Johnathon M. Aho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johnathon M. Aho has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
- Martin Donald Zielinski
Department of Surgery, Mayo Clinic, Rochester, MN, USA
14 shared publications - Matthew C. Hernandez
Division of Trauma Critical Care and General Surgery, Department of Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
13 shared publications - Cornelius A. Thiels
Division of Hepatobiliary and Pancreas Surgery, Mayo Clinic, Rochester, Minnesota, USA
5 shared publications - Damian Luiz Clarke
Department of Surgery University of KwaZulu‐Natal Durban South Africa
5 shared publications - Victor Kong
Department of Surgery University of Auckland Auckland New Zealand
5 shared publications Cornelius A. Thiels
General Surgery, Department of Surgery Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905
3 shared publications
Latest Publications
- 22 July 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (1) , 59-63
Tension pneumothorax decompression with colorimetric capnography: pilot case series
Tension pneumothorax is a life-threatening condition that can develop when either the visceral pleura is disrupted, or with injury to the tracheobronchial tree. Rapid, accurate diagnosis and appropriate management are required to prevent significant atelectasis, hypoxia, circulatory arrest, and ultimate patient demise. Needle decompression is the current standard of care for the management of tension pneumothorax. Healthcare providers struggle to assess the success of decompression due to a lack of any immediate objective feedback. The gaseous composition of tension pneumothorax is similar to that of end respiratory gas. This includes an increased partial pressure of carbon dioxide in comparison to atmospheric air, which makes colorimetric capnography an ideal confirmatory test. This colorimetric capnography device may help the healthcare providers to make an objective and accurate assessment of the success of the needle decompression, in particular in prehospital environments.
- 22 July 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (1) , 59-63
Tension pneumothorax decompression with colorimetric capnography: pilot case series
Tension pneumothorax is a life-threatening condition that can develop when either the visceral pleura is disrupted, or with injury to the tracheobronchial tree. Rapid, accurate diagnosis and appropriate management are required to prevent significant atelectasis, hypoxia, circulatory arrest, and ultimate patient demise. Needle decompression is the current standard of care for the management of tension pneumothorax. Healthcare providers struggle to assess the success of decompression due to a lack of any immediate objective feedback. The gaseous composition of tension pneumothorax is similar to that of end respiratory gas. This includes an increased partial pressure of carbon dioxide in comparison to atmospheric air, which makes colorimetric capnography an ideal confirmatory test. This colorimetric capnography device may help the healthcare providers to make an objective and accurate assessment of the success of the needle decompression, in particular in prehospital environments.
- 3 September 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (2) , 391-393
“Decompression of tension pneumothorax in a trauma patient –first use of a novel decompression colorimetric capnography device in human patient”
Tension pneumothorax is a common cause of mortality in trauma. Tension pneumothorax is the confinement of respired gases within the pleural cavity at increasing pressure resulting in hemodynamic collapse. Decompression is crucial in management. Emergency needle thoracostomy is a life-saving maneuver that allows atmospheric pressure equilibration and partial restoration of cardiac filling. Needle decompressions are usually performed under noisy, tense, and stressful circumstances, and objective assessment of success is difficult in the field. A device which is simple that objectively informs operators of successful decompression would be clinically useful. In previous work, we have demonstrated end-expiratory gas and gaseous composition of tension pneumothorax are similar due to increased carbon dioxide partial pressure relative to atmospheric gas composition. Therefore, a simple solution to objective needle decompression may be colorimetric capnography. We report a case of 58-year-old male treated by EMS following a motorcycle accident with left-sided chest pain, hypoxia, hypotension, and clinical findings of tension pneumothorax. Needle decompression with colorimetric capnography using the device indicated decompression of his tension pneumothorax, with appropriate temporizing success.
- 3 September 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (2) , 391-393
“Decompression of tension pneumothorax in a trauma patient –first use of a novel decompression colorimetric capnography device in human patient”
Tension pneumothorax is a common cause of mortality in trauma. Tension pneumothorax is the confinement of respired gases within the pleural cavity at increasing pressure resulting in hemodynamic collapse. Decompression is crucial in management. Emergency needle thoracostomy is a life-saving maneuver that allows atmospheric pressure equilibration and partial restoration of cardiac filling. Needle decompressions are usually performed under noisy, tense, and stressful circumstances, and objective assessment of success is difficult in the field. A device which is simple that objectively informs operators of successful decompression would be clinically useful. In previous work, we have demonstrated end-expiratory gas and gaseous composition of tension pneumothorax are similar due to increased carbon dioxide partial pressure relative to atmospheric gas composition. Therefore, a simple solution to objective needle decompression may be colorimetric capnography. We report a case of 58-year-old male treated by EMS following a motorcycle accident with left-sided chest pain, hypoxia, hypotension, and clinical findings of tension pneumothorax. Needle decompression with colorimetric capnography using the device indicated decompression of his tension pneumothorax, with appropriate temporizing success.
- 31 July 2020
- Published by Wiley in World Journal of Surgery
- Vol. 44 (12) , 3993-3998
Damage Control Laparotomy: High‐Volume Centers Display Similar Mortality Rates Despite Differences in Country Income Level
Background: Comprehensive analysis of trauma care between high‐, middle‐, and low‐income countries (HIC/MIC/LIC) is needed to improve global health. Comparison of HIC and MIC outcomes after damage control laparotomy (DCL) for patients is unknown. We evaluated DCL utilization among patients treated at high‐volume trauma centers in the USA and South Africa, an MIC, hypothesizing similar mortality outcomes despite differences in resources and setting.Methods: Post hoc analysis of prospectively collected trauma databases from participating centers was performed. Injury severity, physiologic, operative data and post‐operative outcomes were abstracted. Univariate and multivariable analyses were performed to assess differences between HIC/MIC for the primary outcome of mortality.Results: There were 967 HIC and 602 MIC patients who underwent laparotomy. DCL occurred in 144 MIC patients (25%) and 241 HIC (24%) patients. Most sustained (58%) penetrating trauma with higher rates in the MIC compared to the HIC (71 vs. 32%, p = 0.001). Between groups, no differences were found for admission physiology, coagulopathy, or markers of shock except for increased presence of hypotension among patients in the HIC. Crystalloid infusion volumes were greater among MIC patients, and MIC patients received fewer blood products than those in the HIC. Overall mortality was 30% with similar rates between groups (29 in HIC vs. 33% in MIC, p = 0.4). On regression, base excess and penetrating injury were independent predictors of mortality but not patient residential status.Conclusion: Use and survival of DCL for patients with severe abdominal trauma was similar between trauma centers in HIC and MIC settings despite increased penetrating trauma and less transfusion in the MIC center. While the results overall suggest no gap in care for patients requiring DCL in this MIC, it highlights improvements that can be made in damage control resuscitation.
- 31 July 2020
- Published by Wiley in World Journal of Surgery
- Vol. 44 (12) , 3993-3998
Damage Control Laparotomy: High‐Volume Centers Display Similar Mortality Rates Despite Differences in Country Income Level
Background: Comprehensive analysis of trauma care between high‐, middle‐, and low‐income countries (HIC/MIC/LIC) is needed to improve global health. Comparison of HIC and MIC outcomes after damage control laparotomy (DCL) for patients is unknown. We evaluated DCL utilization among patients treated at high‐volume trauma centers in the USA and South Africa, an MIC, hypothesizing similar mortality outcomes despite differences in resources and setting.Methods: Post hoc analysis of prospectively collected trauma databases from participating centers was performed. Injury severity, physiologic, operative data and post‐operative outcomes were abstracted. Univariate and multivariable analyses were performed to assess differences between HIC/MIC for the primary outcome of mortality.Results: There were 967 HIC and 602 MIC patients who underwent laparotomy. DCL occurred in 144 MIC patients (25%) and 241 HIC (24%) patients. Most sustained (58%) penetrating trauma with higher rates in the MIC compared to the HIC (71 vs. 32%, p = 0.001). Between groups, no differences were found for admission physiology, coagulopathy, or markers of shock except for increased presence of hypotension among patients in the HIC. Crystalloid infusion volumes were greater among MIC patients, and MIC patients received fewer blood products than those in the HIC. Overall mortality was 30% with similar rates between groups (29 in HIC vs. 33% in MIC, p = 0.4). On regression, base excess and penetrating injury were independent predictors of mortality but not patient residential status.Conclusion: Use and survival of DCL for patients with severe abdominal trauma was similar between trauma centers in HIC and MIC settings despite increased penetrating trauma and less transfusion in the MIC center. While the results overall suggest no gap in care for patients requiring DCL in this MIC, it highlights improvements that can be made in damage control resuscitation.
- 1 April 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (4) , 627-631
Injury patterns and mechanisms related to refrigerator and freezer utilization in the United States
- 1 April 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (4) , 627-631
Injury patterns and mechanisms related to refrigerator and freezer utilization in the United States
- Open Access
A Truly Injectable Neural Stimulation Electrode Made from an In-Body Curing Polymer/Metal Composite
Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, we have developed a novel electrode that begins as an uncured, flowable pre-polymer that can be injected around a neuroanatomical target to minimize surgical manipulation. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, we performed detailed electrochemical and microscopy characterization of its material properties and validated the feasibility of using it to electrically stimulate the nervous system in rats and swine. The silicone-metal-particle composite performed very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of being simpler than traditional electrode designs, less invasive, and more cost-effective, the Injectrode has the potential to increase the adoption of neuromodulation therapies for existing and new indications.
Open AccessA Truly Injectable Neural Stimulation Electrode Made from an In-Body Curing Polymer/Metal Composite
Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, we have developed a novel electrode that begins as an uncured, flowable pre-polymer that can be injected around a neuroanatomical target to minimize surgical manipulation. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, we performed detailed electrochemical and microscopy characterization of its material properties and validated the feasibility of using it to electrically stimulate the nervous system in rats and swine. The silicone-metal-particle composite performed very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of being simpler than traditional electrode designs, less invasive, and more cost-effective, the Injectrode has the potential to increase the adoption of neuromodulation therapies for existing and new indications.
- 19 February 2019
- Published by Wiley in World Journal of Surgery
- Vol. 43 (7) , 1636-1643
Surgical Considerations for Pediatric Snake Bites in Low‐ and Middle‐Income Countries
Background: Snake envenomation is associated with major morbidity especially in low‐ and middle‐income countries and may require fasciotomy. We determined patient factors associated with the need for fasciotomy after venomous snake bites in children located in KwaZulu‐Natal, South Africa.Methods: Single institutional review of historical data (2012–2017) for children (n = 27, 38%) followed by legs (n = 18, 25%). Syndromes (according to Blaylock) included PPS (n = 63, 88%), PW (n = 5, 7%), and B (n = 4, 5%). Eighteen patients underwent fasciotomy, and one required above knee amputation. Nine patients received anti‐venom. Few patients (15%) received prophylactic beta‐lactam antibiotics. Hemoglobin < 11 mg/dL, leukocytosis, INR >1.2, and age‐adjusted shock index were associated with fasciotomy. On regression, age‐adjusted shock index and hemoglobin concentration < 11 mg/dL, presentation >24 h after snake bite, and INR >1.2 were independently associated with fasciotomy. Model sensitivity was 0.89 and demonstrated good fit.Conclusions: Patient factors were associated with the fasciotomy. These factors, coupled with clinical examination, may identify those who need early operative intervention. Improving time to treatment and the appropriate administration of anti‐venom will minimize the need for surgery.Level of evidence: III
- 19 February 2019
- Published by Wiley in World Journal of Surgery
- Vol. 43 (7) , 1636-1643
Surgical Considerations for Pediatric Snake Bites in Low‐ and Middle‐Income Countries
Background: Snake envenomation is associated with major morbidity especially in low‐ and middle‐income countries and may require fasciotomy. We determined patient factors associated with the need for fasciotomy after venomous snake bites in children located in KwaZulu‐Natal, South Africa.Methods: Single institutional review of historical data (2012–2017) for children (n = 27, 38%) followed by legs (n = 18, 25%). Syndromes (according to Blaylock) included PPS (n = 63, 88%), PW (n = 5, 7%), and B (n = 4, 5%). Eighteen patients underwent fasciotomy, and one required above knee amputation. Nine patients received anti‐venom. Few patients (15%) received prophylactic beta‐lactam antibiotics. Hemoglobin < 11 mg/dL, leukocytosis, INR >1.2, and age‐adjusted shock index were associated with fasciotomy. On regression, age‐adjusted shock index and hemoglobin concentration < 11 mg/dL, presentation >24 h after snake bite, and INR >1.2 were independently associated with fasciotomy. Model sensitivity was 0.89 and demonstrated good fit.Conclusions: Patient factors were associated with the fasciotomy. These factors, coupled with clinical examination, may identify those who need early operative intervention. Improving time to treatment and the appropriate administration of anti‐venom will minimize the need for surgery.Level of evidence: III
- 1 May 2018
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 36 (5) , 846-850
Weekend woodsmen: Overview and comparison of injury patterns associated with power saw and axe utilization in the United States
- 1 May 2018
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 36 (5) , 846-850
Weekend woodsmen: Overview and comparison of injury patterns associated with power saw and axe utilization in the United States
- Open Access
- 7 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-16
Long-term regeneration and remodeling of the pig esophagus after circumferential resection using a retrievable synthetic scaffold carrying autologous cells
Treatment of esophageal disease can necessitate resection and reconstruction of the esophagus. Current reconstruction approaches are limited to utilization of an autologous conduit such as stomach, small bowel, or colon. A tissue engineered construct providing an alternative for esophageal replacement in circumferential, full thickness resection would have significant clinical applications. In the current study, we demonstrate that regeneration of esophageal tissue is feasible and reproducible in a large animal model using synthetic polyurethane electro-spun grafts seeded with autologous adipose-derived mesenchymal stem cells (aMSCs) and a disposable bioreactor. The scaffolds were not incorporated into the regrown esophageal tissue and were retrieved endoscopically. Animals underwent adipose tissue biopsy to harvest and expand autologous aMSCs for seeding on electro-spun polyurethane conduits in a bioreactor. Anesthetized pigs underwent full thickness circumferential resection of the mid-lower thoracic esophagus followed by implantation of the cell seeded scaffold. Results from these animals showed gradual structural regrowth of endogenous esophageal tissue, including squamous esophageal mucosa, submucosa, and smooth muscle layers with blood vessel formation. Scaffolds carrying autologous adipose-derived mesenchymal stem cells may provide an alternative to the use of a gastro-intestinal conduit for some patients following resection of the esophagus.
- 7 March 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-16
Open AccessLong-term regeneration and remodeling of the pig esophagus after circumferential resection using a retrievable synthetic scaffold carrying autologous cells
Treatment of esophageal disease can necessitate resection and reconstruction of the esophagus. Current reconstruction approaches are limited to utilization of an autologous conduit such as stomach, small bowel, or colon. A tissue engineered construct providing an alternative for esophageal replacement in circumferential, full thickness resection would have significant clinical applications. In the current study, we demonstrate that regeneration of esophageal tissue is feasible and reproducible in a large animal model using synthetic polyurethane electro-spun grafts seeded with autologous adipose-derived mesenchymal stem cells (aMSCs) and a disposable bioreactor. The scaffolds were not incorporated into the regrown esophageal tissue and were retrieved endoscopically. Animals underwent adipose tissue biopsy to harvest and expand autologous aMSCs for seeding on electro-spun polyurethane conduits in a bioreactor. Anesthetized pigs underwent full thickness circumferential resection of the mid-lower thoracic esophagus followed by implantation of the cell seeded scaffold. Results from these animals showed gradual structural regrowth of endogenous esophageal tissue, including squamous esophageal mucosa, submucosa, and smooth muscle layers with blood vessel formation. Scaffolds carrying autologous adipose-derived mesenchymal stem cells may provide an alternative to the use of a gastro-intestinal conduit for some patients following resection of the esophagus.
- 1 January 2018
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 36 (1) , 114-119
Definitive airway management after pre-hospital supraglottic airway insertion: Outcomes and a management algorithm for trauma patients
- 1 January 2018
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 36 (1) , 114-119
Definitive airway management after pre-hospital supraglottic airway insertion: Outcomes and a management algorithm for trauma patients