MGMallikarjunarao Ganesana

Mallikarjunarao Ganesana

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mallikarjunarao Ganesana has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Focused Ultrasound Modulates Dopamine in a Mesolimbic Reward Circuit

    by Greatness Olaitan, Mallikarjunarao Ganesana, Andrew Strohman, Wendy J. Lynch, Wynn Legon, B. Jill Venton

    Dopamine is a neurotransmitter that plays a significant role in reward and motivation. Dysfunction in the mesolimbic dopamine pathway has been linked to a variety of psychiatric disorders, including addiction. Low‐intensity focused ultrasound (LIFU) has demonstrated effects on brain activity, but how LIFU affects dopamine neurotransmission is not known. Here, we applied three different intensities (6.5, 13, and 26 W/cm 2 I SPPA ) of 2‐min LIFU to the prelimbic cortex (PLC) and measured dopamine in the nucleus accumbens (NAc) core using fast‐scan cyclic voltammetry. Two minutes of LIFU sonication at 13 W/cm 2 to the PLC significantly reduced dopamine release by ~50% for up to 2 h. However, double the intensity (26 W/cm 2 ) resulted in less inhibition (~30%), and half the intensity (6.5 W/cm 2 ) did not result in any inhibition of dopamine. Anatomical controls applying LIFU to the primary somatosensory cortex did not change NAc core dopamine, and applying LIFU to the PLC did not affect dopamine release in the caudate or NAc shell. Histological evaluations showed no evidence of cell damage or death. Modeling temperature rise demonstrates a maximum temperature change of 0.5°C with 13 W/cm 2 , suggesting that modulation is not due to thermal mechanisms. These studies show that LIFU at a moderate intensity provides a noninvasive, high spatial resolution means to modulate specific mesolimbic circuits that could be used in future studies to target and repair pathways that are dysfunctional in addiction and other psychiatric diseases. image


  • Open Access

    Focused Ultrasound Modulates Dopamine in a Mesolimbic Reward Circuit

    by Greatness O. Olaitan, Mallikarjunarao Ganesana, Andrew Strohman, Wendy J. Lynch, Wynn Legon, B. Jill Venton

    Dopamine is a neurotransmitter that plays a significant role in reward and motivation. Dysfunction in the mesolimbic dopamine pathway has been linked to a variety of psychiatric disorders, including addiction. Low-intensity focused ultrasound (LIFU) has demonstrated effects on brain activity, but how LIFU affects dopamine neurotransmission is not known. Here, we applied three different intensities (6.5, 13, and 26 W/cm 2 I sppa ) of 2-minute LIFU to the prelimbic region (PLC) and measured dopamine in the nucleus accumbens (NAc) core using fast-scan cyclic voltammetry. Two minutes of LIFU sonication at 13 W/cm 2 to the PLC significantly reduced dopamine release by ∼ 50% for up to 2 hours. However, double the intensity (26 W/cm 2 ) resulted in less inhibition (∼30%), and half the intensity (6.5 W/cm 2 ) did not result in any inhibition of dopamine. Anatomical controls applying LIFU to the primary somatosensory cortex did not change NAc core dopamine, and applying LIFU to the PLC did not affect dopamine release in the caudate or NAc shell. Histological evaluations showed no evidence of cell damage or death. Modeling of temperature rise demonstrates a maximum temperature change of 0.5°C with 13 W/cm 2 , suggesting that modulation is not due to thermal mechanisms. These studies show that LIFU at a moderate intensity provides a noninvasive, high spatial resolution means to modulate specific mesolimbic circuits that could be used in future studies to target and repair pathways that are dysfunctional in addiction and other psychiatric diseases.


  • Open Access

    Antioxidant Enzyme-Mimetic Activity and Neuroprotective Effects of Cerium Oxide Nanoparticles Stabilized with Various Ratios of Citric Acid and EDTA

    by Ana Y. Estevez, Mallikarjunarao Ganesana, John F. Trentini, James E. Olson, Guangze Li, Yvonne O. Boateng, Jennifer M. Lipps, Sarah E. R. Yablonski, William T. Donnelly, James C. Leiter, et al.

    Cerium oxide (CeO2) nanoparticles (CeNPs) are potent antioxidants that are being explored as potential therapies for diseases in which oxidative stress plays an important pathological role. However, both beneficial and toxic effects of CeNPs have been reported, and the method of synthesis as well as physico-chemical, biological, and environmental factors can impact the ultimate biological effects of CeNPs. In the present study, we explored the effect of different ratios of citric acid (CA) and EDTA (CA/EDTA), which are used as stabilizers during synthesis of CeNPs, on the antioxidant enzyme-mimetic and biological activity of the CeNPs. We separated the CeNPs into supernatant and pellet fractions and used commercially available enzymatic assays to measure the catalase-, superoxide dismutase (SOD)-, and oxidase-mimetic activity of each fraction. We tested the effects of these CeNPs in a mouse hippocampal brain slice model of ischemia to induce oxidative stress where the fluorescence indicator SYTOX green was used to assess cell death. Our results demonstrate that CeNPs stabilized with various ratios of CA/EDTA display different enzyme-mimetic activities. CeNPs with intermediate CA/EDTA stabilization ratios demonstrated greater neuroprotection in ischemic mouse brain slices, and the neuroprotective activity resides in the pellet fraction of the CeNPs. The neuroprotective effects of CeNPs stabilized with equal proportions of CA/EDTA (50/50) were also demonstrated in two other models of ischemia/reperfusion in mice and rats. Thus, CeNPs merit further development as a neuroprotective therapy for use in diseases associated with oxidative stress in the nervous system.


  • 3D‐Printed Carbon Electrodes for Neurotransmitter Detection

    by Cheng Yang, Qun Cao, Pumidech Puthongkham, Scott T. Lee, Mallikarjunarao Ganesana, Nickolay V. Lavrik, B. Jill Venton

    Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 nm(sphere) and 10±2 nm(cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.


  • 3D‐Printed Carbon Electrodes for Neurotransmitter Detection

    by Cheng Yang, Qun Cao, Pumidech Puthongkham, Scott T. Lee, Mallikarjunarao Ganesana, Nickolay V. Lavrik, B. Jill Venton

    Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 nm(sphere) and 10±2 nm(cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.