Aleksey V. Sukhanov
Aleksey V. Sukhanov has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Nataliya A. Gavrilenko
Department of Analytical Chemistry, Tomsk State University, 634050 Tomsk, Russia
5 shared publications - Nadezhda V. Saranchina
Department of Analytical Chemistry, Tomsk State University, 634050 Tomsk, Russia
4 shared publications - Mikhail A. Gavrilenko
Department of Chemical engineering, Tomsk Polytechnic University, 634050 Tomsk, Russia
2 shared publications - Mikhail Alekseevich Proskurnin
Analytical Chemistry Division, Chemistry Department, M.V. Lomonosov Moscow State University, 119991 Moscow, Russia
2 shared publications Anastasia Ovsyannikova
1 shared publication- Axel Duerkop
Institute of Analytical Chemistry Chemo‐ and Biosensors University of Regensburg Universitätsstraße 31 93053 Regensburg Bavaria Germany
1 shared publication
Latest Publications
- Open Access
- 12 July 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (7) , 177
Optical pH Sensing in Milk: A Small Puzzle of Indicator Concentrations and the Best Detection Method
Optical chemical sensors can yield distinctively different responses that are dependent on the method applied for readout and evaluation. We therefore present a comprehensive study on the pH determined non-continuously with optical sensors in real milk samples by either photometry or colorimetry (via the RGB-readout of digital images) compared to the pH values obtained electrochemically by potentiometry. Additionally, the photometric determination of pH was conducted with single-wavelength and a dual wavelength ratiometric evaluation of the absorbance. It was found that both the precision and accuracy of the pH determined by photometry benefit from lower concentrations of bromocresol purple, which served as the pH indicator inside the sensor membrane. A further improvement is obtained by the ratiometric evaluation of the photometric sensor response. The pH values obtained from the colorimetric evaluation, however, gain in precision and accuracy if a higher concentration of the indicator is immobilized inside the sensor membrane. This has a major impact on the future fabrication of optical pH sensor membranes because they can be better tuned to match to the most precise and accurate range of the planned detection method.
- 12 July 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (7) , 177
Open AccessOptical pH Sensing in Milk: A Small Puzzle of Indicator Concentrations and the Best Detection Method
Optical chemical sensors can yield distinctively different responses that are dependent on the method applied for readout and evaluation. We therefore present a comprehensive study on the pH determined non-continuously with optical sensors in real milk samples by either photometry or colorimetry (via the RGB-readout of digital images) compared to the pH values obtained electrochemically by potentiometry. Additionally, the photometric determination of pH was conducted with single-wavelength and a dual wavelength ratiometric evaluation of the absorbance. It was found that both the precision and accuracy of the pH determined by photometry benefit from lower concentrations of bromocresol purple, which served as the pH indicator inside the sensor membrane. A further improvement is obtained by the ratiometric evaluation of the photometric sensor response. The pH values obtained from the colorimetric evaluation, however, gain in precision and accuracy if a higher concentration of the indicator is immobilized inside the sensor membrane. This has a major impact on the future fabrication of optical pH sensor membranes because they can be better tuned to match to the most precise and accurate range of the planned detection method.
- 5 September 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (9) , 894-899
Kinetic Determination of Thiocyanate by the Reaction of Bromate with Crystal Violet Immobilized in a Polymethacrylate Matrix
A procedure is proposed for the kinetic solid-phase spectrophotometric determination of thiocyanate using a polymethacrylate matrix. The procedure is based on the Landolt reaction between...
- 5 September 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (9) , 894-899
Kinetic Determination of Thiocyanate by the Reaction of Bromate with Crystal Violet Immobilized in a Polymethacrylate Matrix
A procedure is proposed for the kinetic solid-phase spectrophotometric determination of thiocyanate using a polymethacrylate matrix. The procedure is based on the Landolt reaction between...
- 1 July 2018
- Published by OOO Zhurnal "Mendeleevskie Soobshcheniya" in Mendeleev Communications
- Vol. 28 (4) , 450-452
Reversible pH-sensitive element based on bromocresol purple immobilized into the polymethacrylate matrix
- 1 July 2018
- Published by OOO Zhurnal "Mendeleevskie Soobshcheniya" in Mendeleev Communications
- Vol. 28 (4) , 450-452
Reversible pH-sensitive element based on bromocresol purple immobilized into the polymethacrylate matrix
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 477-480
Polymethacrylate Matrix with Immobilized Acid–Base Indicators as pH Sensor
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 168, 477-480
Open AccessPolymethacrylate Matrix with Immobilized Acid–Base Indicators as pH Sensor
- 1 January 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 880, 19-24
Colorimetric Polymethacrylate Sensor
The paper describes a new colorimetric sensor. The colorimetric sensors were made of optically transparent polymethacrylate matrix with physically immobilized analytical reagent which is responsible for the extraction of the analyte into the sensing material and changing its color. The developed colorimetric sensor can be used in determination of various analytes using both solid-phase spectrophotometer and naked eye.
- 1 January 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 880, 19-24
Colorimetric Polymethacrylate Sensor
The paper describes a new colorimetric sensor. The colorimetric sensors were made of optically transparent polymethacrylate matrix with physically immobilized analytical reagent which is responsible for the extraction of the analyte into the sensing material and changing its color. The developed colorimetric sensor can be used in determination of various analytes using both solid-phase spectrophotometer and naked eye.
- 17 September 2013
- Published by Wiley in Chemistry – A European Journal
- Vol. 19 (44) , 14911-14917
A Highly K+‐Selective Phenylaza‐[18]crown‐6‐Lariat‐Ether‐Based Fluoroionophore and Its Application in the Sensing of K+ Ions with an Optical Sensor Film and in Cells
Herein, we report the synthesis of two phenylaza‐[18]crown‐6 lariat ethers with a coumarin fluorophore (1 and 2) and we reveal that compound 1 is an excellent probe for K+ ions under simulated physiological conditions. The presence of a 2‐methoxyethoxy lariat group at the ortho position of the anilino moiety is crucial to the substantially increased stability of compounds 1 and 2 over their lariat‐free phenylaza‐[18]crown‐6 ether analogues. Probe 1 shows a high K+/Na+ selectivity and a 2.5‐fold fluorescence enhancement was observed in the presence of 100 mM K+ ions. A fluorescent membrane sensor, which was prepared by incorporating probe 1 into a hydrogel, showed a fully reversible response, a response time of 150 s, and a signal change of 7.8 % per 1 mM K+ within the range 1–10 mM K+. The membrane was easily fabricated (only a single sensing layer on a solid polyester support), yet no leaching was observed. Moreover, compound 1 rapidly permeated into cells, was cytocompatible, and was suitable for the fluorescent imaging of K+ ions on both the extracellular and intracellular levels.
- 17 September 2013
- Published by Wiley in Chemistry – A European Journal
- Vol. 19 (44) , 14911-14917
A Highly K+‐Selective Phenylaza‐[18]crown‐6‐Lariat‐Ether‐Based Fluoroionophore and Its Application in the Sensing of K+ Ions with an Optical Sensor Film and in Cells
Herein, we report the synthesis of two phenylaza‐[18]crown‐6 lariat ethers with a coumarin fluorophore (1 and 2) and we reveal that compound 1 is an excellent probe for K+ ions under simulated physiological conditions. The presence of a 2‐methoxyethoxy lariat group at the ortho position of the anilino moiety is crucial to the substantially increased stability of compounds 1 and 2 over their lariat‐free phenylaza‐[18]crown‐6 ether analogues. Probe 1 shows a high K+/Na+ selectivity and a 2.5‐fold fluorescence enhancement was observed in the presence of 100 mM K+ ions. A fluorescent membrane sensor, which was prepared by incorporating probe 1 into a hydrogel, showed a fully reversible response, a response time of 150 s, and a signal change of 7.8 % per 1 mM K+ within the range 1–10 mM K+. The membrane was easily fabricated (only a single sensing layer on a solid polyester support), yet no leaching was observed. Moreover, compound 1 rapidly permeated into cells, was cytocompatible, and was suitable for the fluorescent imaging of K+ ions on both the extracellular and intracellular levels.
- 1 July 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (7) , 709-717
Solid Phase–Enhanced Photothermal Lensing with Mesoporous Polymethacrylate Matrices for Optical-Sensing Chemical Analysis
Procedures for the photothermal lens determination of metals and organic compounds, on the basis of solid-phase mesoporous optical-sensing materials (polymethacrylate [PMA]) matrices with immobilized reagents, were developed. These procedures combine (i) selective and efficient preconcentration of trace substances to be analyzed in specially designed and synthesized transparent mesoporous PMA plates; (ii) sensitive determination with the reliable and traceable photometric reactions previously developed for classical spectrophotometry; and (iii) the sensitivity enhancement of photothermal lens detection in polymers, which provides at least a ten-fold increase in sensitivity compared with solutions due to polymer thermo-optical properties (solid phase–enhanced thermal lensing). It is shown that the overall sensitivity of photothermal lens measurements in PMA matrices is two orders higher than photometric absorbance measurements for the same excitation source power, which is in good agreement with the expected theoretical sensitivity. Changes in the preparation of transparent PMA plates and analytical procedures for photothermal measurements compared with spectrophotometry are discussed. PMA matrices modified with various analytical reagents were applied to trace determination of Hg(II), Fe(II), Ag(I), Cu(II), and ascorbic acid, with subnanomolar to nanomolar limits of detection.
- 1 July 2013
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (7) , 709-717
Solid Phase–Enhanced Photothermal Lensing with Mesoporous Polymethacrylate Matrices for Optical-Sensing Chemical Analysis
Procedures for the photothermal lens determination of metals and organic compounds, on the basis of solid-phase mesoporous optical-sensing materials (polymethacrylate [PMA]) matrices with immobilized reagents, were developed. These procedures combine (i) selective and efficient preconcentration of trace substances to be analyzed in specially designed and synthesized transparent mesoporous PMA plates; (ii) sensitive determination with the reliable and traceable photometric reactions previously developed for classical spectrophotometry; and (iii) the sensitivity enhancement of photothermal lens detection in polymers, which provides at least a ten-fold increase in sensitivity compared with solutions due to polymer thermo-optical properties (solid phase–enhanced thermal lensing). It is shown that the overall sensitivity of photothermal lens measurements in PMA matrices is two orders higher than photometric absorbance measurements for the same excitation source power, which is in good agreement with the expected theoretical sensitivity. Changes in the preparation of transparent PMA plates and analytical procedures for photothermal measurements compared with spectrophotometry are discussed. PMA matrices modified with various analytical reagents were applied to trace determination of Hg(II), Fe(II), Ag(I), Cu(II), and ascorbic acid, with subnanomolar to nanomolar limits of detection.
- 10 June 2011
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 66 (6) , 623-628
Potentials of thermal lens spectroscopy for polymethacrylate optical sensors
The sensitivity of the earlier proposed procedures for the determination of iron(II, III) with 1,10-phenanthroline, silver(I) with dithizone, mercury with copper(II) dithizonate, copper(II) with lead...
- 10 June 2011
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 66 (6) , 623-628
Potentials of thermal lens spectroscopy for polymethacrylate optical sensors
The sensitivity of the earlier proposed procedures for the determination of iron(II, III) with 1,10-phenanthroline, silver(I) with dithizone, mercury with copper(II) dithizonate, copper(II) with lead...
- 5 January 2010
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 65 (1) , 17-20
Redox and acid-base properties of 2,6-dichlorophenolindophenol immobilized on a polymethacrylate matrix
The effect of the immobilization of 2,6-dichlorophenolindophenol ( DCIP) on a polymethacrylate matrix on its redox and acid-base properties was studied. The ionization constant and formal redox...
- 5 January 2010
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 65 (1) , 17-20
Redox and acid-base properties of 2,6-dichlorophenolindophenol immobilized on a polymethacrylate matrix
The effect of the immobilization of 2,6-dichlorophenolindophenol ( DCIP) on a polymethacrylate matrix on its redox and acid-base properties was studied. The ionization constant and formal redox...