Latest Publications

  • Open Access

    A Compact, Lightweight Robotic Ankle-Foot Prosthesis: Featuring a Powered Polycentric Design

    by Lukas Gabert, Sarah Hood, Minh Tran, Marco Cempini, Tommaso Lenzi

    Robotic ankle-foot prostheses aim to improve the mobility of individuals with belowknee amputations by closely imitating the biomechanical function of the missing biological limb. To accomplish this goal, they must provide biomechanically accurate torque during ambulation. In addition, they must satisfy further requirements such as build height, range of motion (ROM), and weight. These requirements are critical for determining the potential number of users, range of activities that can be performed, and clinical outcomes. Previous studies have proposed addressing this challenge through the use of advanced actuation systems with series and parallel elastic actuators, clutchable leverages, and pneumatic artificial muscles. These ad vanced actuation systems have shown improved mechanical and electrical efficiency compared to conventional servo motors, making powered ankle prostheses possible. However, the improved efficiency comes at the expense of a tall build height, reduced ROM, and significant increase in weight, thus limiting the clinical viability of currently available powered prostheses.


  • Open Access

    Design and Experimental Characterization of a Shoulder-Elbow Exoskeleton With Compliant Joints for Post-Stroke Rehabilitation

    by Emilio Trigili, Simona Crea, Matteo Moise, Andrea Baldoni, Marco Cempini, Giorgia Ercolini, Dario Marconi, Federico Posteraro, Maria Chiara Carrozza, Nicola Vitiello

    This paper presents the design and experimental characterization of a 4-degree-of-freedom shoulder-elbow exoskeleton (NESM) for upper-limb neurorehabilitation and treatment of spasticity. The NESM employs a self-aligning mechanism based on passive rotational joints to smoothly self-align the robot's rotational axes to the user's ones. Compliant yet high-torque series-elastic actuators allow the NESM to safely interact with the user, particularly in response to sudden unpredicted movements, such as those caused by spastic contractions. The NESM control system provides a variety of rehabilitation exercises, enabling the customization of therapy to patients exhibiting a range of movement capabilities. Available exercises include passive mobilization, active-assisted, active-resisted, and active-disturbed training modes. The experimental characterization of two NESM actuation units demonstrated position and torque control performance suitable for use in neurorehabilitation applications, including up to 7 Hz of bandwidth in torque control. An algorithm for online detection of spastic contractions or sudden object collisions has been implemented and tested as well, with results suggesting that the current system can ensure safe interaction with patients.


  • Design, Development, and Validation of a Lightweight Nonbackdrivable Robotic Ankle Prosthesis

    by Tommaso Lenzi, Marco Cempini, Levi J. Hargrove, Todd A. Kuiken

    Robotic ankle prostheses can imitate the biomechanical function of intact legs at the cost of a larger weight and size compared to conventional passive prostheses. Unfortunately, increased weight and size negatively affect comfort and socket stability, ultimately limiting their clinical viability. Alternatively, a nonbackdrivable transmission system can be used to actively regulate the ankle position during nonweight bearing activities only. This semiactive design can be made smaller and lighter as a result of the lower actuation power requirements. However, the transmission system must withstand high loads during stance and standing. Thus, available semiactive prostheses are still significantly heavier and have a larger build height than passive ankle prostheses. In this paper, we present the design, development, and validation of a semiactive ankle prosthesis with a nonbackdrivable cam-follower mechanism designed to lower the load on moving components and align with the foot longitudinally as necessary to reduce the prosthesis weight and size. The proposed ankle mechanism is ~50% shorter, has ~40% wider range of motion (ROM), and is estimated to be ~27% lighter than available semiactive prostheses. Experiments with a transtibial subject show that the semiactive prosthesis can increase foot clearance up to 142% and reduce the load on the residual limb as low as 32% compared to passive prostheses.


  • Open Access

    Physical human-robot interaction of an active pelvis orthosis: toward ergonomic assessment of wearable robots

    by Nicolò D’eLia, Federica Vanetti, Marco Cempini, Guido Pasquini, Andrea Parri, Marco Rabuffetti, Maurizio Ferrarin, Raffaele Molino Lova, Nicola Vitiello

    In human-centered robotics, exoskeletons are becoming relevant for addressing needs in the healthcare and industrial domains. Owing to their close interaction with the user, the safety and ergonomics of these systems are critical design features that require systematic evaluation methodologies. Proper transfer of mechanical power requires optimal tuning of the kinematic coupling between the robotic and anatomical joint rotation axes. We present the methods and results of an experimental evaluation of the physical interaction with an active pelvis orthosis (APO). This device was designed to effectively assist in hip flexion-extension during locomotion with a minimum impact on the physiological human kinematics, owing to a set of passive degrees of freedom for self-alignment of the human and robotic hip flexion-extension axes. Five healthy volunteers walked on a treadmill at different speeds without and with the APO under different levels of assistance. The user-APO physical interaction was evaluated in terms of: (i) the deviation of human lower-limb joint kinematics when wearing the APO with respect to the physiological behavior (i.e., without the APO); (ii) relative displacements between the APO orthotic shells and the corresponding body segments; and (iii) the discrepancy between the kinematics of the APO and the wearer’s hip joints. The results show: (i) negligible interference of the APO in human kinematics under all the experimented conditions; (ii) small (i.e., < 1 cm) relative displacements between the APO cuffs and the corresponding body segments (called stability); and (iii) significant increment in the human-robot kinematics discrepancy at the hip flexion-extension joint associated with speed and assistance level increase. APO mechanics and actuation have negligible interference in human locomotion. Human kinematics was not affected by the APO under all tested conditions. In addition, under all tested conditions, there was no relevant relative displacement between the orthotic cuffs and the corresponding anatomical segments. Hence, the physical human-robot coupling is reliable. These facts prove that the adopted mechanical design of passive degrees of freedom allows an effective human-robot kinematic coupling. We believe that this analysis may be useful for the definition of evaluation metrics for the ergonomics assessment of wearable robots.


  • Functional Design of a Powered Elbow Orthosis Toward its Clinical Employment

    by Nicola Vitiello, Marco Cempini, Simona Crea, Francesco Giovacchini, Mario Cortese, Matteo Moise, Federico Posteraro, Maria Chiara Carrozza

    This paper presents the design and preliminary evaluation of a novel version of the robotic elbow exoskeleton NEUROExos, designed for the in-clinic treatment of stroke survivors in acute and subacute phases. The robotic design implements a novel series elastic actuation system, a 4-degree-of-freedom (DoFs) passive mechanism for the anatomical axis alignment, and one active DoF with remote cable-driven actuation. The low-level control system allows two working modalities: a torque control and a joint position control. The high-level control system employs a finite-state machine that allows the setting and execution of these modalities during rehabilitation exercises. Preliminary pilot tests based on passive exercises, with three chronic post-stroke patients, demonstrated the effectiveness of the proposed approach in assessing joint rigidity and its usability within a rehabilitation clinic.


  • Open Access

    Vision-Based Pose Estimation for Robot-Mediated Hand Telerehabilitation

    by Giuseppe Airò Farulla, Daniele Pianu, Marco Cempini, Mario Cortese, Ludovico O. Russo, Marco Indaco, Roberto Nerino, Antonio Chimienti, Calogero M. Oddo, Nicola Vitiello

    Vision-based Pose Estimation (VPE) represents a non-invasive solution to allow a smooth and natural interaction between a human user and a robotic system, without requiring complex calibration procedures. Moreover, VPE interfaces are gaining momentum as they are highly intuitive, such that they can be used from untrained personnel (e.g., a generic caregiver) even in delicate tasks as rehabilitation exercises. In this paper, we present a novel master–slave setup for hand telerehabilitation with an intuitive and simple interface for remote control of a wearable hand exoskeleton, named HX. While performing rehabilitative exercises, the master unit evaluates the 3D position of a human operator’s hand joints in real-time using only a RGB-D camera, and commands remotely the slave exoskeleton. Within the slave unit, the exoskeleton replicates hand movements and an external grip sensor records interaction forces, that are fed back to the operator-therapist, allowing a direct real-time assessment of the rehabilitative task. Experimental data collected with an operator and six volunteers are provided to show the feasibility of the proposed system and its performances. The results demonstrate that, leveraging on our system, the operator was able to directly control volunteers’ hands movements.


  • A light-weight active orthosis for hip movement assistance

    by Francesco Giovacchini, Federica Vannetti, Matteo Fantozzi, Marco Cempini, Mario Cortese, Andrea Parri, Tingfang Yan, Dirk Lefeber, Nicola Vitiello


  • Ergonomic assessment of an active pelvis orthosis

    by Nicolò D’Elia, Federica Vannetti, Marco Cempini, Guido Pasquini, Marco Rabuffetti, Maurizio Ferrarin, Raffaele Molino Lova, Nicola Vitiello


  • Top Cited Papers

    Review of assistive strategies in powered lower-limb orthoses and exoskeletons

    by Tingfang Yan, Marco Cempini, Calogero Maria Oddo, Nicola Vitiello