Shaaz Ghouse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shaaz Ghouse has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Paul A. Hooper
Department of Mechanical Engineering, Imperial College London, London, UK
4 shared publications Jonathan R.T. Jeffers
Department of Mechanical Engineering, Faculty of Engineering, Imperial College London, United Kingdom
3 shared publicationsSarat Babu
Betatype Ltd, Unit 4 Bow Enterprise Park, London, U.K.
3 shared publications- Justin Peter Cobb
MSK Lab, Imperial College London, London, UK
2 shared publications Kenneth Nai
2 shared publicationsNatalie Reznikov
Department of Materials, Department of Bioengineering and Institute for Biomedical Engineering, Imperial College London, U.K.
2 shared publications
Latest Publications
- Open Access
- 26 September 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (22) , e71274
3D‐Printed Titanium Gyroid Scaffold Structure Integrated With Tough Hybrid Materials for Cartilage Replacement
A novel hybrid implant for cartilage replacement was developed by integrating a silica‐poly(tetrahydrofuran) (SiO 2 ‐PolyTHF) sol–gel derived biomaterial into a 3D‐printed titanium (Ti) gyroid scaffold. Potential applications include knee cartilage or focal cartilage replacement. The hybrid material provides a cartilage‐mimicking, low‐friction bearing surface, while the Ti gyroid structure serves as a bone anchor to enable biological fixation through bone ingrowth (mechanical interlock). Integration of the hybrid into the Ti scaffold was optimized by tailoring the tetrahydrofuran:(3‐glycidyloxypropyl)trimethoxysilane (THF:GPTMS) ratio to control gelation kinetics and shrinkage‐induced stress during sol–gel processing. This processing strategy enabled crack‐free integration of the hybrid within the Ti gyroid scaffold and promoted robust interfacial mechanical performance. The hybrid–Ti interface exhibited strong mechanical interlocking, evidenced by mechanical testing in compression, shear, and cyclic loading over a 90 day period in PBS. Tribology testing against fresh bovine cartilage revealed that the hybrid/Ti scaffold maintained a low friction coefficient against the cartilage (~0.1), comparable to native cartilage on cartilage, and significantly lower than UHMWPE on cartilage. The results highlight the hybrid/Ti gyroid scaffold as a promising solution for cartilage replacement, with advantages in mechanical performance, cartilage‐mimicking tribology, and biological integration potential.
- 26 September 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (22) , e71274
Open Access3D‐Printed Titanium Gyroid Scaffold Structure Integrated With Tough Hybrid Materials for Cartilage Replacement
A novel hybrid implant for cartilage replacement was developed by integrating a silica‐poly(tetrahydrofuran) (SiO 2 ‐PolyTHF) sol–gel derived biomaterial into a 3D‐printed titanium (Ti) gyroid scaffold. Potential applications include knee cartilage or focal cartilage replacement. The hybrid material provides a cartilage‐mimicking, low‐friction bearing surface, while the Ti gyroid structure serves as a bone anchor to enable biological fixation through bone ingrowth (mechanical interlock). Integration of the hybrid into the Ti scaffold was optimized by tailoring the tetrahydrofuran:(3‐glycidyloxypropyl)trimethoxysilane (THF:GPTMS) ratio to control gelation kinetics and shrinkage‐induced stress during sol–gel processing. This processing strategy enabled crack‐free integration of the hybrid within the Ti gyroid scaffold and promoted robust interfacial mechanical performance. The hybrid–Ti interface exhibited strong mechanical interlocking, evidenced by mechanical testing in compression, shear, and cyclic loading over a 90 day period in PBS. Tribology testing against fresh bovine cartilage revealed that the hybrid/Ti scaffold maintained a low friction coefficient against the cartilage (~0.1), comparable to native cartilage on cartilage, and significantly lower than UHMWPE on cartilage. The results highlight the hybrid/Ti gyroid scaffold as a promising solution for cartilage replacement, with advantages in mechanical performance, cartilage‐mimicking tribology, and biological integration potential.
- Open Access
- 25 November 2022
- Published by Elsevier in Materials & Design
- Vol. 224, 111398
Process parameter sensitivity of the energy absorbing properties of additively manufactured metallic cellular materials
- 25 November 2022
- Published by Elsevier in Materials & Design
- Vol. 224, 111398
Open AccessProcess parameter sensitivity of the energy absorbing properties of additively manufactured metallic cellular materials
- Open Access
- 13 October 2022
- Published by Elsevier in Additive Manufacturing
- Vol. 60
Influence of laser shock peening on the residual stresses in additively manufactured 316L by Laser Powder Bed Fusion: A combined experimental–numerical study
- 13 October 2022
- Published by Elsevier in Additive Manufacturing
- Vol. 60
Open AccessInfluence of laser shock peening on the residual stresses in additively manufactured 316L by Laser Powder Bed Fusion: A combined experimental–numerical study
- Open Access
- 3 August 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 150, 105761
Additively manufactured lattice structures with controlled transverse isotropy for orthopedic porous implants
- 3 August 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 150, 105761
Open AccessAdditively manufactured lattice structures with controlled transverse isotropy for orthopedic porous implants
- Open Access
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104784
Laser powder bed fusion of porous graded structures: A comparison between computational and experimental analysis
- 1 November 2021
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 123, 104784
Open AccessLaser powder bed fusion of porous graded structures: A comparison between computational and experimental analysis
- Top Cited PapersOpen Access
- 1 June 2019
- Published by Elsevier in Applied Materials Today
- Vol. 15, 377-388
The design and in vivo testing of a locally stiffness-matched porous scaffold
- 1 June 2019
- Published by Elsevier in Applied Materials Today
- Vol. 15, 377-388
Top Cited PapersOpen AccessThe design and in vivo testing of a locally stiffness-matched porous scaffold
- Open Access
- 1 February 2019
- Published by Elsevier in Biomaterials
- Vol. 194, 183-194
Individual response variations in scaffold-guided bone regeneration are determined by independent strain- and injury-induced mechanisms
- 1 February 2019
- Published by Elsevier in Biomaterials
- Vol. 194, 183-194
Open AccessIndividual response variations in scaffold-guided bone regeneration are determined by independent strain- and injury-induced mechanisms
- Open Access
- 1 August 2018
- Published by Elsevier in Additive Manufacturing
- Vol. 22, 290-301
The influence of laser parameters, scanning strategies and material on the fatigue strength of a stochastic porous structure
- 1 August 2018
- Published by Elsevier in Additive Manufacturing
- Vol. 22, 290-301
Open AccessThe influence of laser parameters, scanning strategies and material on the fatigue strength of a stochastic porous structure
- Open Access
- 22 November 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (5) , 1508-1518
Additive manufactured push‐fit implant fixation with screw‐strength pull out
Additive manufacturing offers exciting new possibilities for improving long‐term metallic implant fixation in bone through enabling open porous structures for bony ingrowth. The aim of this research was to investigate how the technology could also improve initial fixation, a precursor to successful long‐term fixation. A new barbed fixation mechanism, relying on flexible struts was proposed and manufactured as a push‐fit peg. The technology was optimized using a synthetic bone model and compared with conventional press‐fit peg controls tested over a range of interference fits. Optimum designs, achieving maximum pull‐out force, were subsequently tested in a cadaveric femoral condyle model. The barbed fixation surface provided more than double the pull‐out force for less than a third of the insertion force compared to the best performing conventional press‐fit peg (p < 0.001). Indeed, it provided screw‐strength pull out from a push‐fit device (1,124 ± 146 N). This step change in implant fixation potential offers new capabilities for low profile, minimally invasive implant design, while providing new options to simplify surgery, allowing for one‐piece push‐fit components with high levels of initial stability. © 2017 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:1508–1518, 2018.
- 22 November 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (5) , 1508-1518
Open AccessAdditive manufactured push‐fit implant fixation with screw‐strength pull out
Additive manufacturing offers exciting new possibilities for improving long‐term metallic implant fixation in bone through enabling open porous structures for bony ingrowth. The aim of this research was to investigate how the technology could also improve initial fixation, a precursor to successful long‐term fixation. A new barbed fixation mechanism, relying on flexible struts was proposed and manufactured as a push‐fit peg. The technology was optimized using a synthetic bone model and compared with conventional press‐fit peg controls tested over a range of interference fits. Optimum designs, achieving maximum pull‐out force, were subsequently tested in a cadaveric femoral condyle model. The barbed fixation surface provided more than double the pull‐out force for less than a third of the insertion force compared to the best performing conventional press‐fit peg (p < 0.001). Indeed, it provided screw‐strength pull out from a push‐fit device (1,124 ± 146 N). This step change in implant fixation potential offers new capabilities for low profile, minimally invasive implant design, while providing new options to simplify surgery, allowing for one‐piece push‐fit components with high levels of initial stability. © 2017 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:1508–1518, 2018.
- Open Access
- 1 October 2017
- Published by Elsevier in Materials & Design
- Vol. 131, 498-508
The influence of laser parameters and scanning strategies on the mechanical properties of a stochastic porous material
- 1 October 2017
- Published by Elsevier in Materials & Design
- Vol. 131, 498-508
Open AccessThe influence of laser parameters and scanning strategies on the mechanical properties of a stochastic porous material