  • Non‐Invasive Methods for Identifying Electrical Responders to Conduction System Pacing Cardiac Resynchronization Therapy

    by Jack W. Samways, Nadine Ali, Ahran D. Arnold, Ji‐Jian Chow, Matthew Shun‐Shin, Jagdeep Singh Mohal, Akriti Naraen, Keenan Saleh, Nandita Kaza, Chetanya Sharma, et al.

    Background: Conduction system pacing (CSP) is an emerging alternative modality of cardiac resynchronization therapy (CRT). However, not all patients obtain electrical resynchronization with CSP, there is a clinical need for reliable non‐invasive predictors of response. We aimed to assess the ability of several non‐invasive modalities to predict electrical resynchronization with CSP‐CRT. Methods: Patients with standard heart failure CRT indications (excluding right‐bundle branch block) underwent CSP‐CRT using His‐bundle and left‐bundle branch pacing. Electrical resynchronization was defined as a >10 ms reduction in left ventricular activation time or conversion to a physiological left ventricular activation pattern on non‐invasive multi‐electrode mapping. We assessed whether 12‐lead ECG morphology, vector electrocardiogram (VCG) derived QRS area, Ultra High Frequency (UHF)‐ECG parameters or MRI scar burden predicted electrical resynchronization. Results: Thirty four patients were analyzed (mean age 69±10 years; 82% male; LVEF 30±6%; QRS duration 161±23 ms; 32% ischemic cardiomyopathy). Electrical resynchronization was achieved in 24/34 (71%; 95%CI 53–85). Strauss criteria positivity on 12‐lead ECG yielded a positive predictive value (PPV) of 83% (95%CI 61–95%) and negative predictive value (NPV) of 55% (95%CI 23–83%). VCG QRS area >100µVs demonstrated PPV 100% (95% CI 81–100%) and NPV 73% (95%CI 85–100%). UHF‐ECG e‐DYS >50 ms gave PPV 93% (95%CI 66–100%) and NPV 47% (23%–72%); >60 ms gave PPV 90% (95%CI 66–100%) and NPV 38% (95%CI 18–62%). MRI scar burden <15% resulted in PPV 88% (95%CI 64–99%) and NPV 56% (95%CI 21–86%). Lines of propagation discontinuity on multi‐electrode mapping showed PPV 100% (95%CI 85–100%) and NPV 83% (95%CI 52–98%). Conclusions: Multiple non‐invasive markers, including QRS morphology, VCG QRS area, UHF‐ECG e‐DYS, MRI scar burden showed potential to identify patients who are likely to electrically resynchronize with CSP‐CRT, although their NPVs were generally modest. Non‐invasive propagation mapping had the highest PPV and NPV.

  • Tau20-RETROmapping System Identifies Driver-Like Activation Patterns in Real-Time During Persistent Atrial Fibrillation

    by Oliver Jones, Nick Linton, Stewart Bissett, Simos Koutsoftidis, Jamie Kay, Huiyi Wu, Ji-Jian Chow, Norman Qureshi, Tina Baykaner, Junaid Zaman, et al.

    BACKGROUND: Conventional activation mapping of atrial fibrillation (AF) during clinical procedures is limited by low-amplitude, fractionated electrograms and cycle length variability. The Tau20-RETROmapping stimulator-recorder system (TauRhythm Therapies, United Kingdom) is an investigational device used to identify nonpulmonary vein AF drivers by real-time, high-density activation mapping of uniform wavefronts during AF. We validated the accuracy of the system and applied it to left atrial mapping for evidence of AF drivers. METHODS: Left atrial geometry was acquired using a 3-dimensional electroanatomic mapping system with high-density mapping catheters (CARTO 3 with Optrell, or EnSite X with HD Grid). Electrograms were recorded for 30 seconds at multiple left atrial sites. The Tau20-RETROmapping system generates activation maps of organized wavefronts. System performance was manually validated against randomly sampled local electrograms using a grid sweep of thresholds to identify Pareto-optimal parameters in sinus rhythm, atrial pacing, atrial tachycardia (AT), and AF. The system was then applied to identify putative driver activation patterns during persistent AF. RESULTS: We studied 24 patients undergoing pulmonary vein isolation for AF. Six patients presented in sinus rhythm or AT, in whom the system demonstrated a sensitivity of 100.0% (95% CI, 80.5%–100.0%) and a specificity of 100.0% (85.2%–100.0%). Eighteen patients were mapped in AF: the system had a sensitivity of 94.4% (86.2%–98.4%) and a specificity of 97.1% (89.9%–99.6%) when identifying organized AF wavefronts, and accurately identified the earliest activation in 89.6% (79.7%–95.7%) of waves. Stable propagation originating from the left atrial appendage (LAA) was observed in 3/18 patients, while 8/18 demonstrated competing propagation toward and away from the LAA. Conduction away from the LAA was detected along the anterior (8/18 patients), lateral (8/18 patients), and posterior (7/18 patients) walls. No propagation near the LAA was observed in 6/18 patients. CONCLUSIONS: The Tau20-RETROmapping system enables real-time activation mapping of AF, with the most convincing driver-like areas being identified around the LAA.

  • Top Cited Papers
    Open Access

    Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)

    by Frédéric Sacher, Andrea Sarkozy, Helmut Pürerfellner, Alexandra Steyer, Jonathan Lyne, Charlène Coquard, Romain Tixier, Nicolas Combes, Michel Haissaguerre, Michalis Efremidis, et al.

    Aims: The feasibility and safety of the lattice-tip catheter for ventricular arrhythmia (VA) ablation in humans remain largely unknown. This study aimed to assess feasibility, safety profile as well as patient outcomes after VA ablation with a lattice-tip catheter in a multicentre European registry. Methods and results: All 18 European centres using the AFFERA system in September 2024 agreed to participate. Clinical, procedural, and follow-up data (minimum 3 months) were systematically collected and analysed. A total of 126 patients (18% female; mean age 59 ± 16 years) underwent VA ablation using the lattice-tip catheter during the inclusion period. Ablation indications included ventricular tachycardia (VT) in 99, premature ventricular complexes (PVCs) in 23, and ventricular fibrillation (VF) in 4 patients. Major and minor acute complications were observed in 7 (6%) and 18 (14%) procedures, respectively. They included thrombo-embolic event (n = 2), major bleeding (n = 2), ventricular fibrillation induction (n = 1), tamponade due to epicardial access (n = 1), and cardiogenic shock due to prolonged VT mapping (n = 1). Within the first month post-procedure, three patients died [from multi-organ failure (n = 2) and sepsis (n = 1)], two had worsening heart failure, one myocardial infarction, one sepsis, and one major gastro-intestinal bleeding. After a mean follow-up of 5.6 ± 3.7 months, absence of recurrence was 78% for PVC, 70% for VT, and 100% for VF. Conclusion: In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe. In the absence of large, randomized trials, exhaustive registry is of key importance to ensure safety and efficacy of new catheter technologies.


  • Open Access

    Therapeutic potential of conduction system pacing as a method for improving cardiac output during ventricular tachycardia

    by Daniel Keene, Alejandra A. Miyazawa, Ahran D. Arnold, Akriti Naraen, Nandita Kaza, Jagdeep S. Mohal, David C. Lefroy, Phang Boon Lim, Fu Siong Ng, Michael Koa-Wing, et al.

    Background: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. Methods: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. Results: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. Conclusions: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment. Graphical

  • Open Access

    Catheter Ablation for Ventricular Tachycardia After MI: A Reconstructed Individual Patient Data Meta-analysis of Randomised Controlled Trials

    by Rohin K Reddy, James P Howard, Yousif Ahmad, Matthew J Shun-Shin, Florentina A Simader, Alejandra A Miyazawa, Keenan Saleh, Akriti Naraen, Jack W Samways, George Katritsis, et al.

    Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41–0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67–1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.


  • Open Access

    Left bundle branch pacing with and without anodal capture: impact on ventricular activation pattern and acute haemodynamics

    by Nadine Ali, Khulat Saqi, Ahran D Arnold, Alejandra A Miyazawa, Daniel Keene, Ji-Jian Chow, Ian Little, Nicholas S Peters, Prapa Kanagaratnam, Norman Qureshi, et al.

    Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference −0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


  • Open Access

    Smartphone-Based Remote Monitoring in Heart Failure With Reduced Ejection Fraction: Retrospective Cohort Study of Secondary Care Use and Costs

    by Sameer Zaman, Yorissa Padayachee, Moulesh Shah, Jack Samways, Alice Auton, Nicholas M Quaife, Mark Sweeney, James P Howard, Indira Tenorio, Patrik Bachtiger, et al.

    Background: Despite effective therapies, the economic burden of heart failure with reduced ejection fraction (HFrEF) is driven by frequent hospitalizations. Treatment optimization and admission avoidance rely on frequent symptom reviews and monitoring of vital signs. Remote monitoring (RM) aims to prevent admissions by facilitating early intervention, but the impact of noninvasive, smartphone-based RM of vital signs on secondary health care use and costs in the months after a new diagnosis of HFrEF is unknown. Objective: The purpose of this study is to conduct a secondary care health use and health-economic evaluation for patients with HFrEF using smartphone-based noninvasive RM and compare it with matched controls receiving usual care without RM. Methods: We conducted a retrospective study of 2 cohorts of newly diagnosed HFrEF patients, matched 1:1 for demographics, socioeconomic status, comorbidities, and HFrEF severity. They are (1) the RM group, with patients using the RM platform for >3 months and (2) the control group, with patients referred before RM was available who received usual heart failure care without RM. Emergency department (ED) attendance, hospital admissions, outpatient use, and the associated costs of this secondary care activity were extracted from the Discover data set for a 3-month period after diagnosis. Platform costs were added for the RM group. Secondary health care use and costs were analyzed using Kaplan-Meier event analysis and Cox proportional hazards modeling. Results: A total of 146 patients (mean age 63 years; 42/146, 29% female) were included (73 in each group). The groups were well-matched for all baseline characteristics except hypertension (P=.03). RM was associated with a lower hazard of ED attendance (hazard ratio [HR] 0.43; P=.02) and unplanned admissions (HR 0.26; P=.02). There were no differences in elective admissions (HR 1.03, P=.96) or outpatient use (HR 1.40; P=.18) between the 2 groups. These differences were sustained by a univariate model controlling for hypertension. Over a 3-month period, secondary health care costs were approximately 4-fold lower in the RM group than the control group, despite the additional cost of RM itself (mean cost per patient GBP £465, US $581 vs GBP £1850, US $2313, respectively; P=.04). Conclusions: This retrospective cohort study shows that smartphone-based RM of vital signs is feasible for HFrEF. This type of RM was associated with an approximately 2-fold reduction in ED attendance and a 4-fold reduction in emergency admissions over just 3 months after a new diagnosis with HFrEF. Costs were significantly lower in the RM group without increasing outpatient demand. This type of RM could be adjunctive to standard care to reduce admissions, enabling other resources to help patients unable to use RM.


  • Open Access

    Smartphone-Based Remote Monitoring for Chronic Heart Failure: Mixed Methods Analysis of User Experience From Patient and Nurse Perspectives

    by Alice Auton, Sameer Zaman, Yorissa Padayachee, Jack W Samways, Nicholas M Quaife, Mark Sweeney, Indira Tenorio, Nick W F Linton, Graham D Cole, Nicholas S Peters, et al.

    Background: Community-based management by heart failure specialist nurses (HFSNs) is key to improving self-care in heart failure with reduced ejection fraction. Remote monitoring (RM) can aid nurse-led management, but in the literature, user feedback evaluation is skewed in favor of the patient rather than nursing user experience. Furthermore, the ways in which different groups use the same RM platform at the same time are rarely directly compared in the literature. We present a balanced semantic analysis of user feedback from patient and nurse perspectives of Luscii, a smartphone-based RM strategy combining self-measurement of vital signs, instant messaging, and e-learning. Objective: This study aims to (1) evaluate how patients and nurses use this type of RM (usage type), (2) evaluate patients’ and nurses’ user feedback on this type of RM (user experience), and (3) directly compare the usage type and user experience of patients and nurses using the same type of RM platform at the same time. Methods: We performed a retrospective usage type and user experience evaluation of the RM platform from the perspective of both patients with heart failure with reduced ejection fraction and the HFSNs using the platform to manage them. We conducted semantic analysis of written patient feedback provided via the platform and a focus group of 6 HFSNs. Additionally, as an indirect measure of tablet adherence, self-measured vital signs (blood pressure, heart rate, and body mass) were extracted from the RM platform at onboarding and 3 months later. Paired 2-tailed t tests were used to evaluate differences between mean scores across the 2 timepoints. Results: A total of 79 patients (mean age 62 years; 35%, 28/79 female) were included. Semantic analysis of usage type revealed extensive, bidirectional information exchange between patients and HFSNs using the platform. Semantic analysis of user experience demonstrates a range of positive and negative perspectives. Positive impacts included increased patient engagement, convenience for both user groups, and continuity of care. Negative impacts included information overload for patients and increased workload for nurses. After the patients used the platform for 3 months, they showed significant reductions in heart rate (P=.004) and blood pressure (P=.008) but not body mass (P=.97) compared with onboarding. Conclusions: Smartphone-based RM with messaging and e-learning facilitates bilateral information sharing between patients and nurses on a range of topics. Patient and nurse user experience is largely positive and symmetrical, but there are possible negative impacts on patient attention and nurse workload. We recommend RM providers involve patient and nurse users in platform development, including recognition of RM usage in nursing job plans.


  • Open Access

    Ventricular Conduction Stability Noninvasively Identifies an Arrhythmic Substrate in Survivors of Idiopathic Ventricular Fibrillation

    by Ji‐Jian Chow, Kevin M. W. Leong, Matthew J. Shun‐Shin, Julian O. M. Ormerod, Michael Koa‐Wing, David C. Lefroy, Phang Boon Lim, Nicholas W. F. Linton, Fu Siong Ng, Norman A. Qureshi, et al.

    Background: Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise‐induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results: Computed tomography and exercise testing in patients wearing a 252‐electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P =0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3–1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise‐induced noise at comparable frequencies. Conclusions: In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.

  • Open Access

    Left bundle branch pacing with and without anodal capture: impact on ventricular activation pattern and acute hemodynamics

    by Nadine Ali, Khulat Saqi, Ahran D. Arnold, Alejandra A.Miyazawa, Daniel Keene, Ji-Jian Chow, Ian Little, Nicholas S. Peters, Prapa Kanagaratnam, Norman Qureshi, et al.

    Introduction Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. A proposed solution is to advance RV activation through anodal capture, but there is uncertainty regarding the mechanism by which early RV activation is achieved (capture of right bundle or RV myocardial capture) and it is not known whether this produces hemodynamic benefit. Methods We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R wave in lead V1. Ventricular activation pattern, timing and high precision acute hemodynamic response were studied during LBBP with and without anodal capture. Results We recruited 21 patients, mean age 67 years, 14 were males. We measured ECG timings and hemodynamics in all patients and in 15 we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that right ventricular septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration was shorter (116 ± 12ms versus 129 ± 14ms, p < 0.01), and total ventricular activation time was shorter (83 ± 18ms versus 90 ± 15ms, p = 0.01). This required higher outputs (3.6 ± 1.9V versus 0.6 ± 0.2V, p Conclusion Left bundle pacing with anodal capture advances right ventricular activation as a result of stimulation of the RV septal myocardium. However, this requires higher outputs and did not improve acute hemodynamics. Aiming for anodal capture may therefore not be necessary.