Paulo Crespo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulo Crespo has a total of 473 co-authors. Here are the top co-authors by number of shared publications:
- Hugo Simões
LIP - Laboratório de Instrumentação e Física Experimental de Partículas, University of Coimbra, 3004-516 Coimbra, Portugal
14 shared publications - Rui Ferreira Marques
LIP, Laboratório de Instrumentacão e Física Experimental de Partículas, 3004-516 Coimbra, Portugal
14 shared publications - Paulo Fonte
LIP -Laboratory of Instrumentation and Experimental Particle Physics Open Air Coimbra Portugal
12 shared publications W. Enghardt
11 shared publicationsJ. Pawelke
8 shared publications- Miguel Couceiro
Polytechnic University of Coimbra, Rua da Misericórdia, Lagar dos Cortiços, S. Martinho do Bispo, 3045-093 Coimbra, Portugal
7 shared publications
Latest Publications
- Open Access
- 26 April 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 20, 101318
Characterization of a Low-Energy Cyclotron-Based Proton Beam for Preclinical Radiobiological Studies
- 26 April 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 20, 101318
Open AccessCharacterization of a Low-Energy Cyclotron-Based Proton Beam for Preclinical Radiobiological Studies
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (Special ) , 49-54
First PET Studies of a FLASH Proton Beam: Summary and Future Prospects
Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect. Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics. Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam. Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities. Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (Special ) , 49-54
First PET Studies of a FLASH Proton Beam: Summary and Future Prospects
Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect. Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics. Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam. Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities. Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.
- Open Access
- 24 September 2024
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 2 (3) , 4099
Multislit gamma camera for external beam radiotherapy assistance: Experimental proof of concept
The orthogonal computed tomography (OrthoCT) concept, based on orthogonal ray imaging, is a low-dose imaging technique currently under investigation to potentially aid in external-beam radiation therapy treatments. This technique involves detecting radiation scattered within the patient and emitted at approximately 90° from the direction of the incoming beam. This scattered radiation can be collected by a 1D-detector system with a multisliced collimator positioned perpendicular to the incident beam axis. Such a system holds promise for on-board imaging with the patient positioned and prepared for treatment, as well as for real-time treatment monitoring. In this study, a multi-slice OrthoCT detector prototype was developed and tested under in-beam irradiation. The system utilizes gadolinium orthosilicate scintillator crystals coupled to photomultiplier tubes and a collimator made of lead slices. Experimental measurements were conducted using a heterogeneous phantom made of acrylic with an air cavity inside. The phantom was irradiated with a TrueBeam linac operating at 6 MV in the flattening-filter-free mode. The findings of this study indicate that this innovative imaging technique is capable of providing morphological images of the phantom. This accomplishment is achieved without the need to rotate the X-ray source around the object to be irradiated, demonstrating the feasibility of such a system.
- 24 September 2024
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 2 (3) , 4099
Open AccessMultislit gamma camera for external beam radiotherapy assistance: Experimental proof of concept
The orthogonal computed tomography (OrthoCT) concept, based on orthogonal ray imaging, is a low-dose imaging technique currently under investigation to potentially aid in external-beam radiation therapy treatments. This technique involves detecting radiation scattered within the patient and emitted at approximately 90° from the direction of the incoming beam. This scattered radiation can be collected by a 1D-detector system with a multisliced collimator positioned perpendicular to the incident beam axis. Such a system holds promise for on-board imaging with the patient positioned and prepared for treatment, as well as for real-time treatment monitoring. In this study, a multi-slice OrthoCT detector prototype was developed and tested under in-beam irradiation. The system utilizes gadolinium orthosilicate scintillator crystals coupled to photomultiplier tubes and a collimator made of lead slices. Experimental measurements were conducted using a heterogeneous phantom made of acrylic with an air cavity inside. The phantom was irradiated with a TrueBeam linac operating at 6 MV in the flattening-filter-free mode. The findings of this study indicate that this innovative imaging technique is capable of providing morphological images of the phantom. This accomplishment is achieved without the need to rotate the X-ray source around the object to be irradiated, demonstrating the feasibility of such a system.
- Open Access
- 23 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235004
The first probe of a FLASH proton beam by PET
The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam. A small positron emission tomography (PET) system was exposed in an ocular beam of the Proton Therapy Center at MD Anderson Cancer Center to view phantoms irradiated by 3.5 × 10 10 protons with a kinetic energy of 75.8 MeV delivered in 101.5 ms-long spills yielding a dose rate of 164 Gy s −1 . Most in-spill events were due to prompt gammas. Reconstructed post-spill tomographic events, recorded for up to 20 min, yielded quantitative imaging and dosimetric information. These findings open a new and novel modality for imaging and monitoring of FLASH proton therapy exploiting in-spill prompt gamma imaging followed by post-spill PET imaging.
- 23 November 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (23) , 235004
Open AccessThe first probe of a FLASH proton beam by PET
The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam. A small positron emission tomography (PET) system was exposed in an ocular beam of the Proton Therapy Center at MD Anderson Cancer Center to view phantoms irradiated by 3.5 × 10 10 protons with a kinetic energy of 75.8 MeV delivered in 101.5 ms-long spills yielding a dose rate of 164 Gy s −1 . Most in-spill events were due to prompt gammas. Reconstructed post-spill tomographic events, recorded for up to 20 min, yielded quantitative imaging and dosimetric information. These findings open a new and novel modality for imaging and monitoring of FLASH proton therapy exploiting in-spill prompt gamma imaging followed by post-spill PET imaging.
- Open Access
- 7 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (12) , 125001
The first PET glimpse of a proton FLASH beam
We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.8 MeV and an intensity of about 3.5 × 10 10 protons that were extracted over 101.5 ms-long spills. The radiation environment was characterized by cadmium–zinc–telluride and plastic scintillator counters. Preliminary results indicate that the PET technology used in our tests can efficiently record FLASH beam events. The instrument yielded informative and quantitative imaging and dosimetry of beam-activated isotopes in a PMMA phantom, as supported by Monte Carlo simulations. These studies open a new PET modality that can lead to improved imaging and monitoring of FLASH proton therapy.
- 7 June 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (12) , 125001
Open AccessThe first PET glimpse of a proton FLASH beam
We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.8 MeV and an intensity of about 3.5 × 10 10 protons that were extracted over 101.5 ms-long spills. The radiation environment was characterized by cadmium–zinc–telluride and plastic scintillator counters. Preliminary results indicate that the PET technology used in our tests can efficiently record FLASH beam events. The instrument yielded informative and quantitative imaging and dosimetry of beam-activated isotopes in a PMMA phantom, as supported by Monte Carlo simulations. These studies open a new PET modality that can lead to improved imaging and monitoring of FLASH proton therapy.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (9) , 2063-2071
Orbit-Like Proton Radiation Sensitivity of CdTe Detectors: Evaluation of Mobility-Lifetime Products and Spectroscopic Properties
The present work reports the proton radiation sensitivity of two 1.0 mm thick EURORAD ohmic CdTe detectors, irradiated with low energy proton beam generated in a PET cyclotron facility. The CdTe crystals were exposed to a proton radiation field composed by energies of ≈13.8, ≈9.7, ≈5.7 and ≈3.3 MeV, at an average flux ~108 protons cm-2 s-1, with total fluence from ≈2.1X109 up to ≈4.5X1010 protons cm-2. average dose from ≈5.9 up to ≈130 Gy, equivalent to the proton fluence accumulated in ~1 up to ~20 years in a Low-Earth Orbit (LEO). The impact of the proton radiation field was analyzed through the charge transport properties. the mobility-lifetime product for electrons, (μτ)e, and holes, (μτ)h, and the spectroscopic properties. the energy resolution and the peak-to-valley ratio, for γ-ray lines within 60.662 keV. The tested CdTe detectors, with (μτ)e~5X10-4 cm2 V-1 and (μτ)h~3X10-5 cm2 V-1, showed good radiation hardness, being measured upper-limit of (μτ)e and (μτ)h proton fluence (average dose) sensitivity ~2X10-15 cm2 V-1/protons cm-2 (~7X10-7 cm2 V-1/Gy) and ~X10-16 cm2 V-1/protons cm-2 (~1X10-7 cm2 V-1/Gy), respectively. Up to ≈130 Gy, no significant degradation of the energy resolution and the peak-to-valley ratio was observed.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (9) , 2063-2071
Orbit-Like Proton Radiation Sensitivity of CdTe Detectors: Evaluation of Mobility-Lifetime Products and Spectroscopic Properties
The present work reports the proton radiation sensitivity of two 1.0 mm thick EURORAD ohmic CdTe detectors, irradiated with low energy proton beam generated in a PET cyclotron facility. The CdTe crystals were exposed to a proton radiation field composed by energies of ≈13.8, ≈9.7, ≈5.7 and ≈3.3 MeV, at an average flux ~108 protons cm-2 s-1, with total fluence from ≈2.1X109 up to ≈4.5X1010 protons cm-2. average dose from ≈5.9 up to ≈130 Gy, equivalent to the proton fluence accumulated in ~1 up to ~20 years in a Low-Earth Orbit (LEO). The impact of the proton radiation field was analyzed through the charge transport properties. the mobility-lifetime product for electrons, (μτ)e, and holes, (μτ)h, and the spectroscopic properties. the energy resolution and the peak-to-valley ratio, for γ-ray lines within 60.662 keV. The tested CdTe detectors, with (μτ)e~5X10-4 cm2 V-1 and (μτ)h~3X10-5 cm2 V-1, showed good radiation hardness, being measured upper-limit of (μτ)e and (μτ)h proton fluence (average dose) sensitivity ~2X10-15 cm2 V-1/protons cm-2 (~7X10-7 cm2 V-1/Gy) and ~X10-16 cm2 V-1/protons cm-2 (~1X10-7 cm2 V-1/Gy), respectively. Up to ≈130 Gy, no significant degradation of the energy resolution and the peak-to-valley ratio was observed.
- Open Access
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 1-14
Simulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta
- 1 October 2018
- Published by Elsevier in Physica Medica
- Vol. 54, 1-14
Open AccessSimulation of proton range monitoring in an anthropomorphic phantom using multi-slat collimators and time-of-flight detection of prompt-gamma quanta
- Open Access
- 14 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (5) , 510-519
Optimization of the Signal-to-Background Ratio in Prompt Gamma Imaging Using Energy and Shifting Time-of-Flight Discrimination: Experiments With a Scanning Parallel-Slit Collimator
Much attention is currently being paid to imaging prompt gamma (PG) rays for in vivo proton range monitoring in proton therapy. PG imaging using a collimator is affected by neutron-related background. We study the effectiveness of background reduction experimentally, using a scanning parallel-slit PG collimator as a simplified model of a multislat PG camera. The analysis is focused on the falloff region of the PG intensity profile near the Bragg peak, which is the typical region of interest for proton range estimation. Background reduction was studied for different energy windows, with and without a shifting time-of-flight window that takes into account the proton velocity within the phantom. Practical methods are put forward that apply to cyclotron-based pencil beams. The parallel-slit collimator was placed in front of arrays of cerium-doped lutetium yttrium silicate-coupled digital silicon photomultipliers, used to measure energy and time spectra together with intensity profiles of prompt events emitted from a polymethylmethacrylate phantom irradiated with a 160-MeV proton pencil beam. The best signal-to-background ratio of ~1.6 was similar to that obtained previously with a knife-edge-slit collimator. However, the slope-over-noise ratio in the PG-profile falloff region, was ~1.2 higher for the present collimator, given its better resolution.
- 14 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (5) , 510-519
Open AccessOptimization of the Signal-to-Background Ratio in Prompt Gamma Imaging Using Energy and Shifting Time-of-Flight Discrimination: Experiments With a Scanning Parallel-Slit Collimator
Much attention is currently being paid to imaging prompt gamma (PG) rays for in vivo proton range monitoring in proton therapy. PG imaging using a collimator is affected by neutron-related background. We study the effectiveness of background reduction experimentally, using a scanning parallel-slit PG collimator as a simplified model of a multislat PG camera. The analysis is focused on the falloff region of the PG intensity profile near the Bragg peak, which is the typical region of interest for proton range estimation. Background reduction was studied for different energy windows, with and without a shifting time-of-flight window that takes into account the proton velocity within the phantom. Practical methods are put forward that apply to cyclotron-based pencil beams. The parallel-slit collimator was placed in front of arrays of cerium-doped lutetium yttrium silicate-coupled digital silicon photomultipliers, used to measure energy and time spectra together with intensity profiles of prompt events emitted from a polymethylmethacrylate phantom irradiated with a 160-MeV proton pencil beam. The best signal-to-background ratio of ~1.6 was similar to that obtained previously with a knife-edge-slit collimator. However, the slope-over-noise ratio in the PG-profile falloff region, was ~1.2 higher for the present collimator, given its better resolution.
- Open Access
Fast full-body reconstruction for a functional human RPC-PET imaging system using list-mode simulated data and its applicability to radiation oncology and radiology
Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly about providing a reconstruction solution to such whole-body single-bed data collection on an event-by-event basis. We demonstrate a fully three-dimensional time-of-flight (TOF)-based reconstruction algorithm that is capable of processing the highly inclined lines of response acquired from a system with a very large axial field of view, such as those used in RPC-PET. Such algorithm must be sufficiently fast that it will not compromise the clinical workflow of an RPC-PET system. We present simulation results from a voxelized version of the anthropomorphic NCAT phantom, with oncological lesions introduced into critical regions within the human body. The list-mode data was reconstructed with a TOF-weighted maximum-likelihood expectation maximization (MLEM). To accelerate the reconstruction time of the algorithm, a multi-threaded approach supported by graphical processing units (GPUs) was developed. Additionally, a TOF-assisted data division method is suggested that allows the data from nine body regions to be reconstructed independently and much more rapidly. The application of a TOF-based scatter rejection method reduces the overall body scatter from 57.1% to 32.9%. The results also show that a 300-ps FWHM RPC-PET scanner allows for the production of a reconstructed image in 3.5 minutes following a 7-minute acquisition upon the injection of 2 mCi of activity (146 M coincidence events). We present for the first time a full realistic reconstruction of a whole body, long axial coverage, RPC-PET scanner. We demonstrate clinically relevant reconstruction times comparable (or lower) to the patient acquisition times on both multi-threaded CPU and GPU.
Open AccessFast full-body reconstruction for a functional human RPC-PET imaging system using list-mode simulated data and its applicability to radiation oncology and radiology
Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly about providing a reconstruction solution to such whole-body single-bed data collection on an event-by-event basis. We demonstrate a fully three-dimensional time-of-flight (TOF)-based reconstruction algorithm that is capable of processing the highly inclined lines of response acquired from a system with a very large axial field of view, such as those used in RPC-PET. Such algorithm must be sufficiently fast that it will not compromise the clinical workflow of an RPC-PET system. We present simulation results from a voxelized version of the anthropomorphic NCAT phantom, with oncological lesions introduced into critical regions within the human body. The list-mode data was reconstructed with a TOF-weighted maximum-likelihood expectation maximization (MLEM). To accelerate the reconstruction time of the algorithm, a multi-threaded approach supported by graphical processing units (GPUs) was developed. Additionally, a TOF-assisted data division method is suggested that allows the data from nine body regions to be reconstructed independently and much more rapidly. The application of a TOF-based scatter rejection method reduces the overall body scatter from 57.1% to 32.9%. The results also show that a 300-ps FWHM RPC-PET scanner allows for the production of a reconstructed image in 3.5 minutes following a 7-minute acquisition upon the injection of 2 mCi of activity (146 M coincidence events). We present for the first time a full realistic reconstruction of a whole body, long axial coverage, RPC-PET scanner. We demonstrate clinically relevant reconstruction times comparable (or lower) to the patient acquisition times on both multi-threaded CPU and GPU.