A. V. Ravi Teja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. V. Ravi Teja has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Pratik Kalkal
Department of Electrical Engineering, IIT Ropar, Rupnagar, India
6 shared publications - Ashwani Kumar Rana
Department of Electrical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
3 shared publications - Muddasani Satyanarayana
Department of Electrical Engineering, IIT Ropar, Ropar, India
2 shared publications - Saifullah Payami
Department of Electrical Engineering, IIT Ropar, Rupnagar, India
2 shared publications - Aaqib Ahmad
Department of Electrical Engineering, Indian Institute of Technology Ropar, Rupnagar, India
1 shared publication - Abdul Azeem
Department of Electrical Engineering, IIT Ropar, Rupnagar, India
1 shared publication
Latest Publications
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
Novel Graphical Method for Uncovering Multiple Harmonic Mitigation Solutions at Ultra-Low Switching in Multilevel Inverters
This article proposes a novel graphical technique for identifying several sets of switching angle solutions with the same fundamental to mitigate different harmonics in a cascaded H-bridge (CHB) multilevel inverter with ultra-low switching frequency at fixed dc input. This technique is then applied on a three-phase seven-level CHB inverter for mitigating 50 lower-order harmonics with the limitation of three switching angles each quarter cycle. This ensures that the switching frequency is the same as the fundamental frequency. Using this technique, it is demonstrated that in more than 45% region of the available range of modulation indices, with just fundamental switching frequency, a seven-level inverter can mitigate all harmonics from its output line voltage up to the 50th order within the 5% range according to the IEEE 519-2022 standard. Apart from this, more than 20% region also provides a total harmonic distortion below the 8% value. The results obtained from the proposed graphical analysis are verified in simulation using MATLAB/Simulink software as well as hardware using an FPGA-based experimental prototype developed in the laboratory. Typical results are provided with three, four, and five switching angles in seven-level, nine-level, and three-level multilevel inverters respectively to validate the findings.
- 3 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-11
Novel Graphical Method for Uncovering Multiple Harmonic Mitigation Solutions at Ultra-Low Switching in Multilevel Inverters
This article proposes a novel graphical technique for identifying several sets of switching angle solutions with the same fundamental to mitigate different harmonics in a cascaded H-bridge (CHB) multilevel inverter with ultra-low switching frequency at fixed dc input. This technique is then applied on a three-phase seven-level CHB inverter for mitigating 50 lower-order harmonics with the limitation of three switching angles each quarter cycle. This ensures that the switching frequency is the same as the fundamental frequency. Using this technique, it is demonstrated that in more than 45% region of the available range of modulation indices, with just fundamental switching frequency, a seven-level inverter can mitigate all harmonics from its output line voltage up to the 50th order within the 5% range according to the IEEE 519-2022 standard. Apart from this, more than 20% region also provides a total harmonic distortion below the 8% value. The results obtained from the proposed graphical analysis are verified in simulation using MATLAB/Simulink software as well as hardware using an FPGA-based experimental prototype developed in the laboratory. Typical results are provided with three, four, and five switching angles in seven-level, nine-level, and three-level multilevel inverters respectively to validate the findings.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 13394-13404
A Generalized Modular Battery Pack Topology With Active Cell Balancing Technique
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 13394-13404
A Generalized Modular Battery Pack Topology With Active Cell Balancing Technique
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6615-6624
The Negative Modulation Index: A Key for Augmenting Solutions in Selective Harmonic Elimination and Mitigation Strategies
This article explores the innovative application of the negative modulation index (NMI) as a means to broaden the range of viable options for selective harmonic elimination (SHE) and selective harmonic mitigation (SHM) strategies. Conventionally, the use of a positive modulation index has been standard practice to attain the required magnitudes and phases of fundamental components. However, the research discloses that integrating NMI, which induces phase inversion while preserving magnitude, unlocks additional solutions, particularly in areas previously considered intractable. A critical reassessment of the phase-reversal region is conducted, uncovering its untapped potential for unique solutions. Despite the phase inversion introduced by NMI, the article proposes a novel implementation strategy that retains the original phase. The validity of this approach is established through graphical analysis, simulations in MATLAB/Simulink, and practical implementation on an FPGA-based experimental prototype for two, five, and seven switching angles per quarter. A range of case studies are presented that demonstrate significant enhancements in the SHE and SHM techniques through the utilization of NMI, thereby marking a new phase in the progression of harmonic control methods.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6615-6624
The Negative Modulation Index: A Key for Augmenting Solutions in Selective Harmonic Elimination and Mitigation Strategies
This article explores the innovative application of the negative modulation index (NMI) as a means to broaden the range of viable options for selective harmonic elimination (SHE) and selective harmonic mitigation (SHM) strategies. Conventionally, the use of a positive modulation index has been standard practice to attain the required magnitudes and phases of fundamental components. However, the research discloses that integrating NMI, which induces phase inversion while preserving magnitude, unlocks additional solutions, particularly in areas previously considered intractable. A critical reassessment of the phase-reversal region is conducted, uncovering its untapped potential for unique solutions. Despite the phase inversion introduced by NMI, the article proposes a novel implementation strategy that retains the original phase. The validity of this approach is established through graphical analysis, simulations in MATLAB/Simulink, and practical implementation on an FPGA-based experimental prototype for two, five, and seven switching angles per quarter. A range of case studies are presented that demonstrate significant enhancements in the SHE and SHM techniques through the utilization of NMI, thereby marking a new phase in the progression of harmonic control methods.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 492-501
A Single-Phase Integrated Power Charger Considering High-Frequency Behavior for Two Motor Drives Fed Electric Vehicles
This article introduces a fully integrated power charging (IPC) system designed for multi-motor electric vehicles (EVs). The multi-motor drive system, known for its superior acceleration and power capabilities, demands efficient and high-power charging solutions. The high power charging capability is achieved by utilizing both motor and inverter modules as an IPC, which is an inherent feature of multi-motor drive system. In the proposed IPC system both traction inverter and machine winding is utilized without any modification or reconfiguration in the power circuit. The article also delves into the high-frequency behaviour of machine inductance variation during IPC operation, which is critical for understanding winding behaviour at the switching frequency. The proposed system is validated through MATLAB/Simulink and a laboratory prototype across various power levels. Efficiency and power quality are assessed by monitoring input power factor and total harmonic distortion, aligning the system with IEEE 519-2022 standards. The proposed system is characterised by notable features, such as the absence of additional hardware requirements and compatibility with a single-phase 230 V, 50-60 Hz power outlet. The results prove the viability and reliability of the proposed IPC operation with the two-motor drivetrain system.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 492-501
A Single-Phase Integrated Power Charger Considering High-Frequency Behavior for Two Motor Drives Fed Electric Vehicles
This article introduces a fully integrated power charging (IPC) system designed for multi-motor electric vehicles (EVs). The multi-motor drive system, known for its superior acceleration and power capabilities, demands efficient and high-power charging solutions. The high power charging capability is achieved by utilizing both motor and inverter modules as an IPC, which is an inherent feature of multi-motor drive system. In the proposed IPC system both traction inverter and machine winding is utilized without any modification or reconfiguration in the power circuit. The article also delves into the high-frequency behaviour of machine inductance variation during IPC operation, which is critical for understanding winding behaviour at the switching frequency. The proposed system is validated through MATLAB/Simulink and a laboratory prototype across various power levels. Efficiency and power quality are assessed by monitoring input power factor and total harmonic distortion, aligning the system with IEEE 519-2022 standards. The proposed system is characterised by notable features, such as the absence of additional hardware requirements and compatibility with a single-phase 230 V, 50-60 Hz power outlet. The results prove the viability and reliability of the proposed IPC operation with the two-motor drivetrain system.
- 6 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 38-48
A Novel Selective Harmonic Mitigation PWM Technique With THD Minimization Using Second-Order Sliding Modes
This article proposes a novel selective harmonic mitigation technique based on higher order sliding-mode control. The method aims to reduce total harmonic distortion (THD) while mitigating multiple harmonics as necessary according to existing standards, such as IEEE 519-2022. Unlike selective harmonic elimination (SHE), which can only eliminate a fixed number of harmonics, the proposed method can accommodate $\boldsymbol{(m-1)}$ or more harmonics corresponding to $\boldsymbol {m}$ switching angles per quarter wave. The proposed methodology constrains the number of switching angles similar to SHE but achieves a lower THD and meets the IEEE 519-2022 requirements by alleviating multiple harmonics simultaneously. Complete details of the proposed algorithm are provided for a general case with $\boldsymbol {m}$ switching angles. Simulations in MATLAB/Simulink and experiments on a field-programmable gate array (FPGA) prototype validate the technique for $\boldsymbol{m=5}$ switching angles. Various test cases demonstrate the ability to mitigate specific harmonics while minimizing THD. Notably, the proposed SHM technique could mitigate up to four additional lower order harmonics above SHE with just five switching angles and two levels.
- 6 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 38-48
A Novel Selective Harmonic Mitigation PWM Technique With THD Minimization Using Second-Order Sliding Modes
This article proposes a novel selective harmonic mitigation technique based on higher order sliding-mode control. The method aims to reduce total harmonic distortion (THD) while mitigating multiple harmonics as necessary according to existing standards, such as IEEE 519-2022. Unlike selective harmonic elimination (SHE), which can only eliminate a fixed number of harmonics, the proposed method can accommodate $\boldsymbol{(m-1)}$ or more harmonics corresponding to $\boldsymbol {m}$ switching angles per quarter wave. The proposed methodology constrains the number of switching angles similar to SHE but achieves a lower THD and meets the IEEE 519-2022 requirements by alleviating multiple harmonics simultaneously. Complete details of the proposed algorithm are provided for a general case with $\boldsymbol {m}$ switching angles. Simulations in MATLAB/Simulink and experiments on a field-programmable gate array (FPGA) prototype validate the technique for $\boldsymbol{m=5}$ switching angles. Various test cases demonstrate the ability to mitigate specific harmonics while minimizing THD. Notably, the proposed SHM technique could mitigate up to four additional lower order harmonics above SHE with just five switching angles and two levels.
- 22 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (3) , 3052-3062
A Novel Graphical Technique for Multiple Harmonic Mitigation in a Two-Level Inverter With Only Two Switching Angles
This paper introduces a novel graphical technique for selective harmonic mitigation (SHM), substantiated by experimental data. This approach identifies maximum modulation indices for different harmonics while adhering to a constraint of two switchings per quarter cycle. The study demonstrates the effectiveness of the technique in mitigating harmonics within this range and optimizes harmonic suppression using variable DC voltages. The research uncovers multiple solution regions, addresses concerns at higher harmonics, and reveals an infinite solution space for selective harmonic mitigation. In particular, the approach achieves a 10% SHM bandwidth under a 5% IEEE 519-2022 standard limit and defines operating zones for enhanced management. The study also covers individual and cluster harmonic mitigation, highlighting the versatile application. The proposed graphical technique solves nonlinear SHM equations with inequalities and provides all possible solutions at every modulation index for single or multiple harmonic mitigations. The proposed technique is experimentally verified using an FPGA-based hardware prototype developed in the laboratory, and the results are presented. It is shown that up to seven harmonics can be simultaneously mitigated at certain modulation indices with only two switchings per quarter.
- 22 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (3) , 3052-3062
A Novel Graphical Technique for Multiple Harmonic Mitigation in a Two-Level Inverter With Only Two Switching Angles
This paper introduces a novel graphical technique for selective harmonic mitigation (SHM), substantiated by experimental data. This approach identifies maximum modulation indices for different harmonics while adhering to a constraint of two switchings per quarter cycle. The study demonstrates the effectiveness of the technique in mitigating harmonics within this range and optimizes harmonic suppression using variable DC voltages. The research uncovers multiple solution regions, addresses concerns at higher harmonics, and reveals an infinite solution space for selective harmonic mitigation. In particular, the approach achieves a 10% SHM bandwidth under a 5% IEEE 519-2022 standard limit and defines operating zones for enhanced management. The study also covers individual and cluster harmonic mitigation, highlighting the versatile application. The proposed graphical technique solves nonlinear SHM equations with inequalities and provides all possible solutions at every modulation index for single or multiple harmonic mitigations. The proposed technique is experimentally verified using an FPGA-based hardware prototype developed in the laboratory, and the results are presented. It is shown that up to seven harmonics can be simultaneously mitigated at certain modulation indices with only two switchings per quarter.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 631-640
Selective Harmonic Elimination PWM Technique Based on Higher Order Sliding Modes: Generalized Formulation
This paper pioneers a novel selective harmonic elimination (SHE) technique employing second-order sliding mode control. Unlike conventional methods, the proposed method leverages second-order sliding mode control to tackle the nonlinear equations of SHE, yielding smooth switching angles devoid of chattering. Theoretical analysis, including detailed derivations of controller parameters ensuring convergence, is presented. The algorithm has minimal computational burden, making it both simple to implement and robust in achieving convergence for any given modulation index. Simulation results, conducted in MATLAB/Simulink, and corresponding hardware outcomes from an FPGA-based experimental prototype in the laboratory validate the efficacy of the proposed algorithm. The proposed algorithm achieves the computation of switching angles in under 1.5 μs for a configuration involving five switchings per quarter.
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (1) , 631-640
Selective Harmonic Elimination PWM Technique Based on Higher Order Sliding Modes: Generalized Formulation
This paper pioneers a novel selective harmonic elimination (SHE) technique employing second-order sliding mode control. Unlike conventional methods, the proposed method leverages second-order sliding mode control to tackle the nonlinear equations of SHE, yielding smooth switching angles devoid of chattering. Theoretical analysis, including detailed derivations of controller parameters ensuring convergence, is presented. The algorithm has minimal computational burden, making it both simple to implement and robust in achieving convergence for any given modulation index. Simulation results, conducted in MATLAB/Simulink, and corresponding hardware outcomes from an FPGA-based experimental prototype in the laboratory validate the efficacy of the proposed algorithm. The proposed algorithm achieves the computation of switching angles in under 1.5 μs for a configuration involving five switchings per quarter.
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (4) , 1244-1254
Orthogonal Signal-Based Single-Phase FLL With Minimum Computational Overhead for Adverse Grid Conditions
In this paper, a frequency locked loop (FLL) is proposed for distorted single phase grid systems. The proposed algorithm estimates the grid phase and frequency angle with minimal errors by using the orthogonal signal of Harmonic Flag-Modified second-order generalized integrator (HF-MoSOGI) and digital estimator stage. The proposed method achieves these estimates independently without using trigonometric and division operations. The implementation of the proposed FLL is straightforward and has minimum computational overhead. The proposed algorithm, along with the detailed procedure for hardware implementation, is explained in this paper. The simulation and hardware results are presented at various grid adversities to verify the proposed algorithm's improved dynamic response and effectiveness under steady grid disturbances(harmonics and dc offset). The Proposed FLL is also used to implement the single-phase grid-tied inverter using hysteresis current control, and the results in simulation and hardware are reported.
- 26 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (4) , 1244-1254
Orthogonal Signal-Based Single-Phase FLL With Minimum Computational Overhead for Adverse Grid Conditions
In this paper, a frequency locked loop (FLL) is proposed for distorted single phase grid systems. The proposed algorithm estimates the grid phase and frequency angle with minimal errors by using the orthogonal signal of Harmonic Flag-Modified second-order generalized integrator (HF-MoSOGI) and digital estimator stage. The proposed method achieves these estimates independently without using trigonometric and division operations. The implementation of the proposed FLL is straightforward and has minimum computational overhead. The proposed algorithm, along with the detailed procedure for hardware implementation, is explained in this paper. The simulation and hardware results are presented at various grid adversities to verify the proposed algorithm's improved dynamic response and effectiveness under steady grid disturbances(harmonics and dc offset). The Proposed FLL is also used to implement the single-phase grid-tied inverter using hysteresis current control, and the results in simulation and hardware are reported.
- 6 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Digital Frequency Locked Loop With Minimum Computation Overhead for Heavily Distorted Single-Phase Grid Systems
Grid-connected converters require grid frequency and phase information for controlling the power injections into the grid. This information is achieved by a phase-locked loop (PLL) or frequency-locked loop (FLL) algorithms. The accuracy, reliability, and ease of implementation of the PLL/FLL algorithms in all grid conditions dictate the performance of the grid-connected converters. This article proposes a digital FLL for single-phase grid-connected systems. The proposed FLL tracks the frequency accurately, even in heavily distorted grid conditions. It uses a second-order generalized integrator (SOGI) as a pre-filter and a digital counter, based on the zero-crossing detection (ZCD) logic for estimating the grid frequency and phase angle. It does not require complex filters and tuning of multiple parameters. The implementation of the proposed FLL is simple and has less computational overhead. The ability of the proposed FLL to track the frequency and phase under various steady-state (dc-offset and harmonics) and transient (voltage sag, frequency drift, and phase jump) grid disturbances is tested in simulation using MATLAB/SIMULINK, and the results are reported. The experimental validation is done using a field programmable gate array (FPGA) controller in the laboratory. The proposed algorithm is able to track the estimates within 1.2 cycles of the grid voltage when tested under a heavy-distorted grid having 26.4% total harmonic distortion (THD). The measurement uncertainties and results of single-phase grid-connected inverter (GCI) using the proposed FLL are also presented.
- 6 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
A Digital Frequency Locked Loop With Minimum Computation Overhead for Heavily Distorted Single-Phase Grid Systems
Grid-connected converters require grid frequency and phase information for controlling the power injections into the grid. This information is achieved by a phase-locked loop (PLL) or frequency-locked loop (FLL) algorithms. The accuracy, reliability, and ease of implementation of the PLL/FLL algorithms in all grid conditions dictate the performance of the grid-connected converters. This article proposes a digital FLL for single-phase grid-connected systems. The proposed FLL tracks the frequency accurately, even in heavily distorted grid conditions. It uses a second-order generalized integrator (SOGI) as a pre-filter and a digital counter, based on the zero-crossing detection (ZCD) logic for estimating the grid frequency and phase angle. It does not require complex filters and tuning of multiple parameters. The implementation of the proposed FLL is simple and has less computational overhead. The ability of the proposed FLL to track the frequency and phase under various steady-state (dc-offset and harmonics) and transient (voltage sag, frequency drift, and phase jump) grid disturbances is tested in simulation using MATLAB/SIMULINK, and the results are reported. The experimental validation is done using a field programmable gate array (FPGA) controller in the laboratory. The proposed algorithm is able to track the estimates within 1.2 cycles of the grid voltage when tested under a heavy-distorted grid having 26.4% total harmonic distortion (THD). The measurement uncertainties and results of single-phase grid-connected inverter (GCI) using the proposed FLL are also presented.
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3896-3906
A Fault-Tolerant Power Converter With Multi-Switch Fault Diagnosis and Repair Capability for 4-Phase 8/6 SRM Drives
In this article, a modular fault-tolerant power converter for 8/6 four-phase switched reluctance motor (SRM) drives is presented. The proposed converter can work for both open-circuit (OC) and short-circuit (SC) fault conditions in the power semiconductor switches. A semiconductor switch module and a relay circuit are used for achieving the fault tolerance feature. The proposed converter is modular and provides independent fault-tolerant control for all phases. It also uses a minimum number of switches when compared with other fault-tolerant converter topologies. The proposed converter is tested for a fault in single as well as multiple phases using MATLAB/Simulink software and is validated experimentally on a 0.6 hp 8/6 SRM using an FPGA-based hardware setup developed in the laboratory. Detailed results are presented and compared with existing fault-tolerant converter topologies. A fault repair time of 2 ms has been achieved for both open and SC faults.
- 21 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3896-3906
A Fault-Tolerant Power Converter With Multi-Switch Fault Diagnosis and Repair Capability for 4-Phase 8/6 SRM Drives
In this article, a modular fault-tolerant power converter for 8/6 four-phase switched reluctance motor (SRM) drives is presented. The proposed converter can work for both open-circuit (OC) and short-circuit (SC) fault conditions in the power semiconductor switches. A semiconductor switch module and a relay circuit are used for achieving the fault tolerance feature. The proposed converter is modular and provides independent fault-tolerant control for all phases. It also uses a minimum number of switches when compared with other fault-tolerant converter topologies. The proposed converter is tested for a fault in single as well as multiple phases using MATLAB/Simulink software and is validated experimentally on a 0.6 hp 8/6 SRM using an FPGA-based hardware setup developed in the laboratory. Detailed results are presented and compared with existing fault-tolerant converter topologies. A fault repair time of 2 ms has been achieved for both open and SC faults.