ATAlex Thompson

Alex Thompson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alex Thompson has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Selective recording of physiologically evoked neural activity in a mixed autonomic nerve using a minimally invasive array

    by Sophie C. Payne, Peregrine B. Osborne, Alex Thompson, Calvin D. Eiber, Janet R. Keast, James B. Fallon

    Real-time closed-loop control of neuromodulation devices requires long-term monitoring of neural activity in the peripheral nervous system. Although many signal extraction methods exist, few are both clinically viable and designed for extracting small signals from fragile peripheral visceral nerves. Here, we report that our minimally invasive recording and analysis technology extracts low to negative signal to noise ratio (SNR) neural activity from a visceral nerve with a high degree of specificity for fiber type and class. Complex activity was recorded from the rat pelvic nerve that was physiologically evoked during controlled bladder filling and voiding, in an extensively characterized in vivo model that provided an excellent test bed to validate our technology. Urethane-anesthetized male rats (n = 12) were implanted with a four-electrode planar array and the bladder instrumented for continuous-flow cystometry, which measures urodynamic function by recording bladder pressure changes during constant infusion of saline. We demonstrated that differential bipolar recordings and cross-correlation analyses extracts afferent and efferent activity, and discriminated between subpopulations of fibers based on conduction velocity. Integrated Aδ afferent fiber activity correlated with bladder pressure during voiding (r2: 0.66 ± 0.06) and was not affected by activating nociceptive afferents with intravesical capsaicin (r2: 0.59 ± 0.14, P = 0.54, and n = 3). Collectively, these results demonstrate our minimally invasive recording and analysis technology is selective in extracting mixed neural activity with low/negative SNR. Furthermore, integrated afferent activity reliably correlates with bladder pressure and is a promising first step in developing closed-loop technology for bladder control.


  • Open Access

    Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities

    by Robert K Shepherd, Paul M Carter, Ashley N Dalrymple, Ya Lang Enke, Andrew K Wise, Trung Nguyen, James Firth, Alex Thompson, James B Fallon

    Objective. Established guidelines for safe levels of electrical stimulation for neural prostheses are based on a limited range of the stimulus parameters used clinically. Recent studies have reported particulate platinum (Pt) associated with long-term clinical use of these devices, highlighting the need for more carefully defined safety limits. We previously reported no adverse effects of Pt corrosion products in the cochleae of guinea pigs following 4 weeks of electrical stimulation using charge densities far greater than the published safe limits for cochlear implants. The present study examines the histopathological effects of Pt within the cochlea following continuous stimulation at a charge density well above the defined safe limits for periods up to 6 months. Approach. Six cats were bilaterally implanted with Pt electrode arrays and unilaterally stimulated using charge balanced current pulses at a charge density of 267 μC cm−2 phase−1 using a tripolar electrode configuration. Electrochemical measurements were made throughout the implant duration and evoked potentials recorded at the outset and on completion of the stimulation program. Cochleae were examined histologically for particulate Pt, tissue response, and auditory nerve survival; electrodes were examined for surface corrosion; and cochlea, brain, kidney, and liver tissue analysed for trace levels of Pt. Main results. Chronic stimulation resulted in both a significant increase in tissue response and particulate Pt within the tissue capsule surrounding the electrode array compared with implanted, unstimulated control cochleae. Importantly, there was no stimulus-induced loss of auditory neurons (ANs) or increase in evoked potential thresholds. Stimulated electrodes were significantly more corroded compared with unstimulated electrodes. Trace analysis revealed Pt in both stimulated and control cochleae although significantly greater levels were detected within stimulated cochleae. There was no evidence of Pt in brain or liver; however, trace levels of Pt were recorded in the kidneys of two animals. Finally, increased charge storage capacity and charge injection limit reflected the more extensive electrode corrosion associated with stimulated electrodes. Significance. Long-term electrical stimulation of Pt electrodes at a charge density well above existing safety limits and nearly an order of magnitude higher than levels used clinically, does not adversely affect the AN population or reduce neural function, despite a stimulus-induced tissue response and the accumulation of Pt corrosion product. The mechanism resulting in Pt within the unstimulated cochlea is unclear, while the level of Pt observed systemically following stimulation at these very high charge densities does not appear to be of clinical significance.


  • Chronic intracochlear electrical stimulation at high charge densities: reducing platinum dissolution

    by Robert K Shepherd, Paul M Carter, Ya Lang Enke, Alex Thompson, Brianna Flynn, Ella P Trang, Ashley N Dalrymple, James B Fallon

    Objective. Cochleae of long-term cochlear implant users have shown evidence of particulate platinum (Pt) corroded from the surface of Pt electrodes. The pathophysiological effect of Pt within the cochlea has not been extensively investigated. We previously evaluated the effects of Pt corrosion at high charge densities and reported negligible pathophysiological impact. The present study extends this work by examining techniques that may reduce Pt corrosion. Approach. Deafened guinea pigs were continuously stimulated for 28 d using biphasic current pulses at extreme charge densities using: (i) electrode shorting; (ii) electrode shorting with capacitive coupling (CC); or (iii) electrode shorting with alternating leading phase (AP). On completion of stimulation, cochleae were examined for corrosion product, tissue response, auditory nerve (AN) survival and trace levels of Pt; and electrodes examined for surface corrosion. Main results. Pt corrosion was evident at ≥200 μ C cm −2 phase −1 ; the amount dependent on charge density ( p < 0.01) and charge recovery technique ( p < 0.01); reduced corrosion was apparent using CC. Tissue response increased with charge density ( p < 0.007); cochleae stimulated at ≥200 μ C cm −2 phase −1 exhibited a vigorous response including a focal region of necrosis and macrophages. Notably, tissue response was not dependent on the charge recovery technique ( p = 0.56). Despite stimulation at high charge densities resulting in significant levels of Pt corrosion, there was no stimulus induced loss of ANs. Significance. Significant increases in tissue response and Pt corrosion were observed following stimulation at high charge densities. Charge recovery using CC, and to a lesser extent AP, reduced the amount of Pt corrosion but not the tissue response. Stimulation at change densities an order of magnitude higher than those used when programming cochlear implant recipients in the clinic, produced a vigorous tissue response and corrosion products without evidence of neural loss.


  • Infrared nerve stimulation: modelling of photon transport and heat conduction

    by Alexander C. Thompson, Scott A. Wade, Peter J. Cadusch, William G. A. Brown, Paul R. Stoddart


  • Optical fibers and sensors for biomedical applications: bend effects

    by S. A. Wade, A. C. Thompson, W. G. A. Brown, D. F. Robertson, P. R. Stoddart

    Optical fibers are finding increased usage in biomedical applications, during which the fibers are often subjected to bending. Bending optical fibers can affect transmission properties and increase the likelihood of failure. In this paper the bending of fibers is discussed in relation to biomedical and sensing applications.

  • Changes in spectral properties of fibre Bragg gratings owing to bending

    by S.A. Wade, D.F. Robertson, A.C. Thompson, P.R. Stoddart

    The effects of bending on the spectral characteristics of fibre Bragg gratings have been investigated at relatively small bend diameters for small form factor applications. Tests undertaken on Bragg gratings written in different types of singlemode optical fibre indicate that the fibre type influences the magnitude of observed changes. Shifts in the centre wavelength of similar to 0.35 nm have been measured for a low bend loss fibre when the bend diameter was reduced to 6 mm. In contrast, no consistent trend could be observed for Bragg gratings in standard SMF-28 optical fibre as a function of bend diameter, despite the higher losses exhibited in this case


  • Overview of recent analysis of the energetic particle observations recorded in Situ by the EPONA instrument on the Giotto Mission to Comet Halley

    by S.M.P. McKenna-Lawlor, P. Daly, E. Kirsch, F.M. Neubauer, D. O'Sullivan, A. Thompson, P.K. Wenzel