patients included in the study, 600 PSC and 30 fresh plasma specimens were obtained. Plasma VL at baseline was fewer than 1,000 copies/mL in 16 patients, and 99.4% of PSCs from these patients yielded nonquantifiable VL at all temperature ranges and time points. During the study period, minor variation of VL was observed in PSCs obtained from 13 patients with plasma VL fewer than 1,000 copies/mL at baseline. For the patient with plasma VL at 1,000 copies/mL, the PSC VL varied from undetectable to 1,670 copies/mL. Conclusions: Our results show minor variation of VL in PSC specimens in the study conditions. HIV RNA is stable in PSCs exposed to high temperatures for up to 28 days.


  • Open Access

    Accurate HIV viral load measurement in primary health care settings using the cobas® plasma separation card

    by Adolfo Vubil, Ana Flora Zicai, Nádia Sitoe, Carina Nhachigule, Bindiya Meggi, Osvaldo Loquiha, Sofia Viegas, Nédio Mabunda, Lesley Scott, Ilesh Jani

    Plasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, however, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas® Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas® PSC for VL testing at primary health care facilities in Mozambique. HIV-1 infected adults on ART were enrolled consecutively in two health facilities in Mozambique, between August 2018 and October 2018. Capillary and venous cobas® PSC, DBS and fresh plasma specimens were collected from each patient. All specimens were tested for VL using CAP/CTM v2.0. Sensitivity and specificity of viral load using DBS, capillary and venous PSC specimens were estimated. Viral load obtained in fresh plasma specimen was used as reference and a threshold of 1000 copies/ml was considered for the analyses. From the total 613 patients included for the study, 2444 specimens including DBS (613), plasma (613), venous cobas® PSC (609) and capillary cobas® PSC (609) were collected and 2407 results were obtained. Sensitivity and specificity of the VL using venous cobas®PSC specimen at 1000 copies/ml threshold were 99.8% and 98.1% respectively, whereas for capillary cobas® PSC sensitivity was 99.6% and specificity was 97.2%. For DBS VL, sensitivity was 96.9% and specificity was 81.8%. Misclassification rate was more prominent in DBS specimens (5.9%), but lower in venous and capillary cobas®PSC with a rate of 0.3% and 0.7% respectively. The cobas® PSC specimen has improved performance over DBS for more accurate VL testing aligned with plasma testing. The use of this specimen type can increase the rates of reliable VL results and this will improve the quality of VL monitoring of HIV-positive patients in low-income settings.


  • Open Access

    Viral load assay performs comparably to early infant diagnosis assay to diagnose infants with HIV in Mozambique: a prospective observational study

    by Adolfo Vubil, Carina Nhachigule, Osvaldo Loquiha, Bindiya Meggi, Nedio Mabunda, Timothy Bollinger, Jilian A Sacks, Ilesh Jani, Lara Vojnov

    Introduction: Viral load testing is essential to manage HIV disease, especially in infants and children. Early infant diagnosis (EID) is performed using nucleic‐acid testing in children under 18 months. Resource‐limited health systems face severe challenges to scale‐up both viral load and EID to unprecedented levels. Streamlining laboratory systems would be beneficial to improve access to quality testing and to increase efficiency of antiretroviral treatment programmes. We evaluated the performance of viral load testing to serve as an EID assay in children younger than 18 months.Methods: This study was an observational, prospective study, including children between one and 18 months of age who were born to HIV‐positive mothers in 134 health facilities in Maputo City and Maputo Province, Mozambique. Dried blood spot specimens from heel or toe pricks were collected between January and April 2018, processed using SPEX buffer for both assays, and tested for routine EID and viral load testing using the Roche CAP/CTM HIV‐1 Qualitative v2 and Roche CAP/CTM HIV‐1 Quantitative v2 assays respectively. The sensitivity, specificity and positive and negative predictive values were estimated using the EID results as the reference standard.Results: A total of 1021 infants were included in the study, of which 47% were female. Over 95% of mothers and children were on antiretroviral treatment or received antiretroviral prophylaxis respectively. The sensitivity and specificity of using the viral load assay to detect infection were 100% (95% CI: 96.2 to 100%) and 99.9% (95% CI: 99.4 to 100%). The positive and negative predictive values were 99.0% (95% CI: 94.3 to 100%) and 100% (95% CI: 99.6 to 100%). The McNemar’s test was 1.000 and Cohen’s kappa was 0.994.Conclusions: The comparable performance suggests that viral load assays can be used as an infant diagnostic assay. Infants with either low levels of viraemia or high cycle threshold values should be repeat tested to ensure the result is truly positive prior to treatment initiation, regardless of assay used. Viral load assays could replace traditional EID testing, substantially streamlining molecular laboratory services for children and lowering costs, with the additional advantage of providing baseline viral load results for antiretroviral treatment management.


  • Open Access

    External Quality Assessment Programme for Early Infant Diagnosis of HIV-1, Mozambique, 2011–2014

    by Nalia Ismael, Orvalho Augusto, Adolfo Vubil, Sofia O. Viegas, Fernanda Miambo, Patrina Chongo, Nédio Mabunda

    This study evaluated a National External Quality Scheme Program for early infant diagnosis of HIV. Fourteen laboratory technicians participated and nine testing panel cycles were sent between 2011 and 2014. The response rate was 100% for the first eight panels, and the number of technicians with a test score of 100% increased during the first three panels. Based on the evaluations of the technicians, the quality of testing for early infant diagnosis of HIV improved over time in the laboratories.


  • Open Access

    Evaluation of a High-Throughput Diagnostic System for Detection of HIV-1 in Dried Blood Spot Samples from Infants in Mozambique

    by Ilesh V. Jani, Jennifer Sabatier, Adolfo Vubil, Shambavi Subbarao, Dulce Bila, Amina de Sousa, Nédio Mabunda, Albert Garcia, Beth Skaggs, Dennis Ellenberger, et al.

    We performed a comparative analysis between Roche Amplicor HIV-1 DNA test and CAPTAQ assay for the detection of HIV in 830 dried blood spot (DBS) pediatric samples collected in Mozambique. Our results demonstrated no statistical difference between these assays. The CAPTAQ assay approached nearly 100% repeatability/accuracy. The increased throughput of testing with minimal operator interference in performing the CAPTAQ assay clearly demonstrated that this method is an improvement over the Roche Amplicor HIV-1 DNA test, version 1.5.