Rafael Cavalcante
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rafael Cavalcante has a total of 260 co-authors. Here are the top co-authors by number of shared publications:
Yoshinobu Onuma
31 shared publications- Erhan Tenekecioglu
Department of Cardiology, Bursa Yüksek İhtisas Training and Research Hospital, Bursa, Türkiye
25 shared publications Yohei Sotomi
25 shared publications- Patrick W. Serruys
University of Galway
19 shared publications Carlos Collet
16 shared publicationsHiroki Tateishi
Division of Cardiology - Department of Clinical science and Medicine - Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi - Japan
14 shared publications
Latest Publications
- Open Access
- 23 January 2026
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 21
Workflow-based Framework to Aid With High-Definition Intravascular Ultrasound-Optimised Coronary Stenting: Introducing IVUS 123 Essentials
Intravascular ultrasound (IVUS) has been in clinical use for over three decades. Despite evidence that supports the application of the technology from multiple registries, randomised trials and meta-analyses, adoption remains low. Potential barriers to the adoption of IVUS are a lack of understanding as to how to accurately interpret images and how to incorporate it into clinical workflow. To address this, this paper summarises evidence-based protocols for the application of IVUS during percutaneous coronary intervention (PCI) into an easily understood workflow. Standardisation of approaches and wider adoption of IVUS-optimised PCI should improve patient outcomes and PCI durability.
- 23 January 2026
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 21
Open AccessWorkflow-based Framework to Aid With High-Definition Intravascular Ultrasound-Optimised Coronary Stenting: Introducing IVUS 123 Essentials
Intravascular ultrasound (IVUS) has been in clinical use for over three decades. Despite evidence that supports the application of the technology from multiple registries, randomised trials and meta-analyses, adoption remains low. Potential barriers to the adoption of IVUS are a lack of understanding as to how to accurately interpret images and how to incorporate it into clinical workflow. To address this, this paper summarises evidence-based protocols for the application of IVUS during percutaneous coronary intervention (PCI) into an easily understood workflow. Standardisation of approaches and wider adoption of IVUS-optimised PCI should improve patient outcomes and PCI durability.
- Top Cited PapersOpen Access
- 24 April 2025
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 46 (26) , 2498-2519
Definitions and standardized endpoints for the use of drug-coated balloon in coronary artery disease: consensus document of the Drug Coated Balloon Academic Research Consortium
The Drug Coated Balloon Academic Research Consortium project originated from the lack of standardization and comparability between studies using drug-coated balloons in the treatment of obstructive coronary artery disease. This document is a collaborative effort between academic research organizations and percutaneous coronary intervention societies in Europe, the USA, and Asia. This consensus sought to standardize study designs and endpoints for clinical trials involving drug-coated balloons, including defining angiographic, intravascular, and non-invasive imaging methods for lesion assessment, alongside considerations for post-revascularization pharmaco-therapy. The concept of ‘blended therapy’, which advocates for combining device strategies, is also discussed. This paper delineates study types, endpoint definitions, follow-up protocols, and analytical approaches, aiming to provide consistency and guidance for interventional cardiologists and trialists.
- 24 April 2025
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 46 (26) , 2498-2519
Top Cited PapersOpen AccessDefinitions and standardized endpoints for the use of drug-coated balloon in coronary artery disease: consensus document of the Drug Coated Balloon Academic Research Consortium
The Drug Coated Balloon Academic Research Consortium project originated from the lack of standardization and comparability between studies using drug-coated balloons in the treatment of obstructive coronary artery disease. This document is a collaborative effort between academic research organizations and percutaneous coronary intervention societies in Europe, the USA, and Asia. This consensus sought to standardize study designs and endpoints for clinical trials involving drug-coated balloons, including defining angiographic, intravascular, and non-invasive imaging methods for lesion assessment, alongside considerations for post-revascularization pharmaco-therapy. The concept of ‘blended therapy’, which advocates for combining device strategies, is also discussed. This paper delineates study types, endpoint definitions, follow-up protocols, and analytical approaches, aiming to provide consistency and guidance for interventional cardiologists and trialists.
- 1 August 2018
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 14 (6) , 678-685
Quality difference of neointima following the implantation of everolimus-eluting bioresorbable scaffolds and metallic stents in patients with ST-elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in the TROFI II trial
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 August 2018
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 14 (6) , 678-685
Quality difference of neointima following the implantation of everolimus-eluting bioresorbable scaffolds and metallic stents in patients with ST-elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in the TROFI II trial
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- Open Access
- 1 January 2018
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 111 (2) , 193-202
The Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation
Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.
- 1 January 2018
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 111 (2) , 193-202
Open AccessThe Role of Quantitative Aortographic Assessment of Aortic Regurgitation by Videodensitometry in the Guidance of Transcatheter Aortic Valve Implantation
Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.
- Open Access
- 1 December 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (11) , 1327-1335
Difference in haemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: insights from a preclinical endothelial shear stress study
In silico studies have provided robust evidence that stent design affects local haemodynamic forces, which appear as a major determinant of clinical outcomes following stent implantation. However, the implications of different stent/scaffold configurations on local haemodynamic forces have not yet been investigated in vivo in a comparative fashion. The aim of this study was to compare the ESS distribution in two differently shaped scaffolds using OCT-based modelling. Eight healthy mini pigs were implanted with six Absorb everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS) and five Mirage sirolimus-eluting bioresorbable microfibre scaffolds (Mirage BRMS). Optical coherence tomography (OCT) was performed and strut protrusion was assessed post scaffold implantation. Following the reconstruction of coronary anatomy, blood flow simulation was performed and endothelial shear stress (ESS) was estimated on top of the struts and at luminal surface between the struts in each scaffold. The thicker struts in Absorb (152±140 μm) resulted in an increased protruded distance compared to Mirage (117±123 μm) (p=0.003). This had an effect on the local haemodynamic microenvironment. ESS at the top of the struts was higher in Absorb (1.69±1.20 Pa) than in Mirage (1.53±0.91 Pa) (p<0.001), but lower at inter-strut zones (0.60±0.51 Pa vs. 0.63±0.50 Pa; p<0.01) compared to Mirage. Both scaffold types revealed comparable percentages of vessel luminal surface exposed to recirculation. Absorb demonstrated higher shear stress on top of the struts compared to Mirage. However, in the inter-strut zones shear stress was higher in Mirage than in Absorb. Further research is required to examine the potential value of in vivo computational modelling in optimising scaffold configuration and clinical outcomes.
- 1 December 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (11) , 1327-1335
Open AccessDifference in haemodynamic microenvironment in vessels scaffolded with Absorb BVS and Mirage BRMS: insights from a preclinical endothelial shear stress study
In silico studies have provided robust evidence that stent design affects local haemodynamic forces, which appear as a major determinant of clinical outcomes following stent implantation. However, the implications of different stent/scaffold configurations on local haemodynamic forces have not yet been investigated in vivo in a comparative fashion. The aim of this study was to compare the ESS distribution in two differently shaped scaffolds using OCT-based modelling. Eight healthy mini pigs were implanted with six Absorb everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS) and five Mirage sirolimus-eluting bioresorbable microfibre scaffolds (Mirage BRMS). Optical coherence tomography (OCT) was performed and strut protrusion was assessed post scaffold implantation. Following the reconstruction of coronary anatomy, blood flow simulation was performed and endothelial shear stress (ESS) was estimated on top of the struts and at luminal surface between the struts in each scaffold. The thicker struts in Absorb (152±140 μm) resulted in an increased protruded distance compared to Mirage (117±123 μm) (p=0.003). This had an effect on the local haemodynamic microenvironment. ESS at the top of the struts was higher in Absorb (1.69±1.20 Pa) than in Mirage (1.53±0.91 Pa) (p<0.001), but lower at inter-strut zones (0.60±0.51 Pa vs. 0.63±0.50 Pa; p<0.01) compared to Mirage. Both scaffold types revealed comparable percentages of vessel luminal surface exposed to recirculation. Absorb demonstrated higher shear stress on top of the struts compared to Mirage. However, in the inter-strut zones shear stress was higher in Mirage than in Absorb. Further research is required to examine the potential value of in vivo computational modelling in optimising scaffold configuration and clinical outcomes.
- 28 November 2017
- Published by Elsevier in Atherosclerosis
- Vol. 269, 6-13
Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study
- 28 November 2017
- Published by Elsevier in Atherosclerosis
- Vol. 269, 6-13
Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study
- 1 May 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (1) , 115-123
Quantitative angiography methods for bifurcation lesions: a consensus statement update from the European Bifurcation Club
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 May 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (1) , 115-123
Quantitative angiography methods for bifurcation lesions: a consensus statement update from the European Bifurcation Club
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 May 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (1) , 60-68
The interaction of de novo and pre-existing aortic regurgitation after TAVI: insights from a new quantitative aortographic technique
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 May 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 13 (1) , 60-68
The interaction of de novo and pre-existing aortic regurgitation after TAVI: insights from a new quantitative aortographic technique
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 April 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 12 (18) , e2212-e2218
Pressure-mediated versus pharmacologic treatment of radial artery spasm during cardiac catheterisation: a randomised pilot study
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 April 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 12 (18) , e2212-e2218
Pressure-mediated versus pharmacologic treatment of radial artery spasm during cardiac catheterisation: a randomised pilot study
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 March 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 12 (16) , 2001-2008
Non-invasive Heart Team assessment of multivessel coronary disease with coronary computed tomography angiography based on SYNTAX score II treatment recommendations: design and rationale of the randomised SYNTAX III Revolution trial
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 March 2017
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 12 (16) , 2001-2008
Non-invasive Heart Team assessment of multivessel coronary disease with coronary computed tomography angiography based on SYNTAX score II treatment recommendations: design and rationale of the randomised SYNTAX III Revolution trial
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)