Huaiyu Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Huaiyu Wu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Fajin Dong
The Second Clinical Medical College, Jinan University, Shenzhen, China
5 shared publications - Jinfeng Xu
Department of Ultrasound Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology) Shenzhen Guangdong China
3 shared publications Jinfeng Xu
Department of Ultrasound Second Clinical College of Jinan University, Shenzhen People's Hospital, First Affiliated Hospital of Southern University of Science and Technology, Shenzhen Medical Ultrasound Engineering Center Shenzhen People's Republic of China
2 shared publicationsLei Zhang
Department of Ultrasound, First Affiliated Hospital of the Southern University of Science and Technology, Second Clinical College of Jinan University, Shenzhen Medical Ultrasound Engineering Center, Shenzhen People's Hospital, Shenzhen, China
2 shared publicationsSiyuan Shi
Research and Development Department, Illuminate, LLC, Shenzhen, Guangdong 518000, China
2 shared publicationsWeiyu Liang
Department of Ultrasound Second Clinical College of Jinan University, Shenzhen People's Hospital, First Affiliated Hospital of Southern University of Science and Technology, Shenzhen Medical Ultrasound Engineering Center Shenzhen People's Republic of China
2 shared publications
Latest Publications
- 21 January 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 245, 108039
Sonography-based multimodal information platform for identifying the surgical pathology of ductal carcinoma in situ
- 21 January 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 245, 108039
Sonography-based multimodal information platform for identifying the surgical pathology of ductal carcinoma in situ
- 25 September 2023
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 51 (9) , 1492-1501
Appendicitis in pregnant women: A systematic review and meta‐analysis of the diagnostic performance of ultrasonography
Objectives: The accuracy of ultrasound in the detection of appendicitis in pregnant women was examined in a meta‐analysis.Methods: Pregnant women with suspected acute appendicitis were evaluated using ultrasound in a systematic search of PubMed, EMBASE, and Cochrane Library databases from January 1, 2011 to August 10, 2023. The sensitivity and specificity values and diagnostic odds ratios were obtained using the pooled data.Results: A total of 239 patients were studied in four relevant investigations. Ultrasonography has a sensitivity of 56% and a specificity of 88% for the diagnosis of acute appendicitis, with an area under the receiver operating characteristic curve of 0.66%. Ultrasonography had a positive likelihood ratio of 4.65 (95% confidence interval, 1.42–15.23) and a negative likelihood ratio of 0.50 (95% confidence interval, 0.41–0.62). There was no evidence of publication bias (p = 0.93).Conclusions: Ultrasound has moderate sensitivity for identifying appendicitis in pregnant women and may be utilized as an alternative diagnostic method.
- 25 September 2023
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 51 (9) , 1492-1501
Appendicitis in pregnant women: A systematic review and meta‐analysis of the diagnostic performance of ultrasonography
Objectives: The accuracy of ultrasound in the detection of appendicitis in pregnant women was examined in a meta‐analysis.Methods: Pregnant women with suspected acute appendicitis were evaluated using ultrasound in a systematic search of PubMed, EMBASE, and Cochrane Library databases from January 1, 2011 to August 10, 2023. The sensitivity and specificity values and diagnostic odds ratios were obtained using the pooled data.Results: A total of 239 patients were studied in four relevant investigations. Ultrasonography has a sensitivity of 56% and a specificity of 88% for the diagnosis of acute appendicitis, with an area under the receiver operating characteristic curve of 0.66%. Ultrasonography had a positive likelihood ratio of 4.65 (95% confidence interval, 1.42–15.23) and a negative likelihood ratio of 0.50 (95% confidence interval, 0.41–0.62). There was no evidence of publication bias (p = 0.93).Conclusions: Ultrasound has moderate sensitivity for identifying appendicitis in pregnant women and may be utilized as an alternative diagnostic method.
- 17 January 2022
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 50 (2) , 296-301
A deep learning classification of metacarpophalangeal joints synovial proliferation in rheumatoid arthritis by ultrasound images
Objective: To evaluate if an automatic classification of rheumatoid arthritis (RA) metacarpophalangeal joint conditions in ultrasound images is feasible by deep learning (DL) method, to provide a more objective, automated, and fast way of RA diagnosis in clinical setting.Materials and Methods: DenseNet‐based DL model was used and both training and testing are implemented in TensorFlow 1.13.1 with Keras DL libraries. The area under curve (AUC), accuracy, sensitivity, and specificity values with 95% CIs were reported. The statistical analysis was performed by using scikit‐learn libraries in Python 3.7.Results: A total of 1337 RA ultrasound images were acquired from 208 patients, the number of images is 313, 657, 178, and 189 in OESS Grade L0, L1, L2, and L3, respectively. In Classification Scenario 1 SP‐no versus SP‐yes, three experiments with region of interest of size 192 × 448 (Group 1), 96 × 224 (Group 2), and 96 × 224 stacked with pre‐segmented annotated mask of SP area (Group 3) as input achieve an AUC of 0.863 (95% CI: 0.809, 0.917), 0.861 (95% CI: 0.805, 0.916), and 0.886 (95% CI: 0.836, 0.936), respectively. In Classification Scenario 2 Healthy versus Diseased, experiments in Group 1, Group 2 and Group 3 achieve an AUC of 0.848 (95% CI: 0.799, 0.896), 0.864 (95% CI: 0.819, 0.909), and 0.916 (95% CI: 0.883, 0.952), respectively.Conclusion: We combined DenseNet model with ultrasound images for RA condition assessment. The feasibility of using DL to create an automatic RA condition classification system was also demonstrated. The proposed method can be an alternative to the initial screening of RA patients.
- 17 January 2022
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 50 (2) , 296-301
A deep learning classification of metacarpophalangeal joints synovial proliferation in rheumatoid arthritis by ultrasound images
Objective: To evaluate if an automatic classification of rheumatoid arthritis (RA) metacarpophalangeal joint conditions in ultrasound images is feasible by deep learning (DL) method, to provide a more objective, automated, and fast way of RA diagnosis in clinical setting.Materials and Methods: DenseNet‐based DL model was used and both training and testing are implemented in TensorFlow 1.13.1 with Keras DL libraries. The area under curve (AUC), accuracy, sensitivity, and specificity values with 95% CIs were reported. The statistical analysis was performed by using scikit‐learn libraries in Python 3.7.Results: A total of 1337 RA ultrasound images were acquired from 208 patients, the number of images is 313, 657, 178, and 189 in OESS Grade L0, L1, L2, and L3, respectively. In Classification Scenario 1 SP‐no versus SP‐yes, three experiments with region of interest of size 192 × 448 (Group 1), 96 × 224 (Group 2), and 96 × 224 stacked with pre‐segmented annotated mask of SP area (Group 3) as input achieve an AUC of 0.863 (95% CI: 0.809, 0.917), 0.861 (95% CI: 0.805, 0.916), and 0.886 (95% CI: 0.836, 0.936), respectively. In Classification Scenario 2 Healthy versus Diseased, experiments in Group 1, Group 2 and Group 3 achieve an AUC of 0.848 (95% CI: 0.799, 0.896), 0.864 (95% CI: 0.819, 0.909), and 0.916 (95% CI: 0.883, 0.952), respectively.Conclusion: We combined DenseNet model with ultrasound images for RA condition assessment. The feasibility of using DL to create an automatic RA condition classification system was also demonstrated. The proposed method can be an alternative to the initial screening of RA patients.
- 1 July 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (1) , 83-87
Clinical Value of the Elastographic Q‐Analysis Score in Assisting Real‐Time Elastography‐Guided Prostate Biopsy: A Retrospective Study of 125 Patients
Objectives: This study aimed to evaluate the clinical value of the elastographic Q‐analysis score (EQS) in assisting real‐time elastography‐ and transrectal US‐guided prostate biopsy.Methods: A total of 125 patients with 301 lesions were enrolled in this study; all were confirmed by pathologic results. The patients underwent transrectal US and elastographic examinations before biopsy. Elastographic Q‐analysis score analysis software was used for measuring the mean EQS of the elastic images. First, the suspicious regions on elastography underwent biopsy. Then 12‐core systematic prostate biopsy was performed. An EQS curve was used to calculate the mean EQS, and a receiver operating characteristic curve was drawn to find the cutoff point for the EQS to predict prostate cancer.Results: Of the 301 lesions in this study, 125 were malignant, and 176 were benign. The mean EQS values of benign and malignant lesions ± SD were 1.47 ± 0.75 and 2.98 ± 1.06, respectively. The difference was statistically significant (P < .05). The area under the receiver operating characteristic curve was 0.87. When the cutoff point was 1.95 for diagnosing malignant and benign lesions, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 83.5%, 84.4%, 76.8%, 89.2%, 5.35, and 0.20.Conclusions: The EQS could be used as a way to predict benign and malignant lesions and thus could serve as guidance for adding targeted biopsy.
- 1 July 2019
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (1) , 83-87
Clinical Value of the Elastographic Q‐Analysis Score in Assisting Real‐Time Elastography‐Guided Prostate Biopsy: A Retrospective Study of 125 Patients
Objectives: This study aimed to evaluate the clinical value of the elastographic Q‐analysis score (EQS) in assisting real‐time elastography‐ and transrectal US‐guided prostate biopsy.Methods: A total of 125 patients with 301 lesions were enrolled in this study; all were confirmed by pathologic results. The patients underwent transrectal US and elastographic examinations before biopsy. Elastographic Q‐analysis score analysis software was used for measuring the mean EQS of the elastic images. First, the suspicious regions on elastography underwent biopsy. Then 12‐core systematic prostate biopsy was performed. An EQS curve was used to calculate the mean EQS, and a receiver operating characteristic curve was drawn to find the cutoff point for the EQS to predict prostate cancer.Results: Of the 301 lesions in this study, 125 were malignant, and 176 were benign. The mean EQS values of benign and malignant lesions ± SD were 1.47 ± 0.75 and 2.98 ± 1.06, respectively. The difference was statistically significant (P < .05). The area under the receiver operating characteristic curve was 0.87. When the cutoff point was 1.95 for diagnosing malignant and benign lesions, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 83.5%, 84.4%, 76.8%, 89.2%, 5.35, and 0.20.Conclusions: The EQS could be used as a way to predict benign and malignant lesions and thus could serve as guidance for adding targeted biopsy.
- 28 December 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (8) , 2181-2190
Diagnostic Performance of Multimodal Sound Touch Elastography for Differentiating Benign and Malignant Breast Masses
Objectives: Evaluating the value of screening breast masses by separate or combined use of multimodal Sound Touch Elastography.Methods: Women with 159 masses (mean size, 14.86 ± 6.57 mm; range, 5.30–30.00 mm) were enrolled in the study. The pathology results were adopted as diagnostic standards. The abilities of Young's modulus (E), shear modulus (G), and shear wave (C) to differentiate malignant and benign breast masses based on receiver operating characteristic curves were evaluated, and the optimal cutoff values were obtained. Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were calculated. Then, the values were combined to perform an overall analysis of Sound Touch Elastography using evidence‐based medicine, construct forest plots, and calculate areas under the summary receiver operating characteristic curves, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic scores.Results: A total of 159 masses with a mean size of 14.86 ± 6.57 mm (range, 5.30–30.00 mm) were included. For the various parameters, the diagnostic values were as follows: Gmax > Emax > Cmax > Csd > Esd > Gsd > Emean > Gmean > Cmean. There were no significant differences in Emin, Gmin, or Cmin. When the 9 parameters were combined, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic scores and areas under the summary receiver operating characteristic curves were 84% (95% confidence interval [CI], 79%–88%), 82% (95% CI, 80%–84%), 4.75 (95% CI, 4.15–5.43), 0.20 (95% CI, 0.15–0.25), 3.19 (95% CI, 2.84–3.54) and 90.2% (95% CI, 87%–92%), respectively.Conclusions: Sound Touch Elastography can be recognized as a new ultrasound‐based diagnostic method for differentiation between benign and malignant breast masses.
- 28 December 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 38 (8) , 2181-2190
Diagnostic Performance of Multimodal Sound Touch Elastography for Differentiating Benign and Malignant Breast Masses
Objectives: Evaluating the value of screening breast masses by separate or combined use of multimodal Sound Touch Elastography.Methods: Women with 159 masses (mean size, 14.86 ± 6.57 mm; range, 5.30–30.00 mm) were enrolled in the study. The pathology results were adopted as diagnostic standards. The abilities of Young's modulus (E), shear modulus (G), and shear wave (C) to differentiate malignant and benign breast masses based on receiver operating characteristic curves were evaluated, and the optimal cutoff values were obtained. Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were calculated. Then, the values were combined to perform an overall analysis of Sound Touch Elastography using evidence‐based medicine, construct forest plots, and calculate areas under the summary receiver operating characteristic curves, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic scores.Results: A total of 159 masses with a mean size of 14.86 ± 6.57 mm (range, 5.30–30.00 mm) were included. For the various parameters, the diagnostic values were as follows: Gmax > Emax > Cmax > Csd > Esd > Gsd > Emean > Gmean > Cmean. There were no significant differences in Emin, Gmin, or Cmin. When the 9 parameters were combined, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic scores and areas under the summary receiver operating characteristic curves were 84% (95% confidence interval [CI], 79%–88%), 82% (95% CI, 80%–84%), 4.75 (95% CI, 4.15–5.43), 0.20 (95% CI, 0.15–0.25), 3.19 (95% CI, 2.84–3.54) and 90.2% (95% CI, 87%–92%), respectively.Conclusions: Sound Touch Elastography can be recognized as a new ultrasound‐based diagnostic method for differentiation between benign and malignant breast masses.