Chengjun Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengjun Xia has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Zibin Chi
2 shared publicationsChengxiang Li
School of Electric Power, South China University of Technology Guangzhou People's Republic of China
1 shared publicationFaisal Shehzad
Department of Computer Science, COMSATS University Islamabad, Islamabad, Pakistan
1 shared publicationHaiwen Lan
Shaoguan Electric Power Supply Bureau, Guangdong Power Grid Company Shaoguan People's Republic of China
1 shared publicationHira Gul
Department of Computer Science, COMSATS University Islamabad, Islamabad, Pakistan
1 shared publication- Lin Guan
School of Electric Power, South China University of Technology, Guangzhou 510641, China
1 shared publication
Latest Publications
- Open Access
- 13 May 2025
- Published by Kambohwell Publisher Enterprises in International journal of Engineering Works
- Vol. 12 (05) , 66-72
Li-Ion Battery Capacity and State-of-Health Prediction through Novel Kolmogorov-Arnold Networks (KANs)
Li-Ion Battery Capacity and State-of-Health Prediction through Novel Kolmogorov-Arnold Networks (KANs)
- 13 May 2025
- Published by Kambohwell Publisher Enterprises in International journal of Engineering Works
- Vol. 12 (05) , 66-72
Open AccessLi-Ion Battery Capacity and State-of-Health Prediction through Novel Kolmogorov-Arnold Networks (KANs)
Li-Ion Battery Capacity and State-of-Health Prediction through Novel Kolmogorov-Arnold Networks (KANs)
- 27 March 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 231
A parameter-free fault location method for cross-bonding cable based on ranging equations
- 27 March 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 231
A parameter-free fault location method for cross-bonding cable based on ranging equations
- Open Access
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 98679-98700
Using GANCNN and ERNET for Detection of Non Technical Losses to Secure Smart Grids
In this paper, two supervised learning models based solutions are proposed for Electricity Theft Detection (ETD). In the first solution, Adaptive Synthetic Edited Nearest Neighbor (ADASYNENN) is used to solve class imbalanced problem. For feature extraction, Locally Linear Embedding (LLE) technique is utilized. Moreover, Self-Attention Generative Adversarial Network (SAGAN) is used in combination with Convolutional Neural Network (CNN) for the classification of electricity consumers. In the second solution, Synthetic Minority Oversampling Technique Edited Nearest Neighbor (SMOTEENN) is proposed. Moreover, a novel classification model, named as ERNET, which is based on EfficientNet, Residual Network (ResNet) and Gated Recurrent Unit (GRU), is used to detect Non-Technical Losses (NTLs). We also used a Sparse Auto Encoder (SAE) for effective feature extraction that makes the classification more robust and easy. Furthermore, a robust Root Mean Square Propagation (RMSProp) optimizer is used to improve the learning rate of the model. To validate the proposed models, simulations are performed using different performance metrics, such as precision, recall, F1-score, Area Under the Curve (AUC), FPR and Root Mean Square Error (RMSE). All simulations are performed using State Grid Corporation of China (SGCC) dataset. The proposed models are compared with benchmark models, such as SAGAN, Wide and Deep Convolutional Neural Network (WDCNN), CNN and Long Short Term Memory (LSTM). The simulation results prove that the proposed models outperform the existing models in terms of the aforementioned performance metrics.
- 25 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 98679-98700
Open AccessUsing GANCNN and ERNET for Detection of Non Technical Losses to Secure Smart Grids
In this paper, two supervised learning models based solutions are proposed for Electricity Theft Detection (ETD). In the first solution, Adaptive Synthetic Edited Nearest Neighbor (ADASYNENN) is used to solve class imbalanced problem. For feature extraction, Locally Linear Embedding (LLE) technique is utilized. Moreover, Self-Attention Generative Adversarial Network (SAGAN) is used in combination with Convolutional Neural Network (CNN) for the classification of electricity consumers. In the second solution, Synthetic Minority Oversampling Technique Edited Nearest Neighbor (SMOTEENN) is proposed. Moreover, a novel classification model, named as ERNET, which is based on EfficientNet, Residual Network (ResNet) and Gated Recurrent Unit (GRU), is used to detect Non-Technical Losses (NTLs). We also used a Sparse Auto Encoder (SAE) for effective feature extraction that makes the classification more robust and easy. Furthermore, a robust Root Mean Square Propagation (RMSProp) optimizer is used to improve the learning rate of the model. To validate the proposed models, simulations are performed using different performance metrics, such as precision, recall, F1-score, Area Under the Curve (AUC), FPR and Root Mean Square Error (RMSE). All simulations are performed using State Grid Corporation of China (SGCC) dataset. The proposed models are compared with benchmark models, such as SAGAN, Wide and Deep Convolutional Neural Network (WDCNN), CNN and Long Short Term Memory (LSTM). The simulation results prove that the proposed models outperform the existing models in terms of the aforementioned performance metrics.
- Open Access
- 23 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (17) , 4002-4008
Frequency regulation strategy based on variable‐parameter frequency limit control during black start
High‐voltage direct current (HVDC) can speed up the recovery of a power system. However, both rectifier and inverter sides of HVDC are weak systems during a black start. To coordinate frequency characteristics of both sides within the frequency deviation constraint, a frequency regulation strategy based on variable‐parameter frequency limit control (FLC) during a black start is proposed. First, the mathematical models of asynchronous interconnected AC–DC system are established, and the optimal FLC parameters leading to minimum frequency deviation of both sides are obtained. Subsequently, based on the characteristics of the optimal FLC parameters with the parameters of the equivalent generator and the capacity of the AC system, a frequency regulation strategy is proposed to adapt to the continuously changing parameters and configurations of the AC power system during a black start. Finally, the simulation model is established using PSCAD/EMTDC software to verify the control strategy and the correctness of the optimal FLC parameters.
- 23 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (17) , 4002-4008
Open AccessFrequency regulation strategy based on variable‐parameter frequency limit control during black start
High‐voltage direct current (HVDC) can speed up the recovery of a power system. However, both rectifier and inverter sides of HVDC are weak systems during a black start. To coordinate frequency characteristics of both sides within the frequency deviation constraint, a frequency regulation strategy based on variable‐parameter frequency limit control (FLC) during a black start is proposed. First, the mathematical models of asynchronous interconnected AC–DC system are established, and the optimal FLC parameters leading to minimum frequency deviation of both sides are obtained. Subsequently, based on the characteristics of the optimal FLC parameters with the parameters of the equivalent generator and the capacity of the AC system, a frequency regulation strategy is proposed to adapt to the continuously changing parameters and configurations of the AC power system during a black start. Finally, the simulation model is established using PSCAD/EMTDC software to verify the control strategy and the correctness of the optimal FLC parameters.
- Open Access
Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
The multi-infeed interaction factor (MIIF) is used extensively in indicating the degree of interaction among high-voltage direct current (HVDC) converters and is currently calculated by simulation methods according to the definition, or by using the equivalent impedance ratio method. The first method is an experimental calculation method and the second method does not account for the effects of HVDC control modes. An analytical calculation method for MIIF considering control modes of HVDC links is proposed in this paper. First, the voltage variation of converter bus in the context of small disturbance is equated by using the bus impedance matrix. In this way the equations for the solution of MIIF considering HVDC control mode are obtained. Subsequently, based on two rational assumptions, the practical analytical calculation expression of MIIF is deduced in detail. The MIIF calculation method proposed in this paper is an improvement of the equivalent impedance ratio method and reflects the main influencing factors of voltage interaction including HVDC control modes. Moreover, the derived analytical expression can give a fundamental insight into parameter dependencies of voltage interaction. Finally, the validity and accuracy of the proposed approach are demonstrated in both dual-infeed HVDC system and actual large-scale power grid.
Open AccessAnalytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
The multi-infeed interaction factor (MIIF) is used extensively in indicating the degree of interaction among high-voltage direct current (HVDC) converters and is currently calculated by simulation methods according to the definition, or by using the equivalent impedance ratio method. The first method is an experimental calculation method and the second method does not account for the effects of HVDC control modes. An analytical calculation method for MIIF considering control modes of HVDC links is proposed in this paper. First, the voltage variation of converter bus in the context of small disturbance is equated by using the bus impedance matrix. In this way the equations for the solution of MIIF considering HVDC control mode are obtained. Subsequently, based on two rational assumptions, the practical analytical calculation expression of MIIF is deduced in detail. The MIIF calculation method proposed in this paper is an improvement of the equivalent impedance ratio method and reflects the main influencing factors of voltage interaction including HVDC control modes. Moreover, the derived analytical expression can give a fundamental insight into parameter dependencies of voltage interaction. Finally, the validity and accuracy of the proposed approach are demonstrated in both dual-infeed HVDC system and actual large-scale power grid.