Sergio Ruiz de Galarreta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sergio Ruiz de Galarreta has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Raúl Antón
Universidad de Navarra
6 shared publications - Aitor Cazón
University of Navarra
5 shared publications - Naiara Rodriguez-Florez
Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
5 shared publications - Ender A. Finol
Department of Mechanical, Aerospace, and Industrial Engineering, The University of Texas at San Antonio, San Antonio, TX 78249, USA
3 shared publications - Markel Alaña
Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain
3 shared publications - Aitziber Lopez-Arancibia
Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018 San Sebastian, Spain
2 shared publications
Latest Publications
- Open Access
- 26 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Comportamiento mecánico de estructuras porosas bajo cargas combinadas
El incremento de la población geriátrica con problemas musculoesqueléticos, sumado al incremento de lesiones derivadas de actividades deportivas y accidentes de tráfico, ha impulsado la demanda de cirugías ortopédicas de cadera, rodilla o columna vertebral entre otras. En estos últimos años, y gracias al desarrollo en la fabricación aditiva, se está estudiando la posibilidad de incluir estructuras porosas en el diseño de implantes ortopédicos personalizados. Su gran ventaja frente a los implantes tradicionales es su versatilidad para ajustar sus propiedades mecánicas a las del hueso adyacente y reducir de esta forma el fenómeno conocido como stress-shielding. Asimismo, estas estructuras porosas favorecen la oseointegración y regeneración ósea. En la actualidad hay numerosos estudios que han analizado el comportamiento de este tipo de estructuras bajo cargas de compresión, obteniendo así ecuaciones que definen el módulo elástico y la resistencia a fluencia equivalente de la estructura en función del material base y de la porosidad. Sin embargo, no existen tantos trabajos estudiando el comportamiento de estas estructuras bajo cargas combinadas de compresión y cortadura. Teniendo en cuenta que este tipo de cargas se pueden encontrar frecuentemente en algunos implantes ortopédicos, en este trabajo se ha estudiado por elementos finitos el comportamiento de diferentes estructuras porosas bajo cargas de compresión, cortante y bajo 5 cargas combinadas. Se han estudiado 5 porosidades diferentes para cada estructura y se ha analizado también la influencia de la esbeltez geométrica de la estructura. La esbeltez de la estructura porosa juega un papel importante en los efectos de la flexión y por ello se han estudiado diferentes esbelteces. Se ha analizado por un lado el módulo elástico y de cortadura equivalente de cada estructura, y por otro su resistencia a fluencia. Con los resultados obtenidos se ha definido una ecuación que determina la resistencia de la estructura para cualquier tipo de carga combinada, y que es válida para cualquier porosidad y esbeltez. Esta ecuación puede ser muy útil a la hora de seleccionar la estructura porosa adecuada para el implante, teniendo en cuenta las cargas a las que va a estar sometido. Asimismo, puede ser de utilidad para determinar la orientación de la estructura porosa en el implante. Para poder verificar los resultados numéricos, se han fabricado estructuras con diferentes porosidades y esbelteces; y se han ensayado bajo cargas de compresión, cortante y cargas combinadas.
- 26 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Open AccessComportamiento mecánico de estructuras porosas bajo cargas combinadas
El incremento de la población geriátrica con problemas musculoesqueléticos, sumado al incremento de lesiones derivadas de actividades deportivas y accidentes de tráfico, ha impulsado la demanda de cirugías ortopédicas de cadera, rodilla o columna vertebral entre otras. En estos últimos años, y gracias al desarrollo en la fabricación aditiva, se está estudiando la posibilidad de incluir estructuras porosas en el diseño de implantes ortopédicos personalizados. Su gran ventaja frente a los implantes tradicionales es su versatilidad para ajustar sus propiedades mecánicas a las del hueso adyacente y reducir de esta forma el fenómeno conocido como stress-shielding. Asimismo, estas estructuras porosas favorecen la oseointegración y regeneración ósea. En la actualidad hay numerosos estudios que han analizado el comportamiento de este tipo de estructuras bajo cargas de compresión, obteniendo así ecuaciones que definen el módulo elástico y la resistencia a fluencia equivalente de la estructura en función del material base y de la porosidad. Sin embargo, no existen tantos trabajos estudiando el comportamiento de estas estructuras bajo cargas combinadas de compresión y cortadura. Teniendo en cuenta que este tipo de cargas se pueden encontrar frecuentemente en algunos implantes ortopédicos, en este trabajo se ha estudiado por elementos finitos el comportamiento de diferentes estructuras porosas bajo cargas de compresión, cortante y bajo 5 cargas combinadas. Se han estudiado 5 porosidades diferentes para cada estructura y se ha analizado también la influencia de la esbeltez geométrica de la estructura. La esbeltez de la estructura porosa juega un papel importante en los efectos de la flexión y por ello se han estudiado diferentes esbelteces. Se ha analizado por un lado el módulo elástico y de cortadura equivalente de cada estructura, y por otro su resistencia a fluencia. Con los resultados obtenidos se ha definido una ecuación que determina la resistencia de la estructura para cualquier tipo de carga combinada, y que es válida para cualquier porosidad y esbeltez. Esta ecuación puede ser muy útil a la hora de seleccionar la estructura porosa adecuada para el implante, teniendo en cuenta las cargas a las que va a estar sometido. Asimismo, puede ser de utilidad para determinar la orientación de la estructura porosa en el implante. Para poder verificar los resultados numéricos, se han fabricado estructuras con diferentes porosidades y esbelteces; y se han ensayado bajo cargas de compresión, cortante y cargas combinadas.
- Open Access
- 29 September 2023
- Published by Springer Nature in npj Regenerative Medicine
- Vol. 8 (1) , 1-14
An engineered periosteum for efficient delivery of rhBMP-2 and mesenchymal progenitor cells during bone regeneration
During bone regeneration, the periosteum acts as a carrier for key regenerative cues, delivering osteochondroprogenitor cells and crucial growth factors to the injured bone. We developed a biocompatible, 3D polycaprolactone (PCL) melt electro-written membrane to act as a mimetic periosteum. Poly (ethyl acrylate) coating of the PCL membrane allowed functionalization, mediated by fibronectin and low dose recombinant human BMP-2 (rhBMP-2) (10-25 μg/ml), resulting in efficient, sustained osteoinduction in vitro. In vivo, rhBMP-2 functionalized mimetic periosteum demonstrated regenerative potential in the treatment of rat critical-size femoral defects with highly efficient healing and functional recovery (80%-93%). Mimetic periosteum has also proven to be efficient for cell delivery, as observed through the migration of transplanted periosteum-derived mesenchymal cells to the bone defect and their survival. Ultimately, mimetic periosteum demonstrated its ability to deliver key stem cells and morphogens to an injured site, exposing a therapeutic and translational potential in vivo when combined with unprecedentedly low rhBMP-2 doses.
- 29 September 2023
- Published by Springer Nature in npj Regenerative Medicine
- Vol. 8 (1) , 1-14
Open AccessAn engineered periosteum for efficient delivery of rhBMP-2 and mesenchymal progenitor cells during bone regeneration
During bone regeneration, the periosteum acts as a carrier for key regenerative cues, delivering osteochondroprogenitor cells and crucial growth factors to the injured bone. We developed a biocompatible, 3D polycaprolactone (PCL) melt electro-written membrane to act as a mimetic periosteum. Poly (ethyl acrylate) coating of the PCL membrane allowed functionalization, mediated by fibronectin and low dose recombinant human BMP-2 (rhBMP-2) (10-25 μg/ml), resulting in efficient, sustained osteoinduction in vitro. In vivo, rhBMP-2 functionalized mimetic periosteum demonstrated regenerative potential in the treatment of rat critical-size femoral defects with highly efficient healing and functional recovery (80%-93%). Mimetic periosteum has also proven to be efficient for cell delivery, as observed through the migration of transplanted periosteum-derived mesenchymal cells to the bone defect and their survival. Ultimately, mimetic periosteum demonstrated its ability to deliver key stem cells and morphogens to an injured site, exposing a therapeutic and translational potential in vivo when combined with unprecedentedly low rhBMP-2 doses.
- Open Access
- 15 August 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 165, 107381
In silico assessment of the bone regeneration potential of complex porous scaffolds
- 15 August 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 165, 107381
Open AccessIn silico assessment of the bone regeneration potential of complex porous scaffolds
- Open Access
- 3 August 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 150, 105761
Additively manufactured lattice structures with controlled transverse isotropy for orthopedic porous implants
- 3 August 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 150, 105761
Open AccessAdditively manufactured lattice structures with controlled transverse isotropy for orthopedic porous implants
- Open Access
- 1 December 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 124, 104804
Analytical model for the prediction of permeability of triply periodic minimal surfaces
- 1 December 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 124, 104804
Open AccessAnalytical model for the prediction of permeability of triply periodic minimal surfaces
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104784
Laser powder bed fusion of porous graded structures: A comparison between computational and experimental analysis
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104784
Open AccessLaser powder bed fusion of porous graded structures: A comparison between computational and experimental analysis
- Open Access
- 1 April 2020
- Published by Elsevier in Materials & Design
- Vol. 189
A validated finite element analysis procedure for porous structures
- 1 April 2020
- Published by Elsevier in Materials & Design
- Vol. 189
Open AccessA validated finite element analysis procedure for porous structures
- 1 October 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 98, 357-368
Analytical model of the elastic behavior of a modified face-centered cubic lattice structure
- 1 October 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 98, 357-368
Analytical model of the elastic behavior of a modified face-centered cubic lattice structure
- 1 December 2017
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 17 (08)
INFLUENCE OF THE LOCAL MEAN CURVATURE ON THE ABDOMINAL AORTIC ANEURYSM STRESS DISTRIBUTION
An abdominal aortic aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta of at least 1.5 times its normal diameter. Although the criterion of maximum diameter is still used in clinical practice to decide when to proceed with surgical intervention, numerical studies have demonstrated the importance of other geometric factors. In this work, the influence of the local mean curvature on AAA stress distribution has been analyzed in synthetic AAA geometries via finite element analysis. The results show a significant correlation between this geometric parameter and stress, suggesting that local mean curvature should also be considered along with the diameter criterion when making decisions about surgery.
- 1 December 2017
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 17 (08)
INFLUENCE OF THE LOCAL MEAN CURVATURE ON THE ABDOMINAL AORTIC ANEURYSM STRESS DISTRIBUTION
An abdominal aortic aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta of at least 1.5 times its normal diameter. Although the criterion of maximum diameter is still used in clinical practice to decide when to proceed with surgical intervention, numerical studies have demonstrated the importance of other geometric factors. In this work, the influence of the local mean curvature on AAA stress distribution has been analyzed in synthetic AAA geometries via finite element analysis. The results show a significant correlation between this geometric parameter and stress, suggesting that local mean curvature should also be considered along with the diameter criterion when making decisions about surgery.