Amy B. Zavatsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amy B. Zavatsky has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Julie Stebbins
Oxford Gait Laboratory, Nuffield Orthopaedic Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
5 shared publications- Tim Theologis
Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
4 shared publications - Harinderjit Singh Gill
Professor, Department of Mechanical Engineering, Claverton Down Campus, University of Bath, Bath, UK
3 shared publications - Julie Stebbins
Oxford Gait Laboratory, Oxford University Hospitals NHS Foundation Trust
3 shared publications - C. Paul Buckley
Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK
2 shared publications - C.M. Kerr
Department of Engineering Science, University of Oxford, Parks Road, Oxford, OX1 3PJ, UK
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113477
Evaluation of a smartphone-based markerless motion capture system for assessing the kinematics of gymnastics
- 16 July 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113477
Open AccessEvaluation of a smartphone-based markerless motion capture system for assessing the kinematics of gymnastics
- Open Access
- 4 December 2025
- Published by Elsevier in Gait & Posture
- Vol. 125, 110070
Medio-lateral forefoot segmentation for clinical gait analysis based on metatarsal subunit rigidity and angular motion
- 4 December 2025
- Published by Elsevier in Gait & Posture
- Vol. 125, 110070
Open AccessMedio-lateral forefoot segmentation for clinical gait analysis based on metatarsal subunit rigidity and angular motion
- Open Access
- 4 February 2025
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 29 (7) , 1478-1491
OpenOFM: an open-source implementation of the multi-segment Oxford Foot Model
The Oxford Foot Model (OFM) is a widely-used multi-segment foot model for the evaluation of foot motion. To date, custom code based on the original scientific publications have failed to reproduce results available through the Vicon plug-in (ViconOFM). This highlights a lack of transparency, affecting the accessibility and understanding of the model. Therefore, the aims of this study are to (1) replicate ViconOFM using Python for open-source distribution (openOFM v1.0) and (2) reproduce the original scientific description of the OFM in a second version (openOFM v1.1), highlighting differences between both versions. A dataset comprising one healthy adult and a set of five patients with heterogeneous foot pathologies was used for analyses. Evaluation was conducted using the normalised root mean square error (NRMSE) between the inter-segment angles and arch heights of both implementations. The openOFM v1.1 was developed based on the original OFM publications. The average NRMSE between ViconOFM and openOFM v1.0, using both healthy and pathological gait, was of 0.0012. Based on our openOFM v1.1 implementation, differences between ViconOFM and the original OFM description from the literature are due to an integrated smoothing and gap filling function and changes in segment definitions. The negligible differences between ViconOFM and openOFM v1.0 in healthy and pathological gait supports the concurrent validity of openOFM. Providing users with both openOFM versions enables informed use of either model and allows further investigation into the implications of these differences. The open-source nature of the project promotes further development.
- 4 February 2025
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 29 (7) , 1478-1491
Open AccessOpenOFM: an open-source implementation of the multi-segment Oxford Foot Model
The Oxford Foot Model (OFM) is a widely-used multi-segment foot model for the evaluation of foot motion. To date, custom code based on the original scientific publications have failed to reproduce results available through the Vicon plug-in (ViconOFM). This highlights a lack of transparency, affecting the accessibility and understanding of the model. Therefore, the aims of this study are to (1) replicate ViconOFM using Python for open-source distribution (openOFM v1.0) and (2) reproduce the original scientific description of the OFM in a second version (openOFM v1.1), highlighting differences between both versions. A dataset comprising one healthy adult and a set of five patients with heterogeneous foot pathologies was used for analyses. Evaluation was conducted using the normalised root mean square error (NRMSE) between the inter-segment angles and arch heights of both implementations. The openOFM v1.1 was developed based on the original OFM publications. The average NRMSE between ViconOFM and openOFM v1.0, using both healthy and pathological gait, was of 0.0012. Based on our openOFM v1.1 implementation, differences between ViconOFM and the original OFM description from the literature are due to an integrated smoothing and gap filling function and changes in segment definitions. The negligible differences between ViconOFM and openOFM v1.0 in healthy and pathological gait supports the concurrent validity of openOFM. Providing users with both openOFM versions enables informed use of either model and allows further investigation into the implications of these differences. The open-source nature of the project promotes further development.
- 5 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
A Sensor Placement Benchmarking Method With Principal Component Analysis
Foot plantar pressure measurements are valuable for diverse applications in clinical and biomedical studies. In-shoe devices have recently become popular and are considered effective tools for acquiring foot plantar pressure data thanks to their versatility. However, these devices are subject to low measurement resolution because only a limited number of sensors can be installed due to considerations of cost and comfort. Optimizing the sensor layout could be an effective solution to enhance the measurement quality. Contemporary devices rely either on an understanding of anatomy and practical experience or expensive data-driven approaches to configure the sensor layouts. In this work, we present a sensor placement benchmarking method that bridges the gap between the two aforementioned categories of methods and helps determine sensor layouts efficiently. The benchmarking method utilizes an open-access dataset to evaluate a sensor layout from multiple perspectives, including the accuracy of centre of pressure (CoP) estimation, prediction rate, sensor count and the physical insights generated from conducting principal component analysis on the dataset. Subsequently, the study demonstrates the method’s functionality by applying it to the anatomy-based sensor layouts of two existing devices. Optimal sensor placements are identified, and general guidelines for sensor placement are proposed.
- 5 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
A Sensor Placement Benchmarking Method With Principal Component Analysis
Foot plantar pressure measurements are valuable for diverse applications in clinical and biomedical studies. In-shoe devices have recently become popular and are considered effective tools for acquiring foot plantar pressure data thanks to their versatility. However, these devices are subject to low measurement resolution because only a limited number of sensors can be installed due to considerations of cost and comfort. Optimizing the sensor layout could be an effective solution to enhance the measurement quality. Contemporary devices rely either on an understanding of anatomy and practical experience or expensive data-driven approaches to configure the sensor layouts. In this work, we present a sensor placement benchmarking method that bridges the gap between the two aforementioned categories of methods and helps determine sensor layouts efficiently. The benchmarking method utilizes an open-access dataset to evaluate a sensor layout from multiple perspectives, including the accuracy of centre of pressure (CoP) estimation, prediction rate, sensor count and the physical insights generated from conducting principal component analysis on the dataset. Subsequently, the study demonstrates the method’s functionality by applying it to the anatomy-based sensor layouts of two existing devices. Optimal sensor placements are identified, and general guidelines for sensor placement are proposed.
- Open Access
- 22 July 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 25 (3) , 308-319
Efficacy of quantifying marker-cluster rigidity in a multi-segment foot model: a Monte-Carlo based global sensitivity analysis and regression model
Marker-based clinical gait analysis and multi-segment foot models (MSFM) have been successfully used for the diagnosis and clinical management of various lower limb disorders. The accuracy and validity of the kinematics measured depend on the design of the model, as well as on the adherence to its inherent rigid body assumption. This study applies a Monte-Carlo based global sensitivity analysis to evaluate the efficacy of using ‘rigid body error ( )’ in quantifying the rigidity of a MSFM marker-cluster. A regression model is proposed. It is concluded that is effective in quantifying rigidity.- 22 July 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 25 (3) , 308-319
Open AccessEfficacy of quantifying marker-cluster rigidity in a multi-segment foot model: a Monte-Carlo based global sensitivity analysis and regression model
Marker-based clinical gait analysis and multi-segment foot models (MSFM) have been successfully used for the diagnosis and clinical management of various lower limb disorders. The accuracy and validity of the kinematics measured depend on the design of the model, as well as on the adherence to its inherent rigid body assumption. This study applies a Monte-Carlo based global sensitivity analysis to evaluate the efficacy of using ‘rigid body error ( )’ in quantifying the rigidity of a MSFM marker-cluster. A regression model is proposed. It is concluded that is effective in quantifying rigidity. - 1 August 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 93, 34-41
Comparison of the hindfoot axes of a multi-segment foot model to the underlying bony anatomy
- 1 August 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 93, 34-41
Comparison of the hindfoot axes of a multi-segment foot model to the underlying bony anatomy
- 1 February 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 84, 284-289
Marker cluster rigidity in a multi-segment foot model
- 1 February 2019
- Published by Elsevier in Journal of Biomechanics
- Vol. 84, 284-289
Marker cluster rigidity in a multi-segment foot model
- 1 January 2019
- Published by Elsevier in Gait & Posture
- Vol. 67, 213-218
Kinematic differences between neutral and flat feet with and without symptoms as measured by the Oxford foot model
- 1 January 2019
- Published by Elsevier in Gait & Posture
- Vol. 67, 213-218
Kinematic differences between neutral and flat feet with and without symptoms as measured by the Oxford foot model
- 18 August 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (10) , 101004
Viscoelasticity of Tendons Under Transverse Compression
Tendons are highly anisotropic and also viscoelastic. For understanding and modeling their 3D deformation, information is needed on their viscoelastic response under off-axis loading. A study was made, therefore, of creep and recovery of bovine digital extensor tendons when subjected to transverse compressive stress of up to ca. 100 kPa. Preconditioned tendons were compression tested between glass plates at increasing creep loads. The creep response was anomalous: the relative rate of creep reduced with the increasing stress. Over each ca. 100 s creep period, the transverse creep deformation of each tendon obeyed a power law dependence on time, with the power law exponent falling from ca. 0.18 to an asymptote of ca. 0.058 with the increasing stress. A possible explanation is stress-driven dehydration, as suggested previously for the similar anomalous behavior of ligaments. Recovery after removal of each creep load was also anomalous. Relative residual strain reduced with the increasing creep stress, but this is explicable in terms of the reducing relative rate of creep. When allowance was made for some adhesion occurring naturally between tendon and the glass plates, the results for a given load were consistent with creep and recovery being related through the Boltzmann superposition principle (BSP). The tendon tissue acted as a pressure-sensitive adhesive (PSA) in contact with the glass plates: explicable in terms of the low transverse shear modulus of the tendons.
- 18 August 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (10) , 101004
Viscoelasticity of Tendons Under Transverse Compression
Tendons are highly anisotropic and also viscoelastic. For understanding and modeling their 3D deformation, information is needed on their viscoelastic response under off-axis loading. A study was made, therefore, of creep and recovery of bovine digital extensor tendons when subjected to transverse compressive stress of up to ca. 100 kPa. Preconditioned tendons were compression tested between glass plates at increasing creep loads. The creep response was anomalous: the relative rate of creep reduced with the increasing stress. Over each ca. 100 s creep period, the transverse creep deformation of each tendon obeyed a power law dependence on time, with the power law exponent falling from ca. 0.18 to an asymptote of ca. 0.058 with the increasing stress. A possible explanation is stress-driven dehydration, as suggested previously for the similar anomalous behavior of ligaments. Recovery after removal of each creep load was also anomalous. Relative residual strain reduced with the increasing creep stress, but this is explicable in terms of the reducing relative rate of creep. When allowance was made for some adhesion occurring naturally between tendon and the glass plates, the results for a given load were consistent with creep and recovery being related through the Boltzmann superposition principle (BSP). The tendon tissue acted as a pressure-sensitive adhesive (PSA) in contact with the glass plates: explicable in terms of the low transverse shear modulus of the tendons.
- 19 February 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (4) , 041002
Transverse Compression of Tendons
A study was made of the deformation of tendons when compressed transverse to the fiber-aligned axis. Bovine digital extensor tendons were compression tested between flat rigid plates. The methods included: in situ image-based measurement of tendon cross-sectional shapes, after preconditioning but immediately prior to testing; multiple constant-load creep/recovery tests applied to each tendon at increasing loads; and measurements of the resulting tendon displacements in both transverse directions. In these tests, friction resisted axial stretch of the tendon during compression, giving approximately plane-strain conditions. This, together with the assumption of a form of anisotropic hyperelastic constitutive model proposed previously for tendon, justified modeling the isochronal response of tendon as that of an isotropic, slightly compressible, neo-Hookean solid. Inverse analysis, using finite-element (FE) simulations of the experiments and 10 s isochronal creep displacement data, gave values for Young's modulus and Poisson's ratio of this solid of 0.31 MPa and 0.49, respectively, for an idealized tendon shape and averaged data for all the tendons and E = 0.14 and 0.10 MPa for two specific tendons using their actual measured geometry. The compression load versus displacement curves, as measured and as simulated, showed varying degrees of stiffening with increasing load. This can be attributed mostly to geometrical changes in tendon cross section under load, varying according to the initial 3D shape of the tendon.
- 19 February 2016
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (4) , 041002
Transverse Compression of Tendons
A study was made of the deformation of tendons when compressed transverse to the fiber-aligned axis. Bovine digital extensor tendons were compression tested between flat rigid plates. The methods included: in situ image-based measurement of tendon cross-sectional shapes, after preconditioning but immediately prior to testing; multiple constant-load creep/recovery tests applied to each tendon at increasing loads; and measurements of the resulting tendon displacements in both transverse directions. In these tests, friction resisted axial stretch of the tendon during compression, giving approximately plane-strain conditions. This, together with the assumption of a form of anisotropic hyperelastic constitutive model proposed previously for tendon, justified modeling the isochronal response of tendon as that of an isotropic, slightly compressible, neo-Hookean solid. Inverse analysis, using finite-element (FE) simulations of the experiments and 10 s isochronal creep displacement data, gave values for Young's modulus and Poisson's ratio of this solid of 0.31 MPa and 0.49, respectively, for an idealized tendon shape and averaged data for all the tendons and E = 0.14 and 0.10 MPa for two specific tendons using their actual measured geometry. The compression load versus displacement curves, as measured and as simulated, showed varying degrees of stiffening with increasing load. This can be attributed mostly to geometrical changes in tendon cross section under load, varying according to the initial 3D shape of the tendon.