Gonzalo Daniel Maso Talou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gonzalo Daniel Maso Talou has a total of 185 co-authors. Here are the top co-authors by number of shared publications:
- Pablo Javier Blanco
National Laboratory for Scientific Computing, LNCC/MCTI, Av. Getúlio Vargas 333, Petrópolis, 25651-075, Brazil
17 shared publications - Cristiano Guedes Bezerra
Hospital Aliança Rede D’Or, Brasil
10 shared publications - Pedro Alves Lemos
Hospital Israelita Albert Einstein
9 shared publications - Soroush Safaei
Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
9 shared publications - Carlos Alberto Bulant
National Laboratory for Scientific Computing, LNCC/MCTIC, Av. Getúlio Vargas, 333, Petrópolis-RJ, 25651-075, Brazil
7 shared publications - Sergio Dempsey
Auckland Bioengineering Institute, University of Auckland
7 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1780895
Design and formative usability evaluation of a prototype integrated digital health platform for chronic care support
Introduction: Chronic care management platforms often support only one or two core pillars of care, such as patient monitoring, patient activation, and data-driven care coordination. This fragmentation can limit the continuity of support and reduce the usefulness of shared patient data among patients, coaches, and clinicians. Method: This study describes the design, software architecture, and formative usability evaluation of the Digital Health Navigator (DiNa) platform, an integrated system designed to bring together the core pillars of chronic care management. DiNa combines wearable and self-reported monitoring, a large language model-powered embodied conversational agent, and a coordinator dashboard within a single modular ecosystem. DiNa was implemented as an Android application, a web-based coordinator dashboard, a microservices backend, and wearable integrations with a smartwatch and a continuous glucose monitor. The embodied conversational agent supports goal setting, logging, reminders, and knowledge-grounded education through coaching informed by motivational interviewing and cognitive behavioural therapy. We conducted moderated laboratory think-aloud usability sessions with 10 relatively young healthy volunteers familiar with digital health tracking. Participants explored the application and completed structured tasks, including setting goals, logging meals with an image, reviewing history, interacting with the coach, and viewing trends. Results: Outcomes included task performance, the System Usability Scale (SUS), a brief NASA Task Load Index (NASA-TLX), three acceptability items, and a reflexive thematic analysis of interviews. Participants completed the core tasks in a facilitated session, and a small number of critical breakdowns were observed and quantified. Mean SUS was 76.1 (SD 15.0), indicating generally good usability. Overall, the NASA-TLX workload averaged 26.7, with mental demand and effort higher than the other subscales and the remaining subscales low. Acceptability ratings indicated moderate early acceptability, with perceived usefulness rated more positively than near-term use or recommendation. Qualitative analysis identified five themes, including burdensome and sometimes unclear logging workflows, uneven goal setting, a friendly but occasionally generic coach, interface elements that reduced confidence, and a strong interest in integration with existing devices and applications. Discussion: These findings provide early evidence that an integrated platform combining continuous sensing, conversational coaching, and clinician-facing coordination is technically feasible and usable in a controlled setting with healthy volunteers, and they identify the workflow refinements needed before evaluation in clinically representative populations.
- 22 October 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1780895
Open AccessDesign and formative usability evaluation of a prototype integrated digital health platform for chronic care support
Introduction: Chronic care management platforms often support only one or two core pillars of care, such as patient monitoring, patient activation, and data-driven care coordination. This fragmentation can limit the continuity of support and reduce the usefulness of shared patient data among patients, coaches, and clinicians. Method: This study describes the design, software architecture, and formative usability evaluation of the Digital Health Navigator (DiNa) platform, an integrated system designed to bring together the core pillars of chronic care management. DiNa combines wearable and self-reported monitoring, a large language model-powered embodied conversational agent, and a coordinator dashboard within a single modular ecosystem. DiNa was implemented as an Android application, a web-based coordinator dashboard, a microservices backend, and wearable integrations with a smartwatch and a continuous glucose monitor. The embodied conversational agent supports goal setting, logging, reminders, and knowledge-grounded education through coaching informed by motivational interviewing and cognitive behavioural therapy. We conducted moderated laboratory think-aloud usability sessions with 10 relatively young healthy volunteers familiar with digital health tracking. Participants explored the application and completed structured tasks, including setting goals, logging meals with an image, reviewing history, interacting with the coach, and viewing trends. Results: Outcomes included task performance, the System Usability Scale (SUS), a brief NASA Task Load Index (NASA-TLX), three acceptability items, and a reflexive thematic analysis of interviews. Participants completed the core tasks in a facilitated session, and a small number of critical breakdowns were observed and quantified. Mean SUS was 76.1 (SD 15.0), indicating generally good usability. Overall, the NASA-TLX workload averaged 26.7, with mental demand and effort higher than the other subscales and the remaining subscales low. Acceptability ratings indicated moderate early acceptability, with perceived usefulness rated more positively than near-term use or recommendation. Qualitative analysis identified five themes, including burdensome and sometimes unclear logging workflows, uneven goal setting, a friendly but occasionally generic coach, interface elements that reduced confidence, and a strong interest in integration with existing devices and applications. Discussion: These findings provide early evidence that an integrated platform combining continuous sensing, conversational coaching, and clinician-facing coordination is technically feasible and usable in a controlled setting with healthy volunteers, and they identify the workflow refinements needed before evaluation in clinically representative populations.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Multi-Camera Calibration With Imperfect 3-D Targets for Imaging Biological Systems
High-resolution multi-view stereo camera systems provide an opportunity for precise measurement of shapes, deformations, and displacements. These systems are especially useful for instrumentation and measurement of small-scale biological systems. Often, these are so precise that their measurements have greater precision than the achievable manufacturing precision of calibration targets, limiting the accuracy of template-based calibrations. This work extends the calibration of camera systems using imperfect planar calibration targets to 3D targets, allowing robust calibration of these high-resolution stereo systems. Results are reported for three separate camera systems, designed for human-scale, skin surface, and single-organ imaging. Recovery of target imperfections, to within 20 μm for a 40 mm target, and improved reprojection errors are demonstrated. The proposed calibration of imperfect targets is shown to be more robust to imperfections in the points chosen to constrain the calibration than previous methods. For systems with relatively precise targets, small improvements are shown in calibration results (from 0.91 pixels to 0.59 pixels of Euclidean error) with limited change in measurements from the system. For imprecise targets, the results show notable improvements in reprojection errors (improving from 4.30 pixels to 1.34 pixels and 5.85 pixels to 0.61 pixels of Euclidean error) and improvements in reconstruction based measurement, reconstructing an additional 10% of the subject.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Multi-Camera Calibration With Imperfect 3-D Targets for Imaging Biological Systems
High-resolution multi-view stereo camera systems provide an opportunity for precise measurement of shapes, deformations, and displacements. These systems are especially useful for instrumentation and measurement of small-scale biological systems. Often, these are so precise that their measurements have greater precision than the achievable manufacturing precision of calibration targets, limiting the accuracy of template-based calibrations. This work extends the calibration of camera systems using imperfect planar calibration targets to 3D targets, allowing robust calibration of these high-resolution stereo systems. Results are reported for three separate camera systems, designed for human-scale, skin surface, and single-organ imaging. Recovery of target imperfections, to within 20 μm for a 40 mm target, and improved reprojection errors are demonstrated. The proposed calibration of imperfect targets is shown to be more robust to imperfections in the points chosen to constrain the calibration than previous methods. For systems with relatively precise targets, small improvements are shown in calibration results (from 0.91 pixels to 0.59 pixels of Euclidean error) with limited change in measurements from the system. For imprecise targets, the results show notable improvements in reprojection errors (improving from 4.30 pixels to 1.34 pixels and 5.85 pixels to 0.61 pixels of Euclidean error) and improvements in reconstruction based measurement, reconstructing an additional 10% of the subject.
- Open Access
- 14 January 2026
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (1)
Evaluating SegResNet for single-modality meningioma segmentation on T1 contrast-enhanced MRI on a New Zealand clinical cohort
- 14 January 2026
- Published by Elsevier in Neuroscience Informatics
- Vol. 6 (1)
Open AccessEvaluating SegResNet for single-modality meningioma segmentation on T1 contrast-enhanced MRI on a New Zealand clinical cohort
- Open Access
- 8 September 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (9) , e1013459
Blood flow in the human cerebral cortex: Large-scale pial vascularization and 1D simulation
Understanding cerebral circulation is crucial for early diagnosis and patient-oriented therapies for brain conditions. However, blood flow simulations at the organ scale have been limited. This work introduces a framework for modeling extensive vascular networks in the human cerebral cortex and conducting pulsatile blood flow simulations. Using a patient-specific cerebral geometry, we applied a parallelized adaptive constrained constructive optimization algorithm to create a comprehensive pial vascular network in the left hemisphere, starting from the main cerebral arteries. The resulting network included over 75 000, 103 000, and 55 000 vessels for the anterior, middle, and posterior territories, respectively. Pial vessel diameters featured a median [interquartile range, IQR] value of . We integrated the pial vascular network model with the Anatomically-Detailed Arterial Network (ADAN) model to conduct one-dimensional (1D) blood flow simulations under normotensive and hypertensive conditions. Viscoelastic dissipation proved to be a key ingredient in the characterization of the hemodynamic environments in the pial circulation. In the normotensive scenario, mean blood pressure in the pial vessels resulted in a median [IQR] value of . The flow pulsatility index and its corresponding damping factor were effective descriptors of the hypertensive state. The median [IQR] pulsatility index in the normotensive state was , and in hypertension it increased up to , while its corresponding damping factor in the normotensive state was , and in the hypertensive state it was reduced to . We observed large regional pressure gradients in terminal vessels, with pressure levels ranging from in normotension to in hypertension. Additionally, the pulsatility index at terminal vessels increased with distance from the Circle of Willis in the hypertensive case, contrasting with the decreasing pattern seen in normotension. This approach provides a unique characterization of hemodynamics in the pial vascular network of the human cerebral cortex, paving the way for research into microcirculatory environments, the link between hemodynamics and neural function, and their roles in conditions like stroke and dementia.- 8 September 2025
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 21 (9) , e1013459
Open AccessBlood flow in the human cerebral cortex: Large-scale pial vascularization and 1D simulation
Understanding cerebral circulation is crucial for early diagnosis and patient-oriented therapies for brain conditions. However, blood flow simulations at the organ scale have been limited. This work introduces a framework for modeling extensive vascular networks in the human cerebral cortex and conducting pulsatile blood flow simulations. Using a patient-specific cerebral geometry, we applied a parallelized adaptive constrained constructive optimization algorithm to create a comprehensive pial vascular network in the left hemisphere, starting from the main cerebral arteries. The resulting network included over 75 000, 103 000, and 55 000 vessels for the anterior, middle, and posterior territories, respectively. Pial vessel diameters featured a median [interquartile range, IQR] value of . We integrated the pial vascular network model with the Anatomically-Detailed Arterial Network (ADAN) model to conduct one-dimensional (1D) blood flow simulations under normotensive and hypertensive conditions. Viscoelastic dissipation proved to be a key ingredient in the characterization of the hemodynamic environments in the pial circulation. In the normotensive scenario, mean blood pressure in the pial vessels resulted in a median [IQR] value of . The flow pulsatility index and its corresponding damping factor were effective descriptors of the hypertensive state. The median [IQR] pulsatility index in the normotensive state was , and in hypertension it increased up to , while its corresponding damping factor in the normotensive state was , and in the hypertensive state it was reduced to . We observed large regional pressure gradients in terminal vessels, with pressure levels ranging from in normotension to in hypertension. Additionally, the pulsatility index at terminal vessels increased with distance from the Circle of Willis in the hypertensive case, contrasting with the decreasing pattern seen in normotension. This approach provides a unique characterization of hemodynamics in the pial vascular network of the human cerebral cortex, paving the way for research into microcirculatory environments, the link between hemodynamics and neural function, and their roles in conditions like stroke and dementia. - Open Access
Regional and Global Analysis of Cerebrovascular Reactivity Using 4D Flow MRI
Cerebrovascular reactivity (CVR) assessments are promising for diagnostic and prognostic applications related to vascular function and neurodegenerative diseases. Current vascular imaging-based CVR indices have been limited to single-vessel analysis and report conflicting results, for example, whether there are differences in CVR between sexes. Alternative vascular imaging-based indices can be derived from 4D flow MRI, namely intracranial pulse wave velocity and pulsatility transmission, which are based on vascular regions and offer a more comprehensive perspective on vascular function that can also scale to a global level. To date, these types of indices have not been measured with a vascular stimulus. In this work, standard single-vessel and novel regional and global CVR indices were studied in 10 healthy young adults (29 ± 2 years, 5 male, 5 female) in response to hypercapnia. Consistent increases in flow, area and velocity manifested at all levels and were greater in males. Regional pulse wave velocity and pulsatility transmission offered a minimum 40% increase in the dynamic range of CVR magnitudes that may benefit cohort stratification. Notably, pulse wave velocity increased in 50% of the vascular regions (most probably due to vasoconstriction), accompanying an increase in flow; a profound observation given the common expectation of vasorelaxation with hypercapnia. Consistently reduced flow, velocity, area, pulse wave velocity, and transmission index reactivities in females may partially explain the varying pathological outcomes between sexes, evidencing the continued value of 4D flow for the evaluation of CVR in other cohorts. New and Noteworthy: Cerebrovascular reactivity (CVR) of 4D flow-based intracranial pulse wave velocity and pulsatility transmission were evaluated during hypercapnia for the first time. Remarkably, pulse wave velocity increased in some cases and decreased in others, suggesting that vasorelaxation may not always occur during hypercapnia. These indices also expanded CVR dynamic range by more than 40 % compared to common velocimetry techniques, which could offer improved cohort stratification. Evidence of diminished CVR in females was also observed.
Open AccessRegional and Global Analysis of Cerebrovascular Reactivity Using 4D Flow MRI
Cerebrovascular reactivity (CVR) assessments are promising for diagnostic and prognostic applications related to vascular function and neurodegenerative diseases. Current vascular imaging-based CVR indices have been limited to single-vessel analysis and report conflicting results, for example, whether there are differences in CVR between sexes. Alternative vascular imaging-based indices can be derived from 4D flow MRI, namely intracranial pulse wave velocity and pulsatility transmission, which are based on vascular regions and offer a more comprehensive perspective on vascular function that can also scale to a global level. To date, these types of indices have not been measured with a vascular stimulus. In this work, standard single-vessel and novel regional and global CVR indices were studied in 10 healthy young adults (29 ± 2 years, 5 male, 5 female) in response to hypercapnia. Consistent increases in flow, area and velocity manifested at all levels and were greater in males. Regional pulse wave velocity and pulsatility transmission offered a minimum 40% increase in the dynamic range of CVR magnitudes that may benefit cohort stratification. Notably, pulse wave velocity increased in 50% of the vascular regions (most probably due to vasoconstriction), accompanying an increase in flow; a profound observation given the common expectation of vasorelaxation with hypercapnia. Consistently reduced flow, velocity, area, pulse wave velocity, and transmission index reactivities in females may partially explain the varying pathological outcomes between sexes, evidencing the continued value of 4D flow for the evaluation of CVR in other cohorts. New and Noteworthy: Cerebrovascular reactivity (CVR) of 4D flow-based intracranial pulse wave velocity and pulsatility transmission were evaluated during hypercapnia for the first time. Remarkably, pulse wave velocity increased in some cases and decreased in others, suggesting that vasorelaxation may not always occur during hypercapnia. These indices also expanded CVR dynamic range by more than 40 % compared to common velocimetry techniques, which could offer improved cohort stratification. Evidence of diminished CVR in females was also observed.
- Open Access
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240049
Dynamic visualization of brain pulsations using amplified MRI: methodology and applications
Brain pulsatility offers a compelling application in the study of cerebral biomechanics, particularly for mild traumatic brain injury (mTBI) and elevated intracranial pressure (ICP). In this study, we used amplified MRI to quantify brain tissue pulsations. Dynamic mode decomposition (DMD) processing was then applied to provide a spatio-temporal analysis of motion. Four distinct use cases were examined: (i) resting versus exertion-induced heart rate changes, (ii) pre- and post-lumbar puncture (LP), (iii) baseline versus post-brain injury, and (iv) a test–retest case. Results demonstrate that brain tissue motion varies significantly across conditions, with DMD revealing distinct modes and frequencies corresponding to physiological changes. Notably, mTBI showed an increase in pulsatile motion post-injury, while elevated ICP exhibited altered pulsatility patterns post-LP, indicating a potential biomarker for injury and pressure-related changes. This approach offers new insights into physiological and pathological brain pulsatility; however, the study’s limited sample size, reliance on retrospective gating and assumptions regarding pulsatile motion highlight the need for larger and more diverse cohorts to confirm these findings. Despite these limitations, our results suggest our dynamical analysis approach could become a valuable tool for assessing intracranial dynamics, with applications in clinical diagnostics and research on neurovascular and neurological conditions.
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240049
Open AccessDynamic visualization of brain pulsations using amplified MRI: methodology and applications
Brain pulsatility offers a compelling application in the study of cerebral biomechanics, particularly for mild traumatic brain injury (mTBI) and elevated intracranial pressure (ICP). In this study, we used amplified MRI to quantify brain tissue pulsations. Dynamic mode decomposition (DMD) processing was then applied to provide a spatio-temporal analysis of motion. Four distinct use cases were examined: (i) resting versus exertion-induced heart rate changes, (ii) pre- and post-lumbar puncture (LP), (iii) baseline versus post-brain injury, and (iv) a test–retest case. Results demonstrate that brain tissue motion varies significantly across conditions, with DMD revealing distinct modes and frequencies corresponding to physiological changes. Notably, mTBI showed an increase in pulsatile motion post-injury, while elevated ICP exhibited altered pulsatility patterns post-LP, indicating a potential biomarker for injury and pressure-related changes. This approach offers new insights into physiological and pathological brain pulsatility; however, the study’s limited sample size, reliance on retrospective gating and assumptions regarding pulsatile motion highlight the need for larger and more diverse cohorts to confirm these findings. Despite these limitations, our results suggest our dynamical analysis approach could become a valuable tool for assessing intracranial dynamics, with applications in clinical diagnostics and research on neurovascular and neurological conditions.
- Open Access
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240043
Exercise modulates brain pulsatility: insights from q-aMRI and MRI-based flow methods
This study investigates intracranial dynamics following the Monro–Kellie doctrine, depicting how brain pulsatility, cerebrospinal fluid (CSF) flow and cerebral blood flow (CBF) interact under resting and exercise conditions. Using quantitative amplified magnetic resonance imaging (q-aMRI) alongside traditional MRI flow metrics, we measured and analysed blood flow, CSF dynamics and brain displacement in a cohort of healthy adults both at rest and during low-intensity handgrip exercise. Exercise was found to reduce pulsatility in CBF while increasing CSF flow and eliminating CSF regurgitation, highlighting a shift towards more sustained forward flow patterns (from cranial to spinal compartments). Displacement analysis using q-aMRI revealed a consistent trend of reduced whole brain motion during exercise, though as the sample of data that met quality control was low ( n = 5), this was not a significant result. There was an observable decrease in the motion of third and fourth ventricles, linking ventricular displacement to CSF flow alterations. These findings suggest that exercise may not only affect the rate and directionality of CSF flow but also modulate brain tissue motion, supporting cerebral homeostasis. This study offers insights into how the brain adapts dynamically under varying conditions, with implications for understanding intracranial pressure regulation in humans and diagnostic contexts.
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240043
Open AccessExercise modulates brain pulsatility: insights from q-aMRI and MRI-based flow methods
This study investigates intracranial dynamics following the Monro–Kellie doctrine, depicting how brain pulsatility, cerebrospinal fluid (CSF) flow and cerebral blood flow (CBF) interact under resting and exercise conditions. Using quantitative amplified magnetic resonance imaging (q-aMRI) alongside traditional MRI flow metrics, we measured and analysed blood flow, CSF dynamics and brain displacement in a cohort of healthy adults both at rest and during low-intensity handgrip exercise. Exercise was found to reduce pulsatility in CBF while increasing CSF flow and eliminating CSF regurgitation, highlighting a shift towards more sustained forward flow patterns (from cranial to spinal compartments). Displacement analysis using q-aMRI revealed a consistent trend of reduced whole brain motion during exercise, though as the sample of data that met quality control was low ( n = 5), this was not a significant result. There was an observable decrease in the motion of third and fourth ventricles, linking ventricular displacement to CSF flow alterations. These findings suggest that exercise may not only affect the rate and directionality of CSF flow but also modulate brain tissue motion, supporting cerebral homeostasis. This study offers insights into how the brain adapts dynamically under varying conditions, with implications for understanding intracranial pressure regulation in humans and diagnostic contexts.
- Open Access
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240036
Intracranial pulse wave velocity using 4D flow MRI: method comparison and covariate analysis
Intracranial pulse wave velocity (PWV) offers the potential to enhance neurovascular care when evaluating cerebrovascular disease. Using 4D flow MRI, we measured PWV in the intracranial vasculature stemming from the internal carotids and basilar arteries using three popular techniques: cross-correlation, waveform optimization and time-to-upstroke which have all been used intracranially, but never compared. Near-perfect agreement between cross-correlation and waveform optimization methods was observed, while the time-to-upstroke method estimated a significantly larger PWV and was more prone to non-physiological values in a cohort of 21 healthy individuals aged 48 ± 18 years. We then analysed our cohort PWV using an ensemble approach given the current lack of methodological consensus. This analysis identified two consistent findings. First, internal carotids measure significantly higher PWV than basilar vascular networks (3.64 ± 1.47 versus 2.53 ± 1.39 m s −1 ). Second, in our cohort, intracranial PWV was age-independent. We hypothesize that age independence is a healthy physiological trait to minimize microvascular strain, protecting the integrity of the peripheral bed throughout ageing and cardiac pulsatile deformation. The cause for apparent age independence remains unknown. We also identified that previous work on intracranial PWV is likely biased towards the extracranial vasculature, which may explain the study differences in PWV magnitude and the age-dependent nature.
- 4 April 2025
- Published by The Royal Society in Interface Focus
- Vol. 15 (1) , 20240036
Open AccessIntracranial pulse wave velocity using 4D flow MRI: method comparison and covariate analysis
Intracranial pulse wave velocity (PWV) offers the potential to enhance neurovascular care when evaluating cerebrovascular disease. Using 4D flow MRI, we measured PWV in the intracranial vasculature stemming from the internal carotids and basilar arteries using three popular techniques: cross-correlation, waveform optimization and time-to-upstroke which have all been used intracranially, but never compared. Near-perfect agreement between cross-correlation and waveform optimization methods was observed, while the time-to-upstroke method estimated a significantly larger PWV and was more prone to non-physiological values in a cohort of 21 healthy individuals aged 48 ± 18 years. We then analysed our cohort PWV using an ensemble approach given the current lack of methodological consensus. This analysis identified two consistent findings. First, internal carotids measure significantly higher PWV than basilar vascular networks (3.64 ± 1.47 versus 2.53 ± 1.39 m s −1 ). Second, in our cohort, intracranial PWV was age-independent. We hypothesize that age independence is a healthy physiological trait to minimize microvascular strain, protecting the integrity of the peripheral bed throughout ageing and cardiac pulsatile deformation. The cause for apparent age independence remains unknown. We also identified that previous work on intracranial PWV is likely biased towards the extracranial vasculature, which may explain the study differences in PWV magnitude and the age-dependent nature.
- Open Access
- 12 February 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 105
Decoding emotions through personalized multi-modal fNIRS-EEG Systems: Exploring deterministic fusion techniques
- 12 February 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 105
Open AccessDecoding emotions through personalized multi-modal fNIRS-EEG Systems: Exploring deterministic fusion techniques
- Open Access
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Into the gray matter: construction and coupling of multiscale highly-detailed arterial networks in the human cerebral cortex
Stroke-related diseases represent 11% of worldwide deaths. State-of-the-art medical imaging describes many aspects of cerebral circulation. Nevertheless, the limited resolution of these techniques hinders the study of the hemodynamics in smaller vessels. Computational models aid in this problem, providing tools to characterize cerebral hemodynamics in clinical scenarios of interest that are otherwise inaccessible. This work aims to build vascular networks in the human cerebral cortex to study hemodynamics across different regions of the gray matter. The method is based on the Constrained Constructive Optimization method (CCO), called PDCCO, which generates vascular networks following a set of anatomical rules. A patient-specific MRI geometry of the cerebral gray matter is used to register an existing vascular model of the major cerebral vessels in the pial surface of the brain, from where the network is expanded. The brain geometry is partitioned into three territories for each large cerebral artery. The vascular generation is conducted independently for each territory and merged into a single network. First, a thin volume of the pial surface is filled with blood vessels down to the scale of penetrating arterioles of 50 μm. The network is further extended downwards to penetrate the gray matter, and deep vascularization is achieved by appending sub-tree networks to each terminal vessel. These sub-trees are generated separately with vascular properties associated with the gray matter. The final network reaches 234000 vascular segments in the pial network, out of which 116977 are terminal vessels. In turn, each terminal vessel gives rise to a network of 50 terminals, yielding 5 million terminals, and 10 million vascular segments, for each hemisphere. Over the pial surface, the diameters vary between 2100 μm and 26 μm, with terminals between 50 μm and 60 μm, and the pressure drops from 100 mmHg to a range between 50 mmHg and 70 mmHg. The network can be coupled with existing blood flow models of the entire cardiovascular system for the simulation of pulsatile blood flow to study pressure heterogeneities along the cerebral cortex in normal and pathological systemic conditions. This novel approach proposes a strategy for the automatic vascularization of the brain, with the aim of understanding microcirculation under different conditions, allowing the study of the risk of stroke, among other mechanisms involved in the onset and progress of degenerative diseases.
- 2 December 2024
- Published by Softaliza Tecnologias LTDA in Ibero-Latin American Congress on Computational Methods in Engineering (CILAMCE)
Open AccessInto the gray matter: construction and coupling of multiscale highly-detailed arterial networks in the human cerebral cortex
Stroke-related diseases represent 11% of worldwide deaths. State-of-the-art medical imaging describes many aspects of cerebral circulation. Nevertheless, the limited resolution of these techniques hinders the study of the hemodynamics in smaller vessels. Computational models aid in this problem, providing tools to characterize cerebral hemodynamics in clinical scenarios of interest that are otherwise inaccessible. This work aims to build vascular networks in the human cerebral cortex to study hemodynamics across different regions of the gray matter. The method is based on the Constrained Constructive Optimization method (CCO), called PDCCO, which generates vascular networks following a set of anatomical rules. A patient-specific MRI geometry of the cerebral gray matter is used to register an existing vascular model of the major cerebral vessels in the pial surface of the brain, from where the network is expanded. The brain geometry is partitioned into three territories for each large cerebral artery. The vascular generation is conducted independently for each territory and merged into a single network. First, a thin volume of the pial surface is filled with blood vessels down to the scale of penetrating arterioles of 50 μm. The network is further extended downwards to penetrate the gray matter, and deep vascularization is achieved by appending sub-tree networks to each terminal vessel. These sub-trees are generated separately with vascular properties associated with the gray matter. The final network reaches 234000 vascular segments in the pial network, out of which 116977 are terminal vessels. In turn, each terminal vessel gives rise to a network of 50 terminals, yielding 5 million terminals, and 10 million vascular segments, for each hemisphere. Over the pial surface, the diameters vary between 2100 μm and 26 μm, with terminals between 50 μm and 60 μm, and the pressure drops from 100 mmHg to a range between 50 mmHg and 70 mmHg. The network can be coupled with existing blood flow models of the entire cardiovascular system for the simulation of pulsatile blood flow to study pressure heterogeneities along the cerebral cortex in normal and pathological systemic conditions. This novel approach proposes a strategy for the automatic vascularization of the brain, with the aim of understanding microcirculation under different conditions, allowing the study of the risk of stroke, among other mechanisms involved in the onset and progress of degenerative diseases.