Arun Kumar Thittai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arun Kumar Thittai has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Sathiyamoorthy Selladurai
Biomedical Ultrasound Laboratory, Biomedical Engineering Group, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
5 shared publications Sowmiya Chandramoorthi
Indian Institute of Technology Madras, Chennai, India
4 shared publicationsAliArshad Kothawala
Indian Institute of Technology Madras,Chennai,India
2 shared publicationsAnand Ramkumar
2 shared publicationsAnudeep Vayyeti
Biomedical Ultrasound Laboratory, Department of Applied Mechanics, Indian Institute of Technology Madras, Chennai, India
2 shared publications- Bhaskara Rao Chintada
Harvard Medical School
2 shared publications
Latest Publications
- Open Access
- 4 September 2026
- Published by Springer Nature in Scientific Reports
Adaptive Gaussian-weighted nonlinear beamforming with coherence factor enhancement for reflection-mode PLD-based photoacoustic imaging
- 4 September 2026
- Published by Springer Nature in Scientific Reports
Open AccessAdaptive Gaussian-weighted nonlinear beamforming with coherence factor enhancement for reflection-mode PLD-based photoacoustic imaging
- 6 January 2025
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 47 (2) , 68-78
Study on a Strategy to Improve the Image Quality and Imaging Depth for Novel Synthetic Aperture Schemes: An Experimental Investigation
Imaging depth remains a restriction for Synthetic Aperture (SA) approaches, even though SA techniques have been shown to overcome some of the drawbacks of Conventional Focused Beamforming (CFB) technique. This limitation is attributed to lesser energy per transmit in SA techniques compared to that of CFB technique. Therefore, in this paper, a systematic investigation is done to evaluate the improvement in imaging depth and image quality of B-mode ultrasound images in the case of SA technique using PZT transducer by boosting the input voltage to the transducer, while measuring the acoustic exposure parameters recommended in international standards. Note-while acoustic exposure parameters like Mechanical and Thermal index (MI and TI, respectively) are well-studied and reported for CFB techniques, the same is not the case with novel SA techniques. For analysis, the image quality metrics of Contrast Ratio (CR), Contrast to Noise Ratio (CNR) and generalized Contrast to Noise Ratio (gCNR) are employed for the SA techniques of Synthetic Transmit Aperture (STA) and Diverging Beam Synthetic Aperture Technique (DB-SAT). The results show that, when the input voltage is increased from 45 to 70 V in PZT transducer, the following improvements in image quality parameters were observed: CR by 15.6% and 21.25%, CNR by 21.39% and 36.23% and gCNR by 14.1% and 21.5% for STA and DB-SAT techniques, respectively. Results also suggest that the considerable imaging depth improvement is achieved for the incremental input voltage till 60 V, with the highest of 7.5% depth improvement at 60 V, above which the tradeoff between the gain in imaging depth and acoustic safety index becomes critical to consider. Recently, transducers having lead magnesium nitrate lead titanate (PMN-PT) piezoelectric single crystals have shown to produce ultrasound images with higher image quality at greater depths, irrespective of the transmit schemes. The same concept of relatively higher output transmitting energy by cost expensive PMN-PT single crystal transducers for the same applied voltage, compared to the traditional lead zirconate titanate (PZT) transducers, explains the enhanced imaging depth. This study is probably the first one that reports the comparison between PMN-PT and PZT transducer, not only in terms of imaging depth but also reporting them in the context of acoustic exposure safety limits in terms of MI and TI. The findings of this study may help system designers to minimize the trade-off between cost and image quality.
- 6 January 2025
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 47 (2) , 68-78
Study on a Strategy to Improve the Image Quality and Imaging Depth for Novel Synthetic Aperture Schemes: An Experimental Investigation
Imaging depth remains a restriction for Synthetic Aperture (SA) approaches, even though SA techniques have been shown to overcome some of the drawbacks of Conventional Focused Beamforming (CFB) technique. This limitation is attributed to lesser energy per transmit in SA techniques compared to that of CFB technique. Therefore, in this paper, a systematic investigation is done to evaluate the improvement in imaging depth and image quality of B-mode ultrasound images in the case of SA technique using PZT transducer by boosting the input voltage to the transducer, while measuring the acoustic exposure parameters recommended in international standards. Note-while acoustic exposure parameters like Mechanical and Thermal index (MI and TI, respectively) are well-studied and reported for CFB techniques, the same is not the case with novel SA techniques. For analysis, the image quality metrics of Contrast Ratio (CR), Contrast to Noise Ratio (CNR) and generalized Contrast to Noise Ratio (gCNR) are employed for the SA techniques of Synthetic Transmit Aperture (STA) and Diverging Beam Synthetic Aperture Technique (DB-SAT). The results show that, when the input voltage is increased from 45 to 70 V in PZT transducer, the following improvements in image quality parameters were observed: CR by 15.6% and 21.25%, CNR by 21.39% and 36.23% and gCNR by 14.1% and 21.5% for STA and DB-SAT techniques, respectively. Results also suggest that the considerable imaging depth improvement is achieved for the incremental input voltage till 60 V, with the highest of 7.5% depth improvement at 60 V, above which the tradeoff between the gain in imaging depth and acoustic safety index becomes critical to consider. Recently, transducers having lead magnesium nitrate lead titanate (PMN-PT) piezoelectric single crystals have shown to produce ultrasound images with higher image quality at greater depths, irrespective of the transmit schemes. The same concept of relatively higher output transmitting energy by cost expensive PMN-PT single crystal transducers for the same applied voltage, compared to the traditional lead zirconate titanate (PZT) transducers, explains the enhanced imaging depth. This study is probably the first one that reports the comparison between PMN-PT and PZT transducer, not only in terms of imaging depth but also reporting them in the context of acoustic exposure safety limits in terms of MI and TI. The findings of this study may help system designers to minimize the trade-off between cost and image quality.
- 28 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 148, 107535
Advanced synthetic aperture technique to enhance image quality in ultrasound elastography: A novel strategy
- 28 November 2024
- Published by Elsevier in Ultrasonics
- Vol. 148, 107535
Advanced synthetic aperture technique to enhance image quality in ultrasound elastography: A novel strategy
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 456-459
Automated Gender Detection in an Ultrasound Image Using Object Recognition
The discernment of the gender of the fetus during obstetric ultrasound has played a major in sex-selective abortions. Researchers have shown that in India, there are approximately 50,000 to 100,000 abortions per year. Though there are laws on female feticide, poor awareness and difficulty in implementing technological solutions has made it difficult to effectively dissuade such practice. In the current scenario, B-scans are displayed on monitor screens in real time, which can lead to the unnecessary display of frames that reveal the gender of the fetus. This workflow adds undue burden on the operator to take further precautions to prevent leak of the gender information. Our work not only focuses on automatically detecting ultrasound frames that contain gender but also identify the specific region of the frame that indicated the gender, so that it can be obscured during real-time display.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 456-459
Automated Gender Detection in an Ultrasound Image Using Object Recognition
The discernment of the gender of the fetus during obstetric ultrasound has played a major in sex-selective abortions. Researchers have shown that in India, there are approximately 50,000 to 100,000 abortions per year. Though there are laws on female feticide, poor awareness and difficulty in implementing technological solutions has made it difficult to effectively dissuade such practice. In the current scenario, B-scans are displayed on monitor screens in real time, which can lead to the unnecessary display of frames that reveal the gender of the fetus. This workflow adds undue burden on the operator to take further precautions to prevent leak of the gender information. Our work not only focuses on automatically detecting ultrasound frames that contain gender but also identify the specific region of the frame that indicated the gender, so that it can be obscured during real-time display.
- 19 August 2022
- Published by Elsevier in Ultrasonics
- Vol. 126, 106832
Novel spatio-temporal non-linear beamformers for sparse synthetic aperture ultrasound imaging
- 19 August 2022
- Published by Elsevier in Ultrasonics
- Vol. 126, 106832
Novel spatio-temporal non-linear beamformers for sparse synthetic aperture ultrasound imaging
- Open Access
- 3 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Optimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systems
A novel non-linear beamforming method, namely, filtered delay optimally-weighted multiply and sum (F-DowMAS) beamforming is reported for conventional focused beamforming (CFB) technique. The performance of F-DowMAS was compared against delay and sum (DAS), filtered delay multiply and sum (F-DMAS), filtered delay weight multiply and sum (F-DwMAS) and filter delay Euclidian weighted multiply and sum (F-DewMAS) methods. Notably, in the proposed method the optimal adaptive weights are computed for each imaging point to compensate for the effects due to spatial variations in beam pattern in CFB technique. F-DowMAS, F-DMAS, and DAS were compared in terms of the resulting image quality metrics, Lateral resolution (LR), axial resolution (AR), contrast ratio (CR) and contrast-to-noise ratio (CNR), estimated from experiments on a commercially available tissue-mimicking phantom. The results demonstrate that F-DowMAS improved the AR by 57.04% and 46.95%, LR by 58.21% and 53.40%, CR by 67.35% and 39.25%, and CNR by 44.04% and 30.57% compared to those obtained using DAS and F-DMAS, respectively. Thus, it can be concluded that the newly proposed F-DowMAS outperforms DAS and F-DMAS. As an aside, we also show that the optimal weighting strategy can be extended to benefit DAS.
- 3 November 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Open AccessOptimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systems
A novel non-linear beamforming method, namely, filtered delay optimally-weighted multiply and sum (F-DowMAS) beamforming is reported for conventional focused beamforming (CFB) technique. The performance of F-DowMAS was compared against delay and sum (DAS), filtered delay multiply and sum (F-DMAS), filtered delay weight multiply and sum (F-DwMAS) and filter delay Euclidian weighted multiply and sum (F-DewMAS) methods. Notably, in the proposed method the optimal adaptive weights are computed for each imaging point to compensate for the effects due to spatial variations in beam pattern in CFB technique. F-DowMAS, F-DMAS, and DAS were compared in terms of the resulting image quality metrics, Lateral resolution (LR), axial resolution (AR), contrast ratio (CR) and contrast-to-noise ratio (CNR), estimated from experiments on a commercially available tissue-mimicking phantom. The results demonstrate that F-DowMAS improved the AR by 57.04% and 46.95%, LR by 58.21% and 53.40%, CR by 67.35% and 39.25%, and CNR by 44.04% and 30.57% compared to those obtained using DAS and F-DMAS, respectively. Thus, it can be concluded that the newly proposed F-DowMAS outperforms DAS and F-DMAS. As an aside, we also show that the optimal weighting strategy can be extended to benefit DAS.
- 27 August 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 96 (1) , 46-52
A Poly-vinyl Alcohol (PVA)-based phantom and training tool for use in simulated Transrectal Ultrasound (TRUS) guided prostate needle biopsy procedures
Trans-rectal ultrasound-guided needle biopsy is a well-established diagnosis technique for prostate cancer. To enhance the needle manoeuvring skills under ultrasound (US) guidance, it is preferable to train medical practitioners in needle biopsy on tissue-mimicking phantoms. This phantom should mimic the morphology as well as mechanical and acoustic properties of the human male pelvic region to provide a surgical experience and feedback. In this study, polyvinyl alcohol (PVA) was used and evaluated for prostate phantom development, that is stiffness tunable, US-compatible and durable phantom material. Three samples, each with 5%, 10%, and 15% concentration of PVA material, were prepared, and their mechanical and shrinkage characteristics were investigated. The anatomy of male pelvic region was used to develop an anatomically correct phantom. Later US-guided needle biopsy was performed on the phantom. The range of elastic moduli of the PVA samples was 2∼146 kPa. Their elastic moduli and volumes were found to remain statistically close from seventh to eighth freeze-thaw cycle (p>0.05). Initial US scans of the phantom resulted in satisfactory B-mode images, with a clear distinction between the prostate and its surrounding organs. This study demonstrated the applicability of PVA hydrogel as a phantom material for training in US-guided needle biopsy.
- 27 August 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 96 (1) , 46-52
A Poly-vinyl Alcohol (PVA)-based phantom and training tool for use in simulated Transrectal Ultrasound (TRUS) guided prostate needle biopsy procedures
Trans-rectal ultrasound-guided needle biopsy is a well-established diagnosis technique for prostate cancer. To enhance the needle manoeuvring skills under ultrasound (US) guidance, it is preferable to train medical practitioners in needle biopsy on tissue-mimicking phantoms. This phantom should mimic the morphology as well as mechanical and acoustic properties of the human male pelvic region to provide a surgical experience and feedback. In this study, polyvinyl alcohol (PVA) was used and evaluated for prostate phantom development, that is stiffness tunable, US-compatible and durable phantom material. Three samples, each with 5%, 10%, and 15% concentration of PVA material, were prepared, and their mechanical and shrinkage characteristics were investigated. The anatomy of male pelvic region was used to develop an anatomically correct phantom. Later US-guided needle biopsy was performed on the phantom. The range of elastic moduli of the PVA samples was 2∼146 kPa. Their elastic moduli and volumes were found to remain statistically close from seventh to eighth freeze-thaw cycle (p>0.05). Initial US scans of the phantom resulted in satisfactory B-mode images, with a clear distinction between the prostate and its surrounding organs. This study demonstrated the applicability of PVA hydrogel as a phantom material for training in US-guided needle biopsy.
- 1 April 2021
- Published by Elsevier in Ultrasonics
- Vol. 112, 106354
Towards practical implementation of the compressed sensing framework for multi-element synthetic transmit aperture imaging
- 1 April 2021
- Published by Elsevier in Ultrasonics
- Vol. 112, 106354
Towards practical implementation of the compressed sensing framework for multi-element synthetic transmit aperture imaging
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106293
Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system
- 1 February 2021
- Published by Elsevier in Ultrasonics
- Vol. 110, 106293
Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system
- 1 December 2020
- Published by Elsevier in Ultrasonics
- Vol. 108, 106183
Axial super-resolution in ultrasound imaging with application to non-destructive evaluation
- 1 December 2020
- Published by Elsevier in Ultrasonics
- Vol. 108, 106183
Axial super-resolution in ultrasound imaging with application to non-destructive evaluation