MSMattia Di Segni

Mattia Di Segni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mattia Di Segni has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Thyroid Nodule Characterization: Which Thyroid Imaging Reporting and Data System (TIRADS) Is More Accurate? A Comparison Between Radiologists with Different Experiences and Artificial Intelligence Software

    by Emanuele David, Lorenzo Aliotta, Fabrizio Frezza, Marianna Riccio, Alessandro Cannavale, Patrizia Pacini, Chiara Di Bella, Vincenzo Dolcetti, Elena Seri, Luca Giuliani, et al.

    Purpose: This study aimed to compare: the performance of K-TIRADS, EU-TIRADS and ACR TIRADS when used by observers with different levels of experience compared with the gold standard of cytology, and to evaluate the diagnostic performance of CAD (computer-aided design) compared with TI-RADS systems. Methods and Materials: In total, 323 thyroid nodules were evaluated in patients who were candidates for needle aspiration. Three observers with different levels of experience evaluated the diagnostic accuracy of three risk stratification systems (ACR TI-RADS, EU-TIRADS and K-TIRADS) and CAD software (S-Detect, made by Samsung) in characterizing the nodules. The results were compared with cytology examination. All nodules were characterized in terms of shape, margins, composition, calcifications, size, echogenicity and microcalcifications, and by stratifying individual nodules by using the three TIRADS systems; then S-detect software was applied and the data were compared with each other and with the gold standard. Results: Through cytology, 308 benign and 33 malignant nodules were identified. ACR-TIRADS showed a sensitivity of 100%, a specificity of 86%, a positive predictive value of 43% and a negative predictive value of 100%. EU-TIRADS showed a sensitivity of 100%, a specificity of 79%, a positive predictive value of 33% and a negative predictive value of 100%. K-TIRADS showed a sensitivity of 100%, a specificity of 89%, a positive predictive value of 50% and a negative predictive value of 100%. S-Detect combined with EU-TIRADS showed a high agreement (>95%) with the gold standard. Conclusions: K-TIRADS’s positive predictive power was slightly better than the other TIRADS, suggesting greater accuracy in correctly diagnosing positive cases. S-DETECT combined with EU-TIRADS has similar results to S-Detect with ACR- and K-TIRADS in terms of sensitivity, specificity and negative predictive power. However, it has a slightly better positive predictive power, suggesting greater accuracy in correctly diagnosing positive cases than the ACR- and K-TIRADS classification systems. In general, S-Detect cannot yet be considered a substitute for the human observer but only as an important support for human evaluation and an excellent and fast help to provide a comprehensive and complete report. Clinical Relevance/Application: S-Detect is a valuable tool for characterizing thyroid nodules when integrated with radiologist evaluation. It is also an important support tool for less experienced observers. Particularly interesting is the approach of use in integrated combination of the K-TIRADS by the human observer with S-Detect using EU-TIRADS, which could increase the overall diagnostic efficiency of the systems.


  • Open Access

    Elevated Native T1 Values in the Remote Myocardium Supplied by Obstructive Non-Infarct Related Coronary Arteries in Post-STEMI Cardiac Magnetic Resonance

    by Yafim Brodov, Shlomi Matetzky, Eli Konen, Mattia Di Segni, Anan Younis, Ayas Massalha, Anat Berkovitch, Arkadi Beytelman, Fernando Chernomordik, Orly Goitein

    Introduction: Native T1 mapping values are elevated in acutely injured myocardium. We sought to study whether native T1 values, in the non-infarct related myocardial territories, might differ when supplied by obstructive or nonobstructive coronary arteries. Methods: Consecutive patients (N = 60, mean age 59 years) with the first STEMI following primary percutaneous coronary intervention, underwent cardiac magnetic resonance within 5 ± 2 days. A retrospective review of coronary angiography reports classified coronary arteries as infarct-related coronary artery (IRA) and non-IRA. Obstructive coronary artery disease (CAD) was defined as stenosis ≥50%. Native T1 values were presented using a 16-segment AHA model according to the three main coronary territories: left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA). Results: The cutoff native T1 value for predicting obstructive non-IRA LAD was 1,309 msec with a sensitivity and specificity of 67% and 82%, respectively (AUC 0.76, 95% CI: 0.57–0.95, p = 0.04). The cutoff native T1 value for predicting obstructive non-IRA RCA was 1,302 msec with a sensitivity and specificity of 83% and 55%, respectively (AUC 0.7, 95% CI: 0.52–0.87, p = 0.05). Logistic regression model adjusted for age and infarct size demonstrated that native T1 was an independent predictor for the obstructive non-IRA LAD (OR 4.65; 1.32–26.96, p = 0.05) and RCA (OR 3.70; 1.44–16.35, p = 0.03). Conclusion: Elevated native T1 values are independent predictors of obstructive non-IRA in STEMI patients. These results suggest the presence of concomitant remote myocardial impairment in the non-infarct territories with obstructive CAD.


  • Preoperative evaluation of tumor depth of invasion in oral squamous cell carcinoma with intraoral ultrasonography: a retrospective study

    by Federica Rocchetti, Gianluca Tenore, Alessandra Montori, Andrea Cassoni, Vito Cantisani, Mattia Di Segni, Cira Rosaria Tiziana Di Gioia, Raffaella Carletti, Valentino Valentini, Antonella Polimeni, et al.


  • Open Access

    Correlation of body composition by computerized tomography and metabolic parameters with survival of nivolumab-treated lung cancer patients

    by Valentina Magri, Teodor Gottfried, Mattia Di Segni, Damien Urban, Michael Peled, Sameh Daher, Ronen Stoff, Jair Bar, Amir Onn

    Purpose: Weight loss is a well-recognized prognostic parameter for survival of lung cancer patients. Computerized-tomography (CT)-based analysis of body composition and blood-based metabolic evaluation are promising prognostic tools. We aimed to assess the correlation between albumin, body mass index (BMI), skeletal muscle mass index (SMI), fat-free mass index (FFMI), fat mass index (FMI) and weight change, as well as their correlation with survival of lung cancer patients on nivolumab treatment. Methods: Data were retrospectively collected. Weight was measured at a diagnosis of stage 4 disease and before start of nivolumab. Albumin levels were measured before starting nivolumab. BMI, SMI, FFMI, and FMI were evaluated from CT scans performed at start of nivolumab. Overall survival (OS) was from starting of nivolumab to death or censured at last follow-up. Statistical analysis was done to identify correlation between the various factors and between those factors and survival. Results: Forty-six patients with advanced non-small cell lung cancer (NSCLC) were included. Median follow-up was 22 months. Pathology was Adenocarcinoma/Squamous/non-other specified in 25/15/6 respectively. All patients received nivolumab as an advanced-line treatment for stage IV NSCLC. We observed a significant correlation of weight loss (P=0.01, HR=2.85) and albumin (P=0.043, HR=0.34) with OS in multivariate analysis. A significant correlation was found between BMI to SMI, FFMI, FMI, and weight change. Conclusion: Weight loss and low albumin levels are significant negative prognostic factors for NSCLC patients on immunotherapy. CT-based parameters of body composition remain to be proven as more reliable than standard clinical parameters.


  • Automated classification of focal breast lesions according to S-detect: validation and role as a clinical and teaching tool

    by Mattia Di Segni, Valeria de Soccio, Vito Cantisani, Giacomo Bonito, Antonello Rubini, Gabriele Di Segni, Sveva Lamorte, Valentina Magri, Corrado De Vito, Giuseppe Migliara, et al.

    To assess the diagnostic performance and the potential as a teaching tool of S-detect in the assessment of focal breast lesions.