Philipp-Cornelius Pott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Philipp-Cornelius Pott has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Meike Stiesch
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
10 shared publicationsMichael Eisenburger
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
7 shared publicationsM. Stiesch
Klinik für Zahnärztliche Prothetik und Biomedizinische Werkstoffkunde, Medizinische Hochschule Hannover, Hannover, Deutschland
4 shared publications- Christian Klose
Institut für Werkstoffkunde (Materials Science), Leibniz University Hannover, Garbsen, Germany
3 shared publications M. Eisenburger
Klinik für Zahnärztliche Prothetik und Biomedizinische Werkstoffkunde, Medizinische Hochschule Hannover, Hannover, Deutschland
3 shared publications- Meike Stiesch
Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany
3 shared publications
Latest Publications
- Open Access
- 31 July 2026
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 38 (8) , 106
Color stability of CAD/CAM and additively manufactured resin materials: influence of surface treatment and layer thickness - an in vitro study
- 31 July 2026
- Published by Springer Nature in The Saudi Dental Journal
- Vol. 38 (8) , 106
Open AccessColor stability of CAD/CAM and additively manufactured resin materials: influence of surface treatment and layer thickness - an in vitro study
- Open Access
- 13 February 2026
- Published by Elsevier in Manufacturing Letters
- Vol. 47, 74-77
Co-extrusion of internally oxidized Nb-1Zr: An avenue to new load-bearing implants
- 13 February 2026
- Published by Elsevier in Manufacturing Letters
- Vol. 47, 74-77
Open AccessCo-extrusion of internally oxidized Nb-1Zr: An avenue to new load-bearing implants
- Open Access
- 8 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Influence of the design of modern subperiosteal multivectorial anchored Implants on success and survival in complex patient cases
This study investigates factors relating to the success and survival of patient-specific subperiosteally multivectorial anchored implants (IPS-Implant) with a minimum of two coupling elements (CE) to anchor the prosthetic restoration in challenging patient situations. Construction parameters of the implants were analyzed. Implantation timepoint, complications, and complication severity using USPHS criteria (A–D) were obtained from patients records. CE-location, spacing, length and transmucosal height were evaluated for their influence. The medial plaque (mPI) and the gingival (GI) indices were evaluated in order to assess inflammations around the CE. Success and survival rates were analyzed via Kaplan–Meier analysis and log-rank tests. In fifteen patients (6 men, 9 women) aged 40 to 92 in total 49 CE were examined. Kaplan–Meier analysis revealed a 2-year success rate of 91.6% and survival rate of 97.5%, while long-term analysis showed a success rate of 53.9% and survival rate of 89.4% after 8.9 years in total. Only 3 CE got lost due to fracture of the supporting bone. 46 CE are still in clinical use. After 1.8 years in the earliest, in 18 cases, signs for inflammation were detected. 10 of these inflammations required medical care. Subperiosteal implants show good short-term results but often face soft-tissue complications over time. Neighboring natural teeth and distances between coupling elements < 10 mm increased the risk for complications. Implant design, surface finish, and prosthetic protection are crucial for long-term success, requiring further research.
- 8 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Open AccessInfluence of the design of modern subperiosteal multivectorial anchored Implants on success and survival in complex patient cases
This study investigates factors relating to the success and survival of patient-specific subperiosteally multivectorial anchored implants (IPS-Implant) with a minimum of two coupling elements (CE) to anchor the prosthetic restoration in challenging patient situations. Construction parameters of the implants were analyzed. Implantation timepoint, complications, and complication severity using USPHS criteria (A–D) were obtained from patients records. CE-location, spacing, length and transmucosal height were evaluated for their influence. The medial plaque (mPI) and the gingival (GI) indices were evaluated in order to assess inflammations around the CE. Success and survival rates were analyzed via Kaplan–Meier analysis and log-rank tests. In fifteen patients (6 men, 9 women) aged 40 to 92 in total 49 CE were examined. Kaplan–Meier analysis revealed a 2-year success rate of 91.6% and survival rate of 97.5%, while long-term analysis showed a success rate of 53.9% and survival rate of 89.4% after 8.9 years in total. Only 3 CE got lost due to fracture of the supporting bone. 46 CE are still in clinical use. After 1.8 years in the earliest, in 18 cases, signs for inflammation were detected. 10 of these inflammations required medical care. Subperiosteal implants show good short-term results but often face soft-tissue complications over time. Neighboring natural teeth and distances between coupling elements < 10 mm increased the risk for complications. Implant design, surface finish, and prosthetic protection are crucial for long-term success, requiring further research.
- Open Access
- 10 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-15
Patients’ trajectory from tooth loss to dental rehabilitation and living with implant-supported dentures – a qualitative interview study
Background: Since their introduction, implant-supported dentures have gained increasing popularity and are associated with high expectations. Nevertheless, as with other invasive procedures, implant treatment involves post-surgical risks as well as the risk of long-term complications. The present study aimed at exploring patients’ experiences of the entire trajectory of dental implant-treatment, to reach a profound understanding of the patients’ perception of the course of their journey from tooth loss to living with implant-supported dentures. Methods: The single-site study employed an exploratory, qualitative design with semi-structured interviews conducted with patients who had received implant-supported dentures for different indications at least one year prior. Thirty-three patients were consecutively recruited by dentists during regular check-ups from March to September 2023 at a German university dental clinic. Interview data were analyzed using deductive-inductive qualitative content analysis. Results: Of the 33 patients five patients did not return the consent-to-contact form, and one withdrew their consent, resulting in a final sample of 27 patients (82%). The participants held high expectations regarding the function, durability, and – in cases involving visible tooth gaps – aesthetic outcomes of their implants. Key concerns influencing treatment decisions included the need for bone augmentation and transplantation, age-related factors, and procedural risks. Notwithstanding the lengthy, stepwise nature of the treatment process, the considerable symptom burden, and the high financial cost, most patients considered the implant treatment worthwhile and felt well informed. With one exception the majority of participants (96.3%) reported that their implant-supported dentures functioned and appeared similar to their natural teeth. However, while satisfied with their implant-supported denture, two participants (7.4%) experienced persistent suffering due to temporomandibular disorder and persistent pain following treatment. The issue of prolonged facial pain has arguably been overlooked in aftercare of these patients. Conclusions: Dental implants are generally viewed as preferred option for oral rehabilitation. The results underline the importance of comprehensive counselling and after care irrespectively of the complexity of the treatment. While iatrogenic complications and the risk of their chronification are rare, careful attention to these risks remains essential. Further research, encompassing prospective longitudinal studies, is needed, given the risk of recall bias. Clinical trial registration: Does not apply.
- 10 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-15
Open AccessPatients’ trajectory from tooth loss to dental rehabilitation and living with implant-supported dentures – a qualitative interview study
Background: Since their introduction, implant-supported dentures have gained increasing popularity and are associated with high expectations. Nevertheless, as with other invasive procedures, implant treatment involves post-surgical risks as well as the risk of long-term complications. The present study aimed at exploring patients’ experiences of the entire trajectory of dental implant-treatment, to reach a profound understanding of the patients’ perception of the course of their journey from tooth loss to living with implant-supported dentures. Methods: The single-site study employed an exploratory, qualitative design with semi-structured interviews conducted with patients who had received implant-supported dentures for different indications at least one year prior. Thirty-three patients were consecutively recruited by dentists during regular check-ups from March to September 2023 at a German university dental clinic. Interview data were analyzed using deductive-inductive qualitative content analysis. Results: Of the 33 patients five patients did not return the consent-to-contact form, and one withdrew their consent, resulting in a final sample of 27 patients (82%). The participants held high expectations regarding the function, durability, and – in cases involving visible tooth gaps – aesthetic outcomes of their implants. Key concerns influencing treatment decisions included the need for bone augmentation and transplantation, age-related factors, and procedural risks. Notwithstanding the lengthy, stepwise nature of the treatment process, the considerable symptom burden, and the high financial cost, most patients considered the implant treatment worthwhile and felt well informed. With one exception the majority of participants (96.3%) reported that their implant-supported dentures functioned and appeared similar to their natural teeth. However, while satisfied with their implant-supported denture, two participants (7.4%) experienced persistent suffering due to temporomandibular disorder and persistent pain following treatment. The issue of prolonged facial pain has arguably been overlooked in aftercare of these patients. Conclusions: Dental implants are generally viewed as preferred option for oral rehabilitation. The results underline the importance of comprehensive counselling and after care irrespectively of the complexity of the treatment. While iatrogenic complications and the risk of their chronification are rare, careful attention to these risks remains essential. Further research, encompassing prospective longitudinal studies, is needed, given the risk of recall bias. Clinical trial registration: Does not apply.
- Open Access
- 15 January 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 36 (1) , 1-8
Load-bearing capacity of an experimental dental implant made of Nb-1Zr
Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V. A standardized abutment made of Ti6Al4V was fabricated for each implant and screwed into the implant with a screw made of the same material. A shape-identical crown for an upper first molar was fabricated for all implants using the CAD/CAM technique. All specimens were artificially aged using chewing simulation for 1 × 10 6 cycles and thermocycling between 5 °C and 55 °C for 4 × 10 3 cycles. After that, all specimens were loaded until failure. This was followed by a 3D analysis of the deformation of the samples. 100% of the samples survived the artificial aging. The Nb1Zr samples failed at 2595 ± 1069 N. In the Ti6Al4V group, failure occurred at 2958 ± 1058 N. The first deformations occurred in both groups from a load of at least 1114 N. The 3D analysis revealed deformations of 0.08 mm in the implant shoulder area of the Nb1Zr implants and of 0.04 mm in the Ti6Al4V implants. This difference was significant ( p = 0.016). The investigated Nb1Zr alloy appears to be suitable for implants. The measured load-bearing capacity is significantly higher than the expected intraoral masticatory forces. Graphical Abstract
- 15 January 2025
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 36 (1) , 1-8
Open AccessLoad-bearing capacity of an experimental dental implant made of Nb-1Zr
Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V. A standardized abutment made of Ti6Al4V was fabricated for each implant and screwed into the implant with a screw made of the same material. A shape-identical crown for an upper first molar was fabricated for all implants using the CAD/CAM technique. All specimens were artificially aged using chewing simulation for 1 × 10 6 cycles and thermocycling between 5 °C and 55 °C for 4 × 10 3 cycles. After that, all specimens were loaded until failure. This was followed by a 3D analysis of the deformation of the samples. 100% of the samples survived the artificial aging. The Nb1Zr samples failed at 2595 ± 1069 N. In the Ti6Al4V group, failure occurred at 2958 ± 1058 N. The first deformations occurred in both groups from a load of at least 1114 N. The 3D analysis revealed deformations of 0.08 mm in the implant shoulder area of the Nb1Zr implants and of 0.04 mm in the Ti6Al4V implants. This difference was significant ( p = 0.016). The investigated Nb1Zr alloy appears to be suitable for implants. The measured load-bearing capacity is significantly higher than the expected intraoral masticatory forces. Graphical Abstract
- Open Access
- 18 November 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (11) , e0313964
Influence of the use of an adhesive connection on the joint strength of modular hip endoprostheses
Introduction: Modular hip implants enables a more precise adaptation of the prosthesis to the patient’s anatomy. However, they also carry the risk of increased revision rates due to micromotion at the taper junction. In order to minimize this risk, one potential solution is to establish an adhesive bond between the metal taper junctions. Load-stable bonding techniques, already successfully employed in dentistry for connecting materials such as metals and ceramics or different alloys, offer a promising approach. Nevertheless, the bond strength of tapered adhesive bonds in modular hip implants has not been investigated to date. Materials and methods: Twenty-eight tapered junctions, consisting of a taper (female taper) and a trunnion (male taper) were turned using TiAl6V4 ELI (n = 16) and CoCr28Mo6 (n = 12). The process parameters cutting speed (vc = 50 m/min or 100 m/min) and feed (f = 0.1 mm, 0.05 mm or 0.2 mm) were varied for the trunnions. For each set of process parameters, one trunnion and one taper were additionally subjected to sandblasting. To investigate the effect of geometry, angular mismatch in the samples were measured. The taper pairs were bonded with a biocompatible adhesive, and push-out tests were subsequently performed. Results: The push-out forces generated from the taper connections where both tapers were sandblasted showed a mean push-out force of 5.70 kN. For the samples with only the trunnion sandblasted, the mean force was 0.58 kN, while for the samples with only taper sandblasted the mean push-out force was 1.32 kN. When neither of the tapers was sandblasted the mean push-out force was 0.91 kN. No significant effect of the process parameters on the push-out force was observed. Only the reduced valley depth Svk showed a slight correlation for the CoCr28Mo6 samples (R2 = 0.54). The taper pairs with taper mismatch (between trunnion and taper) greater than |0.1°| did not show lower push-out forces than the specimens with lower taper mismatch. Conclusions: Sandblasted and adhesive-bonded tapered connections represent a viable suitable alternative for modular hip implant connections. Slight differences in taper geometry do not result in reduced push-out forces and are compensated by the adhesive. In mechanically joined tapers these differences can lead to higher wear rates. Further investigation under realistic test conditions is necessary to assess long-term suitability.
- 18 November 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (11) , e0313964
Open AccessInfluence of the use of an adhesive connection on the joint strength of modular hip endoprostheses
Introduction: Modular hip implants enables a more precise adaptation of the prosthesis to the patient’s anatomy. However, they also carry the risk of increased revision rates due to micromotion at the taper junction. In order to minimize this risk, one potential solution is to establish an adhesive bond between the metal taper junctions. Load-stable bonding techniques, already successfully employed in dentistry for connecting materials such as metals and ceramics or different alloys, offer a promising approach. Nevertheless, the bond strength of tapered adhesive bonds in modular hip implants has not been investigated to date. Materials and methods: Twenty-eight tapered junctions, consisting of a taper (female taper) and a trunnion (male taper) were turned using TiAl6V4 ELI (n = 16) and CoCr28Mo6 (n = 12). The process parameters cutting speed (vc = 50 m/min or 100 m/min) and feed (f = 0.1 mm, 0.05 mm or 0.2 mm) were varied for the trunnions. For each set of process parameters, one trunnion and one taper were additionally subjected to sandblasting. To investigate the effect of geometry, angular mismatch in the samples were measured. The taper pairs were bonded with a biocompatible adhesive, and push-out tests were subsequently performed. Results: The push-out forces generated from the taper connections where both tapers were sandblasted showed a mean push-out force of 5.70 kN. For the samples with only the trunnion sandblasted, the mean force was 0.58 kN, while for the samples with only taper sandblasted the mean push-out force was 1.32 kN. When neither of the tapers was sandblasted the mean push-out force was 0.91 kN. No significant effect of the process parameters on the push-out force was observed. Only the reduced valley depth Svk showed a slight correlation for the CoCr28Mo6 samples (R2 = 0.54). The taper pairs with taper mismatch (between trunnion and taper) greater than |0.1°| did not show lower push-out forces than the specimens with lower taper mismatch. Conclusions: Sandblasted and adhesive-bonded tapered connections represent a viable suitable alternative for modular hip implant connections. Slight differences in taper geometry do not result in reduced push-out forces and are compensated by the adhesive. In mechanically joined tapers these differences can lead to higher wear rates. Further investigation under realistic test conditions is necessary to assess long-term suitability.
- Open Access
- 12 September 2024
- Published by Wiley in Advanced Engineering Materials
- Vol. 26 (22)
Co‐extrusion of Nb–1Zr Powder for the Production of a Biocompatible High‐Strength Material for Dental Implants
Many metallic implant materials, such as Ti–6Al–4V, contain elements that are now considered to be critical and have high Young's modulus compared to the human bone, leading to stress shielding. Nb–1Zr alloys, which are free of toxic elements and feature Young's modulus closer to human bone, present a promising alternative. The present study investigates the co‐extrusion of a biocompatible Nb–1Zr powder for potential use in dental implants. A process chain to coextrude Nb–1Zr powder into a solid body was developed, focusing on eliminating core fractures and reducing void fraction. Experimental parameters, including die angle, preheating temperature, and extrusion ratio, were optimized to achieve a continuous Nb–1Zr core. Metallographic analysis and mechanical testing reveal that profiles extruded at 1275 °C exhibit the most favorable properties, with a minimal void fraction of 0.003%, good compressive strength of 457 MPa, and microhardness of 180 HV 1. Controlled oxidation of the powder further enhances hardness to 501 HV 1, achieving values similar to Ti–6Al–4V. The findings demonstrate the feasibility of producing high‐strength, biocompatible Nb–1Zr profiles through optimized co‐extrusion processes.
- 12 September 2024
- Published by Wiley in Advanced Engineering Materials
- Vol. 26 (22)
Open AccessCo‐extrusion of Nb–1Zr Powder for the Production of a Biocompatible High‐Strength Material for Dental Implants
Many metallic implant materials, such as Ti–6Al–4V, contain elements that are now considered to be critical and have high Young's modulus compared to the human bone, leading to stress shielding. Nb–1Zr alloys, which are free of toxic elements and feature Young's modulus closer to human bone, present a promising alternative. The present study investigates the co‐extrusion of a biocompatible Nb–1Zr powder for potential use in dental implants. A process chain to coextrude Nb–1Zr powder into a solid body was developed, focusing on eliminating core fractures and reducing void fraction. Experimental parameters, including die angle, preheating temperature, and extrusion ratio, were optimized to achieve a continuous Nb–1Zr core. Metallographic analysis and mechanical testing reveal that profiles extruded at 1275 °C exhibit the most favorable properties, with a minimal void fraction of 0.003%, good compressive strength of 457 MPa, and microhardness of 180 HV 1. Controlled oxidation of the powder further enhances hardness to 501 HV 1, achieving values similar to Ti–6Al–4V. The findings demonstrate the feasibility of producing high‐strength, biocompatible Nb–1Zr profiles through optimized co‐extrusion processes.
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (5) , 267-277
Success rate of all-ceramic FPDs depending on the time of restoration between 2011 and 2023
Pott PC, et al. J Adv Prosthodont. 2024 Oct;16(5):267-277. https://doi.org/10.4047/jap.2024.16.5.267
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (5) , 267-277
Open AccessSuccess rate of all-ceramic FPDs depending on the time of restoration between 2011 and 2023
Pott PC, et al. J Adv Prosthodont. 2024 Oct;16(5):267-277. https://doi.org/10.4047/jap.2024.16.5.267
- 1 December 2021
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 130 (12) , 589-594
Genauigkeit eines scanbaren Materials für Durchbissregistrate im teildigitalen Workflow
Zusammenfassung: Digitale Prozessketten sind heute fester Bestandteil moderner Zahnmedizin und können bei komplexen Versorgungen mit konventionellen Abläufen zu teildigitalen Workflows kombiniert werden. Durchbissregistrate eignen sich dabei für die Modellzuordnung im Artikulator. Ziel dieser Studie war es, ein scanbares Bissnahmesilikon (Registrado Scan [RS], VOCO GmbH) und Vergleichsmaterialien (Registrado Xtra [RX] und Registrado Clear [RC], VOCO GmbH) hinsichtlich der Genauigkeit zu untersuchen. Dafür wurden bei insgesamt 40 Proband*innen Registrate durchgeführt, und mittels farbsensitivem Intraoralscan wurden intraorale angefärbte Kontakte als Referenz dokumentiert. Ober- und Unterkiefermodelle der Proband*innen wurden im Artikulator in Okklusion gebracht und digitalisiert. Die Abweichung der sich ergebenden Kontaktpunkte auf den Modellen zur intraoral erhobenen Referenz wurde in einer 3-D-Software vermessen.Es konnte gezeigt werden, dass sich die Werte in den Gruppen RS (0,52 ± 0,56 mm), RX (0,55 ± 0,53 mm) und RC (0,58 ± 0,53 mm) nicht signifikant voneinander unterscheiden (p ≥ 0,136). Das scanbare Material kann demnach sowohl in volldigitalen, in teildigitalen und auch in konventionellen Workflows angewendet werden.
- 1 December 2021
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 130 (12) , 589-594
Genauigkeit eines scanbaren Materials für Durchbissregistrate im teildigitalen Workflow
Zusammenfassung: Digitale Prozessketten sind heute fester Bestandteil moderner Zahnmedizin und können bei komplexen Versorgungen mit konventionellen Abläufen zu teildigitalen Workflows kombiniert werden. Durchbissregistrate eignen sich dabei für die Modellzuordnung im Artikulator. Ziel dieser Studie war es, ein scanbares Bissnahmesilikon (Registrado Scan [RS], VOCO GmbH) und Vergleichsmaterialien (Registrado Xtra [RX] und Registrado Clear [RC], VOCO GmbH) hinsichtlich der Genauigkeit zu untersuchen. Dafür wurden bei insgesamt 40 Proband*innen Registrate durchgeführt, und mittels farbsensitivem Intraoralscan wurden intraorale angefärbte Kontakte als Referenz dokumentiert. Ober- und Unterkiefermodelle der Proband*innen wurden im Artikulator in Okklusion gebracht und digitalisiert. Die Abweichung der sich ergebenden Kontaktpunkte auf den Modellen zur intraoral erhobenen Referenz wurde in einer 3-D-Software vermessen.Es konnte gezeigt werden, dass sich die Werte in den Gruppen RS (0,52 ± 0,56 mm), RX (0,55 ± 0,53 mm) und RC (0,58 ± 0,53 mm) nicht signifikant voneinander unterscheiden (p ≥ 0,136). Das scanbare Material kann demnach sowohl in volldigitalen, in teildigitalen und auch in konventionellen Workflows angewendet werden.
- 9 August 2019
- Published by Springer Nature in wissen kompakt
- Vol. 13 (3) , 161-169
Komplikationsmanagement bei dentalen keramischen Systemen
- 9 August 2019
- Published by Springer Nature in wissen kompakt
- Vol. 13 (3) , 161-169
Komplikationsmanagement bei dentalen keramischen Systemen