Shane Johnson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shane Johnson has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Haihua Ou
UM-SJTU Joint Institute, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai 200240, China
8 shared publicationsZeeshan Qaiser
Department of Disaster Mitigation for Structures (DDMS), College of Civil Engineering, Tongji University, Shanghai, China
7 shared publications- Zeeshan Qaiser
Tongji University College of Civil Engineering Shanghai 200092 , China
6 shared publications Liping Kang
5 shared publications- Tanzeel Ur Rehman
UM-SJTU Joint Institute, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai 200240, China
4 shared publications Fatemeh Farhadi
3 shared publications
Latest Publications
- 3 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 332
Large-stroke quasi-zero stiffness actuators for robust passive force regulation
- 3 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 332
Large-stroke quasi-zero stiffness actuators for robust passive force regulation
- 3 June 2025
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 214
Iterative optimization to enhance effective compliance for design of large stroke constant torque mechanisms
- 3 June 2025
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 214
Iterative optimization to enhance effective compliance for design of large stroke constant torque mechanisms
- 5 May 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 19 (3)
A Semi-Active Dynamic Rapid Evaluate and Adjust Device for Prescribing Custom Foot Orthoses
Traditional custom foot orthoses (CFO) prescription methods often suffer from lengthy processing times, material waste due to refabrication, inconsistent performance due to inaccurate foot alignment, and inadequate consideration of soft tissue impedance. To address these issues, this study proposes a novel framework for CFO prescription that incorporates adjustable devices, dynamic testing, and subject feedback into the design cycle, thereby reducing delivery time. These shortcomings adversely affect the treatment of critical conditions such as foot ulcerations from diabetes, plantar fasciitis, foot deformity, and Achilles tendonitis. The Arch Height Evaluate and Adjust Device (AHEAD), designed for dynamic testing with the human-in-the-loop, was used to assess the performance of varying orthoses arch heights in different subjects. Plantar pressure measurements during gait and subjective feedback were utilized to determine optimal arch heights. Among ten subjects, the mean increase in medial midfoot peak pressure between the maximum comfortable orthoses arch height and the base profile was 37.57(±22.39) kPa, with an acceptable orthoses arch height range of 3.90(±1.26) mm. This framework offers a rapid, quantitative assessment of the relationship between orthotic design variables and dynamic performance, significantly reducing the time required for CFO prescription.
- 5 May 2025
- Published by ASME International in Journal of Medical Devices
- Vol. 19 (3)
A Semi-Active Dynamic Rapid Evaluate and Adjust Device for Prescribing Custom Foot Orthoses
Traditional custom foot orthoses (CFO) prescription methods often suffer from lengthy processing times, material waste due to refabrication, inconsistent performance due to inaccurate foot alignment, and inadequate consideration of soft tissue impedance. To address these issues, this study proposes a novel framework for CFO prescription that incorporates adjustable devices, dynamic testing, and subject feedback into the design cycle, thereby reducing delivery time. These shortcomings adversely affect the treatment of critical conditions such as foot ulcerations from diabetes, plantar fasciitis, foot deformity, and Achilles tendonitis. The Arch Height Evaluate and Adjust Device (AHEAD), designed for dynamic testing with the human-in-the-loop, was used to assess the performance of varying orthoses arch heights in different subjects. Plantar pressure measurements during gait and subjective feedback were utilized to determine optimal arch heights. Among ten subjects, the mean increase in medial midfoot peak pressure between the maximum comfortable orthoses arch height and the base profile was 37.57(±22.39) kPa, with an acceptable orthoses arch height range of 3.90(±1.26) mm. This framework offers a rapid, quantitative assessment of the relationship between orthotic design variables and dynamic performance, significantly reducing the time required for CFO prescription.
- 4 December 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 205
Achieving high-quality and large-stroke constant torque by axial force release
- 4 December 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 205
Achieving high-quality and large-stroke constant torque by axial force release
- 27 November 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 205
Order-of-magnitude increased range of constant force adjustment via section optimization
- 27 November 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 205
Order-of-magnitude increased range of constant force adjustment via section optimization
- 8 May 2024
- Published by Springer Nature in Journal of Intelligent Manufacturing
- Vol. 36 (5) , 3097-3109
Variability-enhanced knowledge-based engineering (VEN) for reconfigurable molds
- 8 May 2024
- Published by Springer Nature in Journal of Intelligent Manufacturing
- Vol. 36 (5) , 3097-3109
Variability-enhanced knowledge-based engineering (VEN) for reconfigurable molds
- 7 February 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 195
Design optimization and validation of compliant bidirectional constant force mechanisms
- 7 February 2024
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 195
Design optimization and validation of compliant bidirectional constant force mechanisms
- 22 December 2023
- Published by Wiley in Journal of Mechanical Design
- Vol. 146 (7) , 1-7
A Design Framework for Semi-Active Structural Controlled Adjustable Constant Force Mechanisms
Semi-active adjustable constant force mechanisms (ACFMs) are an emerging alternative in applications where energy-efficient control of constant force environments is required. However, there is a lack of design strategies in the literature for semi-active ACFMs. This study addresses this gap by presenting a design strategy for ACFMs that semi-actively tunes the constant force by structural control. A design framework is presented, which consists of an optimization of a high slenderness large stroke constant force mechanism (CFM) followed by a parametric study on adjusting constant force through slenderness reduction by repositioning the boundary condition location. The design framework was able to change constant force ranging from two to four times with a stroke of 11–26% of the mechanism footprint. A selected design with a larger force magnitude was fabricated and experimentally tested, demonstrating a change in constant force of 2.01 times, which is comparable to that of active control designs and improved compactness, i.e., stroke of 11% of the footprint of the mechanism. In conclusion, the proposed ACFM design framework maximizes the initial CFM stroke and achieves constant force tuning by changing beam slenderness, resulting in compact and efficient ACFM designs.
- 22 December 2023
- Published by Wiley in Journal of Mechanical Design
- Vol. 146 (7) , 1-7
A Design Framework for Semi-Active Structural Controlled Adjustable Constant Force Mechanisms
Semi-active adjustable constant force mechanisms (ACFMs) are an emerging alternative in applications where energy-efficient control of constant force environments is required. However, there is a lack of design strategies in the literature for semi-active ACFMs. This study addresses this gap by presenting a design strategy for ACFMs that semi-actively tunes the constant force by structural control. A design framework is presented, which consists of an optimization of a high slenderness large stroke constant force mechanism (CFM) followed by a parametric study on adjusting constant force through slenderness reduction by repositioning the boundary condition location. The design framework was able to change constant force ranging from two to four times with a stroke of 11–26% of the mechanism footprint. A selected design with a larger force magnitude was fabricated and experimentally tested, demonstrating a change in constant force of 2.01 times, which is comparable to that of active control designs and improved compactness, i.e., stroke of 11% of the footprint of the mechanism. In conclusion, the proposed ACFM design framework maximizes the initial CFM stroke and achieves constant force tuning by changing beam slenderness, resulting in compact and efficient ACFM designs.
- 22 December 2023
- Published by Wiley in Journal of Mechanical Design
- Vol. 146 (6) , 1-13
Boosting Energy Return Using 3D Printed Midsoles Designed With Compliant Constant Force Mechanisms
The enhancement of midsole compressive energy return is associated with improved running economy. Traditional midsole materials such as ethylene vinyl acetate (EVA), thermoplastic polyurethane (TPU), and polyether block amide (PEBA) foams typically exhibit hardening force–displacement characteristics. On the other hand, a midsole with softening properties, which can be achieved through compliant constant force mechanisms (CFMs), can provide significant benefits in terms of energy storage and return. This study presents the development of such a midsole, incorporating 3D printed TPU CFM designs derived through structural optimization. The mechanical properties under cyclic loading were evaluated and compared with those of commercially available running shoes with state-of-the-art PEBA foam midsoles, specifically the Nike ZoomX Vaporfly Next% 2 (NVP). Our custom midsole demonstrated promising mechanical performance. At similar deformation levels, the new design increased energy storage by 58.1% and energy return by 47.0%, while reducing the peak compressive force by 24.3%. As per our understanding, this is the first study to prove that the inclusion of CFMs in the structural design of 3D printed midsoles can significantly enhance energy return.
- 22 December 2023
- Published by Wiley in Journal of Mechanical Design
- Vol. 146 (6) , 1-13
Boosting Energy Return Using 3D Printed Midsoles Designed With Compliant Constant Force Mechanisms
The enhancement of midsole compressive energy return is associated with improved running economy. Traditional midsole materials such as ethylene vinyl acetate (EVA), thermoplastic polyurethane (TPU), and polyether block amide (PEBA) foams typically exhibit hardening force–displacement characteristics. On the other hand, a midsole with softening properties, which can be achieved through compliant constant force mechanisms (CFMs), can provide significant benefits in terms of energy storage and return. This study presents the development of such a midsole, incorporating 3D printed TPU CFM designs derived through structural optimization. The mechanical properties under cyclic loading were evaluated and compared with those of commercially available running shoes with state-of-the-art PEBA foam midsoles, specifically the Nike ZoomX Vaporfly Next% 2 (NVP). Our custom midsole demonstrated promising mechanical performance. At similar deformation levels, the new design increased energy storage by 58.1% and energy return by 47.0%, while reducing the peak compressive force by 24.3%. As per our understanding, this is the first study to prove that the inclusion of CFMs in the structural design of 3D printed midsoles can significantly enhance energy return.
- 4 July 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 127 (9-10) , 4903-4914
Structural and winding sequence optimization of coreless filament wound composite lattice structures
- 4 July 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 127 (9-10) , 4903-4914
Structural and winding sequence optimization of coreless filament wound composite lattice structures