Eric R. Henderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eric R. Henderson has a total of 307 co-authors. Here are the top co-authors by number of shared publications:
- Brian W. Pogue
Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire, United States
21 shared publications - Jonathan Thomas Elliott
Dartmouth Health, Department of Orthopaedics, Lebanon, New Hampshire, United States
19 shared publications - Kimberley S. Samkoe
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA
19 shared publications - Konstantinos Linos
Department of Pathology and Laboratory Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire
15 shared publications - Hira Shahzad Sardar
Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
14 shared publications - Jason R. Gunn
Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
14 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (10) , 1-17
Spatio-temporally modulated fluorescence imager for intraoperative nerve identification
SignificanceFluorescence-guided surgery (FGS) based on nerve-labeling agents has the potential to enhance nerve identification during various operational procedures including orthopedic, craniofacial, and otolaryngological surgeries that involve complex and delicate nerve structures. A major challenge in FGS is the adverse impact of strong ambient light, which interferes with weak fluorescence signals, especially at visible wavelengths. Currently, this issue is mitigated by dimming or turning off the operating room (OR) lights during the fluorescence imaging procedure. However, this causes substantial disruption to the surgical workflow and reduces the potential for clinical adoption of FGS technologies.AimIn this work, we develop a novel intraoperative fluorescence imager that is based on a spatio-temporal modulation (STM) approach to suppress interference from strong OR lights.ApproachThe STM technology employed a line-scan imaging scheme that encodes the fluorescence signal into a distinctive spatial frequency within a narrow time window. By applying spatial frequency demodulation and time-gating methods, the imager effectively extracted the fluorescence signals by rejecting temporally constant and spatially uniform background OR lights.ResultsThe performance of the imager in detecting nerve structures in realistic OR lighting conditions was validated during in vivo animal studies. Additional evaluation using ex vivo human nerve tissue specimens and perfused amputated human limbs further supported the clinical suitability and readiness.ConclusionsThis innovative imaging technology enables high-contrast fluorescence visualization of nerve tissue under standard OR lighting and represents a significant step toward practical clinical implementation of FGS for enhanced nerve identification.
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (10) , 1-17
Open AccessSpatio-temporally modulated fluorescence imager for intraoperative nerve identification
SignificanceFluorescence-guided surgery (FGS) based on nerve-labeling agents has the potential to enhance nerve identification during various operational procedures including orthopedic, craniofacial, and otolaryngological surgeries that involve complex and delicate nerve structures. A major challenge in FGS is the adverse impact of strong ambient light, which interferes with weak fluorescence signals, especially at visible wavelengths. Currently, this issue is mitigated by dimming or turning off the operating room (OR) lights during the fluorescence imaging procedure. However, this causes substantial disruption to the surgical workflow and reduces the potential for clinical adoption of FGS technologies.AimIn this work, we develop a novel intraoperative fluorescence imager that is based on a spatio-temporal modulation (STM) approach to suppress interference from strong OR lights.ApproachThe STM technology employed a line-scan imaging scheme that encodes the fluorescence signal into a distinctive spatial frequency within a narrow time window. By applying spatial frequency demodulation and time-gating methods, the imager effectively extracted the fluorescence signals by rejecting temporally constant and spatially uniform background OR lights.ResultsThe performance of the imager in detecting nerve structures in realistic OR lighting conditions was validated during in vivo animal studies. Additional evaluation using ex vivo human nerve tissue specimens and perfused amputated human limbs further supported the clinical suitability and readiness.ConclusionsThis innovative imaging technology enables high-contrast fluorescence visualization of nerve tissue under standard OR lighting and represents a significant step toward practical clinical implementation of FGS for enhanced nerve identification.
- Open Access
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec4197
Toward autonomous robotic-assisted and microrobotic surgery
Autonomous robotic-assisted surgery (RAS) has emerged as a promising objective in biomedical technology, further enhanced by miniaturization toward microrobotic-assisted surgery (μ-RAS). This reduction in scale promises minimally invasive, partially or fully automated surgical procedures, with the potential to reduce patient recovery times, lower medical costs, and enable previously unavailable procedural options. This perspective highlights the specific advances in RAS that potentially map to the microscale (μ-RAS), organized across five surgical domains: endovascular, endoluminal, laparoscopic, ophthalmic, and orthopedic. We examine both clinical demands and technological advances in surgical robotics and identify the key innovations required for progress across these surgical fields. Our contribution is distinct in combining the perspectives of both surgical experts and bioengineering innovators, outlining a roadmap for the advancement and eventual integration of autonomous RAS and μ-RAS into mainstream surgical practice.
- 3 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (27) , eaec4197
Open AccessToward autonomous robotic-assisted and microrobotic surgery
Autonomous robotic-assisted surgery (RAS) has emerged as a promising objective in biomedical technology, further enhanced by miniaturization toward microrobotic-assisted surgery (μ-RAS). This reduction in scale promises minimally invasive, partially or fully automated surgical procedures, with the potential to reduce patient recovery times, lower medical costs, and enable previously unavailable procedural options. This perspective highlights the specific advances in RAS that potentially map to the microscale (μ-RAS), organized across five surgical domains: endovascular, endoluminal, laparoscopic, ophthalmic, and orthopedic. We examine both clinical demands and technological advances in surgical robotics and identify the key innovations required for progress across these surgical fields. Our contribution is distinct in combining the perspectives of both surgical experts and bioengineering innovators, outlining a roadmap for the advancement and eventual integration of autonomous RAS and μ-RAS into mainstream surgical practice.
- Open Access
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Figure S3 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure correlating biological variance ratio (BVR) to contrast-to-variance ratio (CVR).
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Open AccessFigure S3 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure correlating biological variance ratio (BVR) to contrast-to-variance ratio (CVR).
- Open Access
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Figure S2 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure correlating biological variance ratio (BVR) to tumor to background ratio (TBR).
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Open AccessFigure S2 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure correlating biological variance ratio (BVR) to tumor to background ratio (TBR).
- Open Access
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Supplementary Methods from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental methods and materials for testing the binding of ABY-029 to EGFR in A431 cells.
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Methods from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental methods and materials for testing the binding of ABY-029 to EGFR in A431 cells.
- Open Access
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Supplementary Tables from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental tables: Table S1, S2, and S3.
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Tables from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental tables: Table S1, S2, and S3.
- Open Access
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Figure S1 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure demonstrating relationship of mean fluorescence intensity for normal tissues compared to tumor.
- 17 June 2026
- Published by American Association for Cancer Research (AACR)
Open AccessFigure S1 from First-in-Human Study of ABY-029, a Novel Fluorescent Peptide that Targets EGFR, Applied to Soft-Tissue Sarcomas
Supplemental figure demonstrating relationship of mean fluorescence intensity for normal tissues compared to tumor.
- 5 March 2026
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13832, 27
Implementation of a prospective, multi-center clinical study of dynamic contrast fluorescence imaging to diagnose necrotizing soft-tissue infection: challenges and lessons learned
Necrotizing soft-tissue infections (NSTIs) are rapidly progressive and highly lethal, with diagnostic uncertainty contributing to treatment delays and mortality rates approaching 30%. To address this challenge, a multi-center clinical trial has been initiated to evaluate dynamic contrast-enhanced fluorescence imaging (DCE-FI) with indocyanine green as a rapid diagnostic tool. This technology enables visualization of microvascular thrombi characteristic of NSTIs, distinguishing them from less severe infections. The trial engages seven tertiary centers within a collaborative NSTI study group. This presentation will focus on the execution and implementation of this complex, multi-institutional study, including processes for protocol harmonization, regulatory coordination, and standardized imaging workflows. A key element of implementation was the development of real-time, smartphone-accessible didactic materials to ensure consistent imaging technique, data acquisition, and troubleshooting across all participating sites. Emphasis will be placed on the strategies used to maintain study fidelity and ensure successful completion across centers, enabling validation of DCE-FI as a transformative diagnostic adjunct in NSTI care.
- 5 March 2026
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13832, 27
Implementation of a prospective, multi-center clinical study of dynamic contrast fluorescence imaging to diagnose necrotizing soft-tissue infection: challenges and lessons learned
Necrotizing soft-tissue infections (NSTIs) are rapidly progressive and highly lethal, with diagnostic uncertainty contributing to treatment delays and mortality rates approaching 30%. To address this challenge, a multi-center clinical trial has been initiated to evaluate dynamic contrast-enhanced fluorescence imaging (DCE-FI) with indocyanine green as a rapid diagnostic tool. This technology enables visualization of microvascular thrombi characteristic of NSTIs, distinguishing them from less severe infections. The trial engages seven tertiary centers within a collaborative NSTI study group. This presentation will focus on the execution and implementation of this complex, multi-institutional study, including processes for protocol harmonization, regulatory coordination, and standardized imaging workflows. A key element of implementation was the development of real-time, smartphone-accessible didactic materials to ensure consistent imaging technique, data acquisition, and troubleshooting across all participating sites. Emphasis will be placed on the strategies used to maintain study fidelity and ensure successful completion across centers, enabling validation of DCE-FI as a transformative diagnostic adjunct in NSTI care.
- Open Access
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (02) , 1-17
Evaluation of analytical models to estimate depth of fluorescence objects in biological media
SignificancePerforming a ratiometric analysis of the fluorescence signals noninvasively measured at two different wavelengths can provide depth estimates of subsurface inner structures in a simple and fast manner, allowing for real-time applications in clinical settings. This can be done using the initially proposed single-excitation–multiple-emission wavelengths approach or by implementing a modified multiple-excitation–single-emission approach; the latter being sometimes preferred due to the larger variation of tissue optical properties at shorter wavelengths. However, previous works validating this method with Monte Carlo (MC) simulations, experiments on tissue-mimicking phantoms, and in vivo measurements on small animal models have reported different degrees of accuracy.AimWe tested the influence of factors not generally accounted for in the analytical model used for data interpretation (e.g., tissue geometry and boundaries, inclusion size and shape, and spectral characteristics of the excitation source). To address these limitations, we developed an improved theoretical framework that explicitly accounts for these factors during data interpretation.ApproachModel validation was carried out with MC simulations and with phantom experiments using indocyanine green as the fluorescence contrast agent. The aimed tissue optical properties were those characteristic of the prostate in a wide range of wavelengths (from 550 to 900 nm).ResultsThe aforementioned factors have a strong influence when changing the original single-excitation–multiple-emission approach to a multiple-excitation–single-emission approach. Though this might make the latter a less preferable method, the low variability of the optical properties in the multiple emission approach (as it happens with prostate tissue) negatively impacts the depth reconstruction process.ConclusionsRegardless of the ratiometric strategy employed, accurate depth estimation requires that the theoretical model closely replicate the experimental conditions. Careful matching of model assumptions to the measurement environment is essential to achieve reliable data interpretation.
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (02) , 1-17
Open AccessEvaluation of analytical models to estimate depth of fluorescence objects in biological media
SignificancePerforming a ratiometric analysis of the fluorescence signals noninvasively measured at two different wavelengths can provide depth estimates of subsurface inner structures in a simple and fast manner, allowing for real-time applications in clinical settings. This can be done using the initially proposed single-excitation–multiple-emission wavelengths approach or by implementing a modified multiple-excitation–single-emission approach; the latter being sometimes preferred due to the larger variation of tissue optical properties at shorter wavelengths. However, previous works validating this method with Monte Carlo (MC) simulations, experiments on tissue-mimicking phantoms, and in vivo measurements on small animal models have reported different degrees of accuracy.AimWe tested the influence of factors not generally accounted for in the analytical model used for data interpretation (e.g., tissue geometry and boundaries, inclusion size and shape, and spectral characteristics of the excitation source). To address these limitations, we developed an improved theoretical framework that explicitly accounts for these factors during data interpretation.ApproachModel validation was carried out with MC simulations and with phantom experiments using indocyanine green as the fluorescence contrast agent. The aimed tissue optical properties were those characteristic of the prostate in a wide range of wavelengths (from 550 to 900 nm).ResultsThe aforementioned factors have a strong influence when changing the original single-excitation–multiple-emission approach to a multiple-excitation–single-emission approach. Though this might make the latter a less preferable method, the low variability of the optical properties in the multiple emission approach (as it happens with prostate tissue) negatively impacts the depth reconstruction process.ConclusionsRegardless of the ratiometric strategy employed, accurate depth estimation requires that the theoretical model closely replicate the experimental conditions. Careful matching of model assumptions to the measurement environment is essential to achieve reliable data interpretation.