EMEnrique Esteban Mombello

Enrique Esteban Mombello

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enrique Esteban Mombello has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implementation of the State-Space Power Transformer Model in ATP for High Frequency Transient Studies

    by Guillermo A. Diaz, Hans K. Høidalen, Enrique E. Mombello, Camilo A. Cortes

    State-space representation is a practical, efficient and reliable way to evaluate the high-frequency interaction of a transformer with the power network under different types of disturbances. Currently, this representation is available in commercial electromagnetic transient programs; however, this important tool is not yet implemented in the alternative transient program ATP. This paper describes the implementation methodology of the state-space model of the power transformer in ATP using the Norton type-94 component and foreign models. The proposed implementation incorporates several aspects relevant to its application in realistic situations, including initialization from steady state, customization of information exchange between the manufacturer and the purchaser, and accurate consideration of damping. The implemented model in ATP is validated on a real 50 MVA power transformer by means of three relevant example cases, obtaining an excellent agreement between the reference data and those calculated with ATP.


  • Methodology for Fast Calculation of Impedance Matrix of Power Transformers for High Frequency Transient Studies

    by Guillermo A. Diaz, Enrique E. Mombello, Jhon Perez G., Hans K. Høidalen

    Power transformers are exposed to a variety of disturbances that may jeopardize their lifespan and the safe operation of the power system. The transient behavior of the transformer can be assessed by means of white-box models. The main prerequisite for the development of the white-box model is the frequency-dependent impedance matrix of the transformer. The main obstacle that restricts the use of white-box models at industrial level lies in the computation of the impedance matrix, since this calculation requires magnetic-field numerical simulations, which demand disproportionate calculation times when performed with traditional techniques such as the finite element method (FEM). That is why this paper proposes a new methodology for the fast calculation of the frequency-dependent impedance matrix of power transformers, which produces matrices suitable for the development of accurate white-box models. The proposed methodology was validated on a real 50 MVA transformer. Two white-box models were elaborated, one from the impedance matrix calculated with the proposed method and other using the matrix obtained with FEM. Excellent agreement was found between the transient response measurements and the response obtained with both models, however the proposed method reported a drastic reduction in computation time compared to FEM.


  • A fuzzy inference-based approach for estimating power transformers risk index

    by Ricardo D. Medina, Diego A. Zaldivar, Andrés A. Romero, Jefferson Zuñiga, Enrique E. Mombello


  • New Compact White-Box Transformer Model for the Calculation of Electromagnetic Transients

    by Enrique E. Mombello

    In a recent work, a successful power transformer white-box model for the calculation of electromagnetic transients has been presented. Although this model gives very satisfactory results, when applied to large transformers it requires a large number of auxiliary loops to model the damping. This can be problematic as it not only requires more computational effort, but the size of the input data may even preclude its use with ATP-EMTP and perhaps with other EMTP-based software that have limitations in this regard. In this work a new reduced model which enables its use with ATP-EMTP is presented. This model requires a much smaller number of circuit components than the original model, which allows the data size and simulation time to be substantially reduced without practically affecting the calculation results. This has been achieved through the reduction of the rank of the sub-matrices that characterize the inductive coupling between the main winding sections and the auxiliary loops used to model the damping. The new model has been validated by making comparisons of the frequency responses calculated using the new compact model with the ones calculated with the original model developed for the case study used by the CIGRE JWG A2/C4.52 to test the accuracy of various types of transformer models.


  • New State-Space White-Box Transformer Model for the Calculation of Electromagnetic Transients

    by Enrique E. Mombello, Alvaro Portillo, Guillermo A. Diaz Florez

    White-box models are detailed models for the investigation of the internal behavior of transformers during dielectric design. A new model of this type with significantly improved characteristics is presented in this paper. The model has been developed in state-space form, which is more flexible than an equivalent circuit and also makes it possible to optionally hide proprietary information on internal voltages. The proposed parameter determination methodology is very robust and allows the adequate representation of the damping. The methodology for determining inductive impedances and capacitances as a function of frequency using the Finite Element Method is described first. Then the fitting of the impedances obtained in the frequency domain by means of rational approximation functions is presented, which is based on the Vector Fitting algorithm in combination with Particle Swarm Optimization. The state-space model is obtained next, which is then used to perform time and frequency domain calculations. This new model has been successfully validated by comparison with measurements on a large power transformer used as case study during the activities of the JWG CIGRE A2/C4.52.


  • Mathematical formulation of a new linear surface element for the modeling of axisymmetric magnetic field problems

    by Guillermo Andrés Díaz Flórez, Enrique E. Mombello, Stephan Voss

    There are currently two main trends in solving magnetic field problems, numerical methods, of which the Finite Element Method (FEM) is undoubtedly the most popular, and analytical methods, of which there is a great diversity of approaches. The main advantage of numerical methods is their flexibility in modeling complicated geometries; however, its calculation times are generally considerable. Analytical methods attain very short calculation times by sacrificing flexibility. This paper presents the mathematical formulation of a new linear surface element for the semi-analytical solution of axisymmetric magnetic field problems. The importance of this formulation is that it is capable of dealing with arbitrary geometries while retaining the flexibility of numerical methods with considerably shorter calculation times. The results of the application of the proposed formulation to a case study are presented in the validation section. The results obtained are compared with those calculated with FEM showing an excellent agreement between them.


  • Transformer Thermal Capacity Estimation and Prediction Using Dynamic Rating Monitoring

    by David L. Alvarez, Sergio R. Rivera, Enrique Esteban Mombello

    Dynamic rating monitoring is a solution to face challenges in both the operation and the planning of power systems. With thermal monitoring, dynamic overloads of transformers are allowed, however, the thermal model used to predict hot-spot must be capable of ensuring the assessment of insulation life expectancy. Hence, this paper presents an online algorithm to estimate and predict transformers' rating in order to assess the overload capability during short and long times. The overload factors are computed using estimations of top-oil temperature. The main characteristic of this proposal is that the environmental cooling conditions are considered by the fitting of the parameters of a simple equivalent thermal circuit using an Extended Kalman Filter during the transformer operation. To validate the implementation of the algorithm, the information provided by typical transformer rating monitoring systems is used. Thus, the performance and effectiveness of the algorithm are verified using field measurement data during the normal operation of two power transformers.


  • Calculation of Leakage Reactance in Transformers With Constructive Deformations in Low Voltage Foil Windings

    by Guillermo A. Diaz F., Enrique Esteban Mombello, Guillermo D. Guidi Venerdini

    Foil-winding transformers with high currents in low voltage winding normally have copper/aluminum bars as leads of the coils. A practical solution for locating bar leads without increasing the size of the active part is to flatten the coil in the leads zone causing a deformation. Abnormalities in the leakage reactance have been identified in this type of transformers. In order to take this effect into account, this work proposes a correction to the mathematical formulation for calculating the leakage reactance in transformers with deformations in the low voltage winding. Three methods for calculating the leakage reactance have been compared for four real case studies: the proposed formulation, the commonly used formulation and detailed simulations with the finite element method in 3D (FEM3D). The leakage reactance calculated with the proposed method has been found to have an improved accuracy compared with the one calculated using the formulation without correction in all case studies. The main contribution of this work is that the proposed correction in the formulation makes it possible to increase the accuracy in the calculation of leakage reactance, avoiding the need to resort to detailed simulations with FEM3D.


  • Conductor Temperature Estimation and Prediction at Thermal Transient State in Dynamic Line Rating Application

    by David L. Alvarez, Filipe Miguel Faria da Silva, Enrique Esteban Mombello, Claus Leth Bak, Javier A. Rosero

    The traditional methodology for defining the ampacity of overhead lines is based on conservative criteria regarding the operating conditions of the line, leading to the so-called static line rating. Although this procedure has been considered satisfactory for decades, it is nowadays sensible to account for more realistic line operating conditions when calculating its dynamic ampacity. Dynamic line rating is a technology used to improve the ampacity of overhead transmission lines based on the assumption that ampacity is not a static value but a function of weather and line's operating conditions. This paper presents an algorithm to estimate and predict the temperature in overhead line conductors using an Extended Kalman Filter. The proposed algorithm assumes both actual weather and current intensity flowing along the conductor as control variables. The temperature of the conductor, mechanical tension and sag of the catenary are used as measurements because the common practice is to measure these values with dynamic line rating hardware. The algorithm has been validated by both simulations and measurements. The results of this study conclude that it is possible to implement the algorithm into Dynamic Line Rating systems, leading to a more accurate estimation and prediction of temperature.