Bernard Fernandes Kusel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bernard Fernandes Kusel has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kleber Melo Silva
Department of Electrical Engineering, University of Braslia, Braslia, Brazil
4 shared publications - Felipe Vigolvino Lopes
Federal University of Paraba, Brazil
2 shared publications Damasio Fernandes
1 shared publicationWashignton L.A. Neves
1 shared publication
Latest Publications
- 10 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 14 (1) , 248-253
Traveling Wave-Based Fault Location on Half-Wavelength Transmission Lines
Transmission lines little longer than half-wavelength have been studied as an alternative for power transmission over very long distances. Recent studies about fault location procedures have proved that most impedance-based techniques are not able to correctly identify the fault point in this kind of line. In this paper, the performance of a two-terminal traveling wave-based fault location approach applied to a transmission line little longer than half-wavelength is investigated through simulations in the Alternative Transients Program (ATP), from which several fault scenarios in a 1000 kV AC line 2600 km long are analyzed. The obtained results indicate traveling wave-based approaches are robust to the atypical operation features of half-wavelength power transmission lines, being suitable for fault location applications in this kind of line.
- 10 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 14 (1) , 248-253
Traveling Wave-Based Fault Location on Half-Wavelength Transmission Lines
Transmission lines little longer than half-wavelength have been studied as an alternative for power transmission over very long distances. Recent studies about fault location procedures have proved that most impedance-based techniques are not able to correctly identify the fault point in this kind of line. In this paper, the performance of a two-terminal traveling wave-based fault location approach applied to a transmission line little longer than half-wavelength is investigated through simulations in the Alternative Transients Program (ATP), from which several fault scenarios in a 1000 kV AC line 2600 km long are analyzed. The obtained results indicate traveling wave-based approaches are robust to the atypical operation features of half-wavelength power transmission lines, being suitable for fault location applications in this kind of line.
- 1 September 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 114, 101-109
Fault location on transmission lines little longer than half-wavelength
- 1 September 2014
- Published by Elsevier in Electric Power Systems Research
- Vol. 114, 101-109
Fault location on transmission lines little longer than half-wavelength
- Open Access
- 1 March 2013
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 49 (6) , 412-414
DFT based phasor estimation algorithm for numerical digital relaying
A novel phasor estimation algorithm is proposed, by means of an innovative modification of the traditional full cycle discrete Fourier transformer (FCDFT) algorithm. The main idea is to combine the FCDFT outputs for even and odd sample‐setsobtained for one cycle data window decimated by two and by four. Its performance was compared with the ones of other full cycle algorithms reported in the late literature on the subject. The obtained results reveal the proposed algorithm leads to the best performance, even considering both the decaying DC component of the fault current and the one caused by the current transformer secondary circuit.
- 1 March 2013
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 49 (6) , 412-414
Open AccessDFT based phasor estimation algorithm for numerical digital relaying
A novel phasor estimation algorithm is proposed, by means of an innovative modification of the traditional full cycle discrete Fourier transformer (FCDFT) algorithm. The main idea is to combine the FCDFT outputs for even and odd sample‐setsobtained for one cycle data window decimated by two and by four. Its performance was compared with the ones of other full cycle algorithms reported in the late literature on the subject. The obtained results reveal the proposed algorithm leads to the best performance, even considering both the decaying DC component of the fault current and the one caused by the current transformer secondary circuit.
- 1 November 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 92, 60-72
On combining wavelet-based designed filters and an adaptive mimic filter for phasor estimation in digital relaying
- 1 November 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 92, 60-72
On combining wavelet-based designed filters and an adaptive mimic filter for phasor estimation in digital relaying