Benedikt Meier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Benedikt Meier has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Jens O. Fiedler
Wilo SE, Dortmund, 44263, Germany
2 shared publicationsMartin Oettmeier
Wilo SE, Dortmund, 44263, Germany
2 shared publicationsTorsten Bertram
TU Dortmund University, Institute of Control Theory and Systems Engineering, Dortmund, 44227, Germany
2 shared publications- Annika Raatz
Leibniz University Hannover
1 shared publication Joshua Göke
Leibniz Universität Hannover
1 shared publication- Sebastian Blankemeyer
Leibniz Universität Hannover
1 shared publication
Latest Publications
- Open Access
- 31 December 2018
- Published by Springer Nature
- p. 72-81
Gesture-Based Robot Programming Using Microsoft Kinect
- 31 December 2018
- Published by Springer Nature
- p. 72-81
Open AccessGesture-Based Robot Programming Using Microsoft Kinect
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 539-544
Power Consumption Model of a Circulating Wet Runner Pump
In this paper the power consumption model of a circulating wet runner pump is presented. Such a model provides several advantages since it can be used for example to detect issues during operation of the pump. For instance, dry running which might damage the bearings of the pump can be detected based on deviations between the measured power and the power predicted by the model. Furthermore, based on the power model the volume flow which passes the pump can be determined without a volume flow sensor and thus save costs. As the overall power consumption of the pump is influenced by different components such as electrical and friction losses, models of the individual components which have an influence on the power consumption are presented. Then, the components are combined to one overall power consumption model and the model parameters are identified by measurements. Finally, the model is validated by comparison of the dynamic behaviour of the model with the actual measured power consumption.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 539-544
Power Consumption Model of a Circulating Wet Runner Pump
In this paper the power consumption model of a circulating wet runner pump is presented. Such a model provides several advantages since it can be used for example to detect issues during operation of the pump. For instance, dry running which might damage the bearings of the pump can be detected based on deviations between the measured power and the power predicted by the model. Furthermore, based on the power model the volume flow which passes the pump can be determined without a volume flow sensor and thus save costs. As the overall power consumption of the pump is influenced by different components such as electrical and friction losses, models of the individual components which have an influence on the power consumption are presented. Then, the components are combined to one overall power consumption model and the model parameters are identified by measurements. Finally, the model is validated by comparison of the dynamic behaviour of the model with the actual measured power consumption.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2778-2783
Enabling sensorless control of a permanent magnet synchronous machine in the low speed region using saturation
In this paper the sensorless control of a permanent magnet synchronous machine which is meant to be used in pump applications is discussed. The sensorless control in the middle and high speed region can be considered as state of the art. In contrast to that, sensorless control in the low speed region for use in industrial applications still is an issue. Therefore, this paper focuses on saliency based sensorless control employing high frequency signal injection which usually is applied for low speed applications. However, it is shown that the used machine does not provide the required properties for such kind of sensorless control. Therefore, a new strategy is presented which compensates for the insufficient properties regarding position estimation in order to allow a saliency based approach anyway.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2778-2783
Enabling sensorless control of a permanent magnet synchronous machine in the low speed region using saturation
In this paper the sensorless control of a permanent magnet synchronous machine which is meant to be used in pump applications is discussed. The sensorless control in the middle and high speed region can be considered as state of the art. In contrast to that, sensorless control in the low speed region for use in industrial applications still is an issue. Therefore, this paper focuses on saliency based sensorless control employing high frequency signal injection which usually is applied for low speed applications. However, it is shown that the used machine does not provide the required properties for such kind of sensorless control. Therefore, a new strategy is presented which compensates for the insufficient properties regarding position estimation in order to allow a saliency based approach anyway.