Mark George Bason
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mark George Bason has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Charles S. Adams
Durham University
7 shared publications - Nicola Malossi
School of Science and Technology, Physics Division, University of Camerino, I-62032 Camerino (MC), Italy
7 shared publications - Oliver Morsch
CNR-INO
7 shared publications - Kevin J. Weatherill
Department of Physics, Durham University, Durham, U.K.
5 shared publications - Robert Heck
Aarhus Universitet Institut for Fysik og Astronomi, Ny Munkegade 120, Aarhus, 8000, DENMARK
4 shared publications Romain Müller
Aarhus Universitet, Aarhus, Denmark
4 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 8 (3)
A high-flux source of cold strontium with a loading rate of 4×1010 atoms/s for open release
We present a high-flux source of cold strontium atoms based on a two-dimensional magneto-optical trap (2D MOT) and a Zeeman slower. We use the source to load a 3D MOT in a separate science chamber, observing a loading rate of 4×1010 atoms/s—to our knowledge, the highest reported loading flux for strontium. To characterize the vacuum pressure in the science chamber, we load the atoms into a magnetic trap and measure a lifetime of between 8 and 24 s, depending on the oven temperature. Finally, we characterize the atom flux and velocity distributions from the oven and from the 2D MOT source, finding reasonable agreement with models in the free molecular flow regime. Our results show that it is possible to readily produce a cold strontium flux at comparable levels to those of alkali species, at oven temperatures compatible with long-term operation, and at vacuum pressures suitable for state-of-the-art quantum experiments. We make our design available at no cost to benefit researchers in the quantum community.
- 10 July 2026
- Published by American Vacuum Society in AVS Quantum Science
- Vol. 8 (3)
Open AccessA high-flux source of cold strontium with a loading rate of 4×1010 atoms/s for open release
We present a high-flux source of cold strontium atoms based on a two-dimensional magneto-optical trap (2D MOT) and a Zeeman slower. We use the source to load a 3D MOT in a separate science chamber, observing a loading rate of 4×1010 atoms/s—to our knowledge, the highest reported loading flux for strontium. To characterize the vacuum pressure in the science chamber, we load the atoms into a magnetic trap and measure a lifetime of between 8 and 24 s, depending on the oven temperature. Finally, we characterize the atom flux and velocity distributions from the oven and from the 2D MOT source, finding reasonable agreement with models in the free molecular flow regime. Our results show that it is possible to readily produce a cold strontium flux at comparable levels to those of alkali species, at oven temperatures compatible with long-term operation, and at vacuum pressures suitable for state-of-the-art quantum experiments. We make our design available at no cost to benefit researchers in the quantum community.
- Open Access
- 19 June 2024
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 9 (3) , 035045
A modular optically pumped magnetometer system
To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.
- 19 June 2024
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 9 (3) , 035045
Open AccessA modular optically pumped magnetometer system
To address the demands in healthcare and industrial settings for spatially resolved magnetic imaging, we present a modular optically pumped magnetometer (OPM) system comprising a multi-sensor array of highly sensitive quantum magnetometers. This system is designed and built to facilitate fast prototyping and testing of new measurement schemes by enabling quick reconfiguration of the self-contained laser and sensor modules as well as allowing for the construction of various array layouts with a shared light source. The modularity of this system facilitates the development of methods for managing high-density arrays for magnetic imaging. The magnetometer sensitivity and bandwidth are first characterised in both individual channel and differential gradiometer configurations before testing in a real-world magnetoencephalography environment by measuring alpha rhythms from the brain of a human participant. We demonstrate the OPM system in a first-order axial gradiometer configuration with a magnetic field gradient sensitivity of 10 fT / cm / Hz at a baseline of 4.5 cm. Single-channel operation achieved a sensitivity of 65 fT / Hz . Bandwidths exceeding 200 Hz were achieved for two independent modules. The system’s increased temporal resolution allows for the measurement of spinal cord signals, which we demonstrate by using phantom signal trials and comparing with an existing commercial sensor.
- Open Access
- 7 April 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 533, 231312
Non-invasive current density imaging of lithium-ion batteries
- 7 April 2022
- Published by Elsevier in Journal of Power Sources
- Vol. 533, 231312
Open AccessNon-invasive current density imaging of lithium-ion batteries
- Open Access
Improved spatio-temporal measurements of visually-evoked fields using optically-pumped magnetometers
Recent developments in performance and practicality of optically pumped magnetometers have enabled new capabilities in non-invasive brain function mapping through magnetoencephalography. In particular the lack of need of cryogenic operating conditions allows for more flexible placement of the sensor heads closer to the brain surface, leading to improved spatial measurement resolution and increased source localisation capabilities. Through the recording of visually evoked brain fields (VEF), we demonstrate that the closer sensor proximity can be further exploited to improve the temporal resolution. We use optically pumped magnetometers (OPMs), and for reference superconducting quantum interference devices (SQUIDs), to measure brain responses to standard flash and pattern reversal stimuli. We find highly reproducible signals with consistency across multiple healthy participants, stimulus paradigms and sensor modalities. The temporal resolution advantage of OPMs is manifest in a fourfold improvement of the ratio of magnetic signal peak height to temporal width, compared to SQUIDs. The resulting capability of improved spatio-temporal signal tracing is illustrated by simultaneous vector recordings of VEFs in the primary (V1) and associative (V2) visual cortex, where a time lag on the order of 10-20 ms is consistently found. This paves the way for further studies of spatio-temporal neurophysiological signal tracking in visual stimulus processing and other brain responses with potentially far-reaching consequences for time-critical mapping of functionality in the healthy and pathological brains.
Open AccessImproved spatio-temporal measurements of visually-evoked fields using optically-pumped magnetometers
Recent developments in performance and practicality of optically pumped magnetometers have enabled new capabilities in non-invasive brain function mapping through magnetoencephalography. In particular the lack of need of cryogenic operating conditions allows for more flexible placement of the sensor heads closer to the brain surface, leading to improved spatial measurement resolution and increased source localisation capabilities. Through the recording of visually evoked brain fields (VEF), we demonstrate that the closer sensor proximity can be further exploited to improve the temporal resolution. We use optically pumped magnetometers (OPMs), and for reference superconducting quantum interference devices (SQUIDs), to measure brain responses to standard flash and pattern reversal stimuli. We find highly reproducible signals with consistency across multiple healthy participants, stimulus paradigms and sensor modalities. The temporal resolution advantage of OPMs is manifest in a fourfold improvement of the ratio of magnetic signal peak height to temporal width, compared to SQUIDs. The resulting capability of improved spatio-temporal signal tracing is illustrated by simultaneous vector recordings of VEFs in the primary (V1) and associative (V2) visual cortex, where a time lag on the order of 10-20 ms is consistently found. This paves the way for further studies of spatio-temporal neurophysiological signal tracking in visual stimulus processing and other brain responses with potentially far-reaching consequences for time-critical mapping of functionality in the healthy and pathological brains.
- 23 October 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (17) , 177204
Tailoring Magnetic Fields in Inaccessible Regions
Controlling magnetism, essential for a wide range of technologies, is impaired by the impossibility of generating a maximum of magnetic field in free space. Here, we propose a strategy based on negative permeability to overcome this stringent limitation. We experimentally demonstrate that an active magnetic metamaterial can emulate the field of a straight current wire at a distance. Our strategy leads to an unprecedented focusing of magnetic fields in empty space and enables the remote cancellation of magnetic sources, opening an avenue for manipulating magnetic fields in inaccessible regions.
- 23 October 2020
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 125 (17) , 177204
Tailoring Magnetic Fields in Inaccessible Regions
Controlling magnetism, essential for a wide range of technologies, is impaired by the impossibility of generating a maximum of magnetic field in free space. Here, we propose a strategy based on negative permeability to overcome this stringent limitation. We experimentally demonstrate that an active magnetic metamaterial can emulate the field of a straight current wire at a distance. Our strategy leads to an unprecedented focusing of magnetic fields in empty space and enables the remote cancellation of magnetic sources, opening an avenue for manipulating magnetic fields in inaccessible regions.
- 19 March 2019
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 52 (7) , 075003
Spatially-selective in situ magnetometry of ultracold atomic clouds
We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the size of the analysed region for the vectorial magnetometer and provide a lower bound for the measurement precision of magnetic field gradients for the Larmor magnetometer. Finally, we give an outlook on how dynamic trapping potentials combined with selective probing can be used to realise enhanced quantum simulations in quantum gas microscopes.
- 19 March 2019
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 52 (7) , 075003
Spatially-selective in situ magnetometry of ultracold atomic clouds
We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the size of the analysed region for the vectorial magnetometer and provide a lower bound for the measurement precision of magnetic field gradients for the Larmor magnetometer. Finally, we give an outlook on how dynamic trapping potentials combined with selective probing can be used to realise enhanced quantum simulations in quantum gas microscopes.
- Open Access
- 9 November 2018
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 115 (48) , E11231-E11237
Remote optimization of an ultracold atoms experiment by experts and citizen scientists
Significance: The emerging field of gamified citizen science continually probes the fault line between human and artificial intelligence. A better understanding of citizen scientists’ search strategies may lead to cognitive insights and provide inspiration for algorithmic improvements. Our project remotely engages both the general public and experts in the real-time optimization of an experimental laboratory setting. In this citizen science project the game and data acquisition are designed as a social science experiment aimed at extracting the collective search behavior of the players. A further understanding of these human skills will be a crucial challenge in the coming years, as hybrid intelligence solutions are pursued in corporate and research environments.
- 9 November 2018
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 115 (48) , E11231-E11237
Open AccessRemote optimization of an ultracold atoms experiment by experts and citizen scientists
Significance: The emerging field of gamified citizen science continually probes the fault line between human and artificial intelligence. A better understanding of citizen scientists’ search strategies may lead to cognitive insights and provide inspiration for algorithmic improvements. Our project remotely engages both the general public and experts in the real-time optimization of an experimental laboratory setting. In this citizen science project the game and data acquisition are designed as a social science experiment aimed at extracting the collective search behavior of the players. A further understanding of these human skills will be a crucial challenge in the coming years, as hybrid intelligence solutions are pursued in corporate and research environments.
- 6 August 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (17) , 175301
Measurement-enhanced determination of BEC phase transitions
We demonstrate how dispersive atom number measurements during evaporative cooling can be used for enhanced determination of the parameter dependence of the transition to a Bose–Einstein condensate (BEC). In this way shot-to-shot fluctuations in initial conditions are detected and the information extracted per experimental realization is increased. We furthermore calibrate in situ images from dispersive probing of a BEC with corresponding absorption images in time-of-flight. This allows for the determination of the transition point in a single experimental realization by applying multiple dispersive measurements. Finally, we explore the continuous probing of several consecutive phase transition crossings using the periodic addition of a focused ‘dimple’ potential.
- 6 August 2018
- Published by IOP Publishing in Journal of Physics B: Atomic, Molecular and Optical Physics
- Vol. 51 (17) , 175301
Measurement-enhanced determination of BEC phase transitions
We demonstrate how dispersive atom number measurements during evaporative cooling can be used for enhanced determination of the parameter dependence of the transition to a Bose–Einstein condensate (BEC). In this way shot-to-shot fluctuations in initial conditions are detected and the information extracted per experimental realization is increased. We furthermore calibrate in situ images from dispersive probing of a BEC with corresponding absorption images in time-of-flight. This allows for the determination of the transition point in a single experimental realization by applying multiple dispersive measurements. Finally, we explore the continuous probing of several consecutive phase transition crossings using the periodic addition of a focused ‘dimple’ potential.
- 16 April 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (4) , 043416
Dispersive detection of radio-frequency-dressed states
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
- 16 April 2018
- Published by American Physical Society (APS) in Physical Review A
- Vol. 97 (4) , 043416
Dispersive detection of radio-frequency-dressed states
We introduce a method to dispersively detect alkali-metal atoms in radio-frequency-dressed states. In particular, we use dressed detection to measure populations and population differences of atoms prepared in their clock states. Linear birefringence of the atomic medium enables atom number detection via polarization homodyning, a form of common path interferometry. In order to achieve low technical noise levels, we perform optical sideband detection after adiabatic transformation of bare states into dressed states. The balanced homodyne signal then oscillates independently of field fluctuations at twice the dressing frequency, thus allowing for robust, phase-locked detection that circumvents low-frequency noise. Using probe pulses of two optical frequencies, we can detect both clock states simultaneously and obtain population difference as well as the total atom number. The scheme also allows for difference measurements by direct subtraction of the homodyne signals at the balanced detector, which should technically enable quantum noise limited measurements with prospects for the preparation of spin squeezed states. The method extends to other Zeeman sublevels and can be employed in a range of atomic clock schemes, atom interferometers, and other experiments using dressed atoms.
- 1 July 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (7) , 073106
A simple laser locking system based on a field-programmable gate array
Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The locking system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.
- 1 July 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (7) , 073106
A simple laser locking system based on a field-programmable gate array
Frequency stabilization of laser light is crucial in both scientific and industrial applications. Technological developments now allow analog laser stabilization systems to be replaced with digital electronics such as field-programmable gate arrays, which have recently been utilized to develop such locking systems. We have developed a frequency stabilization system based on a field-programmable gate array, with emphasis on hardware simplicity, which offers a user-friendly alternative to commercial and previous home-built solutions. Frequency modulation, lock-in detection, and a proportional-integral-derivative controller are programmed on the field-programmable gate array and only minimal additional components are required to frequency stabilize a laser. The locking system is administered from a host-computer which provides comprehensive, long-distance control through a versatile interface. Various measurements were performed to characterize the system. The linewidth of the locked laser was measured to be 0.7 ± 0.1 MHz with a settling time of 10 ms. The system can thus fully match laser systems currently in use for atom trapping and cooling applications.