IHIgnace T. C. Hooge

Ignace T. C. Hooge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ignace T. C. Hooge has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    The fundamentals of eye tracking part 6: Working with areas of interest

    by Ignace T. C. Hooge, Marcus Nyström, Diederick C. Niehorster, Richard Andersson, Tom Foulsham, Antje Nuthmann, Roy S. Hessels

    Researchers use area of interest (AOI) analyses to interpret eye-tracking data. This article addresses four key aspects of AOI use: 1) how to report AOIs to support replicable analyses, 2) how to interpret AOI-related statistics, 3) methods for generating both static and dynamic AOIs, and 4) recent developments and future directions in AOI use. The article underscores the importance of aligning AOI design with the study’s conceptual and methodological foundations. It argues that critical decisions, such as the size, shape, and placement of AOIs, should be made early in the experimental design process and should involve eye-tracking data quality, the research question, participant tasks, and the nature of the visual stimulus. It also evaluates recent advances in AOI automation, outlining both their benefits and limitations. The article’s main message is that researchers should plan AOIs carefully and explain their choices openly so others can replicate the work.


  • Top Cited Papers
    Open Access

    The fundamentals of eye tracking part 2: From research question to operationalization

    by Ignace T. C. Hooge, Antje Nuthmann, Marcus Nyström, Diederick C. Niehorster, Gijs A. Holleman, Richard Andersson, Roy S. Hessels

    In this article, we discuss operationalizations and examples of experimental design in eye-tracking research. First, we distinguish direct operationalization for entities like saccades, which are closely aligned with their original concepts, and indirect operationalization for concepts not directly measurable, such as attention or mind-wandering. The latter relies on selecting a measurable proxy. Second, we highlight the variability in algorithmic operationalizations and emphasize that changing parameters can affect outcome measures. Transparency in reporting these parameters and algorithms is crucial for comparisons across studies. Third, we provide references to studies for common operationalizations in eye-tracking research and discuss key operationalizations in reading research. Fourth, the IO-model is introduced as a tool to help researchers operationalize difficult concepts. Finally, we present three example experiments with useful methods for eye-tracking research, encouraging readers to consider these examples for inspiration in their own experiments.


  • Open Access

    Eye tracker calibration: How well can humans refixate a target?

    by Ignace T. C. Hooge, Roy S. Hessels, Diederick C. Niehorster, Richard Andersson, Marta K. Skrok, Robert Konklewski, Patrycjusz Stremplewski, Maciej Nowakowski, Szymon Tamborski, Anna Szkulmowska, et al.

    Irrespective of the precision, the inaccuracy of a pupil-based eye tracker is about 0.5 $$^\circ $$ ∘ . This paper delves into two factors that potentially increase the inaccuracy of the gaze signal, namely, 1) Pupil-size changes and the pupil-size artefact (PSA) and 2) the putative inability of experienced individuals to precisely refixate a visual target. Experiment 1 utilizes a traditional pupil-CR eye tracker, while Experiment 2 employs a retinal eye tracker, the FreezeEye tracker, eliminating the pupil-based estimation. Results reveal that the PSA significantly affects gaze accuracy, introducing up to 0.5 $$^\circ $$ ∘ inaccuracies during calibration and validation. Corrections based on the relation between pupil size and apparent gaze shift substantially reduce inaccuracies, underscoring the PSA’s influence on eye-tracking quality. Conversely, Experiment 2 demonstrates humans’ precise refixation abilities, suggesting that the accuracy of the gaze signal is not limited by human refixation inconsistencies.


  • Open Access

    When knowing the activity is not enough to predict gaze

    by Andrea Ghiani, Daan Amelink, Eli Brenner, Ignace T. C. Hooge, Roy S. Hessels

    It is reasonable to assume that where people look in the world is largely determined by what they are doing. The reasoning is that the activity determines where it is useful to look at each moment in time. Assuming that it is vital to accurately judge the positions of the steps when navigating a staircase, it is surprising that people differ a lot in the extent to which they look at the steps. Apparently, some people consider the accuracy of peripheral vision, predictability of the step size, and feeling the edges of the steps with their feet to be good enough. If so, occluding part of the view of the staircase and making it more important to place one's feet gently might make it more beneficial to look directly at the steps before stepping onto them, so that people will more consistently look at many steps. We tested this idea by asking people to walk on staircases, either with or without a tray with two cups of water on it. When carrying the tray, people walked more slowly, but they shifted their gaze across steps in much the same way as they did when walking without the tray. They did not look at more steps. There was a clear positive correlation between the fraction of steps that people looked at when walking with and without the tray. Thus, the variability in the extent to which people look at the steps persists when one makes walking on the staircase more challenging.


  • Top Cited Papers
    Open Access

    What is a blink? Classifying and characterizing blinks in eye openness signals

    by Marcus Nyström, Richard Andersson, Diederick C. Niehorster, Roy S. Hessels, Ignace T. C. Hooge

    Blinks, the closing and opening of the eyelids, are used in a wide array of fields where human function and behavior are studied. In data from video-based eye trackers, blink rate and duration are often estimated from the pupil-size signal. However, blinks and their parameters can be estimated only indirectly from this signal, since it does not explicitly contain information about the eyelid position. We ask whether blinks detected from an eye openness signal that estimates the distance between the eyelids (EO blinks) are comparable to blinks detected with a traditional algorithm using the pupil-size signal (PS blinks) and how robust blink detection is when data quality is low. In terms of rate, there was an almost-perfect overlap between EO and PS blink (F1 score: 0.98) when the head was in the center of the eye tracker’s tracking range where data quality was high and a high overlap (F1 score 0.94) when the head was at the edge of the tracking range where data quality was worse. When there was a difference in blink rate between EO and PS blinks, it was mainly due to data loss in the pupil-size signal. Blink durations were about 60 ms longer in EO blinks compared to PS blinks. Moreover, the dynamics of EO blinks was similar to results from previous literature. We conclude that the eye openness signal together with our proposed blink detection algorithm provides an advantageous method to detect and describe blinks in greater detail.


  • Representative design: A realistic alternative to (systematic) integrative design

    by Gijs A. Holleman, Mandeep K. Dhami, Ignace T. C. Hooge, Roy S. Hessels

    We disagree with Almaatouq et al. that no realistic alternative exists to the “one-at-a-time” paradigm. Seventy years ago, Egon Brunswik introduced representative design, which offers a clear path to commensurability and generality. Almaatouq et al.'s integrative design cannot guarantee the external validity and generalizability of results which is sorely needed, while representative design tackles the problem head on.


  • Open Access

    Large eye–head gaze shifts measured with a wearable eye tracker and an industrial camera

    by Ignace T. C. Hooge, Diederick C. Niehorster, Marcus Nyström, Roy S. Hessels

    We built a novel setup to record large gaze shifts (up to 140 $$^\circ $$ ∘ ). The setup consists of a wearable eye tracker and a high-speed camera with fiducial marker technology to track the head. We tested our setup by replicating findings from the classic eye–head gaze shift literature. We conclude that our new inexpensive setup is good enough to investigate the dynamics of large eye–head gaze shifts. This novel setup could be used for future research on large eye–head gaze shifts, but also for research on gaze during e.g., human interaction. We further discuss reference frames and terminology in head-free eye tracking. Despite a transition from head-fixed eye tracking to head-free gaze tracking, researchers still use head-fixed eye movement terminology when discussing world-fixed gaze phenomena. We propose to use more specific terminology for world-fixed phenomena, including gaze fixation, gaze pursuit, and gaze saccade.


  • Open Access

    How robust are wearable eye trackers to slow and fast head and body movements?

    by Ignace T. C. Hooge, Diederick C. Niehorster, Roy S. Hessels, Jeroen S. Benjamins, Marcus Nyström

    How well can modern wearable eye trackers cope with head and body movement? To investigate this question, we asked four participants to stand still, walk, skip, and jump while fixating a static physical target in space. We did this for six different eye trackers. All the eye trackers were capable of recording gaze during the most dynamic episodes (skipping and jumping). The accuracy became worse as movement got wilder. During skipping and jumping, the biggest error was 5.8∘. However, most errors were smaller than 3∘. We discuss the implications of decreased accuracy in the context of different research scenarios.


  • Open Access

    The amplitude of small eye movements can be accurately estimated with video-based eye trackers

    by Marcus Nyström, Diederick C. Niehorster, Richard Andersson, Roy S. Hessels, Ignace T. C. Hooge

    Estimating the gaze direction with a digital video-based pupil and corneal reflection (P-CR) eye tracker is challenging partly since a video camera is limited in terms of spatial and temporal resolution, and because the captured eye images contain noise. Through computer simulation, we evaluated the localization accuracy of pupil-, and CR centers in the eye image for small eye rotations (≪ 1 deg). Results highlight how inaccuracies in center localization are related to 1) how many pixels the pupil and CR span in the eye camera image, 2) the method to compute the center of the pupil and CRs, and 3) the level of image noise. Our results provide a possible explanation to why the amplitude of small saccades may not be accurately estimated by many currently used video-based eye trackers. We conclude that eye movements with arbitrarily small amplitudes can be accurately estimated using the P-CR eye-tracking principle given that the level of image noise is low and the pupil and CR span enough pixels in the eye camera, or if localization of the CR is based on the intensity values in the eye image instead of a binary representation.


  • Open Access

    Fixation classification: how to merge and select fixation candidates

    by Ignace T. C. Hooge, Diederick C. Niehorster, Marcus Nyström, Richard Andersson, Roy S. Hessels

    Eye trackers are applied in many research fields (e.g., cognitive science, medicine, marketing research). To give meaning to the eye-tracking data, researchers have a broad choice of classification methods to extract various behaviors (e.g., saccade, blink, fixation) from the gaze signal. There is extensive literature about the different classification algorithms. Surprisingly, not much is known about the effect of fixation and saccade selection rules that are usually (implicitly) applied. We want to answer the following question: What is the impact of the selection-rule parameters (minimal saccade amplitude and minimal fixation duration) on the distribution of fixation durations? To answer this question, we used eye-tracking data with high and low quality and seven different classification algorithms. We conclude that selection rules play an important role in merging and selecting fixation candidates. For eye-tracking data with good-to-moderate precision (RMSD < 0.5∘), the classification algorithm of choice does not matter too much as long as it is sensitive enough and is followed by a rule that selects saccades with amplitudes larger than 1.0∘ and a rule that selects fixations with duration longer than 60 ms. Because of the importance of selection, researchers should always report whether they performed selection and the values of their parameters.