HSHang Song

Hang Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hang Song has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microwave Breast Imaging Using Rotational Bistatic Impulse Radar for the Detection of Breast Cancer: Protocol for a Prospective Diagnostic Study

    by Shinsuke Sasada, Norio Masumoto, Hang Song, Akiko Emi, Takayuki Kadoya, Koji Arihiro, Takamaro Kikkawa, Morihito Okada

    Background: Mammography is the standard examination for breast cancer screening; however, it is associated with pain and exposure to ionizing radiation. Microwave breast imaging is a less invasive method for breast cancer surveillance. A bistatic impulse radar–based breast cancer detector has recently been developed. Objective: This study aims to present a protocol for evaluating the diagnostic accuracy of the novel microwave breast imaging device. Methods: This is a prospective diagnostic study. A total of 120 participants were recruited before treatment administration and divided into 2 cohorts: 100 patients diagnosed with breast cancer and 20 participants with benign breast tumors. The detector will be directly placed on each breast, while the participant is in supine position, without a coupling medium. Confocal images will be created based on the analyzed data, and the presence of breast tumors will be assessed. The primary endpoint will be the diagnostic accuracy, sensitivity, and specificity of the detector for breast cancer and benign tumors. The secondary endpoint will be the safety and detectability of each molecular subtype of breast cancer. For an exploratory endpoint, the influence of breast density and tumor size on tumor detection will be investigated. Results: Recruitment began in November 2018 and was completed by March 2020. We anticipate the preliminary results to be available by summer 2021. Conclusions: This study will provide insights on the diagnostic accuracy of microwave breast imaging using a rotational bistatic impulse radar. The collected data will improve the diagnostic algorithm of microwave imaging and lead to enhanced device performance. Trial Registration: Japan Registry of Clinical Trials jRCTs062180005; https://jrct.niph.go.jp/en-latest-detail/jRCTs062180005 International Registered Report Identifier (IRRID): DERR1-10.2196/17524


  • CMOS Gaussian Monocycle Pulse Transceiver for Radar-Based Microwave Imaging

    by Takamaro Kikkawa, Yoshihiro Masui, Akihiro Toya, Hiroyuki Ito, Takuichi Hirano, Tomoaki Maeda, Masahiro Ono, Yoshitaka Murasaka, Toshifumi Imamura, Tsuyoshi Matsumaru, et al.

    A single-chip Gaussian monocycle pulse (GMP) transceiver was developed for radar-based microwave imaging by the use of 65-nm complementary metal oxide semiconductor (CMOS) technology. A transmitter (TX) generates GMP signals, whose pulse widths and -3 dB bandwidths are 192 ps and 5.9 GHz, respectively. A 102.4 GS/s equivalent time sampling receiver (RX) performs the minimum jitter, input referred noise, signal-to-nose-ratio (SNR), signal-to-noise and distortion ratio (SNDR) effective number of bits (ENOB) of 0.58 ps, 0.24 mVrms, 28.4 dB, 26.6 dB and 4.1 bits, respectively. The SNR for the bandwidth of 3.6 GHz is 36.3 dB. The power dissipations of transmitter and receiver circuits are 19.79 mW and 48.87 mW, respectively. The GMP transceiver module can differentiate two phantom targets with the size of 1 cm and the spacing of 1 cm by confocal imaging.


  • A Two-Stage Rotational Surface Clutter Suppression Method for Microwave Breast Imaging With Multistatic Impulse-Radar Detector

    by Hang Song, Shinsuke Sasada, Norio Masumoto, Takayuki Kadoya, Morihito Okada, Koji Arihiro, Xia Xiao, Takamaro Kikkawa

    Radar-based microwave imaging is a promising technique for multiple medical applications such as breast health monitoring, breast cancer detection, ablation monitoring, and chemotherapy monitoring. In our previous work, a hand-held multistatic CMOS impulse-radar detector was developed. It was designed to be placed directly on the patient in supine position without a coupling medium. In the radar-based microwave breast imaging, the surface clutters, which are generated from skin reflection, imperfect contacts and antenna coupling, deteriorate the imaging quality. This paper proposes a two-stage rotational (TSR) clutter suppression method for the multistatic rotational configuration of the radar-detector. It consists of a signal selection stage and an adaptive filtering stage. The novelty of the proposed method is that a prior constraint using L2 regularization is introduced to facilitate the filtering. Meanwhile, the antenna and channel variations are considered in the signal selection. The performance of the proposed method is verified in experiments with different surface conditions and patient trial. The results demonstrated that the proposed method is effective in suppressing the surface clutters and improving the image quality.


  • Open Access

    Microwave Breast Imaging Using Rotational Bistatic Impulse Radar for the Detection of Breast Cancer: Protocol for a Prospective Diagnostic Study (Preprint)

    by Shinsuke Sasada, Norio Masumoto, Hang Song, Akiko Emi, Takayuki Kadoya, Koji Arihiro, Takamaro Kikkawa, Morihito Okada

    BACKGROUND Mammography is the standard examination for breast cancer screening; however, it is associated with pain and exposure to ionizing radiation. Microwave breast imaging is a less invasive method for breast cancer surveillance. A bistatic impulse radar–based breast cancer detector has recently been developed. OBJECTIVE This study aims to present a protocol for evaluating the diagnostic accuracy of the novel microwave breast imaging device. METHODS This is a prospective diagnostic study. A total of 120 participants were recruited before treatment administration and divided into 2 cohorts: 100 patients diagnosed with breast cancer and 20 participants with benign breast tumors. The detector will be directly placed on each breast, while the participant is in supine position, without a coupling medium. Confocal images will be created based on the analyzed data, and the presence of breast tumors will be assessed. The primary endpoint will be the diagnostic accuracy, sensitivity, and specificity of the detector for breast cancer and benign tumors. The secondary endpoint will be the safety and detectability of each molecular subtype of breast cancer. For an exploratory endpoint, the influence of breast density and tumor size on tumor detection will be investigated. RESULTS Recruitment began in November 2018 and was completed by March 2020. We anticipate the preliminary results to be available by summer 2021. CONCLUSIONS This study will provide insights on the diagnostic accuracy of microwave breast imaging using a rotational bistatic impulse radar. The collected data will improve the diagnostic algorithm of microwave imaging and lead to enhanced device performance. CLINICALTRIAL Japan Registry of Clinical Trials jRCTs062180005; https://jrct.niph.go.jp/en-latest-detail/jRCTs062180005 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/17524

  • Detectability of Breast Tumors in Excised Breast Tissues of Total Mastectomy by IR-UWB-Radar-Based Breast Cancer Detector

    by Hang Song, Shinsuke Sasada, Norio Masumoto, Takayuki Kadoya, Noriyuki Shiroma, Makoto Orita, Koji Arihiro, Morihito Okada, Takamaro Kikkawa

    The objective of this study is to investigate the detectability of breast tumors having various histological types in excised breast tissues of total mastectomy. The tumor images measured by a portable impulse-radio-ultra-wideband (IR-UWB)-radar-based breast cancer detector are compared with both pathological images and images of dedicated breast positron emission tomography (DbPET). It is found that the detector can detect invasive-ductal-carcinomas (IDC) and extensive intra-ductal component (EIC) in the dense breast. The density of the breast has correlation to the effective permittivity derived from the reconstructed confocal images. The results show that the IR-UWB-radar-based breast cancer detector has a potential as a portable modality for early-stage breast cancer screening.


  • Portable impulse-radar detector for breast cancer: a pilot study

    by Shinsuke Sasada, Norio Masumoto, Hang Song, Keiko Kajitani, Akiko Emi, Takayuki Kadoya, Koji Arihiro, Takamaro Kikkawa, Morihito Okada

    Microwave breast imaging is a painless and nonradiation method. This pilot study aimed to evaluate the detective capability and feasibility of a prototype of a portable breast cancer detector using a radar-based imaging system. Five patients with histologically confirmed breast cancers with a minimum diameter of 1 cm were enrolled in this study. The antenna array dome of the device was placed on the breast of the patient in a supine position for 15 min per single examination. The primary endpoint was a detection rate of breast cancers. The secondary endpoints were positional accuracy and adverse event. All five targeted breast tumors were detected and were visualized at the sites confirmed by other diagnostic modalities. Among five tumors, one was not detected via mammography because of heterogeneously dense breast and another was a microinvasive carcinoma of invasive tumor size 0.5 mm. No study-related adverse events occurred. The prototype of a portable breast cancer detector has sufficient detective capability, is safe for clinical use, and might detect an early stage breast cancer, such as noninvasive carcinoma. Future developments should focus on further decreasing the size of the machine and shortening inspection time.


  • Radar imaging of breast cancer using Kirchhoff migration and singular value decomposition

    by Takuya Sakamoto, Hang Song, Takamaro Kikkawa

    This paper presents a radar imaging technique for breast cancer detection using an ultra-wideband radar. The proposed technique employed modified Kirchhoff migration to achieve high-resolution imaging. In addition, a singular value decomposition was used for noise suppression to obtain a clear image. The proposed technique was applied to experimental data measured using an ultra-wideband array radar system and breast cancer phantom.


  • Open Access

    Detectability of Breast Tumor by a Hand-held Impulse-Radar Detector: Performance Evaluation and Pilot Clinical Study

    by Hang Song, Shinsuke Sasada, Takayuki Kadoya, Morihito Okada, Koji Arihiro, Xia Xiao, Takamaro Kikkawa

    In this report, a hand-held impulse-radar breast cancer detector is presented and the detectability of malignant breast tumors is demonstrated in the clinical test at Hiroshima University Hospital, Hiroshima, Japan. The core functional parts of the detector consist of 65-nm technology complementary metal-oxide-semiconductor (CMOS) integrated circuits covering the ultrawideband width from 3.1 to 10.6 GHz, which enable the generation and transmission of Gaussian monocycle pulse (GMP) with the pulse width of 160 ps and single port eight throw (SP8T) switching matrices for controlling the combination of 4 × 4 cross-shaped dome antenna array. The detector is designed to be placed on the breast with the patient in the supine position. The detectability of malignant tumors is confirmed in excised breast tissues after total mastectomy surgery. The three-dimensional positions of the tumors in the imaging results are consistent with the results of histopathology analysis. The clinical tests are conducted by a clinical doctor for five patients at the hospital. The malignant tumors include invasive ductal carcinoma (IDC) and ductal carcinoma in situ (DCIS). The final confocal imaging results are consistent with those of Magnetic Resonance Imaging (MRI), demonstrating the feasibility of the hand-held impulse-radar detector for malignant breast tumors.


  • Influence of complex permittivity on confocal imaging of 3D-printed breast phantom

    by H. Sato, H. Song, H. Kono, X. Xiao, R. Miyake, T. Kikkawa

    Confocal imaging of a breast tumor phantom embedded in a 3D-printed breast phantom was demonstrated. 16 compact ultra-wideband (UWB) slot antennas were attached on the surface of the 3D-printed breast phantom and confocal imaging of 192 combinations was carried out by a radar-based breast cancer detection system. The breast adipose, glandular and tumor tissues were made of acrylonitrile butadien styrene plastic, the mixture of glycerin and water (saline) and bacon with the size of 10 mm × 10 mm × 10 mm.