Ari-Pekka Forsback
Research Subjects
Ari-Pekka Forsback has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Aarne Mattila
DelSiTech Ltd. Turku Finland
1 shared publication- Aki Laakso
Department of Neurosurgery, Helsinki University Hospital, Finland; and
1 shared publication - Camilla Borglin
Ferring Pharmaceuticals, 2770 Kastrup, Copenhagen, Denmark
1 shared publication - Carsten Terjung
Bayer AG, Pharmaceuticals, Research and Development, Aprather Weg 18a, Wuppertal 42113, Germany
1 shared publication Florian Unger
Pharmaceuticals Research & Development Bayer AG Wuppertal Germany
1 shared publicationFrederic Dargelas
DelSiTech Ltd. Turku Finland
1 shared publication
Latest Publications
- Open Access
- 16 June 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (6) , 1578
Sustained In-Vivo Release of Triptorelin Acetate from a Biodegradable Silica Depot: Comparison to Pamorelin® LA
Triptorelin acetate was encapsulated into silica microparticles by spray-drying a mixture of colloidal silica sol and triptorelin acetate solution. The resulting microparticles were then combined with another silica sol containing silica nanoparticles, which together formed an injectable silica-triptorelin acetate depot. The particle size and surface morphology of the silica-triptorelin acetate microparticles were characterized together with the in vitro release of triptorelin, injectability and rheology of the final injectable silica-triptorelin acetate depot. In vivo pharmacokinetics and pharmacodynamics of the silica-triptorelin acetate depot and Pamorelin® were evaluated and compared in Sprague-Dawley male rats after subcutaneous administration. Serum samples up to 91 days were collected and the plasma concentrations of triptorelin and testosterone were analyzed with ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). In vivo pharmacokinetics showed that injections of the silica-triptorelin acetate depot gave 5-fold lower Cmax values than the corresponding Pamorelin® injections. The depot also showed a comparable sustained triptorelin release and equivalent pharmacodynamic effect as the Pamorelin® injections. Detectable triptorelin plasma concentrations were seen with the depot after the 91-day study period and testosterone plasma concentrations remained below the human castration limit for the same period.
- 16 June 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (6) , 1578
Open AccessSustained In-Vivo Release of Triptorelin Acetate from a Biodegradable Silica Depot: Comparison to Pamorelin® LA
Triptorelin acetate was encapsulated into silica microparticles by spray-drying a mixture of colloidal silica sol and triptorelin acetate solution. The resulting microparticles were then combined with another silica sol containing silica nanoparticles, which together formed an injectable silica-triptorelin acetate depot. The particle size and surface morphology of the silica-triptorelin acetate microparticles were characterized together with the in vitro release of triptorelin, injectability and rheology of the final injectable silica-triptorelin acetate depot. In vivo pharmacokinetics and pharmacodynamics of the silica-triptorelin acetate depot and Pamorelin® were evaluated and compared in Sprague-Dawley male rats after subcutaneous administration. Serum samples up to 91 days were collected and the plasma concentrations of triptorelin and testosterone were analyzed with ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). In vivo pharmacokinetics showed that injections of the silica-triptorelin acetate depot gave 5-fold lower Cmax values than the corresponding Pamorelin® injections. The depot also showed a comparable sustained triptorelin release and equivalent pharmacodynamic effect as the Pamorelin® injections. Detectable triptorelin plasma concentrations were seen with the depot after the 91-day study period and testosterone plasma concentrations remained below the human castration limit for the same period.
- Open Access
- 17 January 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (S265)
Development of injectable long‐acting controlled release intravitreal depot of BAY224 using biodegradable silica microparticle‐silica hydrogel composite
Purpose: Intravitreal (IVT) therapies are a standard of care for many ocular diseases. Frequent administration and injection‐based adverse events pose a hurdle for effective upkeep of ocular health. Developing improved effective treatment durations has gained significant traction. This study investigated if a near water‐insoluble drug, BAY224, could be encapsulated in biodegradable silica microparticles (SMP) and exhibit sustained controlled in vitro and in vivo release through a surface eroding SMP‐silica hydrogel composite (silica‐silica composite).Methods: BAY224 was encapsulated in a silica matrix by sol‐gel chemistry and spray drying. In vitro silica dissolution and BAY224 release from silica‐silica composite was analyzed followed by studying in vivo IVT release in rabbits. In vitro silica dissolution was studied in sink conditions colorimetrically. Cumulative release and total BAY224 content were analyzed by HPLC. In vivo release was studied by LC‐MS/MS of sample vitreous humor up to 55 days post 30 µl IVT injections.Results: BAY224 was encapsulated, and silica‐silica composite was made at a load of 1 mg/50 µL (5.7 wt‐%). BAY224‐SMPs were sterilized using γ‐irradiation (26.8–47.5 kGy) not affecting in vitro dissolution. Burst release of BAY224 was >9 wt‐% in SMP and silica‐silica composite. Release of API was controlled by silica matrix surface erosion. In accelerated in vitro dissolution, the release time of BAY224 from SMP was 8–9 days. The silica‐silica composite prolonged release to 9–10 days. With the relevant in vitro‐in vivo correlation factor, in vivo release of 3 months was hypothesized. In vivo PK data showed sustained release of BAY224 in vitreous for at least 55 days. Daily API release (calculated from the API remnant in depot) was ca. 5–8 µg/day.Conclusions: Efficient encapsulation of a near insoluble drug was achieved with a silica‐silica composite with no burst release and a long‐acting release in‐vivo of >55 days in line with the in‐vitro dissolution results.
- 17 January 2021
- Published by Wiley in Acta Ophthalmologica
- Vol. 99 (S265)
Open AccessDevelopment of injectable long‐acting controlled release intravitreal depot of BAY224 using biodegradable silica microparticle‐silica hydrogel composite
Purpose: Intravitreal (IVT) therapies are a standard of care for many ocular diseases. Frequent administration and injection‐based adverse events pose a hurdle for effective upkeep of ocular health. Developing improved effective treatment durations has gained significant traction. This study investigated if a near water‐insoluble drug, BAY224, could be encapsulated in biodegradable silica microparticles (SMP) and exhibit sustained controlled in vitro and in vivo release through a surface eroding SMP‐silica hydrogel composite (silica‐silica composite).Methods: BAY224 was encapsulated in a silica matrix by sol‐gel chemistry and spray drying. In vitro silica dissolution and BAY224 release from silica‐silica composite was analyzed followed by studying in vivo IVT release in rabbits. In vitro silica dissolution was studied in sink conditions colorimetrically. Cumulative release and total BAY224 content were analyzed by HPLC. In vivo release was studied by LC‐MS/MS of sample vitreous humor up to 55 days post 30 µl IVT injections.Results: BAY224 was encapsulated, and silica‐silica composite was made at a load of 1 mg/50 µL (5.7 wt‐%). BAY224‐SMPs were sterilized using γ‐irradiation (26.8–47.5 kGy) not affecting in vitro dissolution. Burst release of BAY224 was >9 wt‐% in SMP and silica‐silica composite. Release of API was controlled by silica matrix surface erosion. In accelerated in vitro dissolution, the release time of BAY224 from SMP was 8–9 days. The silica‐silica composite prolonged release to 9–10 days. With the relevant in vitro‐in vivo correlation factor, in vivo release of 3 months was hypothesized. In vivo PK data showed sustained release of BAY224 in vitreous for at least 55 days. Daily API release (calculated from the API remnant in depot) was ca. 5–8 µg/day.Conclusions: Efficient encapsulation of a near insoluble drug was achieved with a silica‐silica composite with no burst release and a long‐acting release in‐vivo of >55 days in line with the in‐vitro dissolution results.
- Open Access
- 22 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-10
Intracranial Biodegradable Silica-Based Nimodipine Drug Release Implant for Treating Vasospasm in Subarachnoid Hemorrhage in an Experimental Healthy Pig and Dog Model
Nimodipine is a widely used medication for treating delayed cerebral ischemia (DCI) after subarachnoid hemorrhage. When administrated orally or intravenously, systemic hypotension is an undesirable side effect. Intracranial subarachnoid delivery of nimodipine during aneurysm clipping may be more efficient way of preventing vasospasm and DCI due to higher concentration of nimodipine in cerebrospinal fluid (CSF). The risk of systemic hypotension may also be decreased with intracranial delivery. We used animal models to evaluate the feasibility of surgically implanting a silica-based nimodipine releasing implant into the subarachnoid space through a frontotemporal craniotomy. Concentrations of released nimodipine were measured from plasma samples and CSF samples. Implant degradation was followed using CT imaging. After completing the recovery period, full histological examination was performed on the brain and meninges. Thein vitrocharacteristics of the implant were determined. Our results show that the biodegradable silica-based implant can be used for an intracranial drug delivery system and no major histopathological foreign body reactions were observed. CT imaging is a feasible method for determining the degradation of silica implantsin vivo. The sustained release profiles of nimodipine in CSF were achieved. Compared to a traditional treatment, higher nimodipine CSF/plasma ratios can be obtained with the implant.
- 22 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-10
Open AccessIntracranial Biodegradable Silica-Based Nimodipine Drug Release Implant for Treating Vasospasm in Subarachnoid Hemorrhage in an Experimental Healthy Pig and Dog Model
Nimodipine is a widely used medication for treating delayed cerebral ischemia (DCI) after subarachnoid hemorrhage. When administrated orally or intravenously, systemic hypotension is an undesirable side effect. Intracranial subarachnoid delivery of nimodipine during aneurysm clipping may be more efficient way of preventing vasospasm and DCI due to higher concentration of nimodipine in cerebrospinal fluid (CSF). The risk of systemic hypotension may also be decreased with intracranial delivery. We used animal models to evaluate the feasibility of surgically implanting a silica-based nimodipine releasing implant into the subarachnoid space through a frontotemporal craniotomy. Concentrations of released nimodipine were measured from plasma samples and CSF samples. Implant degradation was followed using CT imaging. After completing the recovery period, full histological examination was performed on the brain and meninges. Thein vitrocharacteristics of the implant were determined. Our results show that the biodegradable silica-based implant can be used for an intracranial drug delivery system and no major histopathological foreign body reactions were observed. CT imaging is a feasible method for determining the degradation of silica implantsin vivo. The sustained release profiles of nimodipine in CSF were achieved. Compared to a traditional treatment, higher nimodipine CSF/plasma ratios can be obtained with the implant.