Pedro Moreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pedro Moreira has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Junichi Tokuda
Department of Radiology, Harvard Medical School, Boston, MA, USA
6 shared publications - Mariana Costa Bernardes
Université Montpellier 2, LIRMM, 161 rue Ada, 34095, France
6 shared publications - Clare Tempany
Brigham and Women's Hospital, Boston, MA
5 shared publications Junichi Tokuda
Department of Radiology, Brigham and Womens Hospital, Harvard Medical School, Boston, MA, USA
5 shared publicationsKemal Tuncali
Department of Radiology, Brigham & Women’s Hospital, Harvard Medical School, Boston, USA
5 shared publications- Kemal Tuncali
Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis St., Boston, MA, USA
5 shared publications
Latest Publications
- 23 March 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 11 (01n02)
Clinical Validation of a Novel Robotic Device for MR-guided Prostate Biopsy: Initial Patient Experience
Magnetic resonance imaging (MRI)-guided transperineal targeted prostate biopsy has the potential to provide a precise cancer diagnosis. However, it is challenged by targeting errors and needle deflection. The main issue is that the traditional needle guides have limited degrees of freedom (DoF) and therefore restrict insertion path options. Thus, the targeting error can be larger than 5[ ]mm. This study evaluates the performance of a custom-built 4-DoF needle guiding device designed to enable alternative insertion paths. The 4-DoF Smart Template was designed to improve image quality and stability, including redesigned fiducials and titanium positioning frames. Four MRI-guided biopsy cases were conducted. Targets were identified on T2-weighted images, and insertion paths were planned and adjusted to avoid critical structures. The targeting error was measured as the in-plane distance between the target and the actual needle position. The average targeting error of the best insertion attempt was 3.7[ ]mm ± 2.6[ ]mm (mean ± standard deviation). When discarding the case where the device had to be removed due to patient anatomy, the average targeting error was reduced to 2.7[ ]mm ± 1.1[ ]mm. No adverse events were reported. The new 4-DoF Smart Template device has demonstrated improved accuracy as compared to the traditional needle guide device, successfully reaching the target location with just one insertion in four out of six targets.
- 23 March 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 11 (01n02)
Clinical Validation of a Novel Robotic Device for MR-guided Prostate Biopsy: Initial Patient Experience
Magnetic resonance imaging (MRI)-guided transperineal targeted prostate biopsy has the potential to provide a precise cancer diagnosis. However, it is challenged by targeting errors and needle deflection. The main issue is that the traditional needle guides have limited degrees of freedom (DoF) and therefore restrict insertion path options. Thus, the targeting error can be larger than 5[ ]mm. This study evaluates the performance of a custom-built 4-DoF needle guiding device designed to enable alternative insertion paths. The 4-DoF Smart Template was designed to improve image quality and stability, including redesigned fiducials and titanium positioning frames. Four MRI-guided biopsy cases were conducted. Targets were identified on T2-weighted images, and insertion paths were planned and adjusted to avoid critical structures. The targeting error was measured as the in-plane distance between the target and the actual needle position. The average targeting error of the best insertion attempt was 3.7[ ]mm ± 2.6[ ]mm (mean ± standard deviation). When discarding the case where the device had to be removed due to patient anatomy, the average targeting error was reduced to 2.7[ ]mm ± 1.1[ ]mm. No adverse events were reported. The new 4-DoF Smart Template device has demonstrated improved accuracy as compared to the traditional needle guide device, successfully reaching the target location with just one insertion in four out of six targets.
- 3 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (5) , 055003
AI-assisted cryo-dose estimation and tissue injury modeling for assessing side effects in MRI-guided prostate cryoablation: a retrospective study
Objective. Focal therapy offers a middle ground between active surveillance and whole-gland treatment for patients with low- and intermediate-risk prostate cancer, aiming to eliminate tumor tissue while preserving surrounding structures. Among available focal therapy approaches, magnetic resonance imaging (MRI)-guided focal cryoablation offers some technical advantages, including real-time monitoring of iceball formation and intraoperative images with excellent soft-tissue contrast. Despite its minimally invasive nature, prior studies have reported postoperative urinary and sexual dysfunction, raising concerns about unintended injury to critical anatomical structures such as the external urethral sphincter (EUS) and neurovascular bundles (NVBs). However, the direct relationship between anatomical injury and postoperative symptoms remains unclear. We hypothesize that damage to the EUS or NVBs during MRI-guided focal cryoablation increases the risk of postoperative urinary or erectile dysfunction. Approach. We analyzed 402 multi-slice MRI image sets from 42 procedures. We developed an AI-assisted tool for automatic segmentation of anatomical structures and iceballs. Quantitative metrics were proposed to estimate tissue damage based on spatial overlap, exposure time, and temperature dynamics. These metrics were then statistically correlated with postoperative urinary and erectile outcomes. Main results. Significant associations were observed between injury metrics and postoperative dysfunctions, with EUS involvement predictive of urinary dysfunction in both time-based ( p < 0.05 ) and temperature-proxy models ( p < 0.05 ) , and NVB involvement associated with erectile dysfunction in the time-based model ( p < 0.05 ) . Significance. Our findings demonstrate that EUS and NVB injuries are quantifiable predictors of postoperative morbidity with medium-to-large effect sizes. The developed AI-assisted framework supports objective evaluation of cryo-dose and establishes a preliminary basis for a quantitative injury metric designed to minimize side effects and enhance the safety of focal cryoablation.
- 3 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (5) , 055003
AI-assisted cryo-dose estimation and tissue injury modeling for assessing side effects in MRI-guided prostate cryoablation: a retrospective study
Objective. Focal therapy offers a middle ground between active surveillance and whole-gland treatment for patients with low- and intermediate-risk prostate cancer, aiming to eliminate tumor tissue while preserving surrounding structures. Among available focal therapy approaches, magnetic resonance imaging (MRI)-guided focal cryoablation offers some technical advantages, including real-time monitoring of iceball formation and intraoperative images with excellent soft-tissue contrast. Despite its minimally invasive nature, prior studies have reported postoperative urinary and sexual dysfunction, raising concerns about unintended injury to critical anatomical structures such as the external urethral sphincter (EUS) and neurovascular bundles (NVBs). However, the direct relationship between anatomical injury and postoperative symptoms remains unclear. We hypothesize that damage to the EUS or NVBs during MRI-guided focal cryoablation increases the risk of postoperative urinary or erectile dysfunction. Approach. We analyzed 402 multi-slice MRI image sets from 42 procedures. We developed an AI-assisted tool for automatic segmentation of anatomical structures and iceballs. Quantitative metrics were proposed to estimate tissue damage based on spatial overlap, exposure time, and temperature dynamics. These metrics were then statistically correlated with postoperative urinary and erectile outcomes. Main results. Significant associations were observed between injury metrics and postoperative dysfunctions, with EUS involvement predictive of urinary dysfunction in both time-based ( p < 0.05 ) and temperature-proxy models ( p < 0.05 ) , and NVB involvement associated with erectile dysfunction in the time-based model ( p < 0.05 ) . Significance. Our findings demonstrate that EUS and NVB injuries are quantifiable predictors of postoperative morbidity with medium-to-large effect sizes. The developed AI-assisted framework supports objective evaluation of cryo-dose and establishes a preliminary basis for a quantitative injury metric designed to minimize side effects and enhance the safety of focal cryoablation.
- Open Access
- 29 August 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (11) , 3237-3246
Image-Guided Adaptive Cryotherapy for Prostate Cancer Treatment
Purpose: Focal cryoablation is an effective treatment for localized and recurrent prostate cancer, offering reduced risks of side effects. However, treatment success depends on physician experience, as intraprocedural adjustments are required due to needle deflection. To determine whether an image-guided adaptive treatment strategy could reduce the required years of experience, we developed Image-guided Adaptive Cryotherapy (ImAC). We hypothesize that ImAC can be successfully implemented in MRI-guided cryotherapy to optimize needle placement. To test this hypothesis, we conducted a retrospective study comparing the performance of an experienced physician to that of ImAC. Methods: ImAC was designed to calculate the best subsequent needle location while accounting for needle deflection and iceball formation. After development, its performance was evaluated by simulating 21 needle insertions. Results: We found that ImAC achieved a higher median minimum ablation margin than the physician (5.0 vs 3.4 mm) while maintaining similar needle placement adjustments (± 7.5 mm). Conclusion: These results suggest that ImAC has the potential to optimize needle placement and may reduce the years of experience required for effective cryoablation.
- 29 August 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (11) , 3237-3246
Open AccessImage-Guided Adaptive Cryotherapy for Prostate Cancer Treatment
Purpose: Focal cryoablation is an effective treatment for localized and recurrent prostate cancer, offering reduced risks of side effects. However, treatment success depends on physician experience, as intraprocedural adjustments are required due to needle deflection. To determine whether an image-guided adaptive treatment strategy could reduce the required years of experience, we developed Image-guided Adaptive Cryotherapy (ImAC). We hypothesize that ImAC can be successfully implemented in MRI-guided cryotherapy to optimize needle placement. To test this hypothesis, we conducted a retrospective study comparing the performance of an experienced physician to that of ImAC. Methods: ImAC was designed to calculate the best subsequent needle location while accounting for needle deflection and iceball formation. After development, its performance was evaluated by simulating 21 needle insertions. Results: We found that ImAC achieved a higher median minimum ablation margin than the physician (5.0 vs 3.4 mm) while maintaining similar needle placement adjustments (± 7.5 mm). Conclusion: These results suggest that ImAC has the potential to optimize needle placement and may reduce the years of experience required for effective cryoablation.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 8975-8982
In Vivo Feasibility Study: Evaluating Autonomous Data-Driven Robotic Needle Trajectory Correction in MRI-Guided Transperineal Procedures
This letter addresses the targeting challenges in MRI-guided transperineal needle placement for prostate cancer (PCa) diagnosis and treatment, a procedure where accuracy is crucial for effective outcomes. We introduce a parameter-agnostic trajectory correction approach incorporating a data-driven closed-loop strategy by radial displacement and an FBG-based shape sensing to enable autonomous needle steering. In an animal study designed to emulate clinical complexity and assess MRI compatibility through a PCa mock biopsy procedure, our approach demonstrated a significant improvement in targeting accuracy (p < 0.05), with mean target error of only 2.2 $\pm$ 1.9 mm on first insertion attempts, without needle reinsertions. To the best of our knowledge, this work represents the first in vivo evaluation of robotic needle steering with FBG-sensor feedback, marking a significant step towards its clinical translation.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 8975-8982
In Vivo Feasibility Study: Evaluating Autonomous Data-Driven Robotic Needle Trajectory Correction in MRI-Guided Transperineal Procedures
This letter addresses the targeting challenges in MRI-guided transperineal needle placement for prostate cancer (PCa) diagnosis and treatment, a procedure where accuracy is crucial for effective outcomes. We introduce a parameter-agnostic trajectory correction approach incorporating a data-driven closed-loop strategy by radial displacement and an FBG-based shape sensing to enable autonomous needle steering. In an animal study designed to emulate clinical complexity and assess MRI compatibility through a PCa mock biopsy procedure, our approach demonstrated a significant improvement in targeting accuracy (p < 0.05), with mean target error of only 2.2 $\pm$ 1.9 mm on first insertion attempts, without needle reinsertions. To the best of our knowledge, this work represents the first in vivo evaluation of robotic needle steering with FBG-sensor feedback, marking a significant step towards its clinical translation.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18359-18371
Hybrid Deep Learning and Model-Based Needle Shape Prediction
Needle insertion using flexible bevel-tip needles is a common minimally invasive surgical technique for prostate cancer interventions. Flexible, asymmetric bevel-tip needles enable physicians for complex needle steering techniques to avoid sensitive anatomical structures during needle insertion. For accurate placement of the needle, predicting the trajectory of these needles intraoperatively would greatly reduce the need for frequently needle reinsertions, thus improving patient comfort and positive outcomes. However, predicting the trajectory of the needle during insertion is a complex task that has yet to be solved due to random needle–tissue interactions. In this article, we present and validate, for the first time, a hybrid deep learning and model-based approach to handle the intraoperative needle shape prediction problem through leveraging a validated Lie-group theoretic model for needle shape representation. Furthermore, we present a novel self-supervised learning (SSL) and method in conjunction with the Lie-group shape model for training these networks in the absence of data, enabling further refinement of these networks with transfer learning (TL). Needle shape prediction was performed in single-layer and double-layer homogeneous phantom tissue for C- and S-shaped needle insertions. Our method demonstrates an average root-mean-square prediction error of 1.03 mm over a dataset containing approximately 3000 prediction samples with the maximum prediction steps of 110 mm.
- 12 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18359-18371
Hybrid Deep Learning and Model-Based Needle Shape Prediction
Needle insertion using flexible bevel-tip needles is a common minimally invasive surgical technique for prostate cancer interventions. Flexible, asymmetric bevel-tip needles enable physicians for complex needle steering techniques to avoid sensitive anatomical structures during needle insertion. For accurate placement of the needle, predicting the trajectory of these needles intraoperatively would greatly reduce the need for frequently needle reinsertions, thus improving patient comfort and positive outcomes. However, predicting the trajectory of the needle during insertion is a complex task that has yet to be solved due to random needle–tissue interactions. In this article, we present and validate, for the first time, a hybrid deep learning and model-based approach to handle the intraoperative needle shape prediction problem through leveraging a validated Lie-group theoretic model for needle shape representation. Furthermore, we present a novel self-supervised learning (SSL) and method in conjunction with the Lie-group shape model for training these networks in the absence of data, enabling further refinement of these networks with transfer learning (TL). Needle shape prediction was performed in single-layer and double-layer homogeneous phantom tissue for C- and S-shaped needle insertions. Our method demonstrates an average root-mean-square prediction error of 1.03 mm over a dataset containing approximately 3000 prediction samples with the maximum prediction steps of 110 mm.
- 24 May 2023
- Published by Elsevier in Academic Radiology
- Vol. 30 (Suppl 1) , S14-S20
AI-Based Isotherm Prediction for Focal Cryoablation of Prostate Cancer
- 24 May 2023
- Published by Elsevier in Academic Radiology
- Vol. 30 (Suppl 1) , S14-S20
AI-Based Isotherm Prediction for Focal Cryoablation of Prostate Cancer
- 15 May 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (10) , 105016
Data-driven adaptive needle insertion assist for transperineal prostate interventions
Objective. Clinical outcomes of transperineal prostate interventions, such as biopsy, thermal ablations, and brachytherapy, depend on accurate needle placement for effectiveness. However, the accurate placement of a long needle, typically 150–200 mm in length, is challenging due to needle deviation induced by needle-tissue interaction. While several approaches for needle trajectory correction have been studied, many of them do not translate well to practical applications due to the use of specialized needles not yet approved for clinical use, or to relying on needle-tissue models that need to be tailored to individual patients. Approach. In this paper, we present a robot-assisted collaborative needle insertion method that only requires an actuated passive needle guide and a conventional needle. The method is designed to assist a physician inserting a needle manually through a needle guide. If the needle is deviated from the intended path, actuators shifts the needle radially in order to steer the needle trajectory and compensate for needle deviation adaptively. The needle guide is controlled by a new data-driven algorithm which does not require a priori information about needle or tissue properties. The method was evaluated in experiments with both in vitro and ex vivo phantoms. Main results. The experiments in ex vivo tissue reported a mean final placement error of 0.36 mm with a reduction of 96.25% of placement error when compared to insertions without the use of assistive correction. Significance. Presented results show that the proposed closed-loop formulation can be successfully used to correct needle deflection during collaborative manual insertion with potential to be easily translated into clinical application.
- 15 May 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (10) , 105016
Data-driven adaptive needle insertion assist for transperineal prostate interventions
Objective. Clinical outcomes of transperineal prostate interventions, such as biopsy, thermal ablations, and brachytherapy, depend on accurate needle placement for effectiveness. However, the accurate placement of a long needle, typically 150–200 mm in length, is challenging due to needle deviation induced by needle-tissue interaction. While several approaches for needle trajectory correction have been studied, many of them do not translate well to practical applications due to the use of specialized needles not yet approved for clinical use, or to relying on needle-tissue models that need to be tailored to individual patients. Approach. In this paper, we present a robot-assisted collaborative needle insertion method that only requires an actuated passive needle guide and a conventional needle. The method is designed to assist a physician inserting a needle manually through a needle guide. If the needle is deviated from the intended path, actuators shifts the needle radially in order to steer the needle trajectory and compensate for needle deviation adaptively. The needle guide is controlled by a new data-driven algorithm which does not require a priori information about needle or tissue properties. The method was evaluated in experiments with both in vitro and ex vivo phantoms. Main results. The experiments in ex vivo tissue reported a mean final placement error of 0.36 mm with a reduction of 96.25% of placement error when compared to insertions without the use of assistive correction. Significance. Presented results show that the proposed closed-loop formulation can be successfully used to correct needle deflection during collaborative manual insertion with potential to be easily translated into clinical application.
- 4 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (2) , 335-342
Motorized Template for MRI-Guided Focal Cryoablation of Prostate Cancer
MR-guided focal cryoablation of prostate cancer has often been selected as a minimally-invasive treatment option. Placing multiple cryo-needles accurately to form an ablation volume that adequately covers the target volume is crucial for better oncological/functional outcomes. This paper presents an MRI-compatible system combining a motorized tilting grid template with insertion depth sensing capabilities, enabling the physician to precisely place the cryo-needles into the desired location. In vivo animal study in a swine model (3 animals) was performed to test the device performance including targeting accuracy and the procedure workflow. The study showed that the insertion depth feedback improved the 3D targeting accuracy when compared to the conventional insertion technique (7.4 mm vs. 11.2 mm, $\text{p}=$ 0.04). All three cases achieved full iceball coverage without repositioning the cryo-needles. The results demonstrate the advantages of the motorized tilting mechanism and real-time insertion depth feedback, as well as the feasibility of the proposed workflow for MRI-guided focal cryoablation of prostate cancer.
- 4 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (2) , 335-342
Motorized Template for MRI-Guided Focal Cryoablation of Prostate Cancer
MR-guided focal cryoablation of prostate cancer has often been selected as a minimally-invasive treatment option. Placing multiple cryo-needles accurately to form an ablation volume that adequately covers the target volume is crucial for better oncological/functional outcomes. This paper presents an MRI-compatible system combining a motorized tilting grid template with insertion depth sensing capabilities, enabling the physician to precisely place the cryo-needles into the desired location. In vivo animal study in a swine model (3 animals) was performed to test the device performance including targeting accuracy and the procedure workflow. The study showed that the insertion depth feedback improved the 3D targeting accuracy when compared to the conventional insertion technique (7.4 mm vs. 11.2 mm, $\text{p}=$ 0.04). All three cases achieved full iceball coverage without repositioning the cryo-needles. The results demonstrate the advantages of the motorized tilting mechanism and real-time insertion depth feedback, as well as the feasibility of the proposed workflow for MRI-guided focal cryoablation of prostate cancer.
- Open Access
- 30 June 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (1) , 461-471
Promoting the use of the PI-QUAL score for prostate MRI quality: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship
Objectives: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant’s ability to apply PI-QUAL. Methods: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. Results: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50–0.66]) to post-teaching (0.96 [0.92–0.98]), an improvement of 0.37 [0.21–0.41] (p < 0.001). Conclusions: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. Key Points: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.
- 30 June 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (1) , 461-471
Open AccessPromoting the use of the PI-QUAL score for prostate MRI quality: results from the ESOR Nicholas Gourtsoyiannis teaching fellowship
Objectives: The Prostate Imaging Quality (PI-QUAL) score is a new metric to evaluate the diagnostic quality of multiparametric magnetic resonance imaging (MRI) of the prostate. This study assesses the impact of an intervention, namely a prostate MRI quality training lecture, on the participant’s ability to apply PI-QUAL. Methods: Sixteen participants (radiologists, urologists, physicists, and computer scientists) of varying experience in reviewing diagnostic prostate MRI all assessed the image quality of ten examinations from different vendors and machines. Then, they attended a dedicated lecture followed by a hands-on workshop on MRI quality assessment using the PI-QUAL score. Five scans assessed by the participants were evaluated in the workshop using the PI-QUAL score for teaching purposes. After the course, the same participants evaluated the image quality of a new set of ten scans applying the PI-QUAL score. Results were assessed using receiver operating characteristic analysis. The reference standard was the PI-QUAL score assessed by one of the developers of PI-QUAL. Results: There was a significant improvement in average area under the curve for the evaluation of image quality from baseline (0.59 [95 % confidence intervals: 0.50–0.66]) to post-teaching (0.96 [0.92–0.98]), an improvement of 0.37 [0.21–0.41] (p < 0.001). Conclusions: A teaching course (dedicated lecture + hands-on workshop) on PI-QUAL significantly improved the application of this scoring system to assess the quality of prostate MRI examinations. Key Points: • A significant improvement in the application of PI-QUAL for the assessment of prostate MR image quality was observed after an educational intervention. • Appropriate training on image quality can be delivered to those involved in the acquisition and interpretation of prostate MRI. • Further investigation will be needed to understand the impact on improving the acquisition of high-quality diagnostic prostate MR examinations.