GBGiovanni Benato

Giovanni Benato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giovanni Benato has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Probing dark matter interactions with a RES–NOVA prototype cryogenic detector

    by D. Alloni, G. Benato, P. Carniti, M. Cataldo, L. Chen, M. Clemenza, M. Consonni, G. Croci, I. Dafinei, F. A. Danevich, et al.

    We report on the operation of a 13 g PbWO $$_4$$ 4 crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermistor, the detector achieves a low energy threshold and, for the first time, enables the derivation of a dark matter exclusion limit using PbWO $$_4$$ 4 as target material, for both spin-dependent interactions on neutrons and spin-independent interactions. Although limited in mass and not representative of the final RES–NOVA detector design, this prototype demonstrates effective control of mechanical vibrations and low-energy noise in a cryogenic system, which is a key requirement for rare-event searches. The experiment therefore provides a proof of principle for the RES–NOVA detection concept, validating the use of archaeological Pb-based PbWO $$_4$$ 4 crystals, low-background operation, and robust data-analysis procedures. These results establish a solid technological and methodological foundation for future RES–NOVA detectors employing larger target masses and advanced thermal readout technologies.

  • Open Access

    Toward high-resolution low-energy electron spectroscopy with transition-edge sensors

    by R. Ammendola, A. Apponi, G. Benato, M. G. Betti, R. Biondi, P. Bos, M. Cadeddu, A. Casale, O. Castellano, G. Cavoto, et al.

    We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

  • Open Access

    High-precision measurement of 215 Po half-life via delayed-coincidence analysis

    by Lorenzo Ascenzo, Melissa Hoda Baiocchi, Giovanni Benato, Yingjie Chu, Giuseppe Di Carlo, Andrea Molinario, Silvia Vernetto

    We performed a high-precision study of the 215 Po α -decay using a LaBr 3 scintillating detector in a low-background environment. The 227 Ac intrinsic contamination in the LaBr 3 crystal undergoes a decay chain, producing the intermediate pair of 219 Rn→ 215 Po→ 211 Pb decays. The fast time response and good energy resolution of the detector allow for extracting the short half-life of 215 Po from the time correlation of the two subsequent α -decays by using the delayed coincidence method. Thanks to high statistics and a comprehensive uncertainty assessment, we obtain the most precise half-life value to date of 215 Po, corresponding to 1.77804 ± 0.00091(stat.) ± 0.00023(syst.) ms. This measurement served the further purpose of benchmarking the half-life of its mother nucleus 219 Rn, which is 3.921 ± 0.031(stat.) ± 0.083(syst.) s.

  • Open Access

    Neutrino NSI in archaeological Pb

    by D. Alloni, G. Benato, P. Carniti, M. Cataldo, D. Cerdeño, A. Cheek, L. Chen, M. Clemenza, M. Consonni, G. Croci, et al.

    A bstract: Dark matter direct detection experiments can observe solar neutrinos via coherent elastic neutrino-nucleus scattering, making it possible to test new physics in the neutrino sector. In this article, we study the sensitivity of RES-NOVA, a novel cryogenic calorimetric experiment employing PbWO 4 crystals grown from archaeological lead, to neutrino non-standard interactions (NSI). We perform a sensitivity study for a benchmark setup with a nominal energy threshold of 1 keV and an exposure of 1 ton·yr, both for a conservative (only heat readout) and ideal (heat and scintillation) background rejection scenario. We find that, in its nominal configuration, while not being sensitive to Standard Model solar ν interactions, RES-NOVA can reach sensitivities to NSI at the level of current global fits. With moderate or significant improvements of the threshold down to 0 . 5 keV and 0 . 2 keV, RES-NOVA will be able to achieve sensitivities beyond NSI global fit results, testing new areas of the parameter space in the electron and tau sectors, ε ee , ε ττ , and ε eτ . A similar improvement in sensitivities is expected when instead increasing the exposure to 10 ton·yr.

  • Open Access

    The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment

    by D. Q. Adams, C. Alduino, K. Alfonso, A. Armatol, F. T. Avignone, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, et al.

    Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta (0 ν β β ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0 ν β β decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0 ν β β decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.


  • Open Access

    High-precision measurement of $^{215}$Po half-life via delayed-coincidence analysis

    by Lorenzo Ascenzo, Melissa Hoda Baiocchi, Giovanni Benato, Yingjie Chu, Giuseppe Di Carlo, Andrea Molinario, Silvia Vernetto

    We performed a high-precision study of the $^{215}$ Po $α$-decay using a LaBr$_3$ scintillating detector in a low-background environment. The $^{227}$Ac intrinsic contamination in the LaBr$_3$ crystal undergoes a decay chain, producing the intermediate pair of $^{219}$Rn$\rightarrow^{215}$Po$\rightarrow^{211}$Pb decays. The fast time response and good energy resolution of the detector allow for extracting the short half-life of $^{215}$Po from the time correlation of the two subsequent $α$-decays by using the delayed coincidence method. Thanks to high statistics and a comprehensive uncertainty assessment, we obtain the most precise half-life value to date of $^{215}$Po, corresponding to $1.77804\pm0.00091$(stat.)$\pm0.00067$(syst.) ms.

  • Open Access

    Characterization of a GAGG detector for neutron measurements in underground laboratories

    by L. Ascenzo, G. Benato, Y. Chu, G. Di Carlo, A. Molinario, S. Vernetto

    In rare events experiments, such as those devoted to the direct search of dark matter, a precise knowledge of the environmental gamma and neutron backgrounds is crucial for reaching the design experiment sensitivity. The neutron component is often poorly known due to the lack of a scalable detector technology for the precise measurement of low-flux neutron spectra. $$\hbox {Gd}_{3}\hbox {Al}_{2}\hbox {Ga}_{3}\hbox {O}_{12}$$ Gd 3 Al 2 Ga 3 O 12 :Ce (GAGG) is a newly developed, high-density scintillating crystal with a high gadolinium content, which could allow to exploit the high $$(n,\gamma )$$ ( n , γ ) cross section of 155Gd and 157Gd for neutron measurements in underground environments. GAGG crystals feature a high scintillation light yield, good timing performance, and the capability of particle identification via pulse-shape discrimination. In a low-background environment, the distinctive signature produced by neutron capture on gadolinium, namely a $$\beta /\gamma $$ β / γ cascade releasing up to 9 MeV of total energy, and the efficient particle identification provided by GAGG could yield a background-free neutron capture signal. In this work, we present the characterization of a first GAGG detector prototype in terms of particle discrimination performance, intrinsic radioactive contamination, and neutron response.


  • Open Access

    Characterization of a GAGG detector for neutron measurements in underground laboratories

    by Lorenzo Ascenzo, Giovanni Benato, Yingjie Chu, Giuseppe Di Carlo, Andrea Molinario, Silvia Vernetto

    In rare events experiments, such as those devoted to the direct search of dark matter, a precise knowledge of the environmental gamma and neutron backgrounds is crucial for reaching the design experiment sensitivity. The neutron component is often poorly known due to the lack of a scalable detector technology for the precise measurement of low-flux neutron spectra. Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG) is a newly developed, high-density scintillating crystal with a high gadolinium content, which could allow to exploit the high $(n,γ)$ cross section of $^{155}$Gd and $^{157}$Gd for neutron measurements in underground environments. GAGG crystals feature a high scintillation light yield, good timing performance, and the capability of particle identification via pulse-shape discrimination. In a low-background environment, the distinctive signature produced by neutron capture on gadolinium, namely a $β/γ$ cascade releasing up to 9 MeV of total energy, and the efficient particle identification provided by GAGG could yield a background-free neutron capture signal. In this work, we present the characterization of a first GAGG detector prototype in terms of particle discrimination performance, intrinsic radioactive contamination, and neutron response.

  • Development of ultralow-background cryogenic calorimeters for the measurement of surface α contamination

    by G. Benato, M. Biassoni, C. Brofferio, E. Celi, S. Dell’oRo, A. Drobizhev, A. Gianvecchio, M. Girola, S. Ghislandi, Yu.G. Kolomensky, et al.