JOJunhyoung Oh

Junhyoung Oh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Junhyoung Oh has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Kyungho Lee

    School of Cybersecurity, Korea University, Seoul, South Korea

    6 shared publications
  • Hyewon Han

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea

    3 shared publications
  • Janghun Hyeon

    Department of Artificial Intelligence Software, Hanbat National University, Daejeon, Republic of Korea

    3 shared publications
  • Aram Kim

    Department of Information Security, College of Intelligent SW Convergence, The University of Suwon, Hwaseong-si 18323, Republic of Korea

    2 shared publications
  • Dongsin Kim

    Department of Computer Engineering, Hongik University, Seoul, Republic of Korea

    2 shared publications
  • Byung-Euk Joo

    Department of Neurology, Soonchunhyang University Seoul Hospital, Soonchunhyang University, Seoul, South Korea

    1 shared publication

Latest Publications

  • Open Access

    Can Synthetic Data Protect Privacy?

    by Gidan Min, Junhyoung Oh

    To systematically evaluate the privacy protection performance of synthetic data generation algorithms (Synthpop, CTGAN, RTVAE, TVAE, DataSynthesizer), this study applied various safety metrics. Synthetic data is designed to protect sensitive information while maintaining statistical similarities to the original data, but a high degree of similarity can increase the risk of re-identification. Therefore, privacy protection was measured using metrics such as DCR, NNDR, Identification Risk Indicator, Inference Risk Indicator, CM3, DUPI, and pMSE. The results showed that Synthpop provided high data utility, but its high similarity to the original data posed significant privacy risks. Conversely, DataSynthesizer and CTGAN demonstrated superior privacy protection by balancing utility and privacy effectively. RTVAE and TVAE maintained a clear distinction from the original data, enhancing privacy protection, though some cases showed decreased data utility. These findings suggest the importance of selecting algorithms based on specific privacy and utility requirements, emphasizing the need to consider the trade-off between data utility and privacy protection depending on dataset characteristics.


  • Top Cited Papers
    Open Access

    Navigating Privacy: A Global Comparative Analysis of Data Protection Laws

    by Sungjin Lim, Junhyoung Oh

    The increasing reliance on big data and artificial intelligence (AI) in the Fourth Industrial Revolution has raised significant concerns about individual privacy protection. This has led various countries to enact or amend privacy protection acts to address these concerns. However, there is a lack of comprehensive research comparing these laws across multiple countries, especially considering recent legislative developments. This study fills this gap by conducting a comparative analysis of privacy information protection acts in five major regions: the European Union (EU), the United States (focusing on California), China, Japan, and South Korea. The analysis explores the diverse approaches to privacy protection adopted by each region, influenced by their unique historical, political, and cultural contexts. For instance, the EU’s General Data Protection Regulation (GDPR) emphasizes individual rights influenced by historical abuses of personal information. At the same time, the California Consumer Privacy Act (CCPA) prioritizes consumer rights within a self‐regulatory framework, reflecting the state’s technology‐driven economy. The study also examines China’s Personal Information Protection Law (PIPL), which prioritizes national security; Japan’s Act on the Protection of Personal Information (APPI), which navigates the tension between individual privacy and societal norms; and South Korea’s Personal Information Protection Act (PIPA), which balances individual autonomy with a sense of community, reflecting Confucian values. By identifying specific limitations and areas for improvement in each region’s data protection laws, this study contributes to the ongoing discourse on international data privacy regulation. It offers valuable insights for policymakers and stakeholders seeking to navigate the complexities of the data economy while ensuring robust safeguards for individual privacy.


  • Open Access

    Classification and automatic scoring of arousal intensity during sleep stages using machine learning

    by Hyewon Han, Min Jae Seong, Janghun Hyeon, Eunyeon Joo, Junhyoung Oh

    Arousal during sleep can result in sleep fragmentation and various physiological effects, impairing cognitive function and raising blood pressure and heart rate. However, the current definition of arousal has limitations in assessing both amplitude and duration, making it challenging to measure sleep fragmentation accurately. Moreover, there is inconsistency among inter-raters in arousal scoring, which renders it susceptible to subjective variability. Therefore, this study aims to identify a highly accurate classifier for each sleep stage by employing optimized feature selection and machine learning models. According to electroencephalography (EEG) signals during the arousal phase, the intensity level was categorized into four levels. For control, the non-arousal cases were used as level 0 and referred as sham arousal, resulting in five arousal intensity levels. Wavelet transform was applied to analyze sleep arousal to extract features from EEG. Based on these features, we classified arousal intensity levels through machine learning algorithms. Due to the different characteristics of EEG in each sleep stage, the classification model was optimized for the four sleep stages. Excluding sham arousals, a total of 13,532 arousal events were used. The lowest intensity in the entire data, level 1, was computed to be 3107, level 2 was 3384, level 3 was 3472, and the highest intensity of level 4 was 3,569. The optimized classification model for each sleep stage achieved an average sensitivity of 82.68%, specificity of 95.68%, and AUROC of 96.30%. The sensitivity of the control, arousal intensity level 0, was 83.07%, a 1.25% increase over the unoptimized model and a 14.22% increase over previous research. This study used machine learning techniques to develop classifiers for each sleep stage, improving the accuracy of arousal intensity classification. The classifiers showed high sensitivity and specificity and revealed the unique characteristics of arousal intensity during different sleep stages. These findings represent a novel approach to arousal research and have implications for developing more accurate predictive models in sleep research.


  • Open Access

    A novel sleep aid device to reduce sleep latency using air–CO2 mixed gas

    by Hyewon Han, Dongsin Kim, Jin Seok Kim, Lee Ku Kwac, Janghun Hyeon, Junhyoung Oh

    Introduction: Sleep is an indispensable component of human life. However, in modern times, the number of people suffering from sleep disorders, such as insomnia and sleep deprivation, has increased significantly. Therefore, to alleviate the discomfort to the patient due to lack of sleep, sleeping pills and various sleep aids are being introduced and used. However, sleeping drugs are prescribed only to a limited extent due to the side effects posed by them and resistance to such drugs developed by patients in the long term, and the majority of sleep aids are scientifically groundless products. This study aimed to develop a device that induced sleep by spraying a mixed gas of carbon dioxide and air to create an environment that could induce sleep, similar to the inside of a sealed vehicle, to control oxygen saturation in the body.Methods: Based on the stipulated safety standards and the human tidal volume, the target concentration of carbon dioxide was determined to be of three types: 15,000, 20,000, and 25,000 ppm. After analyzing diverse structures for safely mixing gases, the most appropriate shape, the reserve tank, was selected as the best suited structure. Various variables, such as spraying angle and distance, flow rate, atmospheric temperature, and nozzle length, were comprehensively measured and tested. Furthermore based on this aspect, diffusion simulation of carbon dioxide concentration and actual experiments were conducted. To secure the stability and reliability of the developed product, an accredited test was performed to investigate the error rate of carbon dioxide concentration. Furthermore, clinical trials comprising polysomnography and questionnaires confirmed the effectiveness of the developed product not only in reducing sleep latency but also in enhancing the overall sleep quality.Results: When the developed device was put to use in reality, sleep latency was decreased by 29.01%, on average, for those with a sleep latency of 5 min or more, compared to when the device was not in use. Moreover, the total sleep time was increased by 29.19 min, WASO was decreased by 13.17%, and sleep efficiency was increased by 5.48%. We also affirmed that the ODI and 90% ODI did not decrease when the device was used. Although different questions may be raised about the safety of using a gas such as carbon dioxide (CO2), the result that tODI was not reduced shows that sleep aids using CO2 mixtures do not adversely affect human health.Discussion: The results of this study suggest a new method that can be used to treat sleep disorders including insomnia.


  • Open Access

    Application of various machine learning techniques to predict obstructive sleep apnea syndrome severity

    by Hyewon Han, Junhyoung Oh

    As the incidence of obstructive sleep apnea syndrome (OSAS) increases worldwide, the need for a new screening method that can compensate for the shortcomings of the traditional diagnostic method, polysomnography (PSG), is emerging. In this study, data from 4014 patients were used, and both supervised and unsupervised learning methods were used. Clustering was conducted with hierarchical agglomerative clustering, K-means, bisecting K-means algorithm, Gaussian mixture model, and feature engineering was carried out using both medically researched methods and machine learning techniques. For classification, we used gradient boost-based models such as XGBoost, LightGBM, CatBoost, and Random Forest to predict the severity of OSAS. The developed model showed high performance with 88%, 88%, and 91% of classification accuracy for three thresholds for the severity of OSAS: Apnea-Hypopnea Index (AHI) $$\ge $$ ≥ 5, AHI $$\ge $$ ≥ 15, and AHI $$\ge $$ ≥ 30, respectively. The results of this study demonstrate significant evidence of sufficient potential to utilize machine learning in predicting OSAS severity.


  • Open Access

    The simplification of the insomnia severity index and epworth sleepiness scale using machine learning models

    by Woodo Lee, Hyejin Kim, Jaekwoun Shim, Dongsin Kim, Janghun Hyeon, Eunyeon Joo, Byung-Euk Joo, Junhyoung Oh

    Insomnia and excessive daytime sleepiness (EDS) are the most common complaints in sleep clinics, and the cost of healthcare services associated with them have also increased significantly. Though the brief questionnaires such as the Insomnia Severity Index (ISI) and Epworth Sleepiness Scale (ESS) can be useful to assess insomnia and EDS, there are some limitations to apply for large numbers of patients. As the researches using the Internet of Things technology become more common, the need for the simplification of sleep questionnaires has been also growing. We aimed to simplify ISI and ESS using machine learning algorithms and deep neural networks with attention models. The medical records of 1,241 patients who examined polysomnography for insomnia or EDS were analyzed. All patients are classified into five groups according to the severity of insomnia and EDS. To develop the model, six machine learning algorithms were firstly applied. After going through normalization, the process with the CNN+ Attention model was applied. We classified a group with an accuracy of 93% even with only the results of 6 items (ISI1a, ISI1b, ISI3, ISI5, ESS4, ESS7). We simplified the sleep questionnaires with maintaining high accuracy by using machine learning models.


  • Open Access

    Consider the Consequences: A Risk Assessment Approach for Industrial Control Systems

    by Aram Kim, Junhyoung Oh, Kookheui Kwon, Kyungho Lee

    The development of information and communication technologies extended the application of digitalized industrial control systems (ICSs) to critical infrastructure. With this circumstance, emerging sophisticated cyberattacks by adversaries, including nation-backed terrorists, target ICSs due to their strategic value that critical infrastructure can cause severe consequences to equipment, people, and the environment due to the cyberattacks on ICSs. Therefore, critical infrastructure owners should provide high assurance to those involved, such as neighboring residents and governments, that the facility is adequately protected against cyberattacks. The risk assessment that identifies, estimates, and prioritizes risks is vital to provide high assurance. This study proposes a framework for evaluating risks by quantifying the likelihood of cyber exploitation and the consequences of cyberattacks. The quantification of the likelihood of cyber exploitation is inspired by research on Bayesian attack graphs (BAGs), allowing probability evaluation that considers the causal relationship between ICSs and multistage attacks. For the cyberattack consequences quantification, we propose a methodology to evaluate how far an impact will spread and thus how many functions will be influenced when an ICS is exploited. The methodology is conducted by ICS experts identifying and listing functional dependencies and essential function goals among ICSs that they are already familiar with and do not require in-depth cybersecurity knowledge. Through experiments, we demonstrated how to apply our framework to assess the risks of the plant protection system, which is a safety-grade digital system used in nuclear power plants. The result shows that risk can be multidimensionally assessed than previous literature, such as discovering that components that were not considered important have high risk due to their functional connectivity.


  • Open Access

    A New Approach to Estimate Concentration Levels with Filtered Neural Nets for Online Learning

    by Woodo Lee, Junhyoung Oh, Jaekwoun Shim

    The COVID-19 pandemic heavily influenced human life by constricting human social activity. Following the spread of the pandemic, humans did not have a choice but to change their lifestyles. There has been much change in the field of education, which has led to schools hosting online classes as an alternative to face-to-face classes. However, the concentration level is lowered in the online learning class, and the student’s learning rate decreases. We devise a framework for recognizing and estimating students’ concentration levels to help lecturers. Previous studies have a limitation in that they classified attention levels using only discrete states. Due to the partial information from discrete states, the concentration levels could not be recognized well. This research aims to estimate more subtle levels as specified states by using a minimum amount of body movement data. The deep neural network is used to continuously recognize the human concentration model, and the concentration levels can be predicted and estimated by the Kalman filter. Using our framework, we successfully extracted the concentration levels, which can aid lecturers and can be expanded to other areas. To implement the framework, we recruited participants to take online classes. Data were collected and preprocessed using pose points, and an accuracy of 90.62 was calculated by predicting the concentration level using the framework. Furthermore, the concentration level was approximated based on the Kalman filter. We found that webcams can be used to quantitatively measure student concentration when conducting online classes. Our framework is a great help for instructors to measure concentration levels, which can increase the learning efficiency. As a future work of this study, if emotion data and skin thermal data are comprehensively considered, a student’s concentration level can be measured more precisely.


  • Open Access

    Will EU’s GDPR Act as an Effective Enforcer to Gain Consent?

    by Junhyoung Oh, Jinhyoung Hong, Changsoo Lee, Jemin Justin Lee, Simon S. Woo, Kyungho Lee

    Since the GDPR was implemented in 2018, organizations that collect data from the EU residents are required to receive the user's consent. Organizational measures to ensure that the organizations are compliant to the recently enacted GDPR are still abstract and ambiguous. Moreover, data subjects and controllers have demanded the practice of obtaining consent from organizations. By observing the case law and guidelines related to the GDPR provisions, we deduced four consent conditions. Then, we examined how online service provider's websites are making efforts to implement the GDPR framework. For this, we identified key characteristics of these websites, such as the existence of consent buttons. In order to help the data subjects obtain consent, we proposed an automatic tool that can check the consent conditions by checking the websites. Our study examined 10,000 websites for 26 days using the Python libraries with the tool automatically crawling the website information and analyzes the HTML structure according to the specified conditions. In addition, this tool crawls the privacy policy of each website. Moreover, it automatically determines whether it meets the four consent conditions by calculating it according to the formula defined in the consent condition. To evaluate the tool's accuracy, the researchers manually analyzed 500 websites and compared the manual analysis with the results of the tool's automatic analysis. We found that this tool differentiates itself through qualitative comparisons with other GDPR meters.