Guillermo Glez-De-Rivera

Guillermo Glez-De-Rivera

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guillermo Glez-De-Rivera has a total of 461 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Developing the Readout Electronics for a Custom 64 × 64 SPAD Array: From Single-Board Prototyping to FPGA Implementation Toward Stellar Intensity Interferometry

    by Álvaro Quintana, Guillermo González-De-Rivera, Sergio López-Buedo, Francisco Prada

    Single-photon avalanche diode (SPAD) arrays enable photon-starved applications, including time-of-flight imaging and stellar intensity interferometry. Their astronomical use remains scarcely explored, as the bottleneck is usually not detection but rather acquisition electronics for high-rate event streams. This work presents a modular, event-driven acquisition system for a 64 × 64 SPAD array within the La Palma Quantum Interferometer (LPQI) project, repurposing a LiDAR detector for multi-telescope interferometry. Two stages are used: a Raspberry Pi 5 with a custom board for validation, and an AMD Kria KR260 (Zynq UltraScale+ MPSoC) implementing the Address-Event Representation (AER) handshake in hardware at 100 MHz. The system streams AER events without per-event timestamping; sub-nanosecond time-tagging is left for a future stage based on the White Rabbit protocol. Optical bench tests confirmed spatial detection and localization of photons at a measured throughput of up to ≈124 keps under the highest illumination condition tested, and dark-count-rate characterization showed a rate below 10 Hz for most pixels (median: 1.68 Hz at 27.8 °C); raw per-pixel event-count maps further confirmed, for the first time on this array, the expected 2 × 2 spatial pattern of inter-pixel crosstalk from its shared-cathode pixel groups. The results demonstrate the feasibility of repurposing a LiDAR SPAD sensor and establish an acquisition-electronics baseline to aid the development of a timestamped, multi-telescope system for deployment on five telescopes of the Roque de los Muchachos Observatory.

  • Open Access

    Multiplex Portable Biosensor for Bacteria Detection

    by Karim Kaci, Estefanía Enebral-Romero, Emiliano Martínez-Periñán, Marina Garrido, Emilio M. Pérez, David López-Diego, Mónica Luna, Guillermo González-De-Rivera, Tania García-Mendiola, Encarnación Lorenzo

    An advanced, cost-effective, and portable DNA biosensor capable of detecting multiple bacteria simultaneously has been developed. The biosensor comprises a fast and inexpensive potentiostat that controls the applied potential to a screen-printed electrochemical array platform functionalized with MoS2 flakes and bacterial DNA probes. The current response obtained by à la carte thionine functionalized carbon nanodots (Ty-CDs) is monitored as an electrochemical indicator of the hybridization event. The design of the potentiostat prioritizes achieving an optimal signal-to-noise ratio and incorporates a user-friendly interface compatible with various devices, including computers, mobile phones, and tablets. The device is compact, lightweight, and manufactured at a low cost. The key components of the potentiostat include a data acquisition board capable of analyzing multiple samples simultaneously and a controller board. The results of this study confirm the ability of the multiplex portable biosensor to successfully detect specific bacterial DNA sequences, demonstrating its reliability and superior performance compared with a traditional, more complex, and laboratory-oriented potentiostat.


  • Open Access

    Multiplex Portable Biosensor for Bacteria Detection

    by Estefania Enebral- Romero, Karim Kaci, Emiliano Martinez-Periñan, Marina Garrido, Emilio Pérez, David López-Diego, Monica Luna, Guillermo González-De-Rivera, Tania García-Mendiola, Encarnación Lorenzo

    An advanced, cost-effective and portable DNA biosensor capable of detecting multiple bacteria simultaneously have been developed. The biosensor consists of a fast and inexpensive potentiostat that controls the applied potential to a screen-printed electrochemical array platform functionalized with MoS2 flakes and bacteria DNA probes, and monitors the current response obtained by the use of à la carte thionine functionalized carbon nanodots (Ty-CDs) as electrochemical indicator of the hybridization event. The design of the potentiostat prioritizes achieving an optimal signal-to-noise ratio and incorporates a user-friendly interface compatible with various devices such as computers, mobile phones and tablets. The device is compact, lightweight, and manufactured at a low cost. The key components of the potentiostat include a data acquisition board capable of analyzing multiple samples simultaneously and a controller board. The results obtained confirm the ability of the developed device to successfully detect specific bacteria DNA sequences, demonstrating the reliability and performance of the developed multiplexing portable biosensor with better sensibility than using a traditional, more complex and laboratory oriented potentiostat.

  • Top Cited Papers
    Open Access

    The Robotic Multiobject Focal Plane System of the Dark Energy Spectroscopic Instrument (DESI)

    by Joseph Harry Silber, Parker Fagrelius, Kevin Fanning, Michael Schubnell, Jessica Nicole Aguilar, Steven Ahlen, Jon Ameel, Otger Ballester, Charles Baltay, Chris Bebek, et al.

    A system of 5020 robotic fiber positioners was installed in 2019 on the Mayall Telescope, at Kitt Peak National Observatory. The robots automatically retarget their optical fibers every 10–20 minutes, each to a precision of several microns, with a reconfiguration time of fewer than 2 minutes. Over the next 5 yr, they will enable the newly constructed Dark Energy Spectroscopic Instrument (DESI) to measure the spectra of 35 million galaxies and quasars. DESI will produce the largest 3D map of the universe to date and measure the expansion history of the cosmos. In addition to the 5020 robotic positioners and optical fibers, DESI’s Focal Plane System includes six guide cameras, four wave front cameras, 123 fiducial point sources, and a metrology camera mounted at the primary mirror. The system also includes associated structural, thermal, and electrical systems. In all, it contains over 675,000 individual parts. We discuss the design, construction, quality control, and integration of all these components. We include a summary of the key requirements, the review and acceptance process, on-sky validations of requirements, and lessons learned for future multiobject, fiber-fed spectrographs.


  • Top Cited Papers
    Open Access

    Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument

    by DESI Collaboration, B. Abareshi, J. Aguilar, S. Ahlen, Shadab Alam, David M. Alexander, R. Alfarsy, L. Allen, C. Allende Prieto, O. Alves, et al.

    The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii] doublet at 8 × 10−17 erg s−1 cm−2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned.


  • Open Access

    Paving the way to point of care (POC) devices for SARS-CoV-2 detection

    by Karim Kaci, Rafael del Caño, Mónica Luna, Paula Milán-Rois, Milagros Castellanos, Melanie Abreu, Rafael Cantón, Juan Carlos Galán, Álvaro Somoza, Rodolfo Miranda, et al.


  • Open Access

    Multirobot Heterogeneous Control Considering Secondary Objectives

    by Julio F. Acosta, Guillermo González de Rivera, Víctor Hugo Andaluz, Javier Garrido

    Cooperative robotics has considered tasks that are executed frequently, maintaining the shape and orientation of robotic systems when they fulfill a common objective, without taking advantage of the redundancy that the robotic group could present. This paper presents a proposal for controlling a group of terrestrial robots with heterogeneous characteristics, considering primary and secondary tasks thus that the group complies with the following of a path while modifying its shape and orientation at any time. The development of the proposal is achieved through the use of controllers based on linear algebra, propounding a low computational cost and high scalability algorithm. Likewise, the stability of the controller is analyzed to know the required features that have to be met by the control constants, that is, the correct values. Finally, experimental results are shown with different configurations and heterogeneous robots, where the graphics corroborate the expected operation of the proposal.


  • Open Access

    Energy-Saver Mobile Manipulator Based on Numerical Methods

    by Julio Francisco Acosta Núñez, Víctor Hugo Andaluz Ortiz, Guillermo González-De-Rivera Peces, Javier Garrido Salas

    The work presents the kinematic and dynamic control of a mobile robotic manipulator system based on numerical methods. The proposal also presents the curvature analysis of a path not parameterized in time, for the optimization of energy consumption. The energy optimization considers two aspects: the velocity of execution in curves and the amount of movements generated by the robotic system. When a curve occurs on the predefined path, the execution velocity is analyzed throughout the system in a unified method to prevent skid effects from affecting the mobile manipulator, while the number of movements is limited by the redundancy presented by the robotic system to optimize energy use. The experimental results are shown to validate the mechanical and electronic construction of the system, the proposed controllers, and the saving of energy consumption.


  • Comparison of communication architectures for a fiber-positioning spectrograph

    by Sofia Martínez-García, Fernando Lopez-Colino, Javier Garrido, Guillermo Glez-De-Rivera, Justo Sanchez, Francisco Prada

    The communication architecture required to provide a bidirectional communication between a central command node and a full set of fiber positioners feeding a spectrograph is studied. Six different architectures have been analyzed in terms of communication time and power consumption. These architectures are the result of the combination of three different communication protocols: transmission control protocol/internet protocol (TCP/IP) over ethernet, interintegrated circuit (I2C), and controller area network. The design of communication architecture must prioritize between communication time and power consumption. The fastest architecture is the hybrid TCP/IP over ethernet-I2C. This architecture requires the least time to provide a full set of coordinates to every fiber positioner less than 50 ms. The most power efficient solution is the I2C—I2C with demultiplexers. This architecture solves a bidirectional communication between a central node and a full set of fiber positioners requiring only an addition of 27 mW.


  • Amperometric determination of hazelnut traces by means of Express PCR coupled to magnetic beads assembled on disposable DNA sensing scaffolds

    by Víctor Ruiz-Valdepeñas Montiel, Rebeca M. Torrente-Rodríguez, Guillermo González de Rivera, A. Julio Reviejo, Carmen Cuadrado, Rosario Linacero, Francisco J. Gallego, Susana Campuzano, José M. Pingarrón