Jose Manuel Udias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jose Manuel Udias has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Joaquin Lopez Herraiz
Nuclear Physics Group and IPARCOS Complutense University of Madrid, Madrid, Spain, Madrid, Comunidad de Madrid, 28040, SPAIN
78 shared publications - Juan Antonio Caballero
Departamento de Física Atómica, Molecular y Nuclear, Universidad de Sevilla, 41080 Sevilla, Spain
51 shared publications - Luis Mario Fraile
Universidad Complutense de Madrid
46 shared publications - Manuel Desco
Universidad Carlos III de Madrid
45 shared publications - Elvira Moya de Guerra
Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Facultad de Ciencias Físicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
40 shared publications - Samuel España
Grupo de Física Nuclear, EMFTEL & IPARCOS, Universidad Complutense de Madrid, Pl. de las Ciencias, 1, Moncloa - Aravaca, 28040 Madrid, Madrid, 28040, SPAIN
38 shared publications
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1095
Performance evaluation of fast photomultiplier tubes for LaBr3(Ce) detection systems
- 24 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1095
Open AccessPerformance evaluation of fast photomultiplier tubes for LaBr3(Ce) detection systems
- 19 August 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (3) , 033006
Two-body current and axial form factor effects in charged-current quasielastic neutrino-nucleus scattering within the NEUT event generator
We present a charged-current quasielastic neutrino-nucleus scattering model based on an unfactorized representation of the spectral function, employing relativistic momentum distributions for bound nucleons and the relativistic distorted-wave impulse approximation with an energy-dependent relativistic potential to describe the scattered nucleon. The model incorporates two-body meson-exchange currents contributing to one-particle-one-hole final states and tests several axial form factor parametrizations, including recent LQCD and MINERvA fits. It is implemented in the NEUT event generator and benchmarked against T2K and MINERvA ${\ensuremath{\nu}}_{\ensuremath{\mu}}\text{\ensuremath{-}}^{12}\mathrm{C}$ $\mathrm{CC}0\ensuremath{\pi}$ measurements. We find that two-body meson-exchange currents lead to a sizeable increase of the total cross section, arising from an enhancement of the transverse response, which is the dominant component in charged-current neutrino scattering. On the other hand, recent fits of the axial form factor predict larger values than the standard dipole form, yielding a systematic enhancement of the cross section. The $\mathrm{LQCD}+\mathrm{MINERvA}$ parametrization tends to overestimate the data, while the MINERvA-only fit provides a more moderate increase. Overall, no single configuration consistently provides the best agreement with the different datasets.- 19 August 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 114 (3) , 033006
Two-body current and axial form factor effects in charged-current quasielastic neutrino-nucleus scattering within the NEUT event generator
We present a charged-current quasielastic neutrino-nucleus scattering model based on an unfactorized representation of the spectral function, employing relativistic momentum distributions for bound nucleons and the relativistic distorted-wave impulse approximation with an energy-dependent relativistic potential to describe the scattered nucleon. The model incorporates two-body meson-exchange currents contributing to one-particle-one-hole final states and tests several axial form factor parametrizations, including recent LQCD and MINERvA fits. It is implemented in the NEUT event generator and benchmarked against T2K and MINERvA ${\ensuremath{\nu}}_{\ensuremath{\mu}}\text{\ensuremath{-}}^{12}\mathrm{C}$ $\mathrm{CC}0\ensuremath{\pi}$ measurements. We find that two-body meson-exchange currents lead to a sizeable increase of the total cross section, arising from an enhancement of the transverse response, which is the dominant component in charged-current neutrino scattering. On the other hand, recent fits of the axial form factor predict larger values than the standard dipole form, yielding a systematic enhancement of the cross section. The $\mathrm{LQCD}+\mathrm{MINERvA}$ parametrization tends to overestimate the data, while the MINERvA-only fit provides a more moderate increase. Overall, no single configuration consistently provides the best agreement with the different datasets.- Open Access
- 4 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6706
Condensed-History GPU Positron Range Simulator in Heterogeneous Media for PET Resolution Modelling
Positron range (PR) degrades spatial resolution in positron emission tomography (PET), with its effect being radionuclide- and medium-dependent. Current accurate PR simulators are computationally intensive and cannot be used in clinical time frames. This work presents the Hybrid Monte Carlo (HMC) PR simulator, a GPU-accelerated condensed-history code in CUDA Fortran for 3D annihilation imaging in heterogeneous voxelised geometries derived from CT images and -maps. Pre-computed look-up interaction tables (LUTs) covering 24 reference-tissue materials and support for arbitrary emitters up to 3.55 MeV end-point energies (68Ga, 82Rb, 124I, etc.) allow both GPU and CPU implementations. Maximum speeds reach (Intel i9-14900KF) and (NVIDIA RTX 5080) histories/s, surpassing prior CPU-only PenEasy 2024 by up to 4 orders of magnitude. A fixed step of 0.5 mm was chosen for LUT generation with a uniform variation each HMC step that allowed reducing aliasing effects. These values are consistent with our previous cross-code benchmark for the isotopes studied. Close agreement with PenEasy 2024 is demonstrated: point-source FWHM and FWTM residuals using 18F, 68Ga, 124I and 82Rb are below 0.3 mm at histories, and voxelwise , and PSNR dB are achieved simulating 82Rb uptake from a human-scale [18F]FDG myocardium acquisition, while decreasing the simulation time from almost 9 h to roughly 1 s using HMC GPU. The resulting annihilation maps enable PET resolution modelling and patient-specific PR correction within clinically practical time frames.- 4 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (13) , 6706
Open AccessCondensed-History GPU Positron Range Simulator in Heterogeneous Media for PET Resolution Modelling
Positron range (PR) degrades spatial resolution in positron emission tomography (PET), with its effect being radionuclide- and medium-dependent. Current accurate PR simulators are computationally intensive and cannot be used in clinical time frames. This work presents the Hybrid Monte Carlo (HMC) PR simulator, a GPU-accelerated condensed-history code in CUDA Fortran for 3D annihilation imaging in heterogeneous voxelised geometries derived from CT images and -maps. Pre-computed look-up interaction tables (LUTs) covering 24 reference-tissue materials and support for arbitrary emitters up to 3.55 MeV end-point energies (68Ga, 82Rb, 124I, etc.) allow both GPU and CPU implementations. Maximum speeds reach (Intel i9-14900KF) and (NVIDIA RTX 5080) histories/s, surpassing prior CPU-only PenEasy 2024 by up to 4 orders of magnitude. A fixed step of 0.5 mm was chosen for LUT generation with a uniform variation each HMC step that allowed reducing aliasing effects. These values are consistent with our previous cross-code benchmark for the isotopes studied. Close agreement with PenEasy 2024 is demonstrated: point-source FWHM and FWTM residuals using 18F, 68Ga, 124I and 82Rb are below 0.3 mm at histories, and voxelwise , and PSNR dB are achieved simulating 82Rb uptake from a human-scale [18F]FDG myocardium acquisition, while decreasing the simulation time from almost 9 h to roughly 1 s using HMC GPU. The resulting annihilation maps enable PET resolution modelling and patient-specific PR correction within clinically practical time frames. - Open Access
- 6 May 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 235, 112686
Efficient Monte Carlo modeling for Gamma Knife Perfexion
- 6 May 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 235, 112686
Open AccessEfficient Monte Carlo modeling for Gamma Knife Perfexion
- 24 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 037001
Kali MC: an open-source toolkit for intraoperative electron radiation therapy treatment planning
Intraoperative electron radiation therapy (IOERT) is commonly delivered without intraoperative imaging, limiting patient-specific planning and requiring fast, reliable treatment calculations in the operating room. As a result, monitor unit (MU) calculations are often performed using spreadsheets and static look-up tables derived from measurements in water. We present Kali MC, an open source, Python-based software developed to streamline IOERT absorbed dose visualization, MU calculation and report generation for treatments delivered with the Liac HWL mobile accelerator. The software provides a graphical interface to visualize precomputed Monte Carlo absorbed dose distributions in water and performs MU calculations using experimentally determined output factors. Optional atmospheric pressure correction and predefined rescaling factors are supported to improve consistency of dose delivery and target coverage with the prescription isodose. Kali MC also generates customizable PDF treatment reports and exports DICOM RT Plan objects to facilitate integration with record-and-verify systems. By integrating validated dosimetric data, correction methods, and 3D dose visualization into a transparent platform, Kali MC supports efficient intraoperative decision-making; however, its use should be locally commissioned and evaluated according to institution-specific procedures and equipment characteristics.
- 24 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 037001
Kali MC: an open-source toolkit for intraoperative electron radiation therapy treatment planning
Intraoperative electron radiation therapy (IOERT) is commonly delivered without intraoperative imaging, limiting patient-specific planning and requiring fast, reliable treatment calculations in the operating room. As a result, monitor unit (MU) calculations are often performed using spreadsheets and static look-up tables derived from measurements in water. We present Kali MC, an open source, Python-based software developed to streamline IOERT absorbed dose visualization, MU calculation and report generation for treatments delivered with the Liac HWL mobile accelerator. The software provides a graphical interface to visualize precomputed Monte Carlo absorbed dose distributions in water and performs MU calculations using experimentally determined output factors. Optional atmospheric pressure correction and predefined rescaling factors are supported to improve consistency of dose delivery and target coverage with the prescription isodose. Kali MC also generates customizable PDF treatment reports and exports DICOM RT Plan objects to facilitate integration with record-and-verify systems. By integrating validated dosimetric data, correction methods, and 3D dose visualization into a transparent platform, Kali MC supports efficient intraoperative decision-making; however, its use should be locally commissioned and evaluated according to institution-specific procedures and equipment characteristics.
- Open Access
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
MLTiming: Pairwise-Constrained Learning for Improving Timing Resolution in TOF-PET
Accurate timing characterization of detected radiation events in Positron Emission Tomography (PET) provides Time-of-flight (TOF) information for detected coincidences, which improves the signal-to-noise ratio of the reconstructed images. In this work, we propose a method, called MLTiming, to train machine learning (ML) models to assign accurate timestamps to events measured in radiation detectors training using just the signals detected by the individual single-channel detectors, without the need of resorting to other detector signals nor simulations. We performed a proof-of-concept study using three different neural network (NN) architectures, including the recently proposed Kolmogorov-Arnold network (KAN), trained with event pairs constructed with the measured signal and a delayed version of it. The delay is used as a label in the training process. The proposed trained model was evaluated with coincidence data acquired with a 22Na point source using a pair of LaBr3(Ce) crystals in the shape of truncated cones coupled to fast photomultiplier tubes (PMTs). The detected γ-ray pulses were sampled at 5 Gsamples/s. A 3% improvement in Coincidence Time Resolution (CTR) over an ultra optimized genetic algorithm–enhanced digital CFD (D-CFD) method (246±3 ps to 238±1 ps) was achieved. The possibility of training ML models for each individual detector using only the information contained in their own detected events may facilitate the use of ML models for large and medium-sized scanners, as well as other research areas. MLTiming is available at https://github.com/wjosefw/MLTiming.git.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Open AccessMLTiming: Pairwise-Constrained Learning for Improving Timing Resolution in TOF-PET
Accurate timing characterization of detected radiation events in Positron Emission Tomography (PET) provides Time-of-flight (TOF) information for detected coincidences, which improves the signal-to-noise ratio of the reconstructed images. In this work, we propose a method, called MLTiming, to train machine learning (ML) models to assign accurate timestamps to events measured in radiation detectors training using just the signals detected by the individual single-channel detectors, without the need of resorting to other detector signals nor simulations. We performed a proof-of-concept study using three different neural network (NN) architectures, including the recently proposed Kolmogorov-Arnold network (KAN), trained with event pairs constructed with the measured signal and a delayed version of it. The delay is used as a label in the training process. The proposed trained model was evaluated with coincidence data acquired with a 22Na point source using a pair of LaBr3(Ce) crystals in the shape of truncated cones coupled to fast photomultiplier tubes (PMTs). The detected γ-ray pulses were sampled at 5 Gsamples/s. A 3% improvement in Coincidence Time Resolution (CTR) over an ultra optimized genetic algorithm–enhanced digital CFD (D-CFD) method (246±3 ps to 238±1 ps) was achieved. The possibility of training ML models for each individual detector using only the information contained in their own detected events may facilitate the use of ML models for large and medium-sized scanners, as well as other research areas. MLTiming is available at https://github.com/wjosefw/MLTiming.git.
- Open Access
- 11 February 2026
- Published by Elsevier in NeuroImage
- Vol. 328, 121797
Stress-induced takotsubo syndrome: dynamic changes in regional cerebral metabolism revealed by quantitative PET imaging
- 11 February 2026
- Published by Elsevier in NeuroImage
- Vol. 328, 121797
Open AccessStress-induced takotsubo syndrome: dynamic changes in regional cerebral metabolism revealed by quantitative PET imaging
- Open Access
- 26 January 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (1)
Search for β -delayed fission of Au g , m 178 and an updated systematics in the region of neutron-deficient nuclei
A search for a β -delayed fission ( β DF ) decay branch of isomerically pure samples of Au g 178 and Au m 178 was performed at the ISOLDE-CERN facility. Two complementary detection systems capable of registering α decays and fission fragments, the ISOLDE Decay Station and the ASET (Alpha SETup), were used. Despite very high statistics of produced Au 178 nuclei, no fission fragments were detected. Upper limits of β DF probabilities of P β DF ( Au g 178 ) < 1.11 ( 2 ) × 10 − 8 and P β DF ( Au m 178 ) < 9.7 ( 2 ) × 10 − 9 were determined. Corresponding lower limits of β DF partial half-lives were deduced as well, and the results are discussed in the context of experimental systematics of β DF in the neutron-deficient region of the nuclear chart.
- 26 January 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 113 (1)
Open AccessSearch for β -delayed fission of Au g , m 178 and an updated systematics in the region of neutron-deficient nuclei
A search for a β -delayed fission ( β DF ) decay branch of isomerically pure samples of Au g 178 and Au m 178 was performed at the ISOLDE-CERN facility. Two complementary detection systems capable of registering α decays and fission fragments, the ISOLDE Decay Station and the ASET (Alpha SETup), were used. Despite very high statistics of produced Au 178 nuclei, no fission fragments were detected. Upper limits of β DF probabilities of P β DF ( Au g 178 ) < 1.11 ( 2 ) × 10 − 8 and P β DF ( Au m 178 ) < 9.7 ( 2 ) × 10 − 9 were determined. Corresponding lower limits of β DF partial half-lives were deduced as well, and the results are discussed in the context of experimental systematics of β DF in the neutron-deficient region of the nuclear chart.
- Open Access
Electron-induced single-pion production to constrain the neutron structure in $^{40}$Ar. A proof of concept
We study electron-induced single-pion production as a way to constrain the neutron structure of $^{40}$Ar, information that is necessary for neutrino experiments using argon detectors. The proposed experimental signal consists in detecting in coincidence the scattered electron, a proton and a $π^-$. We performed simulations compatible with the experimental conditions of the MAMI (University of Mainz) and CLAS (Jefferson Lab) facilities. We have computed cross sections and evaluated the main backgrounds. MAMI is a three-spectrometer system with extremely good energy resolution and small acceptances. We found that, by choosing specific values of the final particle's momenta, the shell structure can be well resolved, with negligible background contributions. CLAS is a large solid angle detector with poorer energy resolution. In both cases, the background can be kept under control by performing cuts in missing energy and missing momentum; however, in CLAS, the shell structure cannot be resolved due to the energy resolution. We conclude that MAMI is particularly appropriate for the proposed experiment, whereas CLAS is better suited for other studies.Open AccessElectron-induced single-pion production to constrain the neutron structure in $^{40}$Ar. A proof of concept
We study electron-induced single-pion production as a way to constrain the neutron structure of $^{40}$Ar, information that is necessary for neutrino experiments using argon detectors. The proposed experimental signal consists in detecting in coincidence the scattered electron, a proton and a $π^-$. We performed simulations compatible with the experimental conditions of the MAMI (University of Mainz) and CLAS (Jefferson Lab) facilities. We have computed cross sections and evaluated the main backgrounds. MAMI is a three-spectrometer system with extremely good energy resolution and small acceptances. We found that, by choosing specific values of the final particle's momenta, the shell structure can be well resolved, with negligible background contributions. CLAS is a large solid angle detector with poorer energy resolution. In both cases, the background can be kept under control by performing cuts in missing energy and missing momentum; however, in CLAS, the shell structure cannot be resolved due to the energy resolution. We conclude that MAMI is particularly appropriate for the proposed experiment, whereas CLAS is better suited for other studies. - 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 753-763
Impact of DOI Capability on Detector Performance: A Comparative Study of DOI and Non-DOI Detectors for High-Resolution and Sensitivity Organ-Specific PET Inserts
High-sensitivity organ-specific PET inserts employing long scintillation crystals in combination with small ring diameters require depth-of-interaction (DOI) encoding to ensure uniform spatial resolution across the field of view. In this study, we have developed high-resolution, DOI-capable detectors based on the Hamamatsu C13500 TOF-PET modules, using 1.6W1.6 mm2 LSO crystals coupled to 4W4 mm2 SiPMs. Detector configurations were designed either for a brain PET/MR insert (26 mm long crystals with a top light guide (TLG) for DOI encoding via light spread) or for a breast PET/MR insert (15 mm long with a TLG; 15 mm long with a stacked dual-layer configuration). Corresponding reference configurations without DOI capability were included to assess the impact of DOI implementation on detector performance. The 26 mm long brain detector configuration with TLG achieved an energy resolution of 12.1% and a coincidence time resolution (CTR) of 684 ps, with a degradation of 148 ps compared to the non-DOI variant. A newly developed DOI parameter calculation method improved DOI resolution from 9.1 1 1.7 mm to 7.1 1 1.8 mm. The 15 mm long single layer breast detector configuration with TLG yielded an energy resolution of 10.8%, a CTR of 460 ps, and a DOI resolution of 6.3 1 1.8 mm. The 15 mm dual layer detector configuration provided comparable performance (11.5% energy resolution, 605 ps CTR) while eliminating the need for DOI calibration. For both the 15 and 26 mm single layer crystal block configurations, introducing a TLG preserved crystal identification and energy resolution. Overall, the DOI-capable designs demonstrated only minor performance trade-offs, supporting the feasibility of both approaches for integration into organ-specific PET/MR inserts.
- 27 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 753-763
Impact of DOI Capability on Detector Performance: A Comparative Study of DOI and Non-DOI Detectors for High-Resolution and Sensitivity Organ-Specific PET Inserts
High-sensitivity organ-specific PET inserts employing long scintillation crystals in combination with small ring diameters require depth-of-interaction (DOI) encoding to ensure uniform spatial resolution across the field of view. In this study, we have developed high-resolution, DOI-capable detectors based on the Hamamatsu C13500 TOF-PET modules, using 1.6W1.6 mm2 LSO crystals coupled to 4W4 mm2 SiPMs. Detector configurations were designed either for a brain PET/MR insert (26 mm long crystals with a top light guide (TLG) for DOI encoding via light spread) or for a breast PET/MR insert (15 mm long with a TLG; 15 mm long with a stacked dual-layer configuration). Corresponding reference configurations without DOI capability were included to assess the impact of DOI implementation on detector performance. The 26 mm long brain detector configuration with TLG achieved an energy resolution of 12.1% and a coincidence time resolution (CTR) of 684 ps, with a degradation of 148 ps compared to the non-DOI variant. A newly developed DOI parameter calculation method improved DOI resolution from 9.1 1 1.7 mm to 7.1 1 1.8 mm. The 15 mm long single layer breast detector configuration with TLG yielded an energy resolution of 10.8%, a CTR of 460 ps, and a DOI resolution of 6.3 1 1.8 mm. The 15 mm dual layer detector configuration provided comparable performance (11.5% energy resolution, 605 ps CTR) while eliminating the need for DOI calibration. For both the 15 and 26 mm single layer crystal block configurations, introducing a TLG preserved crystal identification and energy resolution. Overall, the DOI-capable designs demonstrated only minor performance trade-offs, supporting the feasibility of both approaches for integration into organ-specific PET/MR inserts.