MKMark Kempenaars

Mark Kempenaars

*This is an algorithmically generated author record based on publicly available information.

Mark Kempenaars has a total of 170 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Innovative lasers and polychromators for multi-wavelength real-time Thomson scattering in magnetic-confinement fusion devices

    by Eugene E. Mukhin, Sergey Yu. Tolstyakov, Gleb S. Kurskiev, Nikita V. Ermakov, Nikita S. Zhiltsov, Philip Ph. Forsh, Ekaterina E. Tkachenko, Valery A. Solovey, Sergey E. Aleksandrov, Andrey V. Nikolaev, et al.

  • Progress and challenges in the design of ITER’s polarimetric Thomson scattering diagnostic system

    by F. Bagnato, M. Bassan, A. Sirinelli, G. Vayakis, M. Kempenaars, L. Giudicotti, F. A. D’iSa

    Polarimetric Thomson scattering (PTS) is a technique that allows for accurate measurements of electron temperature (Te) in very hot plasmas (Te > 10 keV, a condition expected to be regularly achieved in ITER). Under such conditions, the spectral region spanned by the TS spectrum is large and extends to low wavelengths, where the transmission of the collection optics decreases, available detectors are less efficient, and the high level of plasma background light perturbs the measurements. This work presents the recent developments in the design of a PTS system for ITER, along with the challenges posed by the complex machine design. The system performance is assessed for an updated geometry (with respect to previous publication), showing that, with a scattering angle θscat = 167°, the expected signal is strongly reduced. Potential alternatives are analyzed: (1) a system employing a different laser injection position, allowing for a more favorable scattering angle and (2) a recently proposed dual-polarization laser pulse technique. The latter is evaluated for the possible ITER geometry, again showing that a more favorable scattering angle is needed for a robust performance.


  • Large-scale collecting mirrors for ITER optical diagnostic

    by Dmitry S Samsonov, Ivan Tereschenko, Eugene E Mukhin, Anna Gubal, Yuri Kapustin, Vladimir Filimonov, N A Babinov, Artem M Dmitriev, Andrey Nikolaev, Ivan Komarevtsev, et al.

    The challenges of large-scale mirror design for in-vessel collection system of ITER Divertor Thomson Scattering (DTS) are under consideration. These are the mirrors located out-of-line vision of fusion plasma (so called “second mirrors” i.e. not First Mirrors) with high-reflective Ag-based coating. The paper outlines: approaches providing optical surface shape and angular position stability; Ag coating applicability in nuclear irradiation, ITER in-vessel application and its resistance to Steam Ingress. Although, this assessment and the proposed solutions are considered in terms of ITER DTS compatibility, they may also appear to be of some use in other ITER diagnostics and in diagnostics of other fusion devices.


  • Residual Stress Monitoring for ITER Diagnostic Windows

    by Ramonika Sengupta, Mark Kempenaars, Govindarajan Jagannathan, Sunil Pak, Praghnesh Bhatt

    This article presents the measurement of residual stress distribution in ITER (“The Way” in Latin) diagnostics windows using a circular polariscope. The method being used is based on the measurement of the change in the state of polarization of a circularly polarized light after transmission/reflection from the stressed window under test. The theory based on Mueller calculus for the experimental setup has been presented. The measurement technique is validated for transmission mode by comparing the stress values measured for borosilicate glass (BK7) sample disks under diametrical compression with the theoretical values obtained using linear isotropic theory of elasticity. The method is, then, applied to an undamaged and a damaged ITER trial window, both in transmission and reflection modes, to observe the stress patterns inside the glass material and on the glass to metal seal. The major observations are that the undamaged window shows higher stress in majority of the cross section with lower stress values at localized regions. The glass near the seal shows high values of stress all along the circumference in case of the undamaged window. The damaged window that has got detached from the metal seal shows much lower stress values in majority of the cross section of the window with higher stress values in some regions. The region where the seal seems to have got detached from the glass shows lower values of stress at the seal location, and also the stress values in the glass near those locations are low. In conclusion, by observing the stress patterns inside the window, this technique helps determine the health of vacuum seal, and hence can be used in taking preventive measures.


  • Laser-induced fluorescence of helium ions in ITER divertor

    by A.V. Gorbunov, E.E. Mukhin, E.B. Berik, M.A. Melkumov, N.A. Babinov, G.S. Kurskiev, S.Yu. Tolstyakov, K.Yu. Vukolov, V.S. Lisitsa, M.G. Levashova, et al.


  • Nd:YAG lasers for ITER divertor Thomson scattering

    by A.F. Kornev, A.S. Davtian, A.S. Kovyarov, A.M. Makarov, D.O. Oborotov, V.P. Pokrovskii, A.A. Porozov, S.S. Sobolev, V.K. Stupnikov, G.S. Kurskiev, et al.


  • Integration of Thomson scattering and laser-induced fluorescence in ITER divertor

    by E.E. Mukhin, Gleb Sergeevich Kurskiev, Alexey Victorovich Gorbunov, Dmitry S Samsonov, Sergey Tolstyakov, Alexey Razdobarin, Nikita Babinov, Alexander N Bazhenov, Ivan Maximovich Bukreev, Artem M Dmitriev, et al.

    Divertor Thomson scattering (DTS) and Laser-induced Fluorescence (LIF) are both laser aided diagnostics well suited for combining with common probing and collecting optics that is the most sophisticated and expensive part of any ITER optical diagnostic. The combined DTS / LIF used for simultaneous measurement of local electron (Te, ne), ion (Ti, nHeII) and atom (nHeI, nH(D,T)) parameters provides the basic information on rates of electron and ion processes to have basic understanding of the physics of divertor plasma detachment. The measured parameters permit to calculate rates of ionization and recombination using Te, ne, Ti,, ni, nHeI, nH(D,T); emission intensity Te, ne, ni, nHeI, nH(D,T); frictional force of the plasma flow due to collisions with neutrals Ti, ni, T0, nHeI, nH(D,T) and pressure of the incoming plasma flow Te, ne, Ti, ni. The paper discusses the benefits of DTS and LIF integration, suggests new approaches to estimation of DTS capability, LIF implementation and ways of further diagnostic development.


  • Feasibility study of digital holography for erosion measurements under extreme environmental conditions inside the International Thermonuclear Experimental Reactor tokamak [invited]

    by Giancarlo Pedrini, Igor Alekseenko, Govindarajan Jagannathan, Mark Kempenaars, George Vayakis, Wolfgang Osten

    In the International Thermonuclear Experimental Reactor under construction in southern France, there will be a need for continuous measuring of the erosion at the wall, after the reactor starts operating. A two-wavelength interferometric technique based on digital holography is proposed for the erosion measurement. This technique has the ability to tackle the challenging environmental conditions within the reactor by a long-distance measurement, where a relay optic will be used for imaging the investigated surface on the detector. We will show that the shape measurements of objects located at a distance of more than 20 m from the measuring head can be carried out in a short time (100 μs) by the two-wavelength interferometric technique. A depth accuracy of ±10  μm is achieved.


  • First observation of the depolarization of Thomson scattering radiation by a fusion plasma

    by Leonardo Giudicotti, Mark Kempenaars, Oisín Brian McCormack, Joanne Flanagan, Roberto Pasqualotto, Jet Contributors

    We report the first experimental observation of the depolarization of the Thomson scattering (TS) radiation, a relativistic effect expected to occur in very high Te plasmas and never observed so far in a fusion machine. A set of unused optical fibers in the collection optics of the HRTS (High Resolution Thomson scattering) system of JET has been used to detect the depolarized TS radiation during a JET campaign with Te ≤ 8 keV. A linear polarizer with the axis perpendicular to the direction of the incident E-field was placed in front of a fiber optic pair observing a region close to the plasma core, while another fiber pair with no polariser simultaneously observed an adjacent plasma region. The measured intensity ratio was found to be consistent with the theory, taking into account sensitivity coefficients of the two measurement channels determined with post-experiment calibrations and Raman scattering. This depolarization effect is at the basis of polarimetric TS, a different and complementary method for the analysis of TS spectra that can provide significant advantages for Te measurements in very hot plasmas such as in ITER (Te ≤ 40 keV).


  • Multi-Wavelength Digital Holography for Erosion Measurements inside the ITER Tokamak

    by Giancarlo Pedrini, Igor Alekseenko, Wolfgang Osten, Govind Jagannathan, Mark Kempenaars, George Vayakis

    Experimental results of remote shape measurements of objects located at a distance of more than 6 m from the detector with depth accuracies of 10 μm are presented. The system is planned for erosion measurements inside the ITER Tokamak reactor.